R. Scott Harris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
R. Scott Harris has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
José G. Venegas
Department of Medicine, Pulmonary and Critical Care Unit, and 2Anesthesia and Critical Care, Massachusetts General Hospital and Harvard Medical School, and 3Department of Biomedical Engineering, Boston University, Boston, Massachusetts
4 shared publications- Tilo Winkler
Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, USA
4 shared publications - Tobias Schroeder
GE Healthcare Surgery , 116 Huntington Avenue, Boston, Massachusetts 02116, USA
3 shared publications Guido Musch
Department of Medicine, Pulmonary and Critical Care Unit, and 2Anesthesia and Critical Care, Massachusetts General Hospital and Harvard Medical School, and 3Department of Biomedical Engineering, Boston University, Boston, Massachusetts
2 shared publications- Guido Musch
From the Department of Anesthesia, Critical Care, and Pain Medicine (G.M., T.W., M.F.V.M., T.J.W., N.d.P., J.G.V.), Department of Medicine, Pulmonary and Critical Care Unit (R.S.H.), and Department of Pathology (R.L.K.), Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
2 shared publications - Jose G. Venegas
Massachusetts General Hospital and Harvard Medical School , Boston, Massachusetts
2 shared publications
Latest Publications
- 1 July 2009
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 107 (1) , 266-274
The prone position results in smaller ventilation defects during bronchoconstriction in asthma
The effect of body posture on regional ventilation during bronchoconstriction is unknown. In five subjects with asthma, we measured spirometry, low-frequency (0.15-Hz) lung elastance, and resistance and regional ventilation by intravenous 13NN-saline positron emission tomography before and after nebulized methacholine. The subjects were imaged prone on 1 day and supine on another, but on both days the methacholine was delivered while prone. From the residual 13NN after washout, ventilation defective areas were defined, and their location, volume, ventilation, and fractional gas content relative to the rest of the lung were calculated. Independent of posture, all subjects developed ventilation defective areas. Although ventilation within these areas was similarly reduced in both postures, their volume was smaller in prone than supine (25 vs. 41%, P < 0.05). The geometric center of the ventilation defective areas was gravitationally dependent relative to that of the lung in both postures. Mean lung fractional gas content was greater in the prone position before methacholine and did not increase as much as in the supine position after methacholine. In the prone position at baseline, areas that became ventilation defects had lower gas content than the rest of the lung. In both positions at baseline, there was a gradient of gas content in the vertical direction. In asthma, the size and location of ventilation defects is affected by body position and likely affected by small differences in lung expansion during bronchoconstriction.
- 1 July 2009
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 107 (1) , 266-274
The prone position results in smaller ventilation defects during bronchoconstriction in asthma
The effect of body posture on regional ventilation during bronchoconstriction is unknown. In five subjects with asthma, we measured spirometry, low-frequency (0.15-Hz) lung elastance, and resistance and regional ventilation by intravenous 13NN-saline positron emission tomography before and after nebulized methacholine. The subjects were imaged prone on 1 day and supine on another, but on both days the methacholine was delivered while prone. From the residual 13NN after washout, ventilation defective areas were defined, and their location, volume, ventilation, and fractional gas content relative to the rest of the lung were calculated. Independent of posture, all subjects developed ventilation defective areas. Although ventilation within these areas was similarly reduced in both postures, their volume was smaller in prone than supine (25 vs. 41%, P < 0.05). The geometric center of the ventilation defective areas was gravitationally dependent relative to that of the lung in both postures. Mean lung fractional gas content was greater in the prone position before methacholine and did not increase as much as in the supine position after methacholine. In the prone position at baseline, areas that became ventilation defects had lower gas content than the rest of the lung. In both positions at baseline, there was a gradient of gas content in the vertical direction. In asthma, the size and location of ventilation defects is affected by body position and likely affected by small differences in lung expansion during bronchoconstriction.
- Open Access
- 31 January 2009
- Published by Springer Nature in Intensive Care Medicine
- Vol. 35 (4) , 740-747
A comparison of methods to identify open-lung PEEP
Forestry may cause adverse impacts on water quality, and the forestry planning process is a key factor for the outcome of forest operation effects on stream water. To optimise environmental considerations and to identify actions needed to improve or maintain the stream biodiversity, two silvicultural water management tools, BIS+ (biodiversity, impact, sensitivity and added values) and Blue targeting, have been developed. In this study, we evaluate the links between survey variables, based on BIS+ and Blue targeting data, and water chemistry in 173 randomly selected headwater streams in the hemiboreal zone. While BIS+ and Blue targeting cannot replace more sophisticated monitoring methods necessary for classifying water quality in streams according to the EU Water Framework Directive (WFD, 2000/60/EC), our results lend support to the idea that the BIS+ protocol can be used to prioritise the protection of riparian forests. The relationship between BIS+ and water quality indicators (concentrations of nutrients and organic matter) together with data from fish studies suggests that this field protocol can be used to give reaches with higher biodiversity and conservation values a better protection. The tools indicate an ability to mitigate forestry impacts on water quality if the operations are adjusted to this knowledge in located areas.
- 31 January 2009
- Published by Springer Nature in Intensive Care Medicine
- Vol. 35 (4) , 740-747
Open AccessA comparison of methods to identify open-lung PEEP
Forestry may cause adverse impacts on water quality, and the forestry planning process is a key factor for the outcome of forest operation effects on stream water. To optimise environmental considerations and to identify actions needed to improve or maintain the stream biodiversity, two silvicultural water management tools, BIS+ (biodiversity, impact, sensitivity and added values) and Blue targeting, have been developed. In this study, we evaluate the links between survey variables, based on BIS+ and Blue targeting data, and water chemistry in 173 randomly selected headwater streams in the hemiboreal zone. While BIS+ and Blue targeting cannot replace more sophisticated monitoring methods necessary for classifying water quality in streams according to the EU Water Framework Directive (WFD, 2000/60/EC), our results lend support to the idea that the BIS+ protocol can be used to prioritise the protection of riparian forests. The relationship between BIS+ and water quality indicators (concentrations of nutrients and organic matter) together with data from fish studies suggests that this field protocol can be used to give reaches with higher biodiversity and conservation values a better protection. The tools indicate an ability to mitigate forestry impacts on water quality if the operations are adjusted to this knowledge in located areas.
- 1 March 2007
- Vol. 48 (3) , 413-9
PET imaging of regional 18F-FDG uptake and lung function after cigarette smoke inhalation.
Cigarette smoke is thought to promote local lung inflammation that leads to lung dysfunction. Lung neutrophilic inflammation is known to result in increased pulmonary uptake of (18)F-FDG. Using a sheep model of localized exposure to cigarette smoke, in this study we tested whether PET-imaged changes in regional intrapulmonary distribution of (18)F-FDG uptake are related to changes in regional lung function as assessed with the infused (13)NN-saline method. Five anesthetized, mechanically ventilated sheep were exposed to unilateral inhalation of smoke from 10 tobacco cigarettes while the contralateral lung was ventilated with smoke-free gas. Two hours after the exposure, regional gas content was measured from a transmission scan; regional ventilation, perfusion, and shunt were measured from the kinetics of (13)NN-saline; and regional (18)F-FDG influx constant (K(i)) was calculated with the Patlak algorithm applied at a voxel-by-voxel level. K(i) was higher and more heterogeneous in the smoke-exposed lungs than in the control lungs (P < 0.05). Spatial heterogeneity of K(i) and impairment in regional lung function were quite variable among animals despite similar levels of smoke exposure. However, increases in mean K(i) correlated linearly with its spatial heterogeneity (Spearman correlation, r(s) = 0.94), and the highest levels of regional K(i) in smoke-exposed lungs and control lungs correlated with regional shunt fraction (r(s) = 0.78). Also, the heterogeneity of the ventilation-perfusion (V/Q) distribution of the smoke-exposed lungs was 10 times greater than that of the control lungs but correlated strongly with that of the control lungs (r = 0.998). Substantial interanimal variability and spatial heterogeneity in lung function and (18)F-FDG uptake seem to characterize the response to smoke exposure. The highest levels of local (18)F-FDG uptake were associated with differences in V/Q matching and shunt fraction among animals. The data also suggest that preexisting heterogeneity in V/Q could have been responsible for the large interanimal variability by affecting the heterogeneity and strength of the acute response to smoke inhalation.
- 1 March 2007
- Vol. 48 (3) , 413-9
PET imaging of regional 18F-FDG uptake and lung function after cigarette smoke inhalation.
Cigarette smoke is thought to promote local lung inflammation that leads to lung dysfunction. Lung neutrophilic inflammation is known to result in increased pulmonary uptake of (18)F-FDG. Using a sheep model of localized exposure to cigarette smoke, in this study we tested whether PET-imaged changes in regional intrapulmonary distribution of (18)F-FDG uptake are related to changes in regional lung function as assessed with the infused (13)NN-saline method. Five anesthetized, mechanically ventilated sheep were exposed to unilateral inhalation of smoke from 10 tobacco cigarettes while the contralateral lung was ventilated with smoke-free gas. Two hours after the exposure, regional gas content was measured from a transmission scan; regional ventilation, perfusion, and shunt were measured from the kinetics of (13)NN-saline; and regional (18)F-FDG influx constant (K(i)) was calculated with the Patlak algorithm applied at a voxel-by-voxel level. K(i) was higher and more heterogeneous in the smoke-exposed lungs than in the control lungs (P < 0.05). Spatial heterogeneity of K(i) and impairment in regional lung function were quite variable among animals despite similar levels of smoke exposure. However, increases in mean K(i) correlated linearly with its spatial heterogeneity (Spearman correlation, r(s) = 0.94), and the highest levels of regional K(i) in smoke-exposed lungs and control lungs correlated with regional shunt fraction (r(s) = 0.78). Also, the heterogeneity of the ventilation-perfusion (V/Q) distribution of the smoke-exposed lungs was 10 times greater than that of the control lungs but correlated strongly with that of the control lungs (r = 0.998). Substantial interanimal variability and spatial heterogeneity in lung function and (18)F-FDG uptake seem to characterize the response to smoke exposure. The highest levels of local (18)F-FDG uptake were associated with differences in V/Q matching and shunt fraction among animals. The data also suggest that preexisting heterogeneity in V/Q could have been responsible for the large interanimal variability by affecting the heterogeneity and strength of the acute response to smoke inhalation.
- 1 August 2006
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 174 (3) , 245-253
Regional Pulmonary Perfusion, Inflation, and Ventilation Defects in Bronchoconstricted Patients with Asthma
Rationale: Bronchoconstriction in asthma leads to heterogeneous ventilation and the formation of large and contiguous ventilation defects in the lungs. However, the regional adaptations of pulmonary perfusion (Q̇) to such ventilation defects have not been well studied. Methods: We used positron emission tomography to assess the intrapulmonary kinetics of intravenously infused tracer nitrogen-13 (13NN), and measured the regional distributions of ventilation and perfusion in 11 patients with mild asthma. For each subject, the regional washout kinetics of 13NN before and during methacholine-induced bronchoconstriction were analyzed. Two regions of interest (ROIs) were defined: one over a spatially contiguous area of high tracer retention (TR) during bronchoconstriction and a second one covering an area of similar size, showing minimal tracer retention (NR). Results: Both ROIs demonstrated heterogeneous washout kinetics, which could be described by a two-compartment model with fast and slow washout rates. We found a systematic reduction in regional Q̇ to the TR ROI during bronchoconstriction and a variable and nonsignificant change in relative Q̇ for NR regions. The reduction in regional Q̇ was associated with an increase in regional gas content of the TR ROI, but its magnitude was greater than that anticipated solely by the change in regional lung inflation. Conclusion: During methacholine-induced bronchoconstriction, perfusion to ventilation defects are systematically reduced by a relative increase in regional pulmonary vascular resistance.
- 1 August 2006
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 174 (3) , 245-253
Regional Pulmonary Perfusion, Inflation, and Ventilation Defects in Bronchoconstricted Patients with Asthma
Rationale: Bronchoconstriction in asthma leads to heterogeneous ventilation and the formation of large and contiguous ventilation defects in the lungs. However, the regional adaptations of pulmonary perfusion (Q̇) to such ventilation defects have not been well studied. Methods: We used positron emission tomography to assess the intrapulmonary kinetics of intravenously infused tracer nitrogen-13 (13NN), and measured the regional distributions of ventilation and perfusion in 11 patients with mild asthma. For each subject, the regional washout kinetics of 13NN before and during methacholine-induced bronchoconstriction were analyzed. Two regions of interest (ROIs) were defined: one over a spatially contiguous area of high tracer retention (TR) during bronchoconstriction and a second one covering an area of similar size, showing minimal tracer retention (NR). Results: Both ROIs demonstrated heterogeneous washout kinetics, which could be described by a two-compartment model with fast and slow washout rates. We found a systematic reduction in regional Q̇ to the TR ROI during bronchoconstriction and a variable and nonsignificant change in relative Q̇ for NR regions. The reduction in regional Q̇ was associated with an increase in regional gas content of the TR ROI, but its magnitude was greater than that anticipated solely by the change in regional lung inflation. Conclusion: During methacholine-induced bronchoconstriction, perfusion to ventilation defects are systematically reduced by a relative increase in regional pulmonary vascular resistance.
- 1 January 2005
- Published by SAGE Publications in Respiratory Care
- Vol. 50 (1) , 78-99
Pressure-Volume Curves of the Respiratory System
The quasi-static pressure-volume (P-V) curve of the respiratory system describes the mechanical behavior of the lungs and chest wall during inflation and deflation. To eliminate resistive and convective acceleration effects, the measurement of volume and pressure must be performed during short periods of apnea or during very slow flow. There are 3 main techniques for acquiring quasi-static P-V curves: the supersyringe method, the constant flow method, and the multiple-occlusion (or ventilator) method. For the information to be interpreted correctly, one must understand the interaction between the lungs and the chest wall, the effects of the supine position, and the meaning of hysteresis. The P-V curve has been studied in many disease states, but it has been applied most extensively to patients with acute respiratory distress syndrome, in hopes that it might allow clinicians to customize ventilator settings according to a patient's individual respiratory mechanics and thus protect the patient from ventilator-induced lung injury. However, lack of standardization of the procedure used to acquire P-V curves, difficulties in measuring absolute lung volume, lack of knowledge regarding how to use the information, and a paucity of data showing a benefit in morbidity and mortality with the use of P-V curves have tempered early enthusiasm regarding the clinical usefulness of the quasi-static P-V curve.
- 1 January 2005
- Published by SAGE Publications in Respiratory Care
- Vol. 50 (1) , 78-99
Pressure-Volume Curves of the Respiratory System
The quasi-static pressure-volume (P-V) curve of the respiratory system describes the mechanical behavior of the lungs and chest wall during inflation and deflation. To eliminate resistive and convective acceleration effects, the measurement of volume and pressure must be performed during short periods of apnea or during very slow flow. There are 3 main techniques for acquiring quasi-static P-V curves: the supersyringe method, the constant flow method, and the multiple-occlusion (or ventilator) method. For the information to be interpreted correctly, one must understand the interaction between the lungs and the chest wall, the effects of the supine position, and the meaning of hysteresis. The P-V curve has been studied in many disease states, but it has been applied most extensively to patients with acute respiratory distress syndrome, in hopes that it might allow clinicians to customize ventilator settings according to a patient's individual respiratory mechanics and thus protect the patient from ventilator-induced lung injury. However, lack of standardization of the procedure used to acquire P-V curves, difficulties in measuring absolute lung volume, lack of knowledge regarding how to use the information, and a paucity of data showing a benefit in morbidity and mortality with the use of P-V curves have tempered early enthusiasm regarding the clinical usefulness of the quasi-static P-V curve.
- 1 December 2003
- Vol. 44 (12) , 1982-91
Quantification of regional ventilation-perfusion ratios with PET.
The topographic matching of alveolar ventilation (V(A)) and perfusion (Q) is the main determinant of gas exchange efficiency of the lung. However, no pulmonary functional imaging technique has been shown to predict whole-lung gas exchange in health and disease. This study aims to present a PET-based method to estimate regional alveolar ventilation-to-perfusion ratios (V(A)/Q) predictive of arterial blood gases. The method is based on the regional tracer kinetics of (13)N-nitrogen ((13)NN) after an intravenous bolus injection during a breath-hold period and subsequent washout from the lungs with resumption of breathing. The method takes into account the presence of inter- and intraregional nonuniformities at length scales smaller than the imaging spatial resolution. An algorithm used regional tracer washout to classify regional V(A)Q/ uniformity. Intraregional V(A)/Q mismatch in nonuniform regions was described with a 2-compartment model. Regional V(A)/Q estimates were combined into a whole-lung distribution of V(A)/Q ratios and were used to compute global arterial blood gases. The method was applied to 3-dimensional PET data from anesthetized and mechanically ventilated sheep before and after methacholine bronchoconstriction (n = 3) and pulmonary embolism (n = 3) and after saline lung lavage (n = 3). PET images revealed regional changes in ventilation and perfusion consistent with the different disease models. Quantification of the images using PET-derived V(A)Q/ distributions showed unimodal and narrow distributions in control conditions that became wider and unimodal after pulmonary embolism and saline lung lavage and bimodal after bronchoconstriction. Images of regional gas exchange allowed for visualization of regional gas exchange. Arterial blood gases estimated from the PET-based V(A)/Q distributions closely agreed with measured values (partial pressure of oxygen, arterial [PaO(2)]: r(2) = 0.97, P < 0.001; partial pressure of carbon dioxide, arterial [PaCO(2)]: r(2) = 0.96, P < 0.001). Tracer kinetics analysis of PET images after an intravenous injection of (13)NN provides a quantitative assessment of regional V(A)/Q heterogeneity including that corresponding to length scales smaller than the spatial resolution of the imaging method. Quantification of V(A)/Q mismatch obtained with the presented technique is directly related to severity of gas exchange impairment as determined by arterial blood gases.
- 1 December 2003
- Vol. 44 (12) , 1982-91
Quantification of regional ventilation-perfusion ratios with PET.
The topographic matching of alveolar ventilation (V(A)) and perfusion (Q) is the main determinant of gas exchange efficiency of the lung. However, no pulmonary functional imaging technique has been shown to predict whole-lung gas exchange in health and disease. This study aims to present a PET-based method to estimate regional alveolar ventilation-to-perfusion ratios (V(A)/Q) predictive of arterial blood gases. The method is based on the regional tracer kinetics of (13)N-nitrogen ((13)NN) after an intravenous bolus injection during a breath-hold period and subsequent washout from the lungs with resumption of breathing. The method takes into account the presence of inter- and intraregional nonuniformities at length scales smaller than the imaging spatial resolution. An algorithm used regional tracer washout to classify regional V(A)Q/ uniformity. Intraregional V(A)/Q mismatch in nonuniform regions was described with a 2-compartment model. Regional V(A)/Q estimates were combined into a whole-lung distribution of V(A)/Q ratios and were used to compute global arterial blood gases. The method was applied to 3-dimensional PET data from anesthetized and mechanically ventilated sheep before and after methacholine bronchoconstriction (n = 3) and pulmonary embolism (n = 3) and after saline lung lavage (n = 3). PET images revealed regional changes in ventilation and perfusion consistent with the different disease models. Quantification of the images using PET-derived V(A)Q/ distributions showed unimodal and narrow distributions in control conditions that became wider and unimodal after pulmonary embolism and saline lung lavage and bimodal after bronchoconstriction. Images of regional gas exchange allowed for visualization of regional gas exchange. Arterial blood gases estimated from the PET-based V(A)/Q distributions closely agreed with measured values (partial pressure of oxygen, arterial [PaO(2)]: r(2) = 0.97, P < 0.001; partial pressure of carbon dioxide, arterial [PaCO(2)]: r(2) = 0.96, P < 0.001). Tracer kinetics analysis of PET images after an intravenous injection of (13)NN provides a quantitative assessment of regional V(A)/Q heterogeneity including that corresponding to length scales smaller than the spatial resolution of the imaging method. Quantification of V(A)/Q mismatch obtained with the presented technique is directly related to severity of gas exchange impairment as determined by arterial blood gases.
- 1 January 2002
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 92 (1) , 297-312
Regional V˙a,Q˙, and V˙a/Q˙during PLV: effects of nitroprusside and inhaled nitric oxide
Partial liquid ventilation (PLV) with high-specific-weight perfluorocarbon liquids has been shown to improve oxygenation in acute lung injury, possibly by redistributing perfusion from dependent, injured regions to nondependent, less injured regions of the lung. Our hypothesis was that during PLV in normal lungs, a shift in perfusion away from dependent lung zones might, in part, be due to vasoconstriction that could be reversed by infusing sodium nitroprusside (NTP). In addition, delivering inhaled NO during PLV should improve gas exchange by further redistributing blood flow to well-ventilated lung regions. To examine this, we used a single transverse-slice positron emission tomography camera to image regional ventilation and perfusion at the level of the heart apex in six supine mechanically ventilated sheep during five conditions: control, PLV, PLV + NTP, and PLV + NO at 10 and 80 ppm. We found that PLV shifted perfusion from dependent to middle regions, and the dependent region demonstrated marked hypoventilation. The vertical distribution of perfusion changed little when high-dose intravenous NTP was added during PLV, and inhaled NO tended to shift perfusion toward better ventilated middle regions. We conclude that PLV shifts perfusion to the middle regions of the lung because of the high specific weight of perflubron rather than vasoconstriction.
- 1 January 2002
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 92 (1) , 297-312
Regional V˙a,Q˙, and V˙a/Q˙during PLV: effects of nitroprusside and inhaled nitric oxide
Partial liquid ventilation (PLV) with high-specific-weight perfluorocarbon liquids has been shown to improve oxygenation in acute lung injury, possibly by redistributing perfusion from dependent, injured regions to nondependent, less injured regions of the lung. Our hypothesis was that during PLV in normal lungs, a shift in perfusion away from dependent lung zones might, in part, be due to vasoconstriction that could be reversed by infusing sodium nitroprusside (NTP). In addition, delivering inhaled NO during PLV should improve gas exchange by further redistributing blood flow to well-ventilated lung regions. To examine this, we used a single transverse-slice positron emission tomography camera to image regional ventilation and perfusion at the level of the heart apex in six supine mechanically ventilated sheep during five conditions: control, PLV, PLV + NTP, and PLV + NO at 10 and 80 ppm. We found that PLV shifted perfusion from dependent to middle regions, and the dependent region demonstrated marked hypoventilation. The vertical distribution of perfusion changed little when high-dose intravenous NTP was added during PLV, and inhaled NO tended to shift perfusion toward better ventilated middle regions. We conclude that PLV shifts perfusion to the middle regions of the lung because of the high specific weight of perflubron rather than vasoconstriction.