Michael A. Choma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael A. Choma has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Brendan K. Huang
Yale University, Department of Biomedical Engineering, Yale University, 55 Prospect Street, New Haven, CT, 06511, USA
9 shared publicationsMustafa K. Khokha
Yale University, Department of Pediatrics, Yale University, 333 Cedar Street, New Haven, CT, 06520, USA
8 shared publicationsUte A. Gamm
Yale University, Department of Radiology & Biomedical Imaging, Yale University, 333 Cedar Street, New Haven, CT, 06520, USA
5 shared publicationsHui Cao
Applied Physics, Yale University, New Haven, CT 06511, USA
4 shared publications- Stephan Jonas
University Hospital Bonn
4 shared publications Vineet Bhandari
Department of Pediatrics, Yale University, 333 Cedar St., New Haven, Connecticut 06510, USA
4 shared publications
Latest Publications
- Open Access
- 8 November 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 15115
Visualization and quantification of injury to the ciliated epithelium using quantitative flow imaging and speckle variance optical coherence tomography
Mucociliary flow is an important defense mechanism in the lung to remove inhaled pathogens and pollutants. Disruption of ciliary flow can lead to respiratory infections. Multiple factors, from drugs to disease can cause an alteration in ciliary flow. However, less attention has been given to injury of the ciliated epithelium. In this study, we show how optical coherence tomography (OCT) can be used to investigate injury to the ciliated epithelium in a multi-contrast setting. We used particle tracking velocimetry (PTV-OCT) to investigate the cilia-driven flow field and 3D speckle variance imaging to investigate size and extent of injury caused to the skin of Xenopus embryos. Two types of injuries are investigated, focal injury caused by mechanical damage and diffuse injury by a calcium chloride shock. We additionally investigate injury and regeneration of cilia to calcium chloride on ex vivo mouse trachea. This work describes how OCT can be used as a tool to investigate injury and regeneration in ciliated epithelium.
- 8 November 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 15115
Open AccessVisualization and quantification of injury to the ciliated epithelium using quantitative flow imaging and speckle variance optical coherence tomography
Mucociliary flow is an important defense mechanism in the lung to remove inhaled pathogens and pollutants. Disruption of ciliary flow can lead to respiratory infections. Multiple factors, from drugs to disease can cause an alteration in ciliary flow. However, less attention has been given to injury of the ciliated epithelium. In this study, we show how optical coherence tomography (OCT) can be used to investigate injury to the ciliated epithelium in a multi-contrast setting. We used particle tracking velocimetry (PTV-OCT) to investigate the cilia-driven flow field and 3D speckle variance imaging to investigate size and extent of injury caused to the skin of Xenopus embryos. Two types of injuries are investigated, focal injury caused by mechanical damage and diffuse injury by a calcium chloride shock. We additionally investigate injury and regeneration of cilia to calcium chloride on ex vivo mouse trachea. This work describes how OCT can be used as a tool to investigate injury and regeneration in ciliated epithelium.
- Open Access
- 20 October 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (11) , 4674-4684
Ultrahigh-speed, phase-sensitive full-field interferometric confocal microscopy for quantitative microscale physiology
We developed ultra-high-speed, phase-sensitive, full-field reflection interferometric confocal microscopy (FFICM) for the quantitative characterization of in vivo microscale biological motions and flows. We demonstrated 2D frame rates in excess of 1 kHz and pixel throughput rates up to 125 MHz. These fast FFICM frame rates were enabled by the use of a low spatial coherence, high-power laser source. Specifically, we used a dense vertical cavity surface emitting laser (VCSEL) array that synthesized low spatial coherence light through a large number of narrowband, mutually-incoherent emitters. Off-axis interferometry enabled single-shot acquisition of the complex-valued interferometric signal. We characterized the system performance (~2 μm lateral resolution, ~8 μm axial gating depth) with a well-known target. We also demonstrated the use of this highly parallelized confocal microscopy platform for visualization and quantification of cilia-driven surface flows and cilia beat frequency in an important animal model (Xenopus embryos) with >1 kHz frame rate. Such frame rates are needed to see large changes in local flow velocity over small distance (high shear flow), in this case, local flow around a single ciliated cell. More generally, our results are an important demonstration of low-spatial coherence, high-power lasers in high-performance, quantitative biomedical imaging.
- 20 October 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (11) , 4674-4684
Open AccessUltrahigh-speed, phase-sensitive full-field interferometric confocal microscopy for quantitative microscale physiology
We developed ultra-high-speed, phase-sensitive, full-field reflection interferometric confocal microscopy (FFICM) for the quantitative characterization of in vivo microscale biological motions and flows. We demonstrated 2D frame rates in excess of 1 kHz and pixel throughput rates up to 125 MHz. These fast FFICM frame rates were enabled by the use of a low spatial coherence, high-power laser source. Specifically, we used a dense vertical cavity surface emitting laser (VCSEL) array that synthesized low spatial coherence light through a large number of narrowband, mutually-incoherent emitters. Off-axis interferometry enabled single-shot acquisition of the complex-valued interferometric signal. We characterized the system performance (~2 μm lateral resolution, ~8 μm axial gating depth) with a well-known target. We also demonstrated the use of this highly parallelized confocal microscopy platform for visualization and quantification of cilia-driven surface flows and cilia beat frequency in an important animal model (Xenopus embryos) with >1 kHz frame rate. Such frame rates are needed to see large changes in local flow velocity over small distance (high shear flow), in this case, local flow around a single ciliated cell. More generally, our results are an important demonstration of low-spatial coherence, high-power lasers in high-performance, quantitative biomedical imaging.
- Open Access
- 11 October 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (20) , 4775-4778
Coherent artifact suppression in line-field reflection confocal microscopy using a low spatial coherence light source
Line-field reflection confocal microscopy (LF-RCM) has the potential to add a dimension of parallelization to traditional confocal microscopy while reducing the need for two-axis beam scanning. LF-RCM systems often employ light sources with a high degree of spatial coherence. This high degree of spatial coherence potentially leads to unwanted coherent artifact in the setting of nontrivial sample scattering. Here, we (a) confirm that a coherent artifact is a nontrivial problem in LF-RCM when using spatially coherent light, and (b) demonstrate that such a coherent artifact can be mitigated through the use of reduced spatial coherence line-field sources. We demonstrate coherent noise suppression in a full-pupil line-field confocal microscope using a large number of mutually incoherent emitters from a vertical-cavity surface-emitting lasers (VCSEL) array. The coherent noise from a highly scattering sample is significantly suppressed by the use of this synthesized reduced spatial coherence light source compared to a fully coherent light source. Lastly, with scattering samples, the axial confocality of line-field confocal microscopy is compromised independent of the source spatial coherence, as demonstrated by our experimental result. Our results highlight the importance of spatial coherence engineering in parallelized reflection confocal microscopy.
- 11 October 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (20) , 4775-4778
Open AccessCoherent artifact suppression in line-field reflection confocal microscopy using a low spatial coherence light source
Line-field reflection confocal microscopy (LF-RCM) has the potential to add a dimension of parallelization to traditional confocal microscopy while reducing the need for two-axis beam scanning. LF-RCM systems often employ light sources with a high degree of spatial coherence. This high degree of spatial coherence potentially leads to unwanted coherent artifact in the setting of nontrivial sample scattering. Here, we (a) confirm that a coherent artifact is a nontrivial problem in LF-RCM when using spatially coherent light, and (b) demonstrate that such a coherent artifact can be mitigated through the use of reduced spatial coherence line-field sources. We demonstrate coherent noise suppression in a full-pupil line-field confocal microscope using a large number of mutually incoherent emitters from a vertical-cavity surface-emitting lasers (VCSEL) array. The coherent noise from a highly scattering sample is significantly suppressed by the use of this synthesized reduced spatial coherence light source compared to a fully coherent light source. Lastly, with scattering samples, the axial confocality of line-field confocal microscopy is compromised independent of the source spatial coherence, as demonstrated by our experimental result. Our results highlight the importance of spatial coherence engineering in parallelized reflection confocal microscopy.
- Open Access
- 23 May 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (6) , 2360-2361
Particle streak velocimetry-optical coherence tomography: a novel method for multidimensional imaging of microscale fluid flows: erratum
A table summarizing existing methods for velocimetry using OCT miscategorized Lee et al.’s work on DLS-OCT as being intensity-based, when it was actually field-based. This erratum report gives the corrected table. Also, the acknowledgments section was missing, which we include here.
- 23 May 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (6) , 2360-2361
Open AccessParticle streak velocimetry-optical coherence tomography: a novel method for multidimensional imaging of microscale fluid flows: erratum
A table summarizing existing methods for velocimetry using OCT miscategorized Lee et al.’s work on DLS-OCT as being intensity-based, when it was actually field-based. This erratum report gives the corrected table. Also, the acknowledgments section was missing, which we include here.
- Open Access
- 19 April 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (9) , 9251-9265
High-speed line-field confocal holographic microscope for quantitative phase imaging
We present a high-speed and phase-sensitive reflectance line-scanning confocal holographic microscope (LCHM). We achieved rapid confocal imaging using a fast line-scan CCD camera and quantitative phase imaging using off-axis digital holography (DH) on a 1D, line-by-line basis in our prototype experiment. Using a 20 kHz line scan rate, we achieved a frame rate of 20 Hz for 512x512 pixels en-face confocal images. We realized coherent holographic detection two different ways. We first present a LCHM using off-axis configuration. By using a microscope objective of a NA 0.65, we achieved axial and lateral resolution of ~3.5 micrometers and ~0.8 micrometers, respectively. We demonstrated surface profile measurement of a phase target at nanometer precision and the digital refocusing of a defocused confocal en-face image. Ultrahigh temporal resolution M mode is demonstrated by measuring the vibration of a PZT-actuated mirror driven by a sine wave at 1 kHz. We then report our experimental work on a LCHM using an in-line configuration. In this in-line LCHM, the coherent detection is enabled by moving the reference arm at a constant speed, thereby introducing a Doppler frequency shift that leads to spatial interference fringes along the scanning direction. Lastly, we present a unified formulation that treats off-axis and in-line LCHM in a unified joint spatiotemporal modulation framework and provide a connection between LCHM and the traditional off-axis DH. The presented high-speed LCHM may find applications in optical metrology and biomedical imaging.
- 19 April 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (9) , 9251-9265
Open AccessHigh-speed line-field confocal holographic microscope for quantitative phase imaging
We present a high-speed and phase-sensitive reflectance line-scanning confocal holographic microscope (LCHM). We achieved rapid confocal imaging using a fast line-scan CCD camera and quantitative phase imaging using off-axis digital holography (DH) on a 1D, line-by-line basis in our prototype experiment. Using a 20 kHz line scan rate, we achieved a frame rate of 20 Hz for 512x512 pixels en-face confocal images. We realized coherent holographic detection two different ways. We first present a LCHM using off-axis configuration. By using a microscope objective of a NA 0.65, we achieved axial and lateral resolution of ~3.5 micrometers and ~0.8 micrometers, respectively. We demonstrated surface profile measurement of a phase target at nanometer precision and the digital refocusing of a defocused confocal en-face image. Ultrahigh temporal resolution M mode is demonstrated by measuring the vibration of a PZT-actuated mirror driven by a sine wave at 1 kHz. We then report our experimental work on a LCHM using an in-line configuration. In this in-line LCHM, the coherent detection is enabled by moving the reference arm at a constant speed, thereby introducing a Doppler frequency shift that leads to spatial interference fringes along the scanning direction. Lastly, we present a unified formulation that treats off-axis and in-line LCHM in a unified joint spatiotemporal modulation framework and provide a connection between LCHM and the traditional off-axis DH. The presented high-speed LCHM may find applications in optical metrology and biomedical imaging.
- Open Access
- 30 March 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (4) , 1590-1603
Particle streak velocimetry-optical coherence tomography: a novel method for multidimensional imaging of microscale fluid flows
We present a new OCT method for flow speed quantification and directional velocimetry: particle streak velocimetry-OCT (PSV-OCT). PSV-OCT generates two-dimensional, 2.5-vector component (vx,|vy|,vz) maps of microscale flow velocity fields. Knowledge of 2.5-vector components also enables the estimation of total flow speed. The enabling insight behind PSV-OCT is that tracer particles in sparsely-seeded fluid flow trace out streaks in (x,z,t)-space. The streak orientations in x-t and z-t yield vx and vz, respectively. The in-plane (x-z plane) residence time yields the out-of-plane speed |vy|. Vector component values are generated by fitting streaks to a model of image formation that incorporates equations of motion in 3D space. We demonstrate cross-sectional estimation of (vx,|vy|,vz) in two important animal models in ciliary biology: Xenopus embryos (tadpoles) and mouse trachea.
- 30 March 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (4) , 1590-1603
Open AccessParticle streak velocimetry-optical coherence tomography: a novel method for multidimensional imaging of microscale fluid flows
We present a new OCT method for flow speed quantification and directional velocimetry: particle streak velocimetry-OCT (PSV-OCT). PSV-OCT generates two-dimensional, 2.5-vector component (vx,|vy|,vz) maps of microscale flow velocity fields. Knowledge of 2.5-vector components also enables the estimation of total flow speed. The enabling insight behind PSV-OCT is that tracer particles in sparsely-seeded fluid flow trace out streaks in (x,z,t)-space. The streak orientations in x-t and z-t yield vx and vz, respectively. The in-plane (x-z plane) residence time yields the out-of-plane speed |vy|. Vector component values are generated by fitting streaks to a model of image formation that incorporates equations of motion in 3D space. We demonstrate cross-sectional estimation of (vx,|vy|,vz) in two important animal models in ciliary biology: Xenopus embryos (tadpoles) and mouse trachea.
- Open Access
- 1 January 2016
- Published by Optica Publishing Group
- p. ATh1N.1
Towards All-Optical Quantification of Ciliary Physiology
Cilia are organelles that generate microfluidic flows in the lungs, central nervous system, and Fallopian tubes. Quantitative flow diagnostic remain immature. I will present a comprehensive optical imaging-based approach for quantifying cilia flow physiology. Article not available.
- 1 January 2016
- Published by Optica Publishing Group
- p. ATh1N.1
Open AccessTowards All-Optical Quantification of Ciliary Physiology
Cilia are organelles that generate microfluidic flows in the lungs, central nervous system, and Fallopian tubes. Quantitative flow diagnostic remain immature. I will present a comprehensive optical imaging-based approach for quantifying cilia flow physiology. Article not available.
- Open Access
- 12 November 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (12) , 4796-4811
Improved velocimetry in optical coherence tomography using Bayesian analysis
OCT is a popular cross-sectional microscale imaging modality in medicine and biology. While structural imaging using OCT is a mature technology in many respects, flow and motion estimation using OCT remains an intense area of research. In particular, there is keen interest in maximizing information extraction from the complex-valued OCT signal. Here, we introduce a Bayesian framework into the data workflow in OCT-based velocimetry. We demonstrate that using prior information in this Bayesian framework can significantly improve velocity estimate precision in a correlation-based, model-based framework for Doppler and transverse velocimetry. We show results in calibrated flow phantoms as well as in vivo in a Drosophila melanogaster (fruit fly) heart. Thus, our work improves upon the current approaches in terms of improved information extraction from the complex-valued OCT signal.
- 12 November 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (12) , 4796-4811
Open AccessImproved velocimetry in optical coherence tomography using Bayesian analysis
OCT is a popular cross-sectional microscale imaging modality in medicine and biology. While structural imaging using OCT is a mature technology in many respects, flow and motion estimation using OCT remains an intense area of research. In particular, there is keen interest in maximizing information extraction from the complex-valued OCT signal. Here, we introduce a Bayesian framework into the data workflow in OCT-based velocimetry. We demonstrate that using prior information in this Bayesian framework can significantly improve velocity estimate precision in a correlation-based, model-based framework for Doppler and transverse velocimetry. We show results in calibrated flow phantoms as well as in vivo in a Drosophila melanogaster (fruit fly) heart. Thus, our work improves upon the current approaches in terms of improved information extraction from the complex-valued OCT signal.
- Open Access
- 26 August 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (08) , 1-4
Quantifying hyperoxia-mediated damage to mammalian respiratory cilia-driven fluid flow using particle tracking velocimetry optical coherence tomography
Oxygen supplementation [hyperoxia, increased fraction of inspired oxygen (FiO2)] is an indispensable treatment in the intensive care unit for patients in respiratory failure. Like other treatments or drugs, hyperoxia has a risk-benefit profile that guides its clinical use. While hyperoxia is known to damage respiratory epithelium, it is unknown if damage can result in impaired capacity to generate cilia-driven fluid flow. Here, we demonstrate that quantifying cilia-driven fluid flow velocities in the sub-100 μm/s regime (sub-0.25 in./min regime) reveals hyperoxia-mediated damage to the capacity of ciliated respiratory mucosa to generate directional flow. Flow quantification was performed using particle tracking velocimetry optical coherence tomography (PTV-OCT) in ex vivo mouse trachea. The ability of PTV-OCT to detect biomedically relevant flow perturbations in the sub-100 μm/s regime was validated by quantifying temperature- and drug-mediated modulation of flow performance in ex vivo mouse trachea. Overall, PTV-OCT imaging of cilia-driven fluid flow in ex vivo mouse trachea is a powerful and straightforward approach for studying factors that modulate and damage mammalian respiratory ciliary physiology.
- 26 August 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (08) , 1-4
Open AccessQuantifying hyperoxia-mediated damage to mammalian respiratory cilia-driven fluid flow using particle tracking velocimetry optical coherence tomography
Oxygen supplementation [hyperoxia, increased fraction of inspired oxygen (FiO2)] is an indispensable treatment in the intensive care unit for patients in respiratory failure. Like other treatments or drugs, hyperoxia has a risk-benefit profile that guides its clinical use. While hyperoxia is known to damage respiratory epithelium, it is unknown if damage can result in impaired capacity to generate cilia-driven fluid flow. Here, we demonstrate that quantifying cilia-driven fluid flow velocities in the sub-100 μm/s regime (sub-0.25 in./min regime) reveals hyperoxia-mediated damage to the capacity of ciliated respiratory mucosa to generate directional flow. Flow quantification was performed using particle tracking velocimetry optical coherence tomography (PTV-OCT) in ex vivo mouse trachea. The ability of PTV-OCT to detect biomedically relevant flow perturbations in the sub-100 μm/s regime was validated by quantifying temperature- and drug-mediated modulation of flow performance in ex vivo mouse trachea. Overall, PTV-OCT imaging of cilia-driven fluid flow in ex vivo mouse trachea is a powerful and straightforward approach for studying factors that modulate and damage mammalian respiratory ciliary physiology.
- Open Access
- 24 August 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (9) , 3515-3538
Three-dimensional, three-vector-component velocimetry of cilia-driven fluid flow using correlation-based approaches in optical coherence tomography
Microscale quantification of cilia-driven fluid flow is an emerging area in medical physiology, including pulmonary and central nervous system physiology. Cilia-driven fluid flow is most completely described by a three-dimensional, three-component (3D3C) vector field. Here, we generate 3D3C velocimetry measurements by synthesizing higher dimensional data from lower dimensional measurements obtained using two separate optical coherence tomography (OCT)-based approaches: digital particle image velocimetry (DPIV) and dynamic light scattering (DLS)-OCT. Building on previous work, we first demonstrate directional DLS-OCT for 1D2C velocimetry measurements in the sub-1 mm/s regime (sub-2.5 inch/minute regime) of cilia-driven fluid flow in Xenopus epithelium, an important animal model of the ciliated respiratory tract. We then extend our analysis toward 3D3C measurements in Xenopus using both DLS-OCT and DPIV. We demonstrate the use of DPIV-based approaches towards flow imaging of Xenopus cerebrospinal fluid and mouse trachea, two other important ciliary systems. Both of these flows typically fall in the sub-100 μm/s regime (sub-0.25 inch/minute regime). Lastly, we develop a framework for optimizing the signal-to-noise ratio of 3D3C flow velocity measurements synthesized from 2D2C measures in non-orthogonal planes. In all, 3D3C OCT-based velocimetry has the potential to comprehensively characterize the flow performance of biological ciliated surfaces.
- 24 August 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (9) , 3515-3538
Open AccessThree-dimensional, three-vector-component velocimetry of cilia-driven fluid flow using correlation-based approaches in optical coherence tomography
Microscale quantification of cilia-driven fluid flow is an emerging area in medical physiology, including pulmonary and central nervous system physiology. Cilia-driven fluid flow is most completely described by a three-dimensional, three-component (3D3C) vector field. Here, we generate 3D3C velocimetry measurements by synthesizing higher dimensional data from lower dimensional measurements obtained using two separate optical coherence tomography (OCT)-based approaches: digital particle image velocimetry (DPIV) and dynamic light scattering (DLS)-OCT. Building on previous work, we first demonstrate directional DLS-OCT for 1D2C velocimetry measurements in the sub-1 mm/s regime (sub-2.5 inch/minute regime) of cilia-driven fluid flow in Xenopus epithelium, an important animal model of the ciliated respiratory tract. We then extend our analysis toward 3D3C measurements in Xenopus using both DLS-OCT and DPIV. We demonstrate the use of DPIV-based approaches towards flow imaging of Xenopus cerebrospinal fluid and mouse trachea, two other important ciliary systems. Both of these flows typically fall in the sub-100 μm/s regime (sub-0.25 inch/minute regime). Lastly, we develop a framework for optimizing the signal-to-noise ratio of 3D3C flow velocity measurements synthesized from 2D2C measures in non-orthogonal planes. In all, 3D3C OCT-based velocimetry has the potential to comprehensively characterize the flow performance of biological ciliated surfaces.