Marc Roger Couturier
Research Subjects
Marc Roger Couturier has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Blaine A. Mathison
Department of Pathology, University of Utah
5 shared publications - James J. Dunn
Baylor College of Medicine, Texas Children’s Hospital
5 shared publications - Angela Ma
University of Toronto
4 shared publications - Audrey N. Schuetz
Department of Laboratory Medicine and Pathology, Mayo Clinic
4 shared publications - Cameron August Brown
Baylor College of Medicine
3 shared publications Santiago Delgado Fernandez
3 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 64 (7) , e0016526
Diagnosing helminth infections in a large reference laboratory in the United States: a 6-month pre- and post-implementation analysis of AI-augmented screening of concentrated fecal wet mounts
Helminth infections are uncommon in the United States, yet accurate detection remains critical. Conventional ova-and-parasite examinations are labor-intensive and prone to error in low-prevalence settings. We evaluated the impact of implementing an artificial intelligence (AI)-based wet mount screening platform (WM-AI) in a high-volume reference laboratory. Detection rates, turnaround times, and specimen characteristics were compared across two 6-month periods before and after WM-AI implementation. Post-implementation, helminth detection increased from 29 to 104 patients, and client-level positivity rose from 4.5% to 12.3% ( P < 0.0001). Enterobius vermicularis showed a fivefold increase in positivity (0.03% vs 0.15%, P < 0.0001). Median turnaround time improved from 5.2 to 4.0 days ( P < 0.0001). Most infections were identified in the first or only specimen submitted, and over half of positive specimens contained ≤5 eggs or larvae, highlighting the challenge of detecting low-intensity infections. AI-assisted screening enhanced operational efficiency and diagnostic yield, suggesting improved sensitivity for low-burden infections. These findings support the integration of AI tools in parasitology workflows. IMPORTANCE: The data presented in our manuscript are observational after adopting a more sensitive assay in our parasitology workflow, specifically the use of artificial intelligence (AI) to pre-screen concentrated stool specimens for parasites. The notable increase in the positivity of helminth cases in our lab, which is a large reference laboratory, indicates that adopting AI as a screening tool in a parasitology laboratory can increase sensitivity of pathogenic parasites, especially helminths.
- 8 July 2026
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 64 (7) , e0016526
Open AccessDiagnosing helminth infections in a large reference laboratory in the United States: a 6-month pre- and post-implementation analysis of AI-augmented screening of concentrated fecal wet mounts
Helminth infections are uncommon in the United States, yet accurate detection remains critical. Conventional ova-and-parasite examinations are labor-intensive and prone to error in low-prevalence settings. We evaluated the impact of implementing an artificial intelligence (AI)-based wet mount screening platform (WM-AI) in a high-volume reference laboratory. Detection rates, turnaround times, and specimen characteristics were compared across two 6-month periods before and after WM-AI implementation. Post-implementation, helminth detection increased from 29 to 104 patients, and client-level positivity rose from 4.5% to 12.3% ( P < 0.0001). Enterobius vermicularis showed a fivefold increase in positivity (0.03% vs 0.15%, P < 0.0001). Median turnaround time improved from 5.2 to 4.0 days ( P < 0.0001). Most infections were identified in the first or only specimen submitted, and over half of positive specimens contained ≤5 eggs or larvae, highlighting the challenge of detecting low-intensity infections. AI-assisted screening enhanced operational efficiency and diagnostic yield, suggesting improved sensitivity for low-burden infections. These findings support the integration of AI tools in parasitology workflows. IMPORTANCE: The data presented in our manuscript are observational after adopting a more sensitive assay in our parasitology workflow, specifically the use of artificial intelligence (AI) to pre-screen concentrated stool specimens for parasites. The notable increase in the positivity of helminth cases in our lab, which is a large reference laboratory, indicates that adopting AI as a screening tool in a parasitology laboratory can increase sensitivity of pathogenic parasites, especially helminths.
- 5 March 2025
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 112 (3) , 533-538
Comparison of Paired Immunofluorescent Antibody Serology and Real-Time Polymerase Chain Reaction Testing for the Detection of Acute Q Fever among Febrile Patients in Kilimanjaro, Tanzania, 2012–2014
: Acute Q fever diagnosis via paired serology is problematic because it requires follow-up for convalescent sample collection; as such, it cannot provide a diagnosis to inform a treatment decision at the time of acute presentation. Real-time polymerase chain reaction (PCR) may be a useful approach for the diagnosis of acute Q fever in endemic settings. Among febrile patients enrolled in a sentinel surveillance study for Q fever at two referral hospitals in Moshi, Tanzania, from 2012 to 2014, we analyzed those with paired sera for IgG to Coxiella burnetii (C. burnetii) phase II antigens using immunofluorescent antibody (IFA) testing, and acute serum was tested for C. burnetii with PCR. Acute Q fever was defined as a fourfold or greater rise from the acute to convalescent sample in IFA reciprocal titer or PCR detection that was confirmed through repeat testing. Test characteristics were tabulated. Among 496 participants tested using both paired IFA and PCR testing, 463 (93.3%) tested negative on both IFA and PCR, five (1.0%) tested positive for Q fever on both IFA and PCR, and 28 (5.6%) tested positive for Q fever on IFA alone. The sensitivity of PCR testing using paired IFA testing as an index was 0.15 (5/33), and the specificity was 1 (463/463). C. burnetii PCR testing provides a clinically specific method that may aid in timely diagnosis in settings in which acute Q fever is a common cause of febrile illness. However, we found a low clinical sensitivity of PCR testing on serum when compared with paired IFA serology.
- 5 March 2025
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 112 (3) , 533-538
Comparison of Paired Immunofluorescent Antibody Serology and Real-Time Polymerase Chain Reaction Testing for the Detection of Acute Q Fever among Febrile Patients in Kilimanjaro, Tanzania, 2012–2014
: Acute Q fever diagnosis via paired serology is problematic because it requires follow-up for convalescent sample collection; as such, it cannot provide a diagnosis to inform a treatment decision at the time of acute presentation. Real-time polymerase chain reaction (PCR) may be a useful approach for the diagnosis of acute Q fever in endemic settings. Among febrile patients enrolled in a sentinel surveillance study for Q fever at two referral hospitals in Moshi, Tanzania, from 2012 to 2014, we analyzed those with paired sera for IgG to Coxiella burnetii (C. burnetii) phase II antigens using immunofluorescent antibody (IFA) testing, and acute serum was tested for C. burnetii with PCR. Acute Q fever was defined as a fourfold or greater rise from the acute to convalescent sample in IFA reciprocal titer or PCR detection that was confirmed through repeat testing. Test characteristics were tabulated. Among 496 participants tested using both paired IFA and PCR testing, 463 (93.3%) tested negative on both IFA and PCR, five (1.0%) tested positive for Q fever on both IFA and PCR, and 28 (5.6%) tested positive for Q fever on IFA alone. The sensitivity of PCR testing using paired IFA testing as an index was 0.15 (5/33), and the specificity was 1 (463/463). C. burnetii PCR testing provides a clinically specific method that may aid in timely diagnosis in settings in which acute Q fever is a common cause of febrile illness. However, we found a low clinical sensitivity of PCR testing on serum when compared with paired IFA serology.
- Open Access
- 31 January 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (1) , e0108424
Shedding new light on Cyclospora : how the use of ultraviolet fluorescence microscopy can improve diagnosis of cyclosporiasis
Cyclosporiasis has historically been underdiagnosed due to a lack of clinical recognition and challenges in laboratory detection. Microscopic detection of Cyclospora requires either the modified Kinyoun’s acid-fast or safranin stains, which are not part of the standard ova-and-parasite examination. Alternatively, the use of fluorescence microscopy for the detection of Cyclospora due to the organism’s autofluorescent properties has been an available tool in the field of clinical parasitology. However, it is unknown how ultraviolet (UV) fluorescence performs compared to permanent stains in routine diagnostic laboratory settings. In this study, we present a direct head-to-head comparison of UV fluorescence against modified acid-fast (MAF) stains using 50 (35 Cyclospora positive, 5 Cystoisospora positive, and 10 Cystoisospora negative) blinded, concentrated stool specimens. Five technically competent medical laboratory technologists of varying years of experience in clinical parasitology at a large reference laboratory independently read each of the MAF slides and UV wet mounts. Overall, the performance of UV fluorescence was similar to MAF slides with a higher agreement of 88.8% (95% CI 86.3%–91.3%) compared to 85.2% (95% CI 84.2%–86.2%), respectively. A higher false-negative rate was associated with MAF slides (MAF: 11.6%, UV: 6.8%). However, UV fluorescence was found to have a higher proportion of false positives (UF: 3.2%, MAF: 2%) and misidentified coccidia. Discrepant results regardless of methods were more frequently observed with technologists who have less experience in parasite morphology. This study is the first to document evidence to support the increased sensitivity and utility of UV fluorescence to improve laboratory diagnosis of cyclosporiasis. IMPORTANCE: This study is important as there is a dearth of studies in our field of clinical parasitology that investigate and establish performance characteristics of classic and newer, non-molecular methods. While these studies may not seem as heavy hitting as some new technologies described in our related disciplines, for our field, such studies are long overdue and critically lacking.
- 31 January 2025
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 63 (1) , e0108424
Open AccessShedding new light on Cyclospora : how the use of ultraviolet fluorescence microscopy can improve diagnosis of cyclosporiasis
Cyclosporiasis has historically been underdiagnosed due to a lack of clinical recognition and challenges in laboratory detection. Microscopic detection of Cyclospora requires either the modified Kinyoun’s acid-fast or safranin stains, which are not part of the standard ova-and-parasite examination. Alternatively, the use of fluorescence microscopy for the detection of Cyclospora due to the organism’s autofluorescent properties has been an available tool in the field of clinical parasitology. However, it is unknown how ultraviolet (UV) fluorescence performs compared to permanent stains in routine diagnostic laboratory settings. In this study, we present a direct head-to-head comparison of UV fluorescence against modified acid-fast (MAF) stains using 50 (35 Cyclospora positive, 5 Cystoisospora positive, and 10 Cystoisospora negative) blinded, concentrated stool specimens. Five technically competent medical laboratory technologists of varying years of experience in clinical parasitology at a large reference laboratory independently read each of the MAF slides and UV wet mounts. Overall, the performance of UV fluorescence was similar to MAF slides with a higher agreement of 88.8% (95% CI 86.3%–91.3%) compared to 85.2% (95% CI 84.2%–86.2%), respectively. A higher false-negative rate was associated with MAF slides (MAF: 11.6%, UV: 6.8%). However, UV fluorescence was found to have a higher proportion of false positives (UF: 3.2%, MAF: 2%) and misidentified coccidia. Discrepant results regardless of methods were more frequently observed with technologists who have less experience in parasite morphology. This study is the first to document evidence to support the increased sensitivity and utility of UV fluorescence to improve laboratory diagnosis of cyclosporiasis. IMPORTANCE: This study is important as there is a dearth of studies in our field of clinical parasitology that investigate and establish performance characteristics of classic and newer, non-molecular methods. While these studies may not seem as heavy hitting as some new technologies described in our related disciplines, for our field, such studies are long overdue and critically lacking.
- 31 October 2024
- Published by Springer Nature
- p. 81-112
Virology Cases
- 31 October 2024
- Published by Springer Nature
- p. 211-233
Rare and Notable Cases
- 31 October 2024
- Published by Springer Nature
- p. 159-209
Parasitology Cases
- 31 October 2024
- Published by Springer Nature
- p. 113-158
Mycology Cases
- 31 October 2024
- Published by Springer Nature
- p. 1-80
Bacteriology and Mycobacteriology Cases
- 13 March 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (3) , e0126023
Photo Quiz: An ear-resistible occupant in a 73-year-old patient
- 13 March 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (3) , e0126023
Photo Quiz: An ear-resistible occupant in a 73-year-old patient
- 13 March 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (3) , e0126123
Answer to March 2024 Photo Quiz
Read the full article for the answer.
- 13 March 2024
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 62 (3) , e0126123
Answer to March 2024 Photo Quiz
Read the full article for the answer.