Liza Keating
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liza Keating has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Donald M. Mackay
University of Oxford, UK
1 shared publication F P Morris
1 shared publication- Helen Carter
Cairns Library, John Radcliffe Hospital, Oxford
1 shared publication J Kendall
1 shared publication- Jonathan Benger
University of the West of England, Bristol, UK
1 shared publication Melanie Darwent
Emergency Department, John Radcliffe Hospital
1 shared publication
Latest Publications
- Open Access
- 1 October 2006
- Published by BMJ in Emergency Medicine Journal
- Vol. 23 (10) , 764-768
The PRIMA Study: presentation ischaemia-modified albumin in the emergency department
To investigate the diagnostic accuracy of presentation ischaemia-modified albumin (IMA), in addition to cardiac troponin I (TnI), as a strategy to rapidly ascribe low risk to patients with chest pain attending an emergency department, and to determine whether IMA has the potential to reduce transit time in emergency departments. A prospective observational study was carried out in two emergency departments (belonging to the John Radcliffe Hospital, Oxford, UK; and the Frenchay Hospital, Bristol, UK) of similar size. Consecutive adult patients presenting with features of possible ischaemic cardiac chest pain and a normal electrocardiogram were eligible. The index test (measurement of IMA and TnI at presentation) and reference standard (delayed TnI measurement, taken at least 8 h after pain onset) were applied to all recruited patients. All clinicians were blinded to the results of the index test. Assays were carried out in a single laboratory using standard techniques. 399 patients were recruited; 277 patients had a result for both the index test and reference standard. The sensitivity was 97.6% (95% confidence interval (CI) 87.4 to 99.9), negative predictive value 97% (95% CI 84.2 to 99.9) and specificity 13.6% (95% CI 9.5 to 18.7). Sensitivity analysis showed similar findings in three alternative scenarios. Receiver operating characteristic analysis indicated that a different "cut-off" value for IMA would not improve the properties of the test. The median potential time saved (n = 268) was 6 h and 10 min. The diagnostic accuracy of presentation IMA in this study does not support its use as an effective risk stratification tool for patients with chest pain in the emergency department. The sensitivity is insufficiently high, with a small number of false negatives undermining the safety of the test. Frequent false positives produce a low specificity that limits the practical value of the test.
- 1 October 2006
- Published by BMJ in Emergency Medicine Journal
- Vol. 23 (10) , 764-768
Open AccessThe PRIMA Study: presentation ischaemia-modified albumin in the emergency department
To investigate the diagnostic accuracy of presentation ischaemia-modified albumin (IMA), in addition to cardiac troponin I (TnI), as a strategy to rapidly ascribe low risk to patients with chest pain attending an emergency department, and to determine whether IMA has the potential to reduce transit time in emergency departments. A prospective observational study was carried out in two emergency departments (belonging to the John Radcliffe Hospital, Oxford, UK; and the Frenchay Hospital, Bristol, UK) of similar size. Consecutive adult patients presenting with features of possible ischaemic cardiac chest pain and a normal electrocardiogram were eligible. The index test (measurement of IMA and TnI at presentation) and reference standard (delayed TnI measurement, taken at least 8 h after pain onset) were applied to all recruited patients. All clinicians were blinded to the results of the index test. Assays were carried out in a single laboratory using standard techniques. 399 patients were recruited; 277 patients had a result for both the index test and reference standard. The sensitivity was 97.6% (95% confidence interval (CI) 87.4 to 99.9), negative predictive value 97% (95% CI 84.2 to 99.9) and specificity 13.6% (95% CI 9.5 to 18.7). Sensitivity analysis showed similar findings in three alternative scenarios. Receiver operating characteristic analysis indicated that a different "cut-off" value for IMA would not improve the properties of the test. The median potential time saved (n = 268) was 6 h and 10 min. The diagnostic accuracy of presentation IMA in this study does not support its use as an effective risk stratification tool for patients with chest pain in the emergency department. The sensitivity is insufficiently high, with a small number of false negatives undermining the safety of the test. Frequent false positives produce a low specificity that limits the practical value of the test.
- 28 May 2004
- Published by Wiley in Health Information and Libraries Journal
- Vol. 21 (s1) , 46-51
Partnership working in the production of clinical guidelines
This article describes a working partnership between the Cairns Clinical Librarian Service, Health Care Libraries, University of Oxford and the Emergency Department (ED) at the John Radcliffe Hospital, Oxford. This collaboration resulted in the establishment of a guideline development group in June 2002. The aim of the group is to produce a set of easily accessible, user-orientated, evidence-based guidelines for the use of clinicians in the Emergency Department, within a realistic timescale. The Cairns Clinical Librarian Project was built on previous models of clinical librarianship and incorporated an evaluation of previous programmes. The objective was to provide information to clinicians at the time and point of need. Consultation with the ED from the outset determined the approach adopted by the Cairns team. Clinical guidelines have been shown to improve clinical practice. Pending the introduction of nationally available protocols, we have begun to establish a collection of evidence-based guidelines using web-based architecture in conjunction with the Oxford Radcliffe Hospitals NHS Trust's IT department. A piece of diagnostic analysis was undertaken to ensure a coherent strategy was developed for the guideline project. An 'intermediate approach' was adopted, where existing valid guidelines were modified to fit local circumstances. We strove to be transparent at all times about all aspects of the guideline development process. Formative evaluation has shown how the application of evidence-based health care needs adequate resources and requires people with appropriate knowledge and skills. This article charts the progress of the project and highlights how the partnership between the clinical team and the Clinical Librarian has been deemed to be essential to the success of the project.
- 28 May 2004
- Published by Wiley in Health Information and Libraries Journal
- Vol. 21 (s1) , 46-51
Partnership working in the production of clinical guidelines
This article describes a working partnership between the Cairns Clinical Librarian Service, Health Care Libraries, University of Oxford and the Emergency Department (ED) at the John Radcliffe Hospital, Oxford. This collaboration resulted in the establishment of a guideline development group in June 2002. The aim of the group is to produce a set of easily accessible, user-orientated, evidence-based guidelines for the use of clinicians in the Emergency Department, within a realistic timescale. The Cairns Clinical Librarian Project was built on previous models of clinical librarianship and incorporated an evaluation of previous programmes. The objective was to provide information to clinicians at the time and point of need. Consultation with the ED from the outset determined the approach adopted by the Cairns team. Clinical guidelines have been shown to improve clinical practice. Pending the introduction of nationally available protocols, we have begun to establish a collection of evidence-based guidelines using web-based architecture in conjunction with the Oxford Radcliffe Hospitals NHS Trust's IT department. A piece of diagnostic analysis was undertaken to ensure a coherent strategy was developed for the guideline project. An 'intermediate approach' was adopted, where existing valid guidelines were modified to fit local circumstances. We strove to be transparent at all times about all aspects of the guideline development process. Formative evaluation has shown how the application of evidence-based health care needs adequate resources and requires people with appropriate knowledge and skills. This article charts the progress of the project and highlights how the partnership between the clinical team and the Clinical Librarian has been deemed to be essential to the success of the project.
- 3 September 2003
- Published by BMJ in Emergency Medicine Journal
- Vol. 20 (5) , 491-493
Electrocardiographic features of Wolff-Parkinson-White syndrome
Wolff-Parkinson-White syndrome is not uncommon in the emergency department. Its early recognition and initial treatment allows rapid restoration to sinus rhythm. Prompt referral to cardiology is essential for risk stratification through electrophysiological studies.
- 3 September 2003
- Published by BMJ in Emergency Medicine Journal
- Vol. 20 (5) , 491-493
Electrocardiographic features of Wolff-Parkinson-White syndrome
Wolff-Parkinson-White syndrome is not uncommon in the emergency department. Its early recognition and initial treatment allows rapid restoration to sinus rhythm. Prompt referral to cardiology is essential for risk stratification through electrophysiological studies.