Shudong Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shudong Jiang has a total of 206 co-authors. Here are the top co-authors by number of shared publications:
- Brian W. Pogue
Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
51 shared publications Keith D. Paulsen
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
27 shared publications- Keith D. Paulsen
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
20 shared publications - Xu Cao
University of Wisconsin-Madison
13 shared publications - Hamid Dehghani
University of Birmingham
8 shared publications Brian W. Pogue
Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
7 shared publications
Latest Publications
- 10 April 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (5) , 2282-2297
Latent diffusion-based image reconstruction for near-infrared spectral tomography
Near infrared spectral tomography (NIRST) is a promising non-invasive imaging technique that uses near-infrared light to probe the optical properties of biological tissue. However, due to light scattering in tissue, NIRST image reconstruction is inherently ill-posed and highly sensitive to noise. To address this challenge, an image reconstruction algorithm (Diff-NIRST), which integrated a conditional latent diffusion model, an image autoencoding module, and a conditional signal encoder, was developed. The image autoencoding module reduced image dimensionality to ensure compatibility with the latent space, while the conditional signal encoder transformed NIRST measurements into conditioning inputs for the generative process. The conditional latent diffusion model then reconstructed images of chromophore concentrations. Validation was performed through simulations. The method was subsequently applied to data from a patient case. In numerical simulations, 100 phantoms were reconstructed containing one or two inclusions with diameters of 4-14 mm and varying contrast ratios (CR) of total hemoglobin (HbT) and water content between inclusions and background. Diff-NIRST consistently outperformed conventional Tikhonov regularization and two other deep learning approaches, yielding an average improvement >17.1% in peak signal-to-noise ratio (PSNR), >48.3% and >23.5% reduction in CR error and size error (SE) for HbT, respectively. For water, it achieved an average >11% increase in PSNR, >16.7% and >57.1% reduction in CR error and SE, respectively. Application to breast cancer patient data further demonstrated that Diff-NIRST, trained solely on simulation data, successfully reconstructed clinical images, underscoring its translation potential.
- 10 April 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (5) , 2282-2297
Latent diffusion-based image reconstruction for near-infrared spectral tomography
Near infrared spectral tomography (NIRST) is a promising non-invasive imaging technique that uses near-infrared light to probe the optical properties of biological tissue. However, due to light scattering in tissue, NIRST image reconstruction is inherently ill-posed and highly sensitive to noise. To address this challenge, an image reconstruction algorithm (Diff-NIRST), which integrated a conditional latent diffusion model, an image autoencoding module, and a conditional signal encoder, was developed. The image autoencoding module reduced image dimensionality to ensure compatibility with the latent space, while the conditional signal encoder transformed NIRST measurements into conditioning inputs for the generative process. The conditional latent diffusion model then reconstructed images of chromophore concentrations. Validation was performed through simulations. The method was subsequently applied to data from a patient case. In numerical simulations, 100 phantoms were reconstructed containing one or two inclusions with diameters of 4-14 mm and varying contrast ratios (CR) of total hemoglobin (HbT) and water content between inclusions and background. Diff-NIRST consistently outperformed conventional Tikhonov regularization and two other deep learning approaches, yielding an average improvement >17.1% in peak signal-to-noise ratio (PSNR), >48.3% and >23.5% reduction in CR error and size error (SE) for HbT, respectively. For water, it achieved an average >11% increase in PSNR, >16.7% and >57.1% reduction in CR error and SE, respectively. Application to breast cancer patient data further demonstrated that Diff-NIRST, trained solely on simulation data, successfully reconstructed clinical images, underscoring its translation potential.
- 5 August 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (18) , 2031-2039
Intraoperative Bone Perfusion Assessment Using Fluorescence Imaging in a Simulated Fracture Model
Background: Accurate debridement of poorly perfused bone and soft tissue is critical to reduce the risk of infection in open fracture or of recurrent fracture-related infection (FRI). However, accurate delineation of viable and nonviable tissue is difficult with current technology. The aim of this pilot study was to develop and evaluate an indocyanine green (ICG)-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) strategy to provide intraoperative, objective, real-time information on bone perfusion using an osteotomy model in patients undergoing lower-extremity amputation. Methods: Fifteen patients who were ≥18 years of age and were undergoing lower-extremity amputation were included in this study. Perfusion-related kinetic parameters derived from DCE-FI, including maximum fluorescence intensity, ingress slope, and blood flow, were compared among 3 conditions reflecting sequentially increasing osseous damage: baseline, osteotomy (disruption of endosteal blood flow), and osteotomy plus periosteal stripping (disruption of endosteal and periosteal blood flow). Results: There were significant decreases in median values from baseline to after osteotomy alone for maximum intensity (96.2 to 58.9 relative fluorescence units [RFUs]), ingress slope (3.2 to 2.0 RFU/second), and blood flow (6.7 to 4.9 mL/min/100 g). Following osteotomy plus periosteal stripping, there were also significant decreases in median values for maximum intensity (12.0 RFU), ingress slope (0.2 RFU/s), and blood flow (0.8 mL/min/100 g). The Mann-Whitney U test confirmed a significant perfusion reduction (p < 0.001) in the tibial diaphysis due to these injuries. The areas under the curve (AUC) in the receiver operating characteristic (ROC) analysis for identifying periosteal stripping (compared with only osteotomy or no osseous damage) were 0.89 to 0.90, which were higher than the AUCs for identifying any osseous damage (osteotomy with or without periosteal stripping) compared with no damage, 0.75 to 0.82. Conclusions: This clinical study utilizing DCE-FI for intraoperative bone perfusion assessment in orthopaedic surgery demonstrated that kinetic variables derived from DCE-FI can effectively characterize and classify degradation of bone perfusion due to osteotomy and osteotomy plus periosteal stripping. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 5 August 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (18) , 2031-2039
Intraoperative Bone Perfusion Assessment Using Fluorescence Imaging in a Simulated Fracture Model
Background: Accurate debridement of poorly perfused bone and soft tissue is critical to reduce the risk of infection in open fracture or of recurrent fracture-related infection (FRI). However, accurate delineation of viable and nonviable tissue is difficult with current technology. The aim of this pilot study was to develop and evaluate an indocyanine green (ICG)-based dynamic contrast-enhanced fluorescence imaging (DCE-FI) strategy to provide intraoperative, objective, real-time information on bone perfusion using an osteotomy model in patients undergoing lower-extremity amputation. Methods: Fifteen patients who were ≥18 years of age and were undergoing lower-extremity amputation were included in this study. Perfusion-related kinetic parameters derived from DCE-FI, including maximum fluorescence intensity, ingress slope, and blood flow, were compared among 3 conditions reflecting sequentially increasing osseous damage: baseline, osteotomy (disruption of endosteal blood flow), and osteotomy plus periosteal stripping (disruption of endosteal and periosteal blood flow). Results: There were significant decreases in median values from baseline to after osteotomy alone for maximum intensity (96.2 to 58.9 relative fluorescence units [RFUs]), ingress slope (3.2 to 2.0 RFU/second), and blood flow (6.7 to 4.9 mL/min/100 g). Following osteotomy plus periosteal stripping, there were also significant decreases in median values for maximum intensity (12.0 RFU), ingress slope (0.2 RFU/s), and blood flow (0.8 mL/min/100 g). The Mann-Whitney U test confirmed a significant perfusion reduction (p < 0.001) in the tibial diaphysis due to these injuries. The areas under the curve (AUC) in the receiver operating characteristic (ROC) analysis for identifying periosteal stripping (compared with only osteotomy or no osseous damage) were 0.89 to 0.90, which were higher than the AUCs for identifying any osseous damage (osteotomy with or without periosteal stripping) compared with no damage, 0.75 to 0.82. Conclusions: This clinical study utilizing DCE-FI for intraoperative bone perfusion assessment in orthopaedic surgery demonstrated that kinetic variables derived from DCE-FI can effectively characterize and classify degradation of bone perfusion due to osteotomy and osteotomy plus periosteal stripping. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 29 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (11) , 4390-4403
Deep Learning Enables Fast and Accurate Quantification of MRI-Guided Near-Infrared Spectral Tomography for Breast Cancer Diagnosis
The utilization of magnetic resonance (MR) im-aging to guide near-infrared spectral tomography (NIRST) shows significant potential for improving the specificity and sensitivity of breast cancer diagnosis. However, the ef-ficiency and accuracy of NIRST image reconstruction have been limited by the complexities of light propagation mod-eling and MRI image segmentation. To address these chal-lenges, we developed and evaluated a deep learning-based approach for MR-guided 3D NIRST image reconstruction (DL-MRg-NIRST). Using a network trained on synthetic data, the DL-MRg-NIRST system reconstructed images from data acquired during 38 clinical imaging exams of pa-tients with breast abnormalities. Statistical analysis of the results demonstrated a sensitivity of 87.5%, a specificity of 92.9%, and a diagnostic accuracy of 89.5% in distinguishing pathologically defined benign from malignant lesions. Ad-ditionally, the combined use of MRI and DL-MRg-NIRST di-agnoses achieved an area under the receiver operating characteristic (ROC) curve of 0.98. Remarkably, the DL-MRg-NIRST image reconstruction process required only 1.4 seconds, significantly faster than state-of-the-art MR-guided NIRST methods.
- 29 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (11) , 4390-4403
Deep Learning Enables Fast and Accurate Quantification of MRI-Guided Near-Infrared Spectral Tomography for Breast Cancer Diagnosis
The utilization of magnetic resonance (MR) im-aging to guide near-infrared spectral tomography (NIRST) shows significant potential for improving the specificity and sensitivity of breast cancer diagnosis. However, the ef-ficiency and accuracy of NIRST image reconstruction have been limited by the complexities of light propagation mod-eling and MRI image segmentation. To address these chal-lenges, we developed and evaluated a deep learning-based approach for MR-guided 3D NIRST image reconstruction (DL-MRg-NIRST). Using a network trained on synthetic data, the DL-MRg-NIRST system reconstructed images from data acquired during 38 clinical imaging exams of pa-tients with breast abnormalities. Statistical analysis of the results demonstrated a sensitivity of 87.5%, a specificity of 92.9%, and a diagnostic accuracy of 89.5% in distinguishing pathologically defined benign from malignant lesions. Ad-ditionally, the combined use of MRI and DL-MRg-NIRST di-agnoses achieved an area under the receiver operating characteristic (ROC) curve of 0.98. Remarkably, the DL-MRg-NIRST image reconstruction process required only 1.4 seconds, significantly faster than state-of-the-art MR-guided NIRST methods.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2330-2340
Model-Based Convolution Neural Network for 3D Near-Infrared Spectral Tomography
Near-infrared spectral tomography (NIRST) is a non-invasive imaging technique that provides functional information about biological tissues. Due to diffuse light propagation in tissue and limited boundary measurements, NIRST image reconstruction presents an ill-posed and ill-conditioned computational problem that is difficult to solve. To address this challenge, we developed a reconstruction algorithm (Model-CNN) that integrates a diffusion equation model with a convolutional neural network (CNN). The CNN learns a regularization prior to restrict solutions to the space of desirable chromophore concentration images. Efficacy of Model-CNN was evaluated by training on numerical simulation data, and then applying the network to physical phantom and clinical patient NIRST data. Results demonstrated the superiority of Model-CNN over the conventional Tikhonov regularization approach and a deep learning algorithm (FC-CNN) in terms of absolute bias error (ABE) and peak signal-to-noise ratio (PSNR). Specifically, in comparison to Tikhonov regularization, Model-CNN reduced average ABE by 55% for total hemoglobin (HbT) and 70% water (H2O) concentration, while improved PSNR by an average of 5.3 dB both for HbT and H2O images. Meanwhile, image processing time was reduced by 82%, relative to the Tikhonov regularization. As compared to FC-CNN, the Model-CNN achieved a 91% reduction in ABE for HbT and 75% for H2O images, with increases in PSNR by 7.3 dB and 4.7 dB, respectively. Notably, this Model-CNN approach was not trained on patient data; but instead, was trained on simulated phantom data with simpler geometrical shapes and optical source-detector configurations; yet, achieved superior image recovery when faced with real-world data.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2330-2340
Model-Based Convolution Neural Network for 3D Near-Infrared Spectral Tomography
Near-infrared spectral tomography (NIRST) is a non-invasive imaging technique that provides functional information about biological tissues. Due to diffuse light propagation in tissue and limited boundary measurements, NIRST image reconstruction presents an ill-posed and ill-conditioned computational problem that is difficult to solve. To address this challenge, we developed a reconstruction algorithm (Model-CNN) that integrates a diffusion equation model with a convolutional neural network (CNN). The CNN learns a regularization prior to restrict solutions to the space of desirable chromophore concentration images. Efficacy of Model-CNN was evaluated by training on numerical simulation data, and then applying the network to physical phantom and clinical patient NIRST data. Results demonstrated the superiority of Model-CNN over the conventional Tikhonov regularization approach and a deep learning algorithm (FC-CNN) in terms of absolute bias error (ABE) and peak signal-to-noise ratio (PSNR). Specifically, in comparison to Tikhonov regularization, Model-CNN reduced average ABE by 55% for total hemoglobin (HbT) and 70% water (H2O) concentration, while improved PSNR by an average of 5.3 dB both for HbT and H2O images. Meanwhile, image processing time was reduced by 82%, relative to the Tikhonov regularization. As compared to FC-CNN, the Model-CNN achieved a 91% reduction in ABE for HbT and 75% for H2O images, with increases in PSNR by 7.3 dB and 4.7 dB, respectively. Notably, this Model-CNN approach was not trained on patient data; but instead, was trained on simulated phantom data with simpler geometrical shapes and optical source-detector configurations; yet, achieved superior image recovery when faced with real-world data.
- Open Access
- 18 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (S1) , S13709-16
Combined dual-channel fluorescence depth sensing of indocyanine green and protoporphyrin IX kinetics in subcutaneous murine tumors
Biomedical optical sensing can be used to extract multidimensional molecular and functional information from tissues when combined with appropriate reporter molecules. Within this area, fluorescence sensing provides one of the most specific strategies for high-sensitivity information about tissue, and there are several dyes available for use.1 – 3 The most commonly used human reporters are in the near-infrared (NIR) and red wavelength bands due to high penetration through deep tissue.4 In this study, a prototype system was developed that could passively switch between two fluorophores to measure fluorescent signals through sub-surface tissue volumes in a small probe-style geometry. In addition, the system was designed to achieve deep tissue sampling, allowing for measurement well below the tissue surface. Both of these are described below along with the prototype design. The fluorescent agent most widely utilized in humans is indocyanine green (ICG), a perfusion probe tracer for assessing tissue vascular function,5 which exhibits peak fluorescence emission at around 830 nm and peak absorption at roughly 780 nm. ICG-aided diagnosis has become a common practice in certain neurovascular and gastrointestinal surgeries and for general tissue perfusion/function assessment.6 In addition, the next most commonly used agent is protoporphyrin IX (PpIX), a molecule universally produced in all living organisms and present in all living cells, with an endogenous production that is stimulated in vivo through the administration of the PpIX precursor molecule 5-aminolevulinic acid (5-ALA).7,8 PpIX produces a reasonably bright red-NIR fluorescence at wavelengths 635 to 720 nm, which can be imaged superficially with blue light excitation at 405 nm or more deeply with red 635-nm excitation. The ability to image both of these human-use fluorophores with the same system was part of the goal of our prototype fluorescence depth sampling system.9 The development of a system that could simultaneously measure these two fluorophores could have an inherent value because the ICG signal indicates vascular flow/perfusion, whereas the PpIX signal indicates the metabolic function of heme synthesis. Both of these signals have unique relevance to tumors and their signal changes with tumor growth and response to therapies.9 – 11
- 18 November 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (S1) , S13709-16
Open AccessCombined dual-channel fluorescence depth sensing of indocyanine green and protoporphyrin IX kinetics in subcutaneous murine tumors
Biomedical optical sensing can be used to extract multidimensional molecular and functional information from tissues when combined with appropriate reporter molecules. Within this area, fluorescence sensing provides one of the most specific strategies for high-sensitivity information about tissue, and there are several dyes available for use.1 – 3 The most commonly used human reporters are in the near-infrared (NIR) and red wavelength bands due to high penetration through deep tissue.4 In this study, a prototype system was developed that could passively switch between two fluorophores to measure fluorescent signals through sub-surface tissue volumes in a small probe-style geometry. In addition, the system was designed to achieve deep tissue sampling, allowing for measurement well below the tissue surface. Both of these are described below along with the prototype design. The fluorescent agent most widely utilized in humans is indocyanine green (ICG), a perfusion probe tracer for assessing tissue vascular function,5 which exhibits peak fluorescence emission at around 830 nm and peak absorption at roughly 780 nm. ICG-aided diagnosis has become a common practice in certain neurovascular and gastrointestinal surgeries and for general tissue perfusion/function assessment.6 In addition, the next most commonly used agent is protoporphyrin IX (PpIX), a molecule universally produced in all living organisms and present in all living cells, with an endogenous production that is stimulated in vivo through the administration of the PpIX precursor molecule 5-aminolevulinic acid (5-ALA).7,8 PpIX produces a reasonably bright red-NIR fluorescence at wavelengths 635 to 720 nm, which can be imaged superficially with blue light excitation at 405 nm or more deeply with red 635-nm excitation. The ability to image both of these human-use fluorophores with the same system was part of the goal of our prototype fluorescence depth sampling system.9 The development of a system that could simultaneously measure these two fluorophores could have an inherent value because the ICG signal indicates vascular flow/perfusion, whereas the PpIX signal indicates the metabolic function of heme synthesis. Both of these signals have unique relevance to tumors and their signal changes with tumor growth and response to therapies.9 – 11
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (3) , 899-908
MRI-Guided Near-Infrared Spectroscopic Tomography (MRg-NIRST) Imaging System With Wearable Breast Optical Interface for Breast Cancer Imaging
Objective: To develop a novel Magnetic Resonance Imaging (MRI)-guided Near-Infrared Spectroscopic Tomography (MRg-NIRST) imaging system with an MRI-compatible breast optical interface for breast imaging. Methods: The breast interface consists of eight flexible opto-electronic circuit strips, each equipped with six photodetectors and six side-firing fiber-probes. Concurrent MRI and NIRST data were acquired from a total of 2,304 source-detector positions at six wavelengths, enabling 3D MRg-NIRST image reconstruction of the entire breast. The system was validated through a series of phantom and normal subject studies. Results: Reconstructed images of phantoms with inclusions ranging 10–25 mm in diameter showed errors in the estimated inclusion diameter and contrast of total hemoglobin (HbT) within the inclusion relative to the background were ranged in [−7%, 12%] and [7%, 28%], respectively. HbT estimates from reconstructed images of nine normal subjects ranged between 8.0–l25.2 μM, align with previous imaging studies. Conclusion: Results from both phantom and normal subject studies indicate that this system has the potential to be easily integrated into clinical practice for acquiring 3D MRg-NIRST images of the entire breast. Significance: The flexibility of the wearable breast optical interface, along with the increased number of sources and detectors, has improved the optical accessibility for breasts of various sizes, shapes, and tumor locations. 3D MRg-NIRST image reconstruction, based on optical data collected from multiple source-detector layers across the entire breast, demonstrates that MRg-NIRST is ready to be tested clinically for its potential to enhance breast cancer detection alongside MRI.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (3) , 899-908
MRI-Guided Near-Infrared Spectroscopic Tomography (MRg-NIRST) Imaging System With Wearable Breast Optical Interface for Breast Cancer Imaging
Objective: To develop a novel Magnetic Resonance Imaging (MRI)-guided Near-Infrared Spectroscopic Tomography (MRg-NIRST) imaging system with an MRI-compatible breast optical interface for breast imaging. Methods: The breast interface consists of eight flexible opto-electronic circuit strips, each equipped with six photodetectors and six side-firing fiber-probes. Concurrent MRI and NIRST data were acquired from a total of 2,304 source-detector positions at six wavelengths, enabling 3D MRg-NIRST image reconstruction of the entire breast. The system was validated through a series of phantom and normal subject studies. Results: Reconstructed images of phantoms with inclusions ranging 10–25 mm in diameter showed errors in the estimated inclusion diameter and contrast of total hemoglobin (HbT) within the inclusion relative to the background were ranged in [−7%, 12%] and [7%, 28%], respectively. HbT estimates from reconstructed images of nine normal subjects ranged between 8.0–l25.2 μM, align with previous imaging studies. Conclusion: Results from both phantom and normal subject studies indicate that this system has the potential to be easily integrated into clinical practice for acquiring 3D MRg-NIRST images of the entire breast. Significance: The flexibility of the wearable breast optical interface, along with the increased number of sources and detectors, has improved the optical accessibility for breasts of various sizes, shapes, and tumor locations. 3D MRg-NIRST image reconstruction, based on optical data collected from multiple source-detector layers across the entire breast, demonstrates that MRg-NIRST is ready to be tested clinically for its potential to enhance breast cancer detection alongside MRI.
- Open Access
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33306-17
Patient-specific arterial input function for accurate perfusion assessment in intraoperative fluorescence imaging
SignificanceThe arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green–based dynamic contrast-enhanced fluorescence imaging (DCE-FI).AimWe evaluate the impact of the AIF on perfusion assessment through DCE-FI.ApproachA total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF.ResultsIndividual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate (kep), maximum intensity (Imax), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant (Ktrans), and time to peak.ConclusionsIndividual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33306-17
Open AccessPatient-specific arterial input function for accurate perfusion assessment in intraoperative fluorescence imaging
SignificanceThe arterial input function (AIF) plays a crucial role in correcting the time-dependent concentration of the contrast agent within the arterial system, accounting for variations in agent injection parameters (speed, timing, etc.) across patients. Understanding the significance of the AIF can enhance the accuracy of tissue vascular perfusion assessment through indocyanine green–based dynamic contrast-enhanced fluorescence imaging (DCE-FI).AimWe evaluate the impact of the AIF on perfusion assessment through DCE-FI.ApproachA total of 144 AIFs were acquired from 110 patients using a pulse dye densitometer. Simulation and patient intraoperative imaging were conducted to validate the significance of AIF for perfusion assessment based on kinetic parameters extracted from fluorescence images before and after AIF correction. The kinetic model accuracy was evaluated by assessing the variability of kinetic parameters using individual AIF versus population-based AIF.ResultsIndividual AIF can reduce the variability in kinetic parameters, and population-based AIF can potentially replace individual AIF for estimating wash-out rate (kep), maximum intensity (Imax), ingress slope with lower differences compared with those in estimating blood flow, volume transfer constant (Ktrans), and time to peak.ConclusionsIndividual AIF can provide the most accurate perfusion assessment compared with assessment without AIF or based on population-based AIF correction.
- 1 January 2024
- Published by Optica Publishing Group
- p. TS1B.6
MRI guide NIR spectral tomography (NIRST) system for breast cancer detection
Phantom and normal subject studies have been carried out to validate the performance of a novel wearable optical breast interface-based MRI-guided near-infrared spectroscopic tomographic (MRg-NIRST) imaging system for breast cancer detection.
- 1 January 2024
- Published by Optica Publishing Group
- p. TS1B.6
MRI guide NIR spectral tomography (NIRST) system for breast cancer detection
Phantom and normal subject studies have been carried out to validate the performance of a novel wearable optical breast interface-based MRI-guided near-infrared spectroscopic tomographic (MRg-NIRST) imaging system for breast cancer detection.
- Open Access
- 1 January 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (01) , 016001-12
Automatic correction of motion artifact in dynamic contrast-enhanced fluorescence imaging during open orthopedic surgery
Infection following trauma is one of the most prevalent and challenging complications faced by orthopedic surgeons. Inadequate tissue perfusion plays a critical role in this complication since poorly perfused bone can be a nidus for bacterial biofilm formation creating resistance to antibiotics.1,2 These biofilms make treatment of infections difficult as they increase the bacteria’s ability to evade the immune system, share antibiotic resistant genes, and proliferate additional planktonic bacteria.3 Because of this, management of open fractures and fracture-related infection relies on aggressive and thorough debridement in an effort to remove all poorly perfused bone.4,5 However, there is a limited number of imaging tools to objectively inform bone perfusion and guide debridement.
- 1 January 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (01) , 016001-12
Open AccessAutomatic correction of motion artifact in dynamic contrast-enhanced fluorescence imaging during open orthopedic surgery
Infection following trauma is one of the most prevalent and challenging complications faced by orthopedic surgeons. Inadequate tissue perfusion plays a critical role in this complication since poorly perfused bone can be a nidus for bacterial biofilm formation creating resistance to antibiotics.1,2 These biofilms make treatment of infections difficult as they increase the bacteria’s ability to evade the immune system, share antibiotic resistant genes, and proliferate additional planktonic bacteria.3 Because of this, management of open fractures and fracture-related infection relies on aggressive and thorough debridement in an effort to remove all poorly perfused bone.4,5 However, there is a limited number of imaging tools to objectively inform bone perfusion and guide debridement.