KBKaren Blackhall

Karen Blackhall

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karen Blackhall has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ionisers for chronic asthma

    by Karen Blackhall, Sarah Appleton, Christopher J Cates

    Previous reports have shown that ion content in the air may have an effect on respiratory function. Results from studies which test the efficacy of air ionisers to reduce asthma symptoms are often inconclusive and their use as a treatment for asthma remains debatable. We conducted a systematic review of the available evidence to determine the effectiveness of positive and negative ion generators in people with asthma. We searched the Cochrane Airways Group Specialised Register, Cochrane Central Register of Controlled Trials (CENTRAL) as well as the alternative medicine database AMED. Searches were current as of June 2012. Randomised controlled trials (parallel or crossover design studies) comparing ionisers with dummy ionisers (being negative or positive ion emitters), in children or adults with chronic asthma. Two reviewers independently assessed titles and abstracts of studies and assessed trial quality. Study quality was determined using two methods:The Cochrane approach to allocation concealment and the five point Jadad scale. Six studies were selected for inclusion (106 participants). No results were combined as the studies were all of a crossover design. EFFECTS OF NEGATIVE ION GENERATORS (five studies) No study reported a significant difference in lung function between ionised and control air (morning Peak expiratory flow (PEF) - three studies; forced expiratory flow in one second (FEV1) - one study). There were no significant differences in symptoms or beta-2 agonist usage between ionised and control air in three studies. EFFECTS OF POSITIVE ION GENERATORS (one study) This study demonstrated that although positively ionised air was associated with a larger fall in FEV1 with exercise, this did not reach statistical significance. Baseline FEV1 was not demonstrated to be significantly different between treatment groups. Based on the evidence currently available from randomised controlled trials, a recommendation cannot be given for the use of room air ionisers to reduce symptoms in patients with chronic asthma. Ioniseurs contre l'asthme chronique Les précédents rapports ont montré que la teneur en ions de l'air pouvait avoir un effet sur la fonction respiratoire. Les résultats d'études qui testent l'efficacité des ioniseurs d'air pour réduire les symptômes de l'asthme sont souvent peu concluants et l'usage de ces ioniseurs comme traitement de l'asthme reste discutable. Nous avons réalisé une revue systématique des preuves disponibles pour déterminer l'efficacité des générateurs d'ions positifs et négatifs chez les personnes asthmatiques. Nous avons effectué des recherches dans le registre spécialisé du groupe Cochrane sur les voies respiratoires, le registre Cochrane des essais contrôlés (CENTRAL), ainsi que dans la base de données de médecine alternative AMED. Les études couraient jusqu’en juin 2012. Les essais contrôlés randomisés (études parallèles ou croisées) comparant les ioniseurs à des ioniseurs factices (émetteurs d'ions négatifs ou positifs) chez des enfants ou des adultes souffrant d'asthme chronique. Deux relecteurs ont évalué de façon indépendante les titres et les résumés des études et évalué la qualité des essais. La qualité des études a été déterminée au moyen de deux méthodes : l'approche Cochrane de l'assignation secrète et l'échelle de Jadad à cinq points. Six études ont été sélectionnées pour l'inclusion (106 participants). Aucun résultat n'a été combiné, car les études avaient toutes un plan croisé. EFFETS DES GÉNÉRATEURS D'IONS NÉGATIFS (cinq études) Aucune étude n'a indiqué de différence significative concernant la fonction pulmonaire entre l'air ionisé et l'air témoin (débit expiratoire de pointe (DEP) le matin - trois études ; volume expiratoire maximal en une seconde (VEMS) - une étude). Il n'a été observé aucune différence significative concernant les symptômes ou l'usage de bêta2-agonistes entre l'air ionisé et l'air témoin dans les trois études. EFFETS DES GÉNÉRATEURS D'IONS POSITIFS (une étude) Cette étude a démontré que bien que l'air ionisé par des ions positifs ait été associé à une baisse plus importante de la VEMS à l'effort, cette baisse n'a pas atteint une signification statistique. Il n'a pas été démontré que la VEMS de départ était significativement différente selon les groupes de traitement. D'après les preuves actuelles fournies par des essais contrôlés randomisés, il est impossible de recommander l'usage d'ioniseurs d'air ambiant pour réduire les symptômes chez les patients souffrant d'asthme chronique. Translated by: French Cochrane Centre Translation supported by: Ministère du Travail, de l'Emploi et de la Santé Français 慢性喘息のためのイオン発生器 過去の報告では空気中のイオン含有量が呼吸機能に影響する可能性があることが示された。喘息症状を低減するイオン発生器の有効性を検討する試験結果は時に結論が得られず、喘息治療のためのその使用には依然として異論が残る。 喘息患者に対する陽イオン及び陰イオン発生器の有効性を判断するために入手可能なエビデンスのシステマテックレビューを実施した。 Cochrane Airways Group Specialised Register、Cochrane Central Register of Controlled Trials(CENTRAL)及び代替医療データベースAMEDを検索した。最新の検索は、2012年6月に実施した。 小児又は成人慢性喘息患者において対象となるイオン発生器をダミーイオン発生器(陽イオン放出器又は陰イオン放出器)と比較するランダム化比較試験(並行群間研究又はクロスオーバーデザイン研究)。...


  • Open Access

    Anti-fibrinolytic agents in post partum haemorrhage: a systematic review

    by Pili Ferrer, Ian Roberts, Emma Sydenham, Karen Blackhall, Haleema Shakur

    Background: Post partum haemorrhage is a leading cause of maternal death worldwide. It also contributes to maternal morbidity as women may require a hysterectomy to control bleeding, or may require a blood transfusion, which can transmit viral infections. Anti-fibrinolytic agents have been proposed as a treatment for post partum haemorrhage. We conducted a systematic review to assess the effectiveness and safety of anti-fibrinolytic agents in post partum bleeding. Methods: All randomised controlled trials of anti-fibrinolytic agents given for bleeding during the postpartum period were included in this review. We searched Medline, PubMed, EMBASE, Cochrane Central Register of Controlled trials, Web of Science, metaRegister of controlled trials, LILACS, Reproductive Health Library, African healthline, POPLINE, MedCarib, CINAHL, Clinicaltrials.gov and the reference lists of eligible trials. Two authors extracted data. Methodological quality was assessed by evaluating allocation concealment. The primary outcome was maternal mortality. Secondary outcomes were blood loss, blood transfusion, hysterectomy, mean haemoglobin concentration, thrombo-embolic events and other adverse effects. Results: We identified three randomised controlled trials involving 461 participants. The trials compared tranexamic acid with no treatment and reported blood loss after delivery. In all three trials, allocation concealment was either inadequate or unclear. The administration of tranexamic acid was associated with a reduction in blood loss of 92 millilitres (95%CI 76 to 109). The most frequently reported adverse effect of tranexamic acid was nausea, although the increase was easily compatible with the play of chance (RR 4.63, 95%CI 0.23 to 95.14). Conclusion: Tranexamic acid may reduce blood loss in post partum haemorrhage. However, the quality of the currently available evidence is poor. Adequately powered, high quality randomised controlled trials are needed.


  • Open Access

    Searching for studies for inclusion in Cochrane Systematic Reviews on injury prevention

    by K Blackhall, K Ker

    An adequate search is key to ensuring high quality of the resultant review. To achieve the aim of identifying all relevant evidence, sophisticated information searching techniques are required. It is, however, a challenge to devise a search strategy with the appropriate balance between sensitivity and specificity; a sensitive search is required in order to identify as much of the relevant evidence as possible, yet specificity is required to ensure that the review author is not forced to wade through extensive amounts of irrelevant information. Search methods for every review need careful consideration to ensure that eligible studies are not missed or rejected, which could compromise the review’s findings.


  • Open Access

    Finding studies for inclusion in systematic reviews of interventions for injury prevention – the importance of grey and unpublished literature

    by K Blackhall

    It is therefore considered essential that active and extensive searching for unpublished and grey literature is undertaken as part of the review process for all CIG reviews, although we feel this to be particularly important for reviews of injury prevention interventions.


  • Open Access

    Ionisers for chronic asthma

    by Karen Blackhall, Sarah Appleton, Christopher J Cates

    Previous reports have shown that ion content in the air may have an effect on respiratory function. Results from studies which test the efficacy of air ionisers to reduce asthma symptoms are often inconclusive and their use as a treatment for asthma remains debatable. We conducted a systematic review of the available evidence to determine the effectiveness of positive and negative ion generators in people with asthma. We searched the Cochrane Airways Group Asthma trials register (January 1966 to March 2003), Cochrane Central Register of Controlled Trials (Cochrane Library issue 2, 2003) as well as The Alternative Medicine Database AMED (1985 to March 2003). Randomised controlled trials (parallel or crossover design studies) comparing ionisers with dummy ionisers (being negative or positive ion emitters), in children or adults with chronic asthma. Two reviewers independently assessed titles and abstracts of studies and assessed trial quality. Study quality was determined using two methods:The Cochrane approach to allocation concealment and the five point Jadad scale. Six studies were selected for inclusion (106 participants). No results were combined as the studies were all of a crossover design. EFFECTS OF NEGATIVE ION GENERATORS (five studies)No study reported a significant difference in lung function between ionised and control air (morning Peak expiratory flow (PEF) - three studies; forced expiratory flow in one second (FEV1) - one study). There were no significant differences in symptoms or beta-2 agonist usage between ionised and control air in three studies. EFFECTS OF POSITIVE ION GENERATORS (one study)This study demonstrated that although positively ionised air was associated with a larger fall in FEV1 with exercise, this did not reach statistical significance. Baseline FEV1 was not demonstrated to be significantly different between treatment groups. Based on the evidence currently available from randomised controlled trials, a recommendation cannot be given for the use of room air ionisers to reduce symptoms in patients with chronic asthma.