SAShahid Aziz

Shahid Aziz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shahid Aziz has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Acute Aortic Regurgitation Due to Necrotizing Granulomatous Inflammation of the Aortic Valve in a Patient With Rheumatoid Arthritis

    by Shahid Aziz, Mohammed Sohail, Gavin Murphy, William C. Roberts, Bruce F. Waller, John B. Carter, Hugh J. Williams, Kyuhyun Wang, Jesse E. Edwards, Ahmed-Amir Bouchachi, et al.


    • 1 July 2008
      • Vol. 20  (7) , 342-6

    Postdilatation following coronary stent deployment: lesion and procedural characteristics associated with an increase in stent dimensions.

    by Shahid Aziz, John L Morris, Raphael A Perry, Rodney H Stables

    Adjunctive balloon postdilatation following stent deployment is often used to optimize stent expansion. However, the benefit of this strategy with modern stent delivery systems is not known. We investigated angiographic and procedural factors associated with a favorable response to postdilatation after coronary stent deployment. We performed a prospective study recruiting 385 patients (490 lesions) who underwent stent deployment. Quantitative coronary angiography was used to measure the minimal lumen diameter (MLD) within the stent before and after postdilatation. Optimal stent deployment was defined as a stent MLD greater than or equal to 90% of the reference vessel diameter. Postdilatation was performed in 41.2% (202/490) of cases, with an increase in stent MLD from mean (SD) 2.50 (0.40) to 2.70 (0.38) mm, p < 0.0001. Optimal stent deployment increased from 35.6% (72/202) to 56.5% (115/202). The percentage increase in stent MLD with postdilatation was greatest in cases with a residual stenosis of > 20% after coronary stenting or a stent deployment pressure < or = 14 atm. Vessel size and predilatation had no impact on the response to postdilatation. In those cases where postdilatation was not performed, optimal stent deployment was achieved in 64.9% (187/288) of cases. A significant proportion of patients did not achieve optimal stent deployment with modern stent delivery systems. The increase in stent MLD with postdilatation was greater in cases with lower stent deployment pressures and more significant residual stenoses.

    • 1 April 2007
      • Vol. 19  (4) , E96-8

    Late stent thrombosis associated with coronary aneurysm formation after sirolimus-eluting stent implantation.

    by Shahid Aziz, John L Morris, Raphael A Perry

    Stent thrombosis is a rare but potentially fatal complication of coronary stent implantation. Its occurrence late after drug-eluting stent (DES) deployment has led to concerns regarding their long-term safety. We report a case of late stent thrombosis 26 months after sirolimus-eluting stent (SES) (Cypher, Cordis Corp., Miami, Florida) implantation. This was associated with marked positive vessel remodeling and coronary aneurysm formation involving the stented segment of the coronary artery. The patient was on dual antiplatelet therapy at the time.


  • Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size

    by S. Aziz, J. L Morris, R. A Perry, R. H Stables

    There is a strong inverse relationship between final vessel diameter and subsequent risk of treatment failure after coronary stent deployment. The aim of this study was to investigate the magnitude by which stent delivery balloon underexpansion and stent elastic recoil contributed to suboptimal final vessel geometry. A prospective angiographic study recruiting 499 lesions (385 patients) undergoing coronary stent implantation was performed. Quantitative coronary angiography (QCA) was used to measure the minimal lumen diameters of the delivery balloon during stent deployment (MLD1) and of the stented segment following balloon deflation (MLD2). The expected balloon diameter for the deployment pressure was determined from the manufacturer's reference chart. Delivery balloon deficit was measured by subtracting the MLD1 from the expected balloon size and stent recoil was calculated by subtracting MLD2 from MLD1. Delivery balloon deficit and stent recoil were examined as a function of reference vessel diameter (RVD) and balloon-vessel (BV) ratio. The final stent MLD was a mean 27.2% (SD = 7.2) less than the predicted diameter. The mean delivery balloon deficit was 0.65 mm (SD = 0.27) and the mean stent recoil was 0.28 mm (SD = 0.17). Percentage delivery balloon deficit and stent recoil were independent of RVD. Delivery balloon deficit increased with higher BV ratios. Stent recoil was independent of BV ratio and the use of predilatation. Failure to achieve predicted final stent diameter is a real problem with contribution from delivery balloon underexpansion and stent recoil. On average the final stent MLD is only 73% of the expected diameter, irrespective of vessel size.


  • Open Access

    Coronary steal induced by angiogenesis following bypass surgery

    by S Aziz

    Selective injection of the left internal mammary artery (LIMA) (arrowhead) was performed by a catheter introduced via the left radial artery. This showed that there were extensive bridging collaterals arising from the LIMA with collateral filling of the left pulmonary artery (arrow). Blood supply to the native left anterior descending artery via the LIMA was presumably compromised by a steal phenomenon into the low pressure pulmonary circulation. This case represents a vivid demonstration of new vessel angiogenesis, from an artery rendered free of side branches at surgical mobilisation, and suggests great potential for this form of treatment in ischaemic heart and peripheral vascular disease. The stimulus to angiogenesis was presumably surgical inflammation of lung and vascular tissue, laid in apposition. It may be best to avoid simultaneous lung resection at the time of LIMA harvest.


    • 1 November 2004
      • Vol. 16  (11) , 632-4

    Bacteremia following complex percutaneous coronary intervention.

    by David R Ramsdale, Shahid Aziz, Nick Newall, Nick Palmer, Mark Jackson

    Complex percutaneous coronary intervention (PCI) often requires introduction of numerous devices into and out of the arterial circulation and this may result in an increased risk of bacteraemia or even septicaemia. This study was undertaken to detect the frequency of bacteraemia that may be associated with such procedures. 147 patients undergoing complex PCI had blood culture tests immediately after and 12 hours after the procedure. Of 147 patients, 26 (17.7%) had detectable bacteraemia immediately after PCI. Coagulase-negative staphylococcus was isolated most commonly. An additional 12% of patients yielded positive blood cultures in the next 12 hours with femoral sheaths still in-situ. There were no associated clinical sequelae. Uncomplicated bacteraemia is not uncommon as a result of complex PCI procedures. Although there are usually no clinical sequelae, these findings are important for those patients who are considered to be at moderate or high risk of infective endocarditis who require an invasive procedure such as PCI. This paper emphasizes the need for maximum sterility during PCI procedures if infective complications and stent infection are to be avoided.


    • 1 September 2004
      • Vol. 16  (9) , 482-4

    Intracoronary myocardial contrast echocardiography in a patient with drug refractory hypertrophic obstructive cardiomyopathy revealing extensive myocardium at risk for infarction with alcohol septal ablation.

    by Daniel Monakier, Eric Horlick, John Ross, Anna Woo, Harry Rakowski, Leonard Schwartz, Michael P Riley, Joseph R Carver, Kul Aggarwal, Erskine A James, et al.


    • 1 November 2003
      • Vol. 15  (11) , 657-8

    Anomalous origin of left internal mammary artery.

    by Shahid Aziz, David R Ramsdale

    We present a case of a left internal mammary artery (LIMA) originating from the third part of the subclavian artery. Awareness of this possibility is particularly important when considering reintervention after coronary artery bypass surgery and the LIMA appears to be missing rather than obviously occluded.