IBIrit Bahar

Irit Bahar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Irit Bahar has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • Igor Kaiserman

    Care-Vision Laser Center, Tel Aviv, Israel

    18 shared publications
  • Allan Slomovic

    Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada

    6 shared publications
  • Penny McAllum

    Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Canada

    6 shared publications
  • David Rootman

    Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Canada

    5 shared publications
  • Dov Weinberger

    Department of Ophthalmology, Rabin Medical Center, Petah Tikva, Israel; Laboratory of Eye Research, Felsenstein Medical Research Center, Petah Tikva, Israel; and Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel

    5 shared publications
  • Allan R. Slomovic

    3 shared publications

Latest Publications

  • Remote Manipulation of Posterior Lamellar Corneal Grafts Using a Magnetic Field

    by Yoav Nahum, Tilda Barliya, Irit Bahar, Tami Livnat, Yael Msc Nisgav, Dov Weinberger

    Purpose: In posterior lamellar keratoplasty procedures such as Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty, the lamellar graft is manipulated directly or by injecting an air bubble. This preliminary study sought to evaluate the feasibility of guiding lamellar corneal grafts by generating a magnetic field. Methods: Rabbit and porcine Descemet stripping endothelial keratoplasty and Descemet membrane endothelial keratoplasty grafts were manually produced and immersed in a ferromagnetic solution containing nanomagnetic particles conjugated to streptavidin or in gadoteric acid. For the feasibility study, grafts were transferred to an artificial anterior chamber or plastic test tube and a magnetic field was generated with a handheld NdFeB disc magnet. The presence and the sustainability of graft motion were documented under various conditions. For the semiquantitative study, whole or partial grafts were transferred to a plastic test tube after immersion, and the amount of tissue retraction induced by the remote magnet was graded. Results: The grafts were successfully manipulated in all directions by the magnet, from a distance of up to 7 mm. They remained ferromagnetic more than 24 hours after immersion in the ferromagnetic solutions. The degree of retraction was affected by graft size, immersion time, time from immersion, and immersion solution. Conclusions: Posterior lamellar corneal grafts may be made ferromagnetic and remotely manipulated by creation of a magnetic field. The ferromagnetic properties are adjustable. This technique holds promise in attaching and repositioning grafts during keratoplasty. Further research is needed to assess the possible effects of ferromagnetic solutions on corneal endothelial cells and on lamellar graft clarity.

  • Changes in Corneal Curvatures and Anterior Segment Parameters after Descemet Stripping Automated Endothelial Keratoplasty

    by Irit Bahar, Igor Kaiserman, Eitan Livny, Allan Slomovic

    Purpose: To evaluate the influence of Descemet stripping automated endothelial keratoplsty (DSAEK) on corneal curvature and the anterior segment parameters obtained with the Pentacam rotating Scheimpflug camera. Methods: A total of 9 eyes of 9 consecutive patients (3 men, 6 women) were evaluated preoperatively, at 1 and 3 months postoperatively with the Pentacam. We compared preoperative and 1- and 3-month postoperative measurements of anterior and posterior corneal curvature, anterior and posterior corneal astigmatism, anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) width, central corneal thickness (CCT), and the corneal volume (CV). Results: Preoperative CCT decreased from 687 ± 85 microns to 631 ± 68 microns at 3 months after surgery (p = 0.07). Anterior mean K reading of the cornea flattened from 43.3 ± 1.65 diopter before surgery to 42.7 ± 1.5 diopter at 3 months (p = 0.03). Anterior corneal astigmatism did not change significantly. Posterior mean K reading of the cornea steepened significantly from -5.6 ± 0.6 diopter preoperatively to -7.2 ± 0.4 diopter at 3 months (p = 0.007). Posterior corneal astigmatism increased accordingly from 0.52 ± 0.17 diopter before surgery to 0.95 ± 0.57 diopter at 3 months (p = 0.07). CV increased significantly from 65.8 ± 5.6 µl before surgery to 85.2 ± 4.2 µl at 3 months (p = 0.007). ACA, ACD, and ACV did not change significantly following DSAEK surgery. The average postoperative spherical equivalent changed from 0.5 ± 2.5 D before surgery to 1.41 ± 0.59 D three months after surgery (p = 0.05). Conclusions: DSAEK significantly increased posterior corneal k-reading, posterior corneal astigmatism, and corneal volume, resulting in a mild hyperopic shift. This observation should be taken into consideration when performing a triple procedure.


  • Reply

    by Irit Bahar, Igor Kaiserman, Allan R. Slomovic

  • Retrospective Contralateral Study Comparing Descemet Stripping Automated Endothelial Keratoplasty With Penetrating Keratoplasty

    by Irit Bahar, Igor Kaiserman, Eliya Levinger, Wiwan Sansanayudh, Allan R Slomovic, David S Rootman

    To compare the visual outcomes and complications rate after penetrating keratoplasty (PKP) and Descemet stripping automated endothelial keratoplasty (DSAEK), in the fellow eye of the same subjects, and to evaluate the patient's perspective on these operations. A retrospective cohort study was undertaken in the Cornea Clinic at the Toronto Western Hospital. We reviewed the records of 12 patients (24 eyes) who underwent PKP in one eye and DSAEK surgery in their fellow eye. Patient's satisfaction for both procedures was evaluated using a subjective questionnaire. These techniques were compared for intraoperative and postoperative complications and visual and refractive outcomes including contrast acuity, contrast threshold, and high-order ocular aberrations (HOA). All the patients in this study preferred the DSAEK operation. They reported faster recovery time [1.5 week in the DSAEK vs 5.3 weeks in the PKP operation (P = 0.01)], significantly less pain, and better visual outcomes with the DSAEK operation. Uncorrected visual acuity and best-corrected visual acuity were significantly better in the DSAEK operated eyes. The DSAEK surgery was associated with significantly less astigmatism (P = 0.0003) and ametropia. Contrast acuity was significantly better in the eye that underwent DSAEK procedure (P < 0.05), whereas contrast threshold was better in the PKP eye. The PKP operated eyes demonstrated increased level of HOA. Patients preferred the DSAEK operation compared with PKP. Better uncorrected visual acuity, best-corrected visual acuity, and contrast acuity together with avoidance of surgery-induced astigmatism and HOA are the main benefits of the DSAEK technique.


  • The Effect of Mitomycin C on Corneal Endothelium in Pterygium Surgery

    by Irit Bahar, Igor Kaiserman, Alex P. Lange, Alana Slomovic, Eliya Levinger, Wiwan Sansanayudh, Allan R. Slomovic


  • Temporal and Seasonal Trends in Acanthamoeba Keratitis

    by Penny MBChB McAllum, Irit Bahar, Igor Md Kaiserman, Sathish Md Srinivasan, Allan Ma Slomovic, David Md Rootman

    Purpose: The purpose of this study was to assess the incidence and risk factors of Acanthamoeba keratitis (AK) over an 8-year period in a Canadian tertiary care setting. Methods: We retrospectively reviewed the medical records of 41 patients (42 eyes), who were diagnosed as having AK between January 1999 and December 2006 in the cornea clinic at the Toronto Western Hospital. The incidence and risk factors of AK were evaluated. Results: The number of cases per year increased from between 0 and 4 in the first 5 years to 9, 14, and 8 in the last 3 years. The annual increasing trend was statistically significant (P = 0.04). The month of onset of disease symptoms showed a trend toward onset in summer and fall and was statistically significant for the difference between January and August (P = 0.0094). The season of onset of disease symptoms showed a trend toward summer onset, and the difference between winter and summer was statistically significant (P = 0.02). 92.9% of cases occurred in contact lens wearers, particularly in soft contact lens wearers (82.1%). Conclusions: The incidence of AK in Canada may be increasing since 2004. There is a seasonal trend toward disease onset in the warmer months.


  • Comparison of Three Different Techniques of Corneal Transplantation for Keratoconus

    by Irit Bahar, Igor Kaiserman, Sathish Srinivasan, Jin Ya-Ping, Allan R. Slomovic, David S. Rootman


  • Posterior lamellar keratoplasty—comparison of deep lamellar endothelial keratoplasty and Descemet stripping automated endothelial keratoplasty in the same patients: a patient’s perspective

    by I Bahar, W Sansanayudh, E Levinger, I Kaiserman, S Srinivasan, D Rootman

    Aim: To evaluate patients’ perspectives on endothelial keratoplasty and to compare the outcomes of deep lamellar endothelial keratoplasty (DLEK) and Descemet stripping automated endothelial keratoplasty (DSAEK), performed in the same patients. Methods: A fellow eye, comparative retrospective case series. The records of 14 patients (28 eyes) who underwent DLEK in one eye and DSAEK surgery in their fellow eye between 2003 and 2007 were reviewed. Two patients were excluded from the study. Both these techniques were compared for intra- and postoperative complications, visual and refractive outcomes including higher-order ocular aberrations (HOA). Patient satisfaction for both procedures was prospectively evaluated using a subjective questionnaire. Results: Nine (75%) of the 12 patients perceived better vision in the DSAEK operated eye. Eight (66.6%) of the patients reported faster recovery following DSAEK. Ten (83%) of them preferred the outcomes of the DSAEK surgery. The intra- and postoperative complications were comparable between both procedures. There was no significant difference in visual outcomes between the procedures. However, the DLEK procedure was associated with a significantly higher degree (pConclusions: We conclude that most patients prefer the DSAEK operation, although there are no differences in visual outcomes between DLEK and DSAEK. Avoidance of surgery-induced hyperopia and HOA is the main benefit of the DSAEK technique.


  • Femtosecond laser versus manual dissection for top hat penetrating keratoplasty

    by I Bahar, I Kaiserman, A P Lange, E Levinger, W Sansanayudh, N Singal, A R Slomovic, D S Rootman

    Aim: To compare the outcomes of IntraLase-enabled top hat penetrating keratoplasty (IEK) versus retrospective results of manual top hat penetrating keratoplasty (TH-PKP) and conventional PKP. Patients/methods: This non-randomised prospective study included 94 eyes: 23 eyes underwent IEK, 36 TH-PKP and 35 conventional PKP. Preoperative and postoperative manifest refraction, uncorrected and best-spectacle corrected visual acuity (BSCVA), high-order ocular aberrations (HOA), endothelial cell counts and complications were analysed. Results: At 12 months of follow-up, the mean log MAR BSCVA was 0.32 (SD 0.31) in the IEK group, 0.53 (0.36) in the TH PKP group (p = 0.03) and 0.39 (0.30) in the conventional PKP group (p = 0.4). The mean spherical equivalent was similar between the groups and was less than −2.2 dioptres. The mean cylinder was similar in the IEK and conventional PKP group (3.6 (1.9) dioptres and 4.1 (1.8) dioptres, respectively), and was significantly lower than the TH-PKP group (5.1 (3.2) dioptres, p = 0.04). The complications rate and high-order ocular aberrations were similar between the three groups studied. The mean endothelial cell loss was significantly lower at 12 months of follow-up in the IEK and the TH-PKP groups versus conventional PKP (32.4% and 22.3% vs 40.8%, respectively) (p = 0.05). The mean time to suture removal was 4.1 (1.2) months in the IEK group and 3.9 (1.5) months in the TH-PKP group versus 9.7 (1.1) months in the conventional PKP group (pConclusions: IEK is a safe and stable procedure. It results in higher endothelial counts and faster suture removal in comparison with the conventional PKP, and has less astigmatism and better BSCVA in comparison with the manual TH-PKP.


  • Comparison of Posterior Lamellar Keratoplasty Techniques to Penetrating Keratoplasty

    by Irit Bahar, Igor Kaiserman, Penny McAllum, Allan Slomovic, David Rootman