Bernardo Dal Seno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bernardo Dal Seno has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Matteo Matteucci
IIT-Unit, Department of Electronics and Information, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
2 shared publicationsLuca Mainardi
IIT-Unit, Department of Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
1 shared publicationLuca T. Mainardi
Department of Bioengineering, IIT Unit, Politecnico di Milano, Milano, Italy
1 shared publication
Latest Publications
- Open Access
- 1 January 2010
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2010, 1-5
Online Detection of P300 and Error Potentials in a BCI Speller
Error potentials (ErrPs), that is, alterations of the EEG traces related to the subject perception of erroneous responses, have been suggested to be an elegant way to recognize misinterpreted commands in brain-computer interface (BCI) systems. We implemented a P300-based BCI speller that uses a genetic algorithm (GA) to detect P300s, and added an automatic error-correction system (ECS) based on the single-sweep detection of ErrPs. The developed system was tested on-line on three subjects and here we report preliminary results. In two out of three subjects, the GA provided a good performance in detecting P300 (90% and 60% accuracy with 5 repetitions), and it was possible to detect ErrP with an accuracy (roughly 60%) well above the chance level. In our knowledge, this is the first time that ErrP detection is performed on-line in a P300-based BCI. Preliminary results are encouraging, but further refinements are needed to improve performances.
- 1 January 2010
- Published by Wiley in Computational Intelligence and Neuroscience
- Vol. 2010, 1-5
Open AccessOnline Detection of P300 and Error Potentials in a BCI Speller
Error potentials (ErrPs), that is, alterations of the EEG traces related to the subject perception of erroneous responses, have been suggested to be an elegant way to recognize misinterpreted commands in brain-computer interface (BCI) systems. We implemented a P300-based BCI speller that uses a genetic algorithm (GA) to detect P300s, and added an automatic error-correction system (ECS) based on the single-sweep detection of ErrPs. The developed system was tested on-line on three subjects and here we report preliminary results. In two out of three subjects, the GA provided a good performance in detecting P300 (90% and 60% accuracy with 5 repetitions), and it was possible to detect ErrP with an accuracy (roughly 60%) well above the chance level. In our knowledge, this is the first time that ErrP detection is performed on-line in a P300-based BCI. Preliminary results are encouraging, but further refinements are needed to improve performances.
- 22 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 18 (1) , 20-28
The Utility Metric: A Novel Method to Assess the Overall Performance of Discrete Brain–Computer Interfaces
A relevant issue in a brain-computer interface (BCI) is the capability to efficiently convert user intentions into correct actions, and how to properly measure this efficiency. Usually, the evaluation of a BCI system is approached through the quantification of the classifier performance, which is often measured by means of the information transfer rate (ITR). A shortcoming of this approach is that the control interface design is neglected, and hence a poor description of the overall performance is obtained for real systems. To overcome this limitation, we propose a novel metric based on the computation of BCI Utility. The new metric can accurately predict the overall performance of a BCI system, as it takes into account both the classifier and the control interface characteristics. It is therefore suitable for design purposes, where we have to select the best options among different components and different parameters setup. In the paper, we compute Utility in two scenarios, a P300 speller and a P300 speller with an error correction system (ECS), for different values of accuracy of the classifier and recall of the ECS. Monte Carlo simulations confirm that Utility predicts the performance of a BCI better than ITR.
- 22 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 18 (1) , 20-28
The Utility Metric: A Novel Method to Assess the Overall Performance of Discrete Brain–Computer Interfaces
A relevant issue in a brain-computer interface (BCI) is the capability to efficiently convert user intentions into correct actions, and how to properly measure this efficiency. Usually, the evaluation of a BCI system is approached through the quantification of the classifier performance, which is often measured by means of the information transfer rate (ITR). A shortcoming of this approach is that the control interface design is neglected, and hence a poor description of the overall performance is obtained for real systems. To overcome this limitation, we propose a novel metric based on the computation of BCI Utility. The new metric can accurately predict the overall performance of a BCI system, as it takes into account both the classifier and the control interface characteristics. It is therefore suitable for design purposes, where we have to select the best options among different components and different parameters setup. In the paper, we compute Utility in two scenarios, a P300 speller and a P300 speller with an error correction system (ECS), for different values of accuracy of the classifier and recall of the ECS. Monte Carlo simulations confirm that Utility predicts the performance of a BCI better than ITR.