Spencer D. Polley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Spencer D. Polley has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Peter L. Chiodini
Department of Clinical Parasitology, Hospital for Tropical Diseases, London, UK
4 shared publications - Iveth J. González
Foundation for Innovative New Diagnostics (FIND)
3 shared publications - Colin J. Sutherland
London School of Hygiene & Tropical Medicine
2 shared publications - Alice Chijioke Eziefula
London School of Hygiene and Tropical Medicine, London, UK
1 shared publication Colin J. Sutherland
Department of Clinical Parasitology, Hospital for Tropical Diseases, London Hospitals University College NHS Foundation Trust, Mortimer Market, Capper Street, London WC1E 6JB, United Kingdom,1 Eiken Chemical Co. Ltd., 143 Nogi, Nogi-machi, Shimotsuga-gun, Tochigi, Japan,2 Foundation for Innovative New Diagnostics, Avenue de Budé 16, Geneva CH1202, Switzerland,3 HPA Malaria Reference Laboratory, London School of Hygiene and Tropical Medicine, Keppel Street, London WC1E 7HT, United Kingdom4
1 shared publication- David Bell
Independent Consultant, Lake Jackson, TX 77566, USA
1 shared publication
Latest Publications
- 1 January 2025
- Published by Springer Nature
- p. 717-728
Malaria Diagnostic Platform, LAMP
- Open Access
- 5 February 2015
- Published by Springer Nature in Malaria Journal
- Vol. 14 (1) , 1-7
The design and evaluation of a shaped filter collection device to sample and store defined volume dried blood spots from finger pricks
Dried blood spots are a common medium for collecting patient blood prior to testing for malaria by molecular methods. A new shaped filter device for the quick and simple collection of a designated volume of patient blood has been designed and tested against conventional blood spots for accuracy and precision. Shaped filter devices were laser cut from Whatman GB003 paper to absorb a 20 μl blood volume. These devices were used to sample Plasmodium falciparum infected blood and the volume absorbed was measured volumetrically. Conventional blood spots were made by pipetting 20 μl of the same blood onto Whatman 3MM paper. DNA was extracted from both types of dried blood spot using Qiagen DNA blood mini or Chelex extraction for real-time PCR analysis, and PURE extraction for malaria LAMP testing. The shaped filter devices collected a mean volume of 21.1 μl of blood, with a coefficient of variance of 8.1%. When used for DNA extraction by Chelex and Qiagen methodologies the mean number of international standard units of P. falciparum DNA recovered per μl of the eluate was 53.1 (95% CI: 49.4 to 56.7) and 32.7 (95% CI: 28.8 to 36.6), respectively for the shaped filter device, and 54.6 (95% CI: 52.1 to 57.1) and 12.0 (95% CI: 9.9 to 14.1), respectively for the 3MM blood spots. Qiagen extraction of 200 μl of whole infected blood yielded 853.6 international standard units of P. falciparum DNA per μl of eluate. A shaped filter device provides a simple way to quickly sample and store a defined volume of blood without the need for any additional measuring devices. Resultant dried blood spots may be employed for DNA extraction using a variety of technologies for nucleic acid amplification without the need for repeated cleaning of scissors or punches to prevent cross contamination of samples and results are comparable to traditional DBS.
- 5 February 2015
- Published by Springer Nature in Malaria Journal
- Vol. 14 (1) , 1-7
Open AccessThe design and evaluation of a shaped filter collection device to sample and store defined volume dried blood spots from finger pricks
Dried blood spots are a common medium for collecting patient blood prior to testing for malaria by molecular methods. A new shaped filter device for the quick and simple collection of a designated volume of patient blood has been designed and tested against conventional blood spots for accuracy and precision. Shaped filter devices were laser cut from Whatman GB003 paper to absorb a 20 μl blood volume. These devices were used to sample Plasmodium falciparum infected blood and the volume absorbed was measured volumetrically. Conventional blood spots were made by pipetting 20 μl of the same blood onto Whatman 3MM paper. DNA was extracted from both types of dried blood spot using Qiagen DNA blood mini or Chelex extraction for real-time PCR analysis, and PURE extraction for malaria LAMP testing. The shaped filter devices collected a mean volume of 21.1 μl of blood, with a coefficient of variance of 8.1%. When used for DNA extraction by Chelex and Qiagen methodologies the mean number of international standard units of P. falciparum DNA recovered per μl of the eluate was 53.1 (95% CI: 49.4 to 56.7) and 32.7 (95% CI: 28.8 to 36.6), respectively for the shaped filter device, and 54.6 (95% CI: 52.1 to 57.1) and 12.0 (95% CI: 9.9 to 14.1), respectively for the 3MM blood spots. Qiagen extraction of 200 μl of whole infected blood yielded 853.6 international standard units of P. falciparum DNA per μl of eluate. A shaped filter device provides a simple way to quickly sample and store a defined volume of blood without the need for any additional measuring devices. Resultant dried blood spots may be employed for DNA extraction using a variety of technologies for nucleic acid amplification without the need for repeated cleaning of scissors or punches to prevent cross contamination of samples and results are comparable to traditional DBS.
- 4 June 2014
- Published by Springer Nature
- p. 1-13
Malaria Diagnostic Platform, LAMP
- Open Access
- 5 March 2012
- Published by Springer Nature in Malaria Journal
- Vol. 11 (1) , 62
Increased sensitivity for detecting malaria parasites in human umbilical cord blood using scaled-up DNA preparation
All mothers donating umbilical cord blood units to the NHS cord blood bank undergo an assessment for the likelihood of prior exposure to malaria infection. Those deemed at risk due to a history of travel to, or residence in, malaria endemic regions are screened serologically to detect anti-malaria antibodies. A positive result excludes the use of the cord blood for transplant therapy unless a risk assessment can ensure that malaria transmission is extremely unlikely. This paper details the screening of cord blood units from malaria serology positive mothers to detect malaria parasite DNA using a highly sensitive nested PCR.
- 5 March 2012
- Published by Springer Nature in Malaria Journal
- Vol. 11 (1) , 62
Open AccessIncreased sensitivity for detecting malaria parasites in human umbilical cord blood using scaled-up DNA preparation
All mothers donating umbilical cord blood units to the NHS cord blood bank undergo an assessment for the likelihood of prior exposure to malaria infection. Those deemed at risk due to a history of travel to, or residence in, malaria endemic regions are screened serologically to detect anti-malaria antibodies. A positive result excludes the use of the cord blood for transplant therapy unless a risk assessment can ensure that malaria transmission is extremely unlikely. This paper details the screening of cord blood units from malaria serology positive mothers to detect malaria parasite DNA using a highly sensitive nested PCR.
- Open Access
- 5 November 2010
- Published by Springer Nature in Malaria Journal
- Vol. 9 (1) , 312
Measuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance
Background: Artemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries, may be under threat from newly emerging parasite resistance to the artemisinin family of drugs. Studies in Southeast Asia suggest some patients exhibit an extended parasite clearance time in the three days immediately following treatment with artesunate monotherapy. This phenotype is likely to become a more important trial endpoint in studies of anti-malarial drug efficacy, but currently requires frequent, closely spaced blood sampling in hospitalized study participants, followed by quantitation of parasite density by microscopy. Methods: A simple duplex quantitative PCR method was developed in which distinct fluorescent signals are generated from the human and parasite DNA components in each blood sample. The human amplification target in this assay is the β tubulin gene, and the parasite target is the unique methionine tRNA gene (pgmet), which exhibits perfect sequence identity in all six Plasmodium species that naturally infect humans. In a small series of malaria cases treated as hospital in-patients, the abundance of pgmet DNA was estimated relative to the human DNA target in daily peripheral blood samples, and parasite clearance times calculated. Results: The qPCR assay was reproducibly able to replicate parasite density estimates derived from microscopy, but provided additional data by quantification of parasite density 24 hours after the last positive blood film. Robust estimates of parasite clearance times were produced for a series of patients with clinical malaria. Conclusions: Large studies, particularly in Africa where children represent a major proportion of treated cases, will require a simpler blood sample collection regime, and a method capable of high throughput. The duplex qPCR method tested may fulfil these criteria, and should now be evaluated in such field studies.
- 5 November 2010
- Published by Springer Nature in Malaria Journal
- Vol. 9 (1) , 312
Open AccessMeasuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance
Background: Artemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries, may be under threat from newly emerging parasite resistance to the artemisinin family of drugs. Studies in Southeast Asia suggest some patients exhibit an extended parasite clearance time in the three days immediately following treatment with artesunate monotherapy. This phenotype is likely to become a more important trial endpoint in studies of anti-malarial drug efficacy, but currently requires frequent, closely spaced blood sampling in hospitalized study participants, followed by quantitation of parasite density by microscopy. Methods: A simple duplex quantitative PCR method was developed in which distinct fluorescent signals are generated from the human and parasite DNA components in each blood sample. The human amplification target in this assay is the β tubulin gene, and the parasite target is the unique methionine tRNA gene (pgmet), which exhibits perfect sequence identity in all six Plasmodium species that naturally infect humans. In a small series of malaria cases treated as hospital in-patients, the abundance of pgmet DNA was estimated relative to the human DNA target in daily peripheral blood samples, and parasite clearance times calculated. Results: The qPCR assay was reproducibly able to replicate parasite density estimates derived from microscopy, but provided additional data by quantification of parasite density 24 hours after the last positive blood film. Robust estimates of parasite clearance times were produced for a series of patients with clinical malaria. Conclusions: Large studies, particularly in Africa where children represent a major proportion of treated cases, will require a simpler blood sample collection regime, and a method capable of high throughput. The duplex qPCR method tested may fulfil these criteria, and should now be evaluated in such field studies.
- Open Access
- 1 August 2010
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 48 (8) , 2866-2871
Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification
Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays.
- 1 August 2010
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 48 (8) , 2866-2871
Open AccessMitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification
Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays.