Zsuzsanna Deák
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zsuzsanna Deák has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Maximilian F. Reiser
Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Clin Radiol, Campus City Ctr,Nussbaumstr 20, Munich, Germany
3 shared publicationsLucas L. Geyer
Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Clin Radiol, Campus City Ctr,Nussbaumstr 20, Munich, Germany
2 shared publicationsMarcus Treitl
2 shared publicationsStefan Wirth
Ludwig Maximilians Univ Munchen, Univ Hosp, Inst Clin Radiol, Campus City Ctr,Nussbaumstr 20, Munich, Germany
2 shared publications- Aina Krtakovska
Department of Radiology, Azienda Ospedaliero Universitaria Pisana, University of Pisa, Pisa, Italy
1 shared publication C. Degenhart
Klinikum der Ludwig-Maximilians-Universität München, Campus Innenstadt
1 shared publication
Latest Publications
- 1 January 2017
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 41 (2) , 254-262
Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm
The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. Thirty-six patients receiving chest CT according to 3 protocols (120 kVp/noise index [NI], 60; 100 kVp/NI, 65; 80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity; the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. Diagnostic images (lesion conspicuity, 95%–100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. Model-based algorithm allows for submillisievert chest CT in average patients; the use of 100 kVp is recommended.
- 1 January 2017
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 41 (2) , 254-262
Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm
The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. Thirty-six patients receiving chest CT according to 3 protocols (120 kVp/noise index [NI], 60; 100 kVp/NI, 65; 80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity; the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. Diagnostic images (lesion conspicuity, 95%–100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. Model-based algorithm allows for submillisievert chest CT in average patients; the use of 100 kVp is recommended.
- 1 May 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1061) , 20150996
Emergency radiology: straightening of the cervical spine in MDCT after trauma—a sign of injury or normal variant?
To evaluate whether straightening of the C-spine alignment after trauma can be considered a significant MDCT finding. 160 consecutive patients after C-spine trauma admitted to a level 1° trauma centre received MDCT according to CCR and NEXUS indication rules; subgroups with and without cervical collar immobilization (CCI +/-) were compared with a control group (n=20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2-7) and grouped the results for lordosis (< -13°), straight (-13° - +6°) and kyphosis (> +6°). In the two CCI-/CCI+ study groups the straight or kyphotic alignment significantly (p=0.001) predominated over lordosis. The number of patients with a straight C-spine alignment was higher in the CCI+ group (CCI+ 69% vs. CCI- 49%, p=0.05). A comparison of the CCI+ vs. the CCI- group revealed a slightly smaller number of kyphotic (10% vs. 18%, p=0.34) and lordotic (21% vs. 33%, p=0.33) alignments. Statistically, however, the differences were of no significance. The control group revealed no significant differences. Straightening of the cervical spine alone is not a definitive sign of injury but is a biomechanical variation due to CCI and neck positioning during MDCT or active patient control. Straightening of the C-spine alignment in MDCT alone is not a definitive sign of injury. Straightening of the C-spine alignment is related to neck positioning and active patient control. CCI has a straightening effect on the cervical alignment.
- 1 May 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1061) , 20150996
Emergency radiology: straightening of the cervical spine in MDCT after trauma—a sign of injury or normal variant?
To evaluate whether straightening of the C-spine alignment after trauma can be considered a significant MDCT finding. 160 consecutive patients after C-spine trauma admitted to a level 1° trauma centre received MDCT according to CCR and NEXUS indication rules; subgroups with and without cervical collar immobilization (CCI +/-) were compared with a control group (n=20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2-7) and grouped the results for lordosis (< -13°), straight (-13° - +6°) and kyphosis (> +6°). In the two CCI-/CCI+ study groups the straight or kyphotic alignment significantly (p=0.001) predominated over lordosis. The number of patients with a straight C-spine alignment was higher in the CCI+ group (CCI+ 69% vs. CCI- 49%, p=0.05). A comparison of the CCI+ vs. the CCI- group revealed a slightly smaller number of kyphotic (10% vs. 18%, p=0.34) and lordotic (21% vs. 33%, p=0.33) alignments. Statistically, however, the differences were of no significance. The control group revealed no significant differences. Straightening of the cervical spine alone is not a definitive sign of injury but is a biomechanical variation due to CCI and neck positioning during MDCT or active patient control. Straightening of the C-spine alignment in MDCT alone is not a definitive sign of injury. Straightening of the C-spine alignment is related to neck positioning and active patient control. CCI has a straightening effect on the cervical alignment.
- 1 January 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 266 (1) , 197-206
Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
To compare objective and subjective image quality parameters of three image reconstruction algorithms of different generations at routine multidetector computed tomographic (CT) examinations of the abdomen. This institutional review board-approved study included 22 consecutive patients (mean age, 56.1 years ± 15.8 [standard deviation]; mean weight, 79.1 kg ± 14.8) who underwent routine CT examinations of the abdomen. A low-contrast phantom was used for objective quality control. Raw data sets were reconstructed by using filtered back projection (FPB), adaptive statistical iterative reconstruction (ASIR), and a model-based iterative reconstruction (MBIR). Radiologists used a semiquantitative scale (-3 to +3) to rate subjective image quality and artifacts, comparing both FBP and MBIR images with ASIR images. The Wilcoxon test and the intraclass correlation coefficient were used to evaluate the data. Measurements of objective noise and CT numbers of soft tissue structures were compared with analysis of variance. The phantom study revealed an improved detectability of low-contrast targets for MBIR compared with ASIR or FBP. Subjective ratings showed higher image quality for MBIR, with better resolution (median value, 2; range, 1 to 3), lower noise (2; range, 1 to 3), and finer contours (2; range, 1 to 2) compared with ASIR (all P < .001). FBP performed inferiorly (0, range, -2 to 0]; -1 [range, -3 to 0]; 0 [range, -1 to 0], respectively; all, P < .001). Mean interobserver correlation was 0.9 for image perception and 0.7 for artifacts. Objective noise for FBP was 14%-68% higher and for MBIR was 18%-47% lower than that for ASIR (P < .001). The MBIR algorithm considerably improved objective and subjective image quality parameters of routine abdominal multidetector CT images compared with those of ASIR and FBP.
- 1 January 2013
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 266 (1) , 197-206
Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study
To compare objective and subjective image quality parameters of three image reconstruction algorithms of different generations at routine multidetector computed tomographic (CT) examinations of the abdomen. This institutional review board-approved study included 22 consecutive patients (mean age, 56.1 years ± 15.8 [standard deviation]; mean weight, 79.1 kg ± 14.8) who underwent routine CT examinations of the abdomen. A low-contrast phantom was used for objective quality control. Raw data sets were reconstructed by using filtered back projection (FPB), adaptive statistical iterative reconstruction (ASIR), and a model-based iterative reconstruction (MBIR). Radiologists used a semiquantitative scale (-3 to +3) to rate subjective image quality and artifacts, comparing both FBP and MBIR images with ASIR images. The Wilcoxon test and the intraclass correlation coefficient were used to evaluate the data. Measurements of objective noise and CT numbers of soft tissue structures were compared with analysis of variance. The phantom study revealed an improved detectability of low-contrast targets for MBIR compared with ASIR or FBP. Subjective ratings showed higher image quality for MBIR, with better resolution (median value, 2; range, 1 to 3), lower noise (2; range, 1 to 3), and finer contours (2; range, 1 to 2) compared with ASIR (all P < .001). FBP performed inferiorly (0, range, -2 to 0]; -1 [range, -3 to 0]; 0 [range, -1 to 0], respectively; all, P < .001). Mean interobserver correlation was 0.9 for image perception and 0.7 for artifacts. Objective noise for FBP was 14%-68% higher and for MBIR was 18%-47% lower than that for ASIR (P < .001). The MBIR algorithm considerably improved objective and subjective image quality parameters of routine abdominal multidetector CT images compared with those of ASIR and FBP.
- 9 September 2010
- Published by Springer Nature in Der Radiologe
- Vol. 50 (10) , 879-886
Angiographische Diagnostik akraler Durchblutungsstörungen an der oberen Extremität
Ischämische Läsionen betreffen nur selten die oberen Extremitäten. Anders als im Bereich der Füße und Zehen ist die Mehrzahl der Läsionen nicht atherosklerotisch bedingt, vielmehr spielen bei dieser Lokalisation entzündliche Gefäßerkrankungen eine wichtige Rolle in der Pathogenese. Akrale Durchblutungsstörungen werden sehr häufig durch ein Raynaud-Phänomen (RP) verursacht, das nicht zwangsläufig mit ischämischen Läsionen einhergeht. Es tritt meist idiopathisch auf, ist aber auch ein häufiges Haupt- und Begleitsymptom verschiedener Autoimmunerkrankungen und entzündlicher Gefäßerkrankungen. Aufgrund ihrer hohen Bildauflösung und der oft nur diskreten Befunde bei akralen Durchblutungsstörungen besitzt die DSA weiterhin einen hohen Stellenwert zur radiologischen Diagnostik der Handgefäße. Obwohl eine exakte Diagnosestellung ausschließlich vom angiographischen Befund ausgehend nicht immer möglich ist, gibt es doch für einige Erkrankungen typische Veränderungen und Verteilungsmuster. So sind, im Gegensatz zur Atherosklerose, wo sich die Arterien in der DSA mit irregulären Wandkonturen darstellen, bei einer Vaskulitis glatte Wandkonturen und oft zusätzliche Gefäßspasmen charakteristisch (insbesondere bei Thromboangiitis obliterans und Sklerodermie). Für die Thromboangiitis obliterans ist ein Mischbild aus distalen Gefäßverschlüssen und korkenzieherartigen Kollateralgefäßen sowie dünnen Kollateralnetzen in späteren Krankheitsphasen typisch. Patienten mit Sklerodermie entwickeln distal lokalisierte, filiforme oder abrupte Gefäßverschlüsse mit nur geringer Kollateralenbildung und bei typischerweise symmetrischem Befall beider Hände. Typische Befunde der Panarteriitis nodosa sind dagegen disseminierte kurzstreckige Stenosen, Gefäßektasien und bei fortgeschrittener Erkrankung Mikroaneurysmen. Acral ischemic lesions rarely affect the upper extremities. While in the lower limbs atherosclerosis is responsible for the majority of lesions, vasculitis and autoimmune diseases play an important role in the pathogenesis of ischemic lesions of the upper limbs. A considerable number of acral circulatory disorders present with Raynaud’s phenomenon and often without associated necrosis. Raynaud’s phenomenon is mainly idiopathic but may also be secondary to underlying conditions, such as autoimmune diseases and vasculitis. Because of its high spatial resolution and the often discrete morphological findings digital subtraction angiography (DSA) is still an important diagnostic method in the radiological evaluation of acral circulatory disorders of the hand. Angiographic features of vasculitis are not strictly pathognomonic but certain morphologic DSA findings are very typical and may allow for a radiologic diagnosis. For instance, atherosclerosis results in irregular contours of vessel walls in DSA in contrast to autoimmune diseases and vasculitis, which are usually characterized by smooth vessel walls and optional vasospasm, the latter being especially typical for thromboangiitis obliterans and scleroderma. In thromboangiitis obliterans occlusions of the distal hand arteries, corkscrew collateral vessels and subsequent development of fine collateral networks are typical findings. Abrupt or filiform occlusions of distal finger arteries with sparse collateralization and symmetric affection of both hands are suggestive of scleroderma. Disseminated segmental ectasis and stenosis as well as microaneurysms (63% of all patients) are very common in patients with panarteriitis nodosa.
- 9 September 2010
- Published by Springer Nature in Der Radiologe
- Vol. 50 (10) , 879-886
Angiographische Diagnostik akraler Durchblutungsstörungen an der oberen Extremität
Ischämische Läsionen betreffen nur selten die oberen Extremitäten. Anders als im Bereich der Füße und Zehen ist die Mehrzahl der Läsionen nicht atherosklerotisch bedingt, vielmehr spielen bei dieser Lokalisation entzündliche Gefäßerkrankungen eine wichtige Rolle in der Pathogenese. Akrale Durchblutungsstörungen werden sehr häufig durch ein Raynaud-Phänomen (RP) verursacht, das nicht zwangsläufig mit ischämischen Läsionen einhergeht. Es tritt meist idiopathisch auf, ist aber auch ein häufiges Haupt- und Begleitsymptom verschiedener Autoimmunerkrankungen und entzündlicher Gefäßerkrankungen. Aufgrund ihrer hohen Bildauflösung und der oft nur diskreten Befunde bei akralen Durchblutungsstörungen besitzt die DSA weiterhin einen hohen Stellenwert zur radiologischen Diagnostik der Handgefäße. Obwohl eine exakte Diagnosestellung ausschließlich vom angiographischen Befund ausgehend nicht immer möglich ist, gibt es doch für einige Erkrankungen typische Veränderungen und Verteilungsmuster. So sind, im Gegensatz zur Atherosklerose, wo sich die Arterien in der DSA mit irregulären Wandkonturen darstellen, bei einer Vaskulitis glatte Wandkonturen und oft zusätzliche Gefäßspasmen charakteristisch (insbesondere bei Thromboangiitis obliterans und Sklerodermie). Für die Thromboangiitis obliterans ist ein Mischbild aus distalen Gefäßverschlüssen und korkenzieherartigen Kollateralgefäßen sowie dünnen Kollateralnetzen in späteren Krankheitsphasen typisch. Patienten mit Sklerodermie entwickeln distal lokalisierte, filiforme oder abrupte Gefäßverschlüsse mit nur geringer Kollateralenbildung und bei typischerweise symmetrischem Befall beider Hände. Typische Befunde der Panarteriitis nodosa sind dagegen disseminierte kurzstreckige Stenosen, Gefäßektasien und bei fortgeschrittener Erkrankung Mikroaneurysmen. Acral ischemic lesions rarely affect the upper extremities. While in the lower limbs atherosclerosis is responsible for the majority of lesions, vasculitis and autoimmune diseases play an important role in the pathogenesis of ischemic lesions of the upper limbs. A considerable number of acral circulatory disorders present with Raynaud’s phenomenon and often without associated necrosis. Raynaud’s phenomenon is mainly idiopathic but may also be secondary to underlying conditions, such as autoimmune diseases and vasculitis. Because of its high spatial resolution and the often discrete morphological findings digital subtraction angiography (DSA) is still an important diagnostic method in the radiological evaluation of acral circulatory disorders of the hand. Angiographic features of vasculitis are not strictly pathognomonic but certain morphologic DSA findings are very typical and may allow for a radiologic diagnosis. For instance, atherosclerosis results in irregular contours of vessel walls in DSA in contrast to autoimmune diseases and vasculitis, which are usually characterized by smooth vessel walls and optional vasospasm, the latter being especially typical for thromboangiitis obliterans and scleroderma. In thromboangiitis obliterans occlusions of the distal hand arteries, corkscrew collateral vessels and subsequent development of fine collateral networks are typical findings. Abrupt or filiform occlusions of distal finger arteries with sparse collateralization and symmetric affection of both hands are suggestive of scleroderma. Disseminated segmental ectasis and stenosis as well as microaneurysms (63% of all patients) are very common in patients with panarteriitis nodosa.
- 1 January 2010
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 17 (3) , 283-9
Rotational thrombectomy of acute peripheral vascular occlusions with the thromcat xt device: technique, indications and first results
To gather initial procedural experiences with the ThromCat XT, a new rotational thrombectomy catheter primarily developed for coronary interventions. The ThromCat XT is a 150-cm rapid exchange thrombectomy device consisting of an atraumatic tip and a steel helix with a kink-resistant covering. It was employed in native arteries, veins, grafts and stents in ten patients presenting with acute and subacute thrombembolic occlusions. Technical success with a restoration of flow was achieved in 70% of patients. The mean thrombectomy time was 8.0±2.33 min, and the aspirated blood volume ranged from 120 mL to 280 mL. Peripheral thrombembolism was detected in two cases, and embolic protection was applied in four cases. Vessel injuries and catheter failures were not observed in any of the cases. The ThromCat XT is an easy-to-handle, reliable and atraumatic device for the removal of fresh thrombi in native and artificial vessels. In our series, the thrombus age-especially if greater than five days-had a major impact on technical success.
- 1 January 2010
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 17 (3) , 283-9
Rotational thrombectomy of acute peripheral vascular occlusions with the thromcat xt device: technique, indications and first results
To gather initial procedural experiences with the ThromCat XT, a new rotational thrombectomy catheter primarily developed for coronary interventions. The ThromCat XT is a 150-cm rapid exchange thrombectomy device consisting of an atraumatic tip and a steel helix with a kink-resistant covering. It was employed in native arteries, veins, grafts and stents in ten patients presenting with acute and subacute thrombembolic occlusions. Technical success with a restoration of flow was achieved in 70% of patients. The mean thrombectomy time was 8.0±2.33 min, and the aspirated blood volume ranged from 120 mL to 280 mL. Peripheral thrombembolism was detected in two cases, and embolic protection was applied in four cases. Vessel injuries and catheter failures were not observed in any of the cases. The ThromCat XT is an easy-to-handle, reliable and atraumatic device for the removal of fresh thrombi in native and artificial vessels. In our series, the thrombus age-especially if greater than five days-had a major impact on technical success.