Roberto M. Lang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roberto M. Lang has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
- Victor Mor-Avi
University of Chicago Medical Center, Chicago, Illinois, USA
16 shared publications Lynn Weinert
University of Chicago Medical Center, Chicago, Illinois
15 shared publicationsKarima Addetia
University of Chicago , 5758 S. Maryland Avenue, MC 9067, DCAM 5509, Chicago, IL 60637 , USA
12 shared publicationsVictor Mor-Avi
Department of Medicine, Section of Cardiology, University of Chicago Medical Center, Chicago, Illinois
10 shared publications- Lissa Sugeng
Section of Cardiology, Department of Medicine, University of Chicago Medical Center, Chicago, Illinois 60637, USA
9 shared publications Lissa Sugeng
University of Chicago Medical Center, Chicago, Illinois; and
6 shared publications
Latest Publications
- 5 January 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (2) , 195-202
Automated analysis of echocardiographic images: do different artificial intelligence tools provide concordant measurements?
The use of artificial intelligence (AI) in echocardiography has been growing continuously, particularly in chamber quantification and disease detection. Although studies have validated different AI approaches for automated quantification of cardiac size and function, it is unknown whether different AI software tools provide concordant measurements. Accordingly, we aimed to: (1) evaluate the inter-software variability of the automated, AI-based measurements, and (2) compare their variability to that of conventional measurements performed by expert readers.Echocardiographic images from 116 randomly selected subjects, including 66 patients with cardiac pathology and 50 healthy volunteers were analyzed to obtain the following: (1) linear measurements: end-diastolic left ventricular internal diameter (LVIDd), basal right ventricular diameter (RVDd), and LV posterior wall thickness (LVPWd), (2) Doppler measurements (e’ lateral, e’ septal, mitral inflow E/A ratio), and (3) end-diastolic and end-systolic left ventricular volumes (LVEDV, LVESV), ejection fraction (LVEF), and end-systolic left atrial volume (LAESV). These measurements were performed by: (1) two fully automated AI-based software tools (Us2.AI and Philips), and (2) two expert readers using guidelines recommended methodology. Inter-software and inter-observer variability were assessed by percent absolute difference (PAD) and intraclass correlation coefficients (ICC) between corresponding measurements.AI measurements differed from each other, with the differences reaching significance for 6/10 parameters, while conventional measurements by experts significantly differed from each other for 3/10 parameters. Overall, the variability between AI tools was similar to the conventional methodology, with smaller PAD and higher ICC values noted for 6/10 and 2/10 parameters, respectively. Although different commercial AI-based tools for automated analysis of echocardiographic images do not provide identical results, the variability in the majority of these measurements was similar to or better than that of experts using the conventional methodology. Further studies are needed to ascertain these findings for other AI algorithms and larger numbers of readers and parameters.
- 5 January 2026
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 42 (2) , 195-202
Automated analysis of echocardiographic images: do different artificial intelligence tools provide concordant measurements?
The use of artificial intelligence (AI) in echocardiography has been growing continuously, particularly in chamber quantification and disease detection. Although studies have validated different AI approaches for automated quantification of cardiac size and function, it is unknown whether different AI software tools provide concordant measurements. Accordingly, we aimed to: (1) evaluate the inter-software variability of the automated, AI-based measurements, and (2) compare their variability to that of conventional measurements performed by expert readers.Echocardiographic images from 116 randomly selected subjects, including 66 patients with cardiac pathology and 50 healthy volunteers were analyzed to obtain the following: (1) linear measurements: end-diastolic left ventricular internal diameter (LVIDd), basal right ventricular diameter (RVDd), and LV posterior wall thickness (LVPWd), (2) Doppler measurements (e’ lateral, e’ septal, mitral inflow E/A ratio), and (3) end-diastolic and end-systolic left ventricular volumes (LVEDV, LVESV), ejection fraction (LVEF), and end-systolic left atrial volume (LAESV). These measurements were performed by: (1) two fully automated AI-based software tools (Us2.AI and Philips), and (2) two expert readers using guidelines recommended methodology. Inter-software and inter-observer variability were assessed by percent absolute difference (PAD) and intraclass correlation coefficients (ICC) between corresponding measurements.AI measurements differed from each other, with the differences reaching significance for 6/10 parameters, while conventional measurements by experts significantly differed from each other for 3/10 parameters. Overall, the variability between AI tools was similar to the conventional methodology, with smaller PAD and higher ICC values noted for 6/10 and 2/10 parameters, respectively. Although different commercial AI-based tools for automated analysis of echocardiographic images do not provide identical results, the variability in the majority of these measurements was similar to or better than that of experts using the conventional methodology. Further studies are needed to ascertain these findings for other AI algorithms and larger numbers of readers and parameters.
- Top Cited Papers
- 18 January 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 25 (6) , 754-761
Limitations of apical sparing pattern in cardiac amyloidosis: a multicentre echocardiographic study
Although impaired left ventricular (LV) global longitudinal strain (GLS) with apical sparing is a feature of cardiac amyloidosis (CA), its diagnostic accuracy has varied across studies. We aimed to determine the ability of apical sparing ratio (ASR) and most common echocardiographic parameters to differentiate patients with confirmed CA from those with clinical and/or echocardiographic suspicion of CA but with this diagnosis ruled out. We identified 544 patients with confirmed CA and 200 controls (CTRLs) as defined above (CTRL patients). Measurements from transthoracic echocardiograms were performed using artificial intelligence software (Us2.AI, Singapore) and audited by an experienced echocardiographer. Receiver operating characteristic curve analysis was used to evaluate the diagnostic performance and optimal cut-offs for the differentiation of CA patients from CTRL patients. Additionally, a group of 174 healthy subjects (healthy CTRL) was included to provide insight on how patients and healthy CTRLs differed echocardiographically. LV GLS was more impaired (−13.9 ± 4.6% vs. −15.9 ± 2.7%, P < 0.0005), and ASR was higher (2.4 ± 1.2 vs. 1.7 ± 0.9, P < 0.0005) in the CA group vs. CTRL patients. Relative wall thickness and ASR were the most accurate parameters for differentiating CA from CTRL patients [area under the curve (AUC): 0.77 and 0.74, respectively]. However, even with the optimal cut-off of 1.67, ASR was only 72% sensitive and 66% specific for CA, indicating the presence of apical sparing in 32% of CTRL patients and even in 6% healthy subjects. Apical sparing did not prove to be a CA-specific biomarker for accurate identification of CA, when compared with clinically similar CTRLs with no CA. Schematic workflow used for data collection and analysis.
- 18 January 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 25 (6) , 754-761
Top Cited PapersLimitations of apical sparing pattern in cardiac amyloidosis: a multicentre echocardiographic study
Although impaired left ventricular (LV) global longitudinal strain (GLS) with apical sparing is a feature of cardiac amyloidosis (CA), its diagnostic accuracy has varied across studies. We aimed to determine the ability of apical sparing ratio (ASR) and most common echocardiographic parameters to differentiate patients with confirmed CA from those with clinical and/or echocardiographic suspicion of CA but with this diagnosis ruled out. We identified 544 patients with confirmed CA and 200 controls (CTRLs) as defined above (CTRL patients). Measurements from transthoracic echocardiograms were performed using artificial intelligence software (Us2.AI, Singapore) and audited by an experienced echocardiographer. Receiver operating characteristic curve analysis was used to evaluate the diagnostic performance and optimal cut-offs for the differentiation of CA patients from CTRL patients. Additionally, a group of 174 healthy subjects (healthy CTRL) was included to provide insight on how patients and healthy CTRLs differed echocardiographically. LV GLS was more impaired (−13.9 ± 4.6% vs. −15.9 ± 2.7%, P < 0.0005), and ASR was higher (2.4 ± 1.2 vs. 1.7 ± 0.9, P < 0.0005) in the CA group vs. CTRL patients. Relative wall thickness and ASR were the most accurate parameters for differentiating CA from CTRL patients [area under the curve (AUC): 0.77 and 0.74, respectively]. However, even with the optimal cut-off of 1.67, ASR was only 72% sensitive and 66% specific for CA, indicating the presence of apical sparing in 32% of CTRL patients and even in 6% healthy subjects. Apical sparing did not prove to be a CA-specific biomarker for accurate identification of CA, when compared with clinically similar CTRLs with no CA. Schematic workflow used for data collection and analysis.
- 13 September 2023
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 36 (12) , 1290-1301
Preservation of Circumferential and Radial Left Ventricular Function as a Mitigating Mechanism for Impaired Longitudinal Strain in Early Cardiac Amyloidosis
- 13 September 2023
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 36 (12) , 1290-1301
Preservation of Circumferential and Radial Left Ventricular Function as a Mitigating Mechanism for Impaired Longitudinal Strain in Early Cardiac Amyloidosis
- 16 June 2023
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 36 (11) , 1215-1217
Semiautomated Quantification of the Tricuspid Annulus Using Three-Dimensional Echocardiography
- 16 June 2023
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 36 (11) , 1215-1217
Semiautomated Quantification of the Tricuspid Annulus Using Three-Dimensional Echocardiography
- 11 July 2022
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 35 (10) , 1009-1017.e2
Three-Dimensional Echocardiographic Deconstruction: Feasibility of Clinical Evaluation from Two-Dimensional Views Derived from a Three-Dimensional Data Set
- 11 July 2022
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 35 (10) , 1009-1017.e2
Three-Dimensional Echocardiographic Deconstruction: Feasibility of Clinical Evaluation from Two-Dimensional Views Derived from a Three-Dimensional Data Set
- 1 May 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 68, 190-196
Regional myocardial strain by cardiac magnetic resonance feature tracking for detection of scar in ischemic heart disease
- 1 May 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 68, 190-196
Regional myocardial strain by cardiac magnetic resonance feature tracking for detection of scar in ischemic heart disease
- 1 September 2019
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 12 (9) , 1868-1871
First Clinical Experience With 3-Dimensional Echocardiographic Transillumination Rendering
- 1 September 2019
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 12 (9) , 1868-1871
First Clinical Experience With 3-Dimensional Echocardiographic Transillumination Rendering
- 15 August 2019
- Published by Springer Nature
- p. 1-8
The Evolution of Three-Dimensional Echocardiography: From the Initial Concept to Real-Time Imaging
- 15 August 2019
- Published by Springer Nature
- p. 1-8
The Evolution of Three-Dimensional Echocardiography: From the Initial Concept to Real-Time Imaging