Ashish K. Ahuja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ashish K. Ahuja has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- James David Weiland
University of Michigan, Ann Arbor, USA
2 shared publications - Mark. S. Humayun
Roski Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA 90089, USA
2 shared publications - Matthew R. Behrend
Department of Electrical Engineering, University of Southern California, Los Angeles, CA, USA
2 shared publications A. Caspi
Second Sight Medical Products, Sylmar, California, USA
1 shared publicationArgus II Study Group
1 shared publication- Arturo Santos
Tecnologico de Monterrey, Escuela de Medicina y Ciencias de la Salud, Monterrey 64849, Nuevo Leon, Mexico
1 shared publication
Latest Publications
- Open Access
- 29 September 2010
- Published by BMJ in British Journal of Ophthalmology
- Vol. 95 (4) , 539-543
Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task
Background/aims To determine to what extent subjects implanted with the Argus II retinal prosthesis can improve performance compared with residual native vision in a spatial-motor task. Methods High-contrast square stimuli (5.85 cm sides) were displayed in random locations on a 19″ (48.3 cm) touch screen monitor located 12″ (30.5 cm) in front of the subject. Subjects were instructed to locate and touch the square centre with the system on and then off (40 trials each). The coordinates of the square centre and location touched were recorded. Results Ninety-six percent (26/27) of subjects showed a significant improvement in accuracy and 93% (25/27) show a significant improvement in repeatability with the system on compared with off (p<0.05, Student t test). A group of five subjects that had both accuracy and repeatability values <250 pixels (7.4 cm) with the system off (ie, using only their residual vision) was significantly more accurate and repeatable than the remainder of the cohort (p<0.01). Of this group, four subjects showed a significant improvement in both accuracy and repeatability with the system on. Conclusion In a study on the largest cohort of visual prosthesis recipients to date, we found that artificial vision augments information from existing vision in a spatial-motor task. Clinical trials registry no NCT00407602.
- 29 September 2010
- Published by BMJ in British Journal of Ophthalmology
- Vol. 95 (4) , 539-543
Open AccessBlind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task
Background/aims To determine to what extent subjects implanted with the Argus II retinal prosthesis can improve performance compared with residual native vision in a spatial-motor task. Methods High-contrast square stimuli (5.85 cm sides) were displayed in random locations on a 19″ (48.3 cm) touch screen monitor located 12″ (30.5 cm) in front of the subject. Subjects were instructed to locate and touch the square centre with the system on and then off (40 trials each). The coordinates of the square centre and location touched were recorded. Results Ninety-six percent (26/27) of subjects showed a significant improvement in accuracy and 93% (25/27) show a significant improvement in repeatability with the system on compared with off (p<0.05, Student t test). A group of five subjects that had both accuracy and repeatability values <250 pixels (7.4 cm) with the system off (ie, using only their residual vision) was significantly more accurate and repeatable than the remainder of the cohort (p<0.01). Of this group, four subjects showed a significant improvement in both accuracy and repeatability with the system on. Conclusion In a study on the largest cohort of visual prosthesis recipients to date, we found that artificial vision augments information from existing vision in a spatial-motor task. Clinical trials registry no NCT00407602.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 4566-4568
Preliminary 6 month results from the argustm ii epiretinal prosthesis feasibility study
The Argustrade II 60 channel epiretinal prosthesis has been developed in order to provide partial restoration of vision to subjects blinded from outer retinal degenerative disease. To date the device has been implanted in 21 subjects as part of a feasibility study. In 6 month post-implantation door finding and line tracking orientation and mobility testing, subjects have shown improvements of 86% and 73%, respectively, for system on vs. system off. In high-contrast square localization tests using a touch screen monitor 87% of tested subjects performed significantly better with the system on compared with off. These preliminary results show that the Argus II system provides some functional vision to blind subjects.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2009 (1094687X) , 4566-4568
Preliminary 6 month results from the argustm ii epiretinal prosthesis feasibility study
The Argustrade II 60 channel epiretinal prosthesis has been developed in order to provide partial restoration of vision to subjects blinded from outer retinal degenerative disease. To date the device has been implanted in 21 subjects as part of a feasibility study. In 6 month post-implantation door finding and line tracking orientation and mobility testing, subjects have shown improvements of 86% and 73%, respectively, for system on vs. system off. In high-contrast square localization tests using a touch screen monitor 87% of tested subjects performed significantly better with the system on compared with off. These preliminary results show that the Argus II system provides some functional vision to blind subjects.
- 16 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (6) , 1744-1753
AnIn VitroModel of a Retinal Prosthesis
Epiretinal prostheses are being developed to bypass a degenerated photoreceptor layer and excite surviving ganglion and inner retinal cells. We used custom microfabricated multielectrode arrays with 200-mum-diameter stimulating electrodes and 10-mum-diameter recording electrodes to stimulate and record neural responses in isolated tiger salamander retina. Pharmacological agents were used to isolate direct excitation of ganglion cells from excitation of other inner retinal cells. Strength-duration data suggest that, if amplitude will be used for the coding of brightness or gray level in retinal prostheses, shorter pulses (200 mus) will allow for a smaller region in the area of the electrode to be excited over a larger dynamic range compared with longer pulses (1 ms). Both electrophysiological results and electrostatic finite-element modeling show that electrode-electrode interactions can lead to increased thresholds for sites half way between simultaneously stimulated electrodes (29.4 plusmn 6.6 nC) compared with monopolar stimulation (13.3 plusmn 1.7 nC, < 0.02). Presynaptic stimulation of the same ganglion cell with both 200- and 10- m-diameter electrodes yielded threshold charge densities of 12 plusmn 6 and 7.66 plusmn 1.30 nC/cm 2 , respectively, while the required charge was 12.5 plusmn 6.2 and 19 plusmn 3.3 nC.
- 16 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (6) , 1744-1753
AnIn VitroModel of a Retinal Prosthesis
Epiretinal prostheses are being developed to bypass a degenerated photoreceptor layer and excite surviving ganglion and inner retinal cells. We used custom microfabricated multielectrode arrays with 200-mum-diameter stimulating electrodes and 10-mum-diameter recording electrodes to stimulate and record neural responses in isolated tiger salamander retina. Pharmacological agents were used to isolate direct excitation of ganglion cells from excitation of other inner retinal cells. Strength-duration data suggest that, if amplitude will be used for the coding of brightness or gray level in retinal prostheses, shorter pulses (200 mus) will allow for a smaller region in the area of the electrode to be excited over a larger dynamic range compared with longer pulses (1 ms). Both electrophysiological results and electrostatic finite-element modeling show that electrode-electrode interactions can lead to increased thresholds for sites half way between simultaneously stimulated electrodes (29.4 plusmn 6.6 nC) compared with monopolar stimulation (13.3 plusmn 1.7 nC, < 0.02). Presynaptic stimulation of the same ganglion cell with both 200- and 10- m-diameter electrodes yielded threshold charge densities of 12 plusmn 6 and 7.66 plusmn 1.30 nC/cm 2 , respectively, while the required charge was 12.5 plusmn 6.2 and 19 plusmn 3.3 nC.
- 15 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (3) , 1056-1062
Dynamic Current Density of the Disk Electrode Double-Layer
With applied potential, the current distribution at the surface of a disk electrode is spatially nonuniform and time dependent. This distribution is important to control in applications that desire a uniform current density profile or minimal corrosion. We examine the current density profile of a capacitive disk electrode subjected to a voltage-step using finite element analysis software to solve the system of partial differential equations. In detailed analyses we show quantitatively that the current density shifts from peripheral enhancement to near-uniformity following 1/2 of the lumped element time constant. As charging continues, the current density is slightly enhanced in the central region. We present curves for the evolution of local ldquotime constantsrdquo as time progresses and calculate their effective values. The model is intended to be the basis of future work to control the corrosion profile of biologically implantable electrodes of arbitrary shape. Data suggest a means to control corrosion by retarding the edges of a stimulus pulse. Additionally, smaller electrodes may be more effective in fully utilizing surface area for charge transfer due to their shorter time constants.
- 15 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (3) , 1056-1062
Dynamic Current Density of the Disk Electrode Double-Layer
With applied potential, the current distribution at the surface of a disk electrode is spatially nonuniform and time dependent. This distribution is important to control in applications that desire a uniform current density profile or minimal corrosion. We examine the current density profile of a capacitive disk electrode subjected to a voltage-step using finite element analysis software to solve the system of partial differential equations. In detailed analyses we show quantitatively that the current density shifts from peripheral enhancement to near-uniformity following 1/2 of the lumped element time constant. As charging continues, the current density is slightly enhanced in the central region. We present curves for the evolution of local ldquotime constantsrdquo as time progresses and calculate their effective values. The model is intended to be the basis of future work to control the corrosion profile of biologically implantable electrodes of arbitrary shape. Data suggest a means to control corrosion by retarding the edges of a stimulus pulse. Additionally, smaller electrodes may be more effective in fully utilizing surface area for charge transfer due to their shorter time constants.