KGK. A. Goatman

K. A. Goatman

*This is an algorithmically generated author record based on publicly available information.

K. A. Goatman has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Improving the economic value of photographic screening for optical coherence tomography-detectable macular oedema: a prospective, multicentre, UK study

    by J Olson, P Sharp, K Goatman, G Prescott, G Scotland, A Fleming, S Philip, C Santiago, S Borooah, D Broadbent, et al.

    Objectives To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. Design A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. Setting All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. Participants Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. Interventions Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. Main outcome measures (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). Results Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Conclusions Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Study registration This study has been registered as REC/IRAS 07/S0801/107, UKCRN ID 9063 and NIHR HTA 06/402/49. Source of funding This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 51. See the HTA programme website for further project information.


  • External quality assurance for image grading in the Scottish Diabetic Retinopathy Screening Programme

    by K. A. Goatman, S. Philip, A. D. Fleming, R. D. Harvey, K. K. Swa, C. Styles, M. Black, G. Sell, N. Lee, P. F. Sharp, et al.

    Diabet. Med. 29, 776–783 (2012) Abstract Aims To develop and evaluate an image grading external quality assurance system for the Scottish Diabetic Retinopathy Screening Programme. Method A web‐based image grading system was developed which closely matches the current Scottish national screening software. Two rounds of external quality assurance were run in autumn 2008 and spring 2010, each time using the same 100 images. Graders were compared with a consensus standard derived from the top‐level graders’ results. After the first round, the centre lead clinicians and top‐level graders reviewed the results and drew up guidance notes for the second round. Results Grader sensitivities ranged from 60.0 to 100% (median 92.5%) in 2008, and from 62.5 to 100% (median 92.5%) in 2010. Specificities ranged from 34.0 to 98.0% (median 86%) in 2008, and 54.0 to 100% (median 88%) in 2010. There was no difference in sensitivity between grader levels, but first‐level graders had a significantly lower specificity than level‐two and level‐three graders. In 2008, one centre had a lower sensitivity but higher specificity than the majority of centres. Following the feedback from the first round, overall agreement improved in 2010 and there were no longer any significant differences between centres. Conclusions A useful educational tool has been developed for image grading external quality assurance.


  • Detection of New Vessels on the Optic Disc Using Retinal Photographs

    by K A Goatman, Alan D. Fleming, Sam Philip, Graeme J. Williams, J A Olson, Peter F. Sharp

    Proliferative diabetic retinopathyis a rare condition likely to lead to severe visual impairment. It is characterized by the development of abnormal new retinal vessels. We describe a method for automatically detecting new vessels on the optic disc using retinal photography. Vessel-like candidate segments are first detected using a method based on watershed lines and ridge strength measurement. Fifteen feature parameters, associated with shape, position, orientation, brightness, contrast and line density are calculated for each candidate segment. Based on these features, each segment is categorized as normal or abnormal using a support vector machine (SVM) classifier. The system was trained and tested by cross-validation using 38 images with new vessels and 71 normal images from two diabetic retinal screening centers and one hospital eye clinic. The discrimination performance of the fifteen features was tested against a clinical reference standard. Fourteen features were found to be effective and used in the final test. The area under the receiver operator characteristic curve was 0.911 for detecting images with new vessels on the disc. This accuracy may be sufficient for it to play a useful clinical role in an automated retinopathy analysis system.


  • A reference standard for the measurement of macular oedema

    by K A Goatman

    Macular oedema is associated with several conditions that lead to blindness. Accurate measurement of macular thickness is important in order to follow disease progression and evaluate treatments. Four techniques are examined to determine the best reference standard for the detection and quantification of macular oedema: ultrasound, optical coherence tomography, the retinal thickness analyser, and the scanning laser ophthalmoscope. The three optical techniques have the highest resolution and sensitivity, in particular optical coherence tomography. Ultrasound can be useful where dense opacities preclude optical imaging.