Delphine Martiny
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Delphine Martiny has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
O. Vandenberg
Saint‐Pierre University Hospital and Jules Bordet Institute Department of Microbiology Brussels Belgium
6 shared publicationsA. Dediste
Saint‐Pierre University Hospital and Jules Bordet Institute Department of Microbiology Brussels Belgium
4 shared publicationsOlivier Vandenberg
Department of Microbiology, iris-Lab, Iris-Brussels Public Hospital Network, Brussels, Belgium; Infectious Diseases Epidemiological Unit, Public Health School, Université Libre de Bruxelles, Brussels, Belgium
3 shared publicationsAnne Dediste
Department of Microbiology, iris-Lab, Iris-Brussels Public Hospital Network, Brussels, Belgium
2 shared publicationsL. Vlaes
2 shared publicationsA. Cornelius
1 shared publication
Latest Publications
- 1 October 2016
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 86 (2) , 128-130
Performance of the chromID Salmonella Elite chromogenic agar in comparison with CHROMagar™ Salmonella , Oxoid™ Brilliance™ Salmonella and Hektoen agars for the isolation of Salmonella from stool specimens
- 1 October 2016
- Published by Elsevier in Diagnostic Microbiology and Infectious Disease
- Vol. 86 (2) , 128-130
Performance of the chromID Salmonella Elite chromogenic agar in comparison with CHROMagar™ Salmonella , Oxoid™ Brilliance™ Salmonella and Hektoen agars for the isolation of Salmonella from stool specimens
- Open Access
- 1 December 2013
- Published by Elsevier in Clinical Microbiology and Infection
- Vol. 19 (12) , E568-E581
Impact of rapid microbial identification directly from positive blood cultures using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry on patient management
- 1 December 2013
- Published by Elsevier in Clinical Microbiology and Infection
- Vol. 19 (12) , E568-E581
Open AccessImpact of rapid microbial identification directly from positive blood cultures using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry on patient management
- 27 September 2013
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 33 (4) , 529-536
Subtype determination of Blastocystis isolates by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS)
The pathogenic role of the enteric parasite Blastocystis remains controversial. Recent studies have suggested that various subtypes (STs) found in human samples could be correlated to the presence or absence and variability of clinical manifestations, and that STs can differ with respect to drug sensitivity. Polymerase chain reaction (PCR) techniques used to determine these STs are expensive and are usually restricted to research laboratory settings. This study evaluates the potential application of the inexpensive matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) technique to discriminate Blastocystis STs. A database of parasitic protein signatures was constructed for five Blastocystis STs, and the reference spectra were challenged with those from 19 axenic cultures of ST1, ST2, ST3, ST4 and ST8 and those from nine xenic liquid cultures of ST3 and ST4. Samples from axenic cultures were prepared using standard formic acid extraction and direct deposition procedures. The reference spectra revealed five distinct spectral profiles, and the database library allowed for discrimination between all of the cultures with reliability indices ranging from 2.038 to greater than 2.8 when an extraction was performed. The direct deposition procedure resulted in greater variability in the discrimination and direct MALDI-TOF MS identification from xenic liquid cultures was effective in 3 out of 9 samples. MALDI-TOF MS proved to be an effective technology for efficiently discriminating Blastocystis STs in axenic cultures.
- 27 September 2013
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 33 (4) , 529-536
Subtype determination of Blastocystis isolates by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS)
The pathogenic role of the enteric parasite Blastocystis remains controversial. Recent studies have suggested that various subtypes (STs) found in human samples could be correlated to the presence or absence and variability of clinical manifestations, and that STs can differ with respect to drug sensitivity. Polymerase chain reaction (PCR) techniques used to determine these STs are expensive and are usually restricted to research laboratory settings. This study evaluates the potential application of the inexpensive matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) technique to discriminate Blastocystis STs. A database of parasitic protein signatures was constructed for five Blastocystis STs, and the reference spectra were challenged with those from 19 axenic cultures of ST1, ST2, ST3, ST4 and ST8 and those from nine xenic liquid cultures of ST3 and ST4. Samples from axenic cultures were prepared using standard formic acid extraction and direct deposition procedures. The reference spectra revealed five distinct spectral profiles, and the database library allowed for discrimination between all of the cultures with reliability indices ranging from 2.038 to greater than 2.8 when an extraction was performed. The direct deposition procedure resulted in greater variability in the discrimination and direct MALDI-TOF MS identification from xenic liquid cultures was effective in 3 out of 9 samples. MALDI-TOF MS proved to be an effective technology for efficiently discriminating Blastocystis STs in axenic cultures.
- 1 September 2013
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 94 (3) , 221-223
Optimization of Campylobacter growth conditions for further identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)
- 1 September 2013
- Published by Elsevier in Journal of Microbiological Methods
- Vol. 94 (3) , 221-223
Optimization of Campylobacter growth conditions for further identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)
- Open Access
- 1 June 2012
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 16, e399-e400
Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF-MS) for strain-typing of Campylobacter jejuni
- 1 June 2012
- Published by Elsevier in International Journal of Infectious Diseases
- Vol. 16, e399-e400
Open AccessMatrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF-MS) for strain-typing of Campylobacter jejuni
- 1 April 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (4) , 1313-1325
Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
This study compared the performance of three matrix-assisted laser desorption ionization–time of flight mass spectrometry systems: Microflex LT (Bruker Daltonics, Bremen, Germany), Vitek MS RUO (Axima Assurance-Saramis database; bioMérieux, Marcy l'Etoile, France), and Vitek MS IVD (bioMérieux). A total of 1,129 isolates, including 1,003 routine isolates, 73 anaerobes, and 53 bacterial enteropathogens, were tested on the Microflex LT and Axima Assurance devices. The spectra were analyzed using three databases: Biotyper (Bruker Daltonics), Saramis, and Vitek MS (bioMérieux). Among the routine isolates requiring identification to the species level ( n = 986), 92.7% and 93.2% were correctly identified by the Biotyper and Vitek MS databases, respectively. The Vitek MS database is more specific for the identification of Streptococcus viridans . For the anaerobes, the Biotyper database often identified Fusobacterium isolates to only the genus level, which is of low clinical significance, whereas 20% of the Bacteroides species were not identified or were misidentified by the Vitek MS database. For the enteropathogens, the poor discrimination between Escherichia coli and Shigella explains the high proportion of unidentified organisms. In contrast to the Biotyper database, the Vitek MS database properly discriminated all of the Salmonella entrica serovar Typhi isolates ( n = 5). The performance of the Saramis database was globally poorer. In conclusion, for routine procedures, the Microflex LT and Vitek-MS systems are equally good choices in terms of analytical efficiency. Other factors, including price, work flow, and lab activity, will affect the choice of a system.
- 1 April 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (4) , 1313-1325
Comparison of the Microflex LT and Vitek MS Systems for Routine Identification of Bacteria by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
This study compared the performance of three matrix-assisted laser desorption ionization–time of flight mass spectrometry systems: Microflex LT (Bruker Daltonics, Bremen, Germany), Vitek MS RUO (Axima Assurance-Saramis database; bioMérieux, Marcy l'Etoile, France), and Vitek MS IVD (bioMérieux). A total of 1,129 isolates, including 1,003 routine isolates, 73 anaerobes, and 53 bacterial enteropathogens, were tested on the Microflex LT and Axima Assurance devices. The spectra were analyzed using three databases: Biotyper (Bruker Daltonics), Saramis, and Vitek MS (bioMérieux). Among the routine isolates requiring identification to the species level ( n = 986), 92.7% and 93.2% were correctly identified by the Biotyper and Vitek MS databases, respectively. The Vitek MS database is more specific for the identification of Streptococcus viridans . For the anaerobes, the Biotyper database often identified Fusobacterium isolates to only the genus level, which is of low clinical significance, whereas 20% of the Bacteroides species were not identified or were misidentified by the Vitek MS database. For the enteropathogens, the poor discrimination between Escherichia coli and Shigella explains the high proportion of unidentified organisms. In contrast to the Biotyper database, the Vitek MS database properly discriminated all of the Salmonella entrica serovar Typhi isolates ( n = 5). The performance of the Saramis database was globally poorer. In conclusion, for routine procedures, the Microflex LT and Vitek-MS systems are equally good choices in terms of analytical efficiency. Other factors, including price, work flow, and lab activity, will affect the choice of a system.
- 25 February 2012
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 31 (9) , 2269-2281
Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry
The identification of bacteria directly from positive blood cultures using matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a new challenge to microbiologists. However, the protocols previously described are often difficult to implement in routine and comparisons are not always possible due to the variability of interpretative criteria. This study evaluated the analytical and practical performances of an in-house (IH) method, adapted from previous protocols, and the Sepsityper™ kit (Bruker Daltonics, Bremen, Germany). Positive blood cultures from 63 different patients were prospectively evaluated by both methods. To enhance the sensitivity of these methods, lowered cut-offs were assessed and validated on 66 additional samples. The IH method produced 86.4% and 73.7% correct genus and species identifications, respectively, when using the lowered cut-offs of 1.4 and 1.6 for correct genus and species identifications. The Sepsityper™ kit showed similar results (78.0% and 68.4% correct genus and species identification, respectively). However, the IH method is ten-fold less expensive than the commercial option (0.72 vs. 7.45 €/analysis) and its turnaround time is approximately 20 min versus the nearly 40 min required for the Sepsityper™ kit, which includes an extraction step. Finally, the IH method was introduced twice-daily in our routine practice.
- 25 February 2012
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 31 (9) , 2269-2281
Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry
The identification of bacteria directly from positive blood cultures using matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a new challenge to microbiologists. However, the protocols previously described are often difficult to implement in routine and comparisons are not always possible due to the variability of interpretative criteria. This study evaluated the analytical and practical performances of an in-house (IH) method, adapted from previous protocols, and the Sepsityper™ kit (Bruker Daltonics, Bremen, Germany). Positive blood cultures from 63 different patients were prospectively evaluated by both methods. To enhance the sensitivity of these methods, lowered cut-offs were assessed and validated on 66 additional samples. The IH method produced 86.4% and 73.7% correct genus and species identifications, respectively, when using the lowered cut-offs of 1.4 and 1.6 for correct genus and species identifications. The Sepsityper™ kit showed similar results (78.0% and 68.4% correct genus and species identification, respectively). However, the IH method is ten-fold less expensive than the commercial option (0.72 vs. 7.45 €/analysis) and its turnaround time is approximately 20 min versus the nearly 40 min required for the Sepsityper™ kit, which includes an extraction step. Finally, the IH method was introduced twice-daily in our routine practice.
- 1 July 2011
- Published by Elsevier in Clinical Microbiology and Infection
- Vol. 17 (7) , 1001-1006
Accuracy of the API Campy system, the Vitek 2 Neisseria–Haemophilus card and matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the identification of Campylobacter and related organisms
- 1 July 2011
- Published by Elsevier in Clinical Microbiology and Infection
- Vol. 17 (7) , 1001-1006
Accuracy of the API Campy system, the Vitek 2 Neisseria–Haemophilus card and matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the identification of Campylobacter and related organisms