Ricardo C. Cury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ricardo C. Cury has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Suhny Abbara
Department of Radiology, Mayo Clinic, Jacksonville, Fla
6 shared publications Thomas J. Brady
6 shared publicationsKoen Nieman
4 shared publicationsMaros Ferencik
4 shared publicationsUdo Hoffmann
4 shared publicationsFabian Moselewski
3 shared publications
Latest Publications
- Open Access
- 3 January 2013
- Published by Springer Nature in BMC Research Notes
- Vol. 6 (1) , 2
Clinical experiences of delayed contrast enhancement with cardiac computed tomography: case series
Myocardial delayed enhancement (MDE) by gadolinium-enhanced cardiac MRI is well established for myocardial scar assessment in ischemic and non-ischemic heart disease. The role of MDE by cardiac CT (CT-MDE) is not yet defined.
- 3 January 2013
- Published by Springer Nature in BMC Research Notes
- Vol. 6 (1) , 2
Open AccessClinical experiences of delayed contrast enhancement with cardiac computed tomography: case series
Myocardial delayed enhancement (MDE) by gadolinium-enhanced cardiac MRI is well established for myocardial scar assessment in ischemic and non-ischemic heart disease. The role of MDE by cardiac CT (CT-MDE) is not yet defined.
- 1 August 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 248 (2) , 466-475
Comprehensive Assessment of Myocardial Perfusion Defects, Regional Wall Motion, and Left Ventricular Function by Using 64-Section Multidetector CT
Sixty-four–section multidetector CT can accurately assess global and regional left ventricular function and resting myocardial perfusion defects in patients with and without acute myocardial infarction (MI). Comprehensive assessment of these functional parameters by using multidetector CT allows accurate detection of acute MI and may have prognostic implications. Purpose To evaluate the accuracy of 64-section multidetector computed tomography (CT) for the assessment of perfusion defects (PDs), regional wall motion (RWM), and global left ventricular (LV) function. Materials and Methods All myocardial infarction (MI) patients signed informed consent. The IRB approved the study and it was HIPAA-compliant. Cardiac multidetector CT was performed in 102 patients (34 with recent acute MI and 68 without). Multidetector CT images were analyzed for myocardial PD, RWM abnormalities, and LV function. Global LV function and RWM were compared with transthoracic echocardiography (TTE) by using multidetector CT. PD was detected by using multidetector CT and was correlated with cardiac biomarkers and single photon emission CT (SPECT) myocardial perfusion imaging. Multidetector CT diagnosis of acute MI was made on the basis of matching the presence of PD with RWM abnormalities compared with clinical evaluation. Results Correlation between multidetector CT and TTE for global functio...
- 1 August 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 248 (2) , 466-475
Comprehensive Assessment of Myocardial Perfusion Defects, Regional Wall Motion, and Left Ventricular Function by Using 64-Section Multidetector CT
Sixty-four–section multidetector CT can accurately assess global and regional left ventricular function and resting myocardial perfusion defects in patients with and without acute myocardial infarction (MI). Comprehensive assessment of these functional parameters by using multidetector CT allows accurate detection of acute MI and may have prognostic implications. Purpose To evaluate the accuracy of 64-section multidetector computed tomography (CT) for the assessment of perfusion defects (PDs), regional wall motion (RWM), and global left ventricular (LV) function. Materials and Methods All myocardial infarction (MI) patients signed informed consent. The IRB approved the study and it was HIPAA-compliant. Cardiac multidetector CT was performed in 102 patients (34 with recent acute MI and 68 without). Multidetector CT images were analyzed for myocardial PD, RWM abnormalities, and LV function. Global LV function and RWM were compared with transthoracic echocardiography (TTE) by using multidetector CT. PD was detected by using multidetector CT and was correlated with cardiac biomarkers and single photon emission CT (SPECT) myocardial perfusion imaging. Multidetector CT diagnosis of acute MI was made on the basis of matching the presence of PD with RWM abnormalities compared with clinical evaluation. Results Correlation between multidetector CT and TTE for global functio...
- 1 February 2008
- Published by Wolters Kluwer Health in Topics in Magnetic Resonance Imaging
- Vol. 19 (1) , 1-2
Cardiac Magnetic Resonance Imaging
- 1 February 2008
- Published by Wolters Kluwer Health in Topics in Magnetic Resonance Imaging
- Vol. 19 (1) , 1-2
Cardiac Magnetic Resonance Imaging
- 1 April 2007
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 14 (2) , 229-243
Comprehensive cardiac CT study: Evaluation of coronary arteries, left ventricular function, and myocardial perfusion—Is it possible?
- 1 April 2007
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 14 (2) , 229-243
Comprehensive cardiac CT study: Evaluation of coronary arteries, left ventricular function, and myocardial perfusion—Is it possible?
- 1 July 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 240 (1) , 39-45
Diagnostic Performance of Stress Perfusion and Delayed-Enhancement MR Imaging in Patients with Coronary Artery Disease
To prospectively determine the accuracy of a combined magnetic resonance (MR) imaging approach (stress first-pass perfusion imaging followed by delayed-enhancement imaging) for depicting clinically significant coronary artery stenosis (> or = 70% stenosis) in patients suspected of having or known to have coronary artery disease (CAD), with coronary angiography serving as the reference standard. The committee on human research approved the study protocol, and all participants gave written informed consent. This study was HIPAA compliant. Forty-seven patients (38 men and nine women; mean age, 63 years +/- 5.3 [standard deviation]) scheduled for coronary angiography were prospectively enrolled: 33 were suspected of having CAD (group A) and 14 had experienced a previous myocardial infarction and were suspected of having new lesions (group B). The MR imaging protocol included cine function, gadolinium-enhanced stress and rest first-pass perfusion MR imaging, and delayed-enhancement MR imaging. Myocardial ischemia was defined as a segment with perfusion deficit at stress first-pass perfusion MR imaging and no hyperenhancement at delayed-enhancement imaging. Myocardial infarction was defined as an area with hyperenhancement at delayed-enhancement imaging. One patient was excluded from analysis because of poor-quality MR images. Coronary angiography depicted significant stenosis in 30 of 46 patients (65%). In a per-vessel analysis (n = 138), stress first-pass perfusion MR imaging and delayed-enhancement imaging yielded sensitivity of 0.87, specificity of 0.89, and accuracy of 0.88, when compared with coronary angiography. The diagnostic accuracy of stress first-pass perfusion MR imaging and delayed-enhancement imaging was slightly better than that of stress and rest first-pass perfusion MR imaging in the entire population (0.88 vs 0.85), in group A (0.86 vs 0.82), and in group B (0.93 vs 0.90). Stress first-pass perfusion MR imaging followed by delayed-enhancement imaging is an accurate method to depict significant coronary stenosis in patients suspected of having or known to have CAD.
- 1 July 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 240 (1) , 39-45
Diagnostic Performance of Stress Perfusion and Delayed-Enhancement MR Imaging in Patients with Coronary Artery Disease
To prospectively determine the accuracy of a combined magnetic resonance (MR) imaging approach (stress first-pass perfusion imaging followed by delayed-enhancement imaging) for depicting clinically significant coronary artery stenosis (> or = 70% stenosis) in patients suspected of having or known to have coronary artery disease (CAD), with coronary angiography serving as the reference standard. The committee on human research approved the study protocol, and all participants gave written informed consent. This study was HIPAA compliant. Forty-seven patients (38 men and nine women; mean age, 63 years +/- 5.3 [standard deviation]) scheduled for coronary angiography were prospectively enrolled: 33 were suspected of having CAD (group A) and 14 had experienced a previous myocardial infarction and were suspected of having new lesions (group B). The MR imaging protocol included cine function, gadolinium-enhanced stress and rest first-pass perfusion MR imaging, and delayed-enhancement MR imaging. Myocardial ischemia was defined as a segment with perfusion deficit at stress first-pass perfusion MR imaging and no hyperenhancement at delayed-enhancement imaging. Myocardial infarction was defined as an area with hyperenhancement at delayed-enhancement imaging. One patient was excluded from analysis because of poor-quality MR images. Coronary angiography depicted significant stenosis in 30 of 46 patients (65%). In a per-vessel analysis (n = 138), stress first-pass perfusion MR imaging and delayed-enhancement imaging yielded sensitivity of 0.87, specificity of 0.89, and accuracy of 0.88, when compared with coronary angiography. The diagnostic accuracy of stress first-pass perfusion MR imaging and delayed-enhancement imaging was slightly better than that of stress and rest first-pass perfusion MR imaging in the entire population (0.88 vs 0.85), in group A (0.86 vs 0.82), and in group B (0.93 vs 0.90). Stress first-pass perfusion MR imaging followed by delayed-enhancement imaging is an accurate method to depict significant coronary stenosis in patients suspected of having or known to have CAD.
- 1 March 2006
- Published by Elsevier in European Journal of Radiology
- Vol. 57 (3) , 345-350
Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions
- 1 March 2006
- Published by Elsevier in European Journal of Radiology
- Vol. 57 (3) , 345-350
Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions
- 1 September 2005
- Published by Elsevier in The American Journal of Cardiology
- Vol. 96 (6) , 784-787
Comparison of the Degree of Coronary Stenoses by Multidetector Computed Tomography Versus by Quantitative Coronary Angiography
- 1 September 2005
- Published by Elsevier in The American Journal of Cardiology
- Vol. 96 (6) , 784-787
Comparison of the Degree of Coronary Stenoses by Multidetector Computed Tomography Versus by Quantitative Coronary Angiography
- 8 March 2005
- Published by Wolters Kluwer Health in Circulation
- Vol. 111 (9) , e115-7
Visualization of Endomyocardial Fibrosis by Delayed-Enhancement Magnetic Resonance Imaging
- 8 March 2005
- Published by Wolters Kluwer Health in Circulation
- Vol. 111 (9) , e115-7
Visualization of Endomyocardial Fibrosis by Delayed-Enhancement Magnetic Resonance Imaging
- 1 August 2004
- Published by Elsevier in The American Journal of Cardiology
- Vol. 94 (3) , 348-351
Epidemiology and association of vascular and valvular calcium quantified by multidetector computed tomography in elderly asymptomatic subjects**Any opinions, findings, conclusions, or recommendations expressed in this publication are those of the investigators and do not necessarily reflect the view of the US Department of Agriculture.
- 1 August 2004
- Published by Elsevier in The American Journal of Cardiology
- Vol. 94 (3) , 348-351
Epidemiology and association of vascular and valvular calcium quantified by multidetector computed tomography in elderly asymptomatic subjects**Any opinions, findings, conclusions, or recommendations expressed in this publication are those of the investigators and do not necessarily reflect the view of the US Department of Agriculture.