JFJames F. Fries

James F. Fries

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James F. Fries has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cardiovascular health in young and middle adulthood and medical care utilization and costs at older age – The Chicago Heart Association Detection Project Industry (CHA)

    by Cuiping Schiman, Lei Liu, Ya-Chen Tina Shih, Lihui Zhao, Martha L. Daviglus, Kiang Liu, James Fries, Daniel B. Garside, Thanh-Huyen T. Vu, Jeremiah Stamler, et al.


  • Open Access

    Varying the item format improved the range of measurement in patient-reported outcome measures assessing physical function

    by Gregor Liegl, Barbara Gandek, H. Felix Fischer, Jakob B. Bjorner, John E. Ware, Matthias Rose, James F. Fries, Sandra Nolte

    Physical function (PF) is a core patient-reported outcome domain in clinical trials in rheumatic diseases. Frequently used PF measures have ceiling effects, leading to large sample size requirements and low sensitivity to change. In most of these instruments, the response category that indicates the highest PF level is the statement that one is able to perform a given physical activity without any limitations or difficulty. This study investigates whether using an item format with an extended response scale, allowing respondents to state that the performance of an activity is easy or very easy, increases the range of precise measurement of self-reported PF. Three five-item PF short forms were constructed from the Patient-Reported Outcomes Measurement Information System (PROMIS®) wave 1 data. All forms included the same physical activities but varied in item stem and response scale: format A (“Are you able to …”; “without any difficulty”/“unable to do”); format B (“Does your health now limit you …”; “not at all”/“cannot do”); format C (“How difficult is it for you to …”; “very easy”/“impossible”). Each short-form item was answered by 2217–2835 subjects. We evaluated unidimensionality and estimated a graded response model for the 15 short-form items and remaining 119 items of the PROMIS PF bank to compare item and test information for the short forms along the PF continuum. We then used simulated data for five groups with different PF levels to illustrate differences in scoring precision between the short forms using different item formats. Sufficient unidimensionality of all short-form items and the original PF item bank was supported. Compared to formats A and B, format C increased the range of reliable measurement by about 0.5 standard deviations on the positive side of the PF continuum of the sample, provided more item information, and was more useful in distinguishing known groups with above-average functioning. Using an item format with an extended response scale is an efficient option to increase the measurement range of self-reported physical function without changing the content of the measure or affecting the latent construct of the instrument.


  • Open Access

    Development and assessment of floor and ceiling items for the PROMIS physical function item bank

    by Bonnie Bruce, James Fries, Bharathi Lingala, Yusra Nazar Hussain, Eswar Krishnan

    Introduction: Disability and Physical Function (PF) outcome assessment has had limited ability to measure functional status at the floor (very poor functional abilities) or the ceiling (very high functional abilities). We sought to identify, develop and evaluate new floor and ceiling items to enable broader and more precise assessment of PF outcomes for the NIH Patient-Reported-Outcomes Measurement Information System (PROMIS). Methods: We conducted two cross-sectional studies using NIH PROMIS item improvement protocols with expert review, participant survey and focus group methods. In Study 1, respondents with low PF abilities evaluated new floor items, and those with high PF abilities evaluated new ceiling items for clarity, importance and relevance. In Study 2, we compared difficulty ratings of new floor items by low functioning respondents and ceiling items by high functioning respondents to reference PROMIS PF-10 items. We used frequencies, percentages, means and standard deviations to analyze the data. Results: In Study 1, low (n = 84) and high (n = 90) functioning respondents were mostly White, women, 70 years old, with some college, and disability scores of 0.62 and 0.30. More than 90% of the 31 new floor and 31 new ceiling items were rated as clear, important and relevant, leaving 26 ceiling and 30 floor items for Study 2. Low (n = 246) and high (n = 637) functioning Study 2 respondents were mostly White, women, 70 years old, with some college, and Health Assessment Questionnaire (HAQ) scores of 1.62 and 0.003. Compared to difficulty ratings of reference items, ceiling items were rated to be 10% more to greater than 40% more difficult to do, and floor items were rated to be about 12% to nearly 90% less difficult to do. Conclusions: These new floor and ceiling items considerably extend the measurable range of physical function at either extreme. They will help improve instrument performance in populations with broad functional ranges and those concentrated at one or the other extreme ends of functioning. Optimal use of these new items will be assisted by computerized adaptive testing (CAT), reducing questionnaire burden and insuring item administration to appropriate individuals.


  • Open Access

    The Theory and Practice of Active Aging

    by James F. Fries

    “Active aging” connotes a radically nontraditional paradigm of aging which posits possible improvement in health despite increasing longevity. The new paradigm is based upon postponing functional declines more than mortality declines and compressing morbidity into a shorter period later in life. This paradigm (Compression of Morbidity) contrasts with the old, where increasing longevity inevitably leads to increasing morbidity. We have focused our research on controlled longitudinal studies of aging. The Runners and Community Controls study began at age 58 in 1984 and the Health Risk Cohorts study at age 70 in 1986. We noted that disability was postponed by 14 to 16 years in vigorous exercisers compared with controls and postponed by 10 years in low-risk cohorts compared with higher risk. Mortality was also postponed, but too few persons had died for valid comparison of mortality and morbidity. With the new data presented here, age at death at 30% mortality is postponed by 7 years in Runners and age at death at 50% (median) mortality by 3.3 years compared to controls. Postponement of disability is more than double that of mortality in both studies. These differences increase over time, occur in all subgroups, and persist after statistical adjustment.


  • Open Access

    Improved responsiveness and reduced sample size requirements of PROMIS physical function scales with item response theory

    by James F Fries, Eswar Krishnan, Matthias Rose, Bharathi Lingala, Bonnie Bruce

    Introduction: The Health Assessment Questionnaire Disability Index (HAQ) and the SF-36 PF-10, among other instruments, yield sensitive and valid Disability (Physical Function) endpoints. Modern techniques, such as Item Response Theory (IRT), now enable development of more precise instruments using improved items. The NIH Patient Reported Outcomes Measurement Information System (PROMIS) is charged with developing improved IRT-based tools. We compared the ability to detect change in physical function using original (Legacy) instruments with Item-Improved and PROMIS IRT-based instruments. Methods: We studied two Legacy (original) Physical Function/Disability instruments (HAQ, PF-10), their item-improved derivatives (Item-Improved HAQ and PF-10), and the IRT-based PROMIS Physical Function 10- (PROMIS PF 10) and 20-item (PROMIS PF 20) instruments. We compared sensitivity to detect 12-month changes in physical function in 451 rheumatoid arthritis (RA) patients and assessed relative responsiveness using P-values, effect sizes (ES), and sample size requirements. Results: The study sample was 81% female, 87% Caucasian, 65 years of age, had 14 years of education, and had moderate baseline disability. All instruments were sensitive to detecting change (< 0.05) in physical function over one year. The most responsive instruments in these patients were the Item-Improved HAQ and the PROMIS PF 20. IRT-improved instruments could detect a 1.2% difference with 80% power, while reference instruments could detect only a 2.3% difference (P < 0.01). The best IRT-based instruments required only one-quarter of the sample sizes of the Legacy (PF-10) comparator (95 versus 427). The HAQ outperformed the PF-10 in more impaired populations; the reverse was true in more normal populations. Considering especially the range of severity measured, the PROMIS PF 20 appears the most responsive instrument. Conclusions: Physical Function scales using item improved or IRT-based items can result in greater responsiveness and precision across a broader range of physical function. This can reduce sample size requirements and thus study costs.


  • The PROMIS of Better Outcome Assessment: Responsiveness, Floor and Ceiling Effects, and Internet Administration

    by James Fries, Matthias Rose, Eswar Krishnan

    Objective.: Use of item response theory (IRT) and, subsequently, computerized adaptive testing (CAT), under the umbrella of the NIH-PROMIS initiative (National Institutes of Health – Patient-Reported Outcomes Measurement Information System), to bring strong new assets to the development of more sensitive, more widely applicable, and more efficiently administered patient-reported outcome (PRO) instruments. We present data on current progress in 3 crucial areas: floor and ceiling effects, responsiveness to change, and interactive computer-based administration over the Internet.Methods.: We examined nearly 1000 patients with rheumatoid arthritis and related diseases in a series of studies including a one-year longitudinal examination of detection of change; compared responsiveness of the Legacy SF-36 and HAQ-DI instruments with IRT-based instruments; performed a randomized head-to-head trial of 4 modes of item administration; and simulated the effect of lack of floor and ceiling items upon statistical power and sample sizes.Results.: IRT-based PROMIS instruments are more sensitive to change, resulting in the potential to reduce sample size requirements substantially by up to a factor of 4. The modes of administration tested did not differ from each other in any instance by more than one-tenth of a standard deviation. Floor and ceiling effects greatly reduce the number of available subjects, particularly at the ceiling.Conclusion.: Failure to adequately address floor and ceiling effects, which determine the range of an instrument, can result in suboptimal assessment of many patients. Improved items, improved instruments, and computer-based administration improve PRO assessment and represent a fundamental advance in clinical outcomes research.


  • Open Access

    Compression of Morbidity 1980–2011: A Focused Review of Paradigms and Progress

    by James F. Fries, Bonnie Bruce, Eliza Chakravarty

    The Compression of Morbidity hypothesis—positing that the age of onset of chronic illness may be postponed more than the age at death and squeezing most of the morbidity in life into a shorter period with less lifetime disability—was introduced by our group in 1980. This paper is focused upon the evolution of the concept, the controversies and responses, the supportive multidisciplinary science, and the evolving lines of evidence that establish proof of concept. We summarize data from 20-year prospective longitudinal studies of lifestyle progression of disability, national population studies of trends in disability, and randomized controlled trials of risk factor reduction with life-style-based “healthy aging” interventions. From the perspective of this influential and broadly cited paradigm, we review its current history, the development of a theoretical structure for healthy aging, and the challenges to develop coherent health policies directed at reduction in morbidity.


  • Open Access

    Better assessment of physical function: item improvement is neglected but essential

    by Bonnie Bruce, James F Fries, Debbie Ambrosini, Bharathi Lingala, Barbara Gandek, Matthias Rose, John E Ware

    Introduction: Physical function is a key component of patient-reported outcome (PRO) assessment in rheumatology. Modern psychometric methods, such as Item Response Theory (IRT) and Computerized Adaptive Testing, can materially improve measurement precision at the item level. We present the qualitative and quantitative item-evaluation process for developing the Patient Reported Outcomes Measurement Information System (PROMIS) Physical Function item bank. Methods: The process was stepwise: we searched extensively to identify extant Physical Function items and then classified and selectively reduced the item pool. We evaluated retained items for content, clarity, relevance and comprehension, reading level, and translation ease by experts and patient surveys, focus groups, and cognitive interviews. We then assessed items by using classic test theory and IRT, used confirmatory factor analyses to estimate item parameters, and graded response modeling for parameter estimation. We retained the 20 Legacy (original) Health Assessment Questionnaire Disability Index (HAQ-DI) and the 10 SF-36's PF-10 items for comparison. Subjects were from rheumatoid arthritis, osteoarthritis, and healthy aging cohorts (n = 1,100) and a national Internet sample of 21,133 subjects. Results: We identified 1,860 items. After qualitative and quantitative evaluation, 124 newly developed PROMIS items composed the PROMIS item bank, which included revised Legacy items with good fit that met IRT model assumptions. Results showed that the clearest and best-understood items were simple, in the present tense, and straightforward. Basic tasks (like dressing) were more relevant and important versus complex ones (like dancing). Revised HAQ-DI and PF-10 items with five response options had higher item-information content than did comparable original Legacy items with fewer response options. IRT analyses showed that the Physical Function domain satisfied general criteria for unidimensionality with one-, two-, three-, and four-factor models having comparable model fits. Correlations between factors in the test data sets were > 0.90. Conclusions: Item improvement must underlie attempts to improve outcome assessment. The clear, personally important and relevant, ability-framed items in the PROMIS Physical Function item bank perform well in PRO assessment. They will benefit from further study and application in a wider variety of rheumatic diseases in diverse clinical groups, including those at the extremes of physical functioning, and in different administration modes.


  • Open Access

    Progress in Assessing Physical Function in Arthritis: PROMIS Short Forms and Computerized Adaptive Testing

    by James F. Fries, David Cella, Matthias Rose, Eswar Krishnan, Bonnie Bruce

    Objective.: Assessing self-reported physical function/disability with the Health Assessment Questionnaire Disability Index (HAQ) and other instruments has become central in arthritis research. Item response theory (IRT) and computerized adaptive testing (CAT) techniques can increase reliability and statistical power. IRT-based instruments can improve measurement precision substantially over a wider range of disease severity. These modern methods were applied and the magnitude of improvement was estimated.Methods.: A 199-item physical function/disability item bank was developed by distilling 1865 items to 124, including Legacy Health Assessment Questionnaire (HAQ) and Physical Function-10 items, and improving precision through qualitative and quantitative evaluation in over 21,000 subjects, which included about 1500 patients with rheumatoid arthritis and osteoarthritis. Four new instruments, (A) Patient-Reported Outcomes Measurement Information (PROMIS) HAQ, which evolved from the original (Legacy) HAQ; (B) “best” PROMIS 10; (C) 20-item static (short) forms; and (D) simulated PROMIS CAT, which sequentially selected the most informative item, were compared with the HAQ.Results.: Online and mailed administration modes yielded similar item and domain scores. The HAQ and PROMIS HAQ 20-item scales yielded greater information content versus other scales in patients with more severe disease. The “best” PROMIS 20-item scale outperformed the other 20-item static forms over a broad range of 4 standard deviations. The 10-item simulated PROMIS CAT outperformed all other forms.Conclusion.: Improved items and instruments yielded better information. The PROMIS HAQ is currently available and considered validated. The new PROMIS short forms, after validation, are likely to represent further improvement. CAT-based physical function/disability assessment offers superior performance over static forms of equal length.