Robert Jenison
Research Subjects
Robert Jenison has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Brian Hicke
Great Basin Scientific, Salt Lake City, Utah, USA
2 shared publications Evelyn Woodruff
Great Basin Corporation, Salt Lake City, Utah, USA
2 shared publicationsHeidi Jaeckel
Great Basin, Corp
2 shared publicationsJoshua Klonoski
Great Basin, Corp
2 shared publicationsLarry Rea
Great Basin Corporation, Salt Lake City, Utah, USA
2 shared publicationsWanyuan Ao
Great Basin Corporation, Salt Lake City, Utah, United States of America
2 shared publications
Latest Publications
- Open Access
- 22 February 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (2) , e0171915
A novel approach to eliminate detection of contaminating Staphylococcal species introduced during clinical testing
We describe here a strategy that can distinguish between Staphylococcus species truly present in a clinical sample from contaminating Staphylococcus species introduced during the testing process. Contaminating Staphylococcus species are present at low levels in PCR reagents and colonize lab personnel. To eliminate detection of contaminants, we describe an approach that utilizes addition of sufficient quantities of either non-target Staphylococcal cells (Staphylococcus succinus or Staphylococcus muscae) or synthetic oligonucleotide templates to helicase dependent isothermal amplification reactions to consume Staphylococcus-specific tuf and mecA gene primers such that contaminating Staphylococcus amplification is suppressed to below assay limits of detection. The suppressor template DNA is designed with perfect homology to the primers used in the assay but an internal sequence that is unrelated to the Staphylococcal species targeted for detection. Input amount of the suppressor is determined by a mathematical model described herein and is demonstrated to completely suppress contaminating levels of Staphylococcus while not negatively impacting the appropriate clinical assay limit of detection. We have applied this approach to improve the specificity of detection of Staphylococcus species present in positive blood cultures using a chip-based array that produces results visible to the unaided eye.
- 22 February 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (2) , e0171915
Open AccessA novel approach to eliminate detection of contaminating Staphylococcal species introduced during clinical testing
We describe here a strategy that can distinguish between Staphylococcus species truly present in a clinical sample from contaminating Staphylococcus species introduced during the testing process. Contaminating Staphylococcus species are present at low levels in PCR reagents and colonize lab personnel. To eliminate detection of contaminants, we describe an approach that utilizes addition of sufficient quantities of either non-target Staphylococcal cells (Staphylococcus succinus or Staphylococcus muscae) or synthetic oligonucleotide templates to helicase dependent isothermal amplification reactions to consume Staphylococcus-specific tuf and mecA gene primers such that contaminating Staphylococcus amplification is suppressed to below assay limits of detection. The suppressor template DNA is designed with perfect homology to the primers used in the assay but an internal sequence that is unrelated to the Staphylococcal species targeted for detection. Input amount of the suppressor is determined by a mathematical model described herein and is demonstrated to completely suppress contaminating levels of Staphylococcus while not negatively impacting the appropriate clinical assay limit of detection. We have applied this approach to improve the specificity of detection of Staphylococcus species present in positive blood cultures using a chip-based array that produces results visible to the unaided eye.
- 22 May 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (15) , 3763-3769
Rapid amplification/detection of nucleic acid targets utilizing a HDA/thin film biosensor
Thin film biosensors exploit a flat, optically coated silicon-based surface whereupon formation of nucleic acid hybrids are enzymatically transduced in a molecular thin film that can be detected by the unaided human eye under white light. While the limit of sensitivity for detection of nucleic acid targets is at sub-attomole levels (60 000 copies) many clinical specimens containing bacterial pathogens have much lower levels of analyte present. Herein, we describe a platform, termed HDA/thin film biosensor, which performs helicase-dependant nucleic acid amplification on a thin film biosensor surface to improve the limit of sensitivity to 10 copies of the mecA gene present in methicillin-resistant strains of Staphylococcus. As double-stranded DNA is unwound by helicase it was either bound by solution-phase DNA primers to be copied by DNA polymerase or hybridized to surface immobilized probe on the thin film biosensor surface to be detected. Herein, we show that amplification reactions on the thin film biosensor are equivalent to in standard thin wall tubes, with detection at the limit of sensitivity of the assay occurring after 30 minutes of incubation time. Further we validate the approach by detecting the presence of the mecA gene in methicillin-resistant Staphylococcus aureus (MRSA) from positive blood culture aliquots with high specificity (signal/noise ratio of 105).
- 22 May 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (15) , 3763-3769
Rapid amplification/detection of nucleic acid targets utilizing a HDA/thin film biosensor
Thin film biosensors exploit a flat, optically coated silicon-based surface whereupon formation of nucleic acid hybrids are enzymatically transduced in a molecular thin film that can be detected by the unaided human eye under white light. While the limit of sensitivity for detection of nucleic acid targets is at sub-attomole levels (60 000 copies) many clinical specimens containing bacterial pathogens have much lower levels of analyte present. Herein, we describe a platform, termed HDA/thin film biosensor, which performs helicase-dependant nucleic acid amplification on a thin film biosensor surface to improve the limit of sensitivity to 10 copies of the mecA gene present in methicillin-resistant strains of Staphylococcus. As double-stranded DNA is unwound by helicase it was either bound by solution-phase DNA primers to be copied by DNA polymerase or hybridized to surface immobilized probe on the thin film biosensor surface to be detected. Herein, we show that amplification reactions on the thin film biosensor are equivalent to in standard thin wall tubes, with detection at the limit of sensitivity of the assay occurring after 30 minutes of incubation time. Further we validate the approach by detecting the presence of the mecA gene in methicillin-resistant Staphylococcus aureus (MRSA) from positive blood culture aliquots with high specificity (signal/noise ratio of 105).
- Open Access
- 11 August 2012
- Published by Springer Nature in BMC Research Notes
- Vol. 5 (1) , 430
Direct detection of nasal Staphylococcus aureus carriage via helicase-dependent isothermal amplification and chip hybridization
Background: The bacterium Staphylococcus aureus constitutes one of the most important causes of nosocomial infections. One out of every three individuals naturally carries S. aureus in their anterior nares, and nasal carriage is associated with a significantly higher infection rate in hospital settings. Nasal carriage can be either persistent or intermittent, and it is the persistent carriers who, as a group, are at the highest risk of infection and who have the highest nasal S. aureus cell counts. Prophylactic decolonization of S. aureus from patients’ noses is known to reduce the incidence of postsurgical infections, and there is a clear rationale for rapid identification of nasal S. aureus carriers among hospital patients. Findings: A molecular diagnostic assay was developed which is based on helicase-dependent target amplification and amplicon detection by chip hybridization to a chip surface, producing a visible readout. Nasal swabs from 70 subjects were used to compare the molecular assay against culturing on “CHROMagar Staph aureus” agar plates. The overall relative sensitivity was 89%, and the relative specificity was 94%. The sensitivity rose to 100% when excluding low-count subjects (100 S. aureus colony-forming units per swab) nasal S. aureus carriers who are at greatest risk for nosocomial infections.
- 11 August 2012
- Published by Springer Nature in BMC Research Notes
- Vol. 5 (1) , 430
Open AccessDirect detection of nasal Staphylococcus aureus carriage via helicase-dependent isothermal amplification and chip hybridization
Background: The bacterium Staphylococcus aureus constitutes one of the most important causes of nosocomial infections. One out of every three individuals naturally carries S. aureus in their anterior nares, and nasal carriage is associated with a significantly higher infection rate in hospital settings. Nasal carriage can be either persistent or intermittent, and it is the persistent carriers who, as a group, are at the highest risk of infection and who have the highest nasal S. aureus cell counts. Prophylactic decolonization of S. aureus from patients’ noses is known to reduce the incidence of postsurgical infections, and there is a clear rationale for rapid identification of nasal S. aureus carriers among hospital patients. Findings: A molecular diagnostic assay was developed which is based on helicase-dependent target amplification and amplicon detection by chip hybridization to a chip surface, producing a visible readout. Nasal swabs from 70 subjects were used to compare the molecular assay against culturing on “CHROMagar Staph aureus” agar plates. The overall relative sensitivity was 89%, and the relative specificity was 94%. The sensitivity rose to 100% when excluding low-count subjects (100 S. aureus colony-forming units per swab) nasal S. aureus carriers who are at greatest risk for nosocomial infections.
- Open Access
- 1 July 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (7) , 2433-2440
Rapid Detection of rpoB Gene Mutations Conferring Rifampin Resistance in Mycobacterium tuberculosis
Multidrug-resistant Mycobacterium tuberculosis strains are widespread and present a challenge to effective treatment of this infection. The need for a low-cost and rapid detection method for clinically relevant mutations in Mycobacterium tuberculosis that confer multidrug resistance is urgent, particularly for developing countries. We report here a novel test that detects the majority of clinically relevant mutations in the beta subunit of the RNA polymerase ( rpoB ) gene that confer resistance to rifampin (RIF), the treatment of choice for tuberculosis (TB). The test, termed TB ID/R, combines a novel target and temperature-dependent RNase H2-mediated cleavage of blocked DNA primers to initiate isothermal helicase-dependent amplification of a rpoB gene target sequence. Amplified products are detected by probes arrayed on a modified silicon chip that permits visible detection of both RIF-sensitive and RIF-resistant strains of M. tuberculosis . DNA templates of clinically relevant single-nucleotide mutations in the rpoB gene were created to validate the performance of the TB ID/R test. Except for one rare mutation, all mutations were unambiguously detected. Additionally, 11 RIF-sensitive and 25 RIF-resistant clinical isolates were tested by the TB ID/R test, and 35/36 samples were classified correctly (96.2%). This test is being configured in a low-cost test platform to provide rapid diagnosis and drug susceptibility information for TB in the point-of-care setting in the developing world, where the need is acute.
- 1 July 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (7) , 2433-2440
Open AccessRapid Detection of rpoB Gene Mutations Conferring Rifampin Resistance in Mycobacterium tuberculosis
Multidrug-resistant Mycobacterium tuberculosis strains are widespread and present a challenge to effective treatment of this infection. The need for a low-cost and rapid detection method for clinically relevant mutations in Mycobacterium tuberculosis that confer multidrug resistance is urgent, particularly for developing countries. We report here a novel test that detects the majority of clinically relevant mutations in the beta subunit of the RNA polymerase ( rpoB ) gene that confer resistance to rifampin (RIF), the treatment of choice for tuberculosis (TB). The test, termed TB ID/R, combines a novel target and temperature-dependent RNase H2-mediated cleavage of blocked DNA primers to initiate isothermal helicase-dependent amplification of a rpoB gene target sequence. Amplified products are detected by probes arrayed on a modified silicon chip that permits visible detection of both RIF-sensitive and RIF-resistant strains of M. tuberculosis . DNA templates of clinically relevant single-nucleotide mutations in the rpoB gene were created to validate the performance of the TB ID/R test. Except for one rare mutation, all mutations were unambiguously detected. Additionally, 11 RIF-sensitive and 25 RIF-resistant clinical isolates were tested by the TB ID/R test, and 35/36 samples were classified correctly (96.2%). This test is being configured in a low-cost test platform to provide rapid diagnosis and drug susceptibility information for TB in the point-of-care setting in the developing world, where the need is acute.
- Open Access
- 1 March 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (3) , 810-817
Staph ID/R: a Rapid Method for Determining Staphylococcus Species Identity and Detecting the mecA Gene Directly from Positive Blood Culture
Rapid diagnosis of staphylococcal bacteremia directs appropriate antimicrobial therapy, leading to improved patient outcome. We describe herein a rapid test (mecA . The test, Staph ID/R, combines a rapid isothermal nucleic acid amplification method, helicase-dependent amplification (HDA), with a chip-based array that produces unambiguous visible results. The analytic sensitivity was 1 CFU per reaction for the mecA gene and was 1 to 250 CFU per reaction depending on the staphylococcal species present in the positive blood culture. Staph ID/R has excellent specificity as well, with no cross-reactivity observed. We validated the performance of Staph ID/R by testing 104 frozen clinical positive blood cultures and comparing the results with rpoB gene or 16S rRNA gene sequencing for species identity determinations and mecA gene PCR to confirm mecA gene results. Staph ID/R agreed with mecA gene PCR for all samples and agreed with rpoB /16S rRNA gene sequencing in all cases except for one sample that contained a mixture of two staphylococcal species, one of which Staph ID/R correctly identified, for an overall agreement of 99.0% ( P < 0.01). Staph ID/R could potentially be used to positively affect patient management for Staphylococcus -mediated bacteremia.
- 1 March 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (3) , 810-817
Open AccessStaph ID/R: a Rapid Method for Determining Staphylococcus Species Identity and Detecting the mecA Gene Directly from Positive Blood Culture
Rapid diagnosis of staphylococcal bacteremia directs appropriate antimicrobial therapy, leading to improved patient outcome. We describe herein a rapid test (mecA . The test, Staph ID/R, combines a rapid isothermal nucleic acid amplification method, helicase-dependent amplification (HDA), with a chip-based array that produces unambiguous visible results. The analytic sensitivity was 1 CFU per reaction for the mecA gene and was 1 to 250 CFU per reaction depending on the staphylococcal species present in the positive blood culture. Staph ID/R has excellent specificity as well, with no cross-reactivity observed. We validated the performance of Staph ID/R by testing 104 frozen clinical positive blood cultures and comparing the results with rpoB gene or 16S rRNA gene sequencing for species identity determinations and mecA gene PCR to confirm mecA gene results. Staph ID/R agreed with mecA gene PCR for all samples and agreed with rpoB /16S rRNA gene sequencing in all cases except for one sample that contained a mixture of two staphylococcal species, one of which Staph ID/R correctly identified, for an overall agreement of 99.0% ( P < 0.01). Staph ID/R could potentially be used to positively affect patient management for Staphylococcus -mediated bacteremia.
- 15 January 2010
- Published by Elsevier in Analytical Biochemistry
- Vol. 396 (2) , 284-289
Enhanced detection of staphylococcal genomes in positive blood cultures using a polymeric enzyme complex
- 15 January 2010
- Published by Elsevier in Analytical Biochemistry
- Vol. 396 (2) , 284-289
Enhanced detection of staphylococcal genomes in positive blood cultures using a polymeric enzyme complex