Elisa Beceiro-González
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elisa Beceiro-González has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Soledad Muniategui-Lorenzo
Group of Applied Analytical Chemistry (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Centro de Innovación Tecnolóxica en Edificación e Enxeñería Civil (CITEEC), Universidade da Coruña, 15071, A Coruña, Spain
5 shared publications - Maria Fátima Alpendurada
University of Porto
3 shared publications - María José González-Castro
Grupo Química Analítica Aplicada, Departamento de Química, Facultade de Ciencias, Instituto Universitario de Medio Ambiente, Universidade da Coruña, A Coruña, Spain
3 shared publications N. Rodríguez-González
Departamento de Química Analítica, Facultade de Ciencias, Universidade da Coruña, Grupo Química Analítica Aplicada (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Campus da Coruña, 15071, A Coruña, Spain
3 shared publicationsA. Guimaraes
2 shared publicationsM.J. González-Castro
Departamento de Química Analítica, Facultade de Ciencias, Universidade da Coruña, Grupo Química Analítica Aplicada (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Campus da Coruña, 15071, A Coruña, Spain
2 shared publications
Latest Publications
- Open Access
- 26 February 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (11) , 1603-1610
Development of a dispersive liquid–liquid microextraction method for the determination of plastic additives in seawater
A method using dispersive liquid–liquid microextraction (DLLME) prior to high performance liquid chromatography-diode array detection (HPLC-DAD) was developed to determine seven additives from the plastics industry (butylated hydroxytoluene, diisodecyl phthalate, irgafos 168, lawsone, quercetin, triclosan and vitamin E) in seawater samples. These compounds can reach seawater due to direct discharge from wastewater treatment plants and leaching from plastics and microplastics. The extraction was performed using 25 mL of seawater, 500 μL of 1-octanol (extraction solvent) and a stirring step instead of dispersive solvent. Additive concentrations were determined by LC-DAD on a C18 column with a mobile phase of acetonitrile and phosphoric acid aqueous solution (pH 3.5) by gradient elution. The analytical recoveries ranged from 82 to 93% for all compounds, except for lawsone (60%). Repeatability and intermediate precision were adequate with RSD < calculated values following the Horwitz equation at the concentration levels evaluated (0.06 and 0.24 mg L−1). All additives exhibited linear matrix calibration curves (R2 > 0.99). Detection limits ranged from 0.009 to 0.028 mg L−1 and quantification limits ranged from 0.027 to 0.084 mg L−1. Finally, the application of the method to real samples verified the method as accurate and applicable to seawater.
- 26 February 2024
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 16 (11) , 1603-1610
Open AccessDevelopment of a dispersive liquid–liquid microextraction method for the determination of plastic additives in seawater
A method using dispersive liquid–liquid microextraction (DLLME) prior to high performance liquid chromatography-diode array detection (HPLC-DAD) was developed to determine seven additives from the plastics industry (butylated hydroxytoluene, diisodecyl phthalate, irgafos 168, lawsone, quercetin, triclosan and vitamin E) in seawater samples. These compounds can reach seawater due to direct discharge from wastewater treatment plants and leaching from plastics and microplastics. The extraction was performed using 25 mL of seawater, 500 μL of 1-octanol (extraction solvent) and a stirring step instead of dispersive solvent. Additive concentrations were determined by LC-DAD on a C18 column with a mobile phase of acetonitrile and phosphoric acid aqueous solution (pH 3.5) by gradient elution. The analytical recoveries ranged from 82 to 93% for all compounds, except for lawsone (60%). Repeatability and intermediate precision were adequate with RSD < calculated values following the Horwitz equation at the concentration levels evaluated (0.06 and 0.24 mg L−1). All additives exhibited linear matrix calibration curves (R2 > 0.99). Detection limits ranged from 0.009 to 0.028 mg L−1 and quantification limits ranged from 0.027 to 0.084 mg L−1. Finally, the application of the method to real samples verified the method as accurate and applicable to seawater.
- 15 June 2020
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 105 (2) , 332-336
A Simple Method for the Determination of Triazines from Seawater in Accordance with the Directive 2013/39/EU
Since the Directive 2013/39/EU included terbutryn to the list of priority substances of all water bodies, a previous method based on dispersive liquid–liquid micro-extraction (DLLME) for the determination of triazines in seawater has been modified. The main change consisted on the use of tandem mass spectrometry instead of diode array as detection technique. Due to the higher sensitivity of mass detector, sample volume was reduced and extraction solvent volume was optimized. The optimum extraction conditions were 5 mL of sample, 50 µL of 1-octanol and an agitation step instead of disperser solvent. The obtained analytical recoveries (73%–101% with relative standard deviations below 4%) meeting the requirements. The limits of quantification (between 0.016 and 0.021 µg L−1) were more than 10 times lower than the limit set by the European Directive 2013/39/EU for terbutryn (0.34 µg L−1). The proposed method was applied to the determination of the target compounds in seawater samples from A Coruña (Galicia, NW of Spain).
- 15 June 2020
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 105 (2) , 332-336
A Simple Method for the Determination of Triazines from Seawater in Accordance with the Directive 2013/39/EU
Since the Directive 2013/39/EU included terbutryn to the list of priority substances of all water bodies, a previous method based on dispersive liquid–liquid micro-extraction (DLLME) for the determination of triazines in seawater has been modified. The main change consisted on the use of tandem mass spectrometry instead of diode array as detection technique. Due to the higher sensitivity of mass detector, sample volume was reduced and extraction solvent volume was optimized. The optimum extraction conditions were 5 mL of sample, 50 µL of 1-octanol and an agitation step instead of disperser solvent. The obtained analytical recoveries (73%–101% with relative standard deviations below 4%) meeting the requirements. The limits of quantification (between 0.016 and 0.021 µg L−1) were more than 10 times lower than the limit set by the European Directive 2013/39/EU for terbutryn (0.34 µg L−1). The proposed method was applied to the determination of the target compounds in seawater samples from A Coruña (Galicia, NW of Spain).
- 27 January 2017
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (8) , 7764-7775
Reliable methods for determination of triazine herbicides and their degradation products in seawater and marine sediments using liquid chromatography-tandem mass spectrometry
Triazines and their degradation products are transported to the aquatic environment, and once there, the probability to reach the marine environment is very high. In this paper, solid phase extraction (SPE) and extraction by matrix solid phase dispersion (MSPD) to analyse nine triazines (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine and terbutryn) and eight degradation products (desethylatrazine, desethyldesisopropylatrazine, desethyl-2-hydroxyatrazine, desethylterbuthylazine, desisopropylatrazine, desisopropyl-2-hydroxyatrazine, 2-hydroxyatrazine and 2-hidroxyterbuthylazine) in seawater and marine sediments samples were used. The analysis was carried out using liquid chromatography with tandem mass spectrometry (LC-ESI-MS/MS). The methods were optimized and validated to achieve a selective and sensitive determination of the analytes from different sample, regardless of its complexity. Under the optimum conditions, the proposed methods provided adequate limits of quantification (0.05–0.45 μg L−1 and 0.23–4.26 μg kg−1 in seawater and marine sediments, respectively). Intra- and inter-day relative standard deviation were below 1.41% for all compounds. Recoveries were evaluated, and acceptable values that ranged from 87.5–99.4 and 60.9–99.7% for the seawater and sediment samples, respectively, were obtained. The proposed methods were applied to the analysis of the target compounds in seawater samples and marine sediments from a coastal area of Galicia (NW of Spain).
- 27 January 2017
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 24 (8) , 7764-7775
Reliable methods for determination of triazine herbicides and their degradation products in seawater and marine sediments using liquid chromatography-tandem mass spectrometry
Triazines and their degradation products are transported to the aquatic environment, and once there, the probability to reach the marine environment is very high. In this paper, solid phase extraction (SPE) and extraction by matrix solid phase dispersion (MSPD) to analyse nine triazines (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine and terbutryn) and eight degradation products (desethylatrazine, desethyldesisopropylatrazine, desethyl-2-hydroxyatrazine, desethylterbuthylazine, desisopropylatrazine, desisopropyl-2-hydroxyatrazine, 2-hydroxyatrazine and 2-hidroxyterbuthylazine) in seawater and marine sediments samples were used. The analysis was carried out using liquid chromatography with tandem mass spectrometry (LC-ESI-MS/MS). The methods were optimized and validated to achieve a selective and sensitive determination of the analytes from different sample, regardless of its complexity. Under the optimum conditions, the proposed methods provided adequate limits of quantification (0.05–0.45 μg L−1 and 0.23–4.26 μg kg−1 in seawater and marine sediments, respectively). Intra- and inter-day relative standard deviation were below 1.41% for all compounds. Recoveries were evaluated, and acceptable values that ranged from 87.5–99.4 and 60.9–99.7% for the seawater and sediment samples, respectively, were obtained. The proposed methods were applied to the analysis of the target compounds in seawater samples and marine sediments from a coastal area of Galicia (NW of Spain).
- 7 August 2014
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 22 (1) , 618-626
An environmentally friendly method for the determination of triazine herbicides in estuarine seawater samples by dispersive liquid–liquid microextraction
A fast, simple, sensitive and green chemistry method using dispersive liquid–liquid microextraction (DLLME) for the simultaneous determination of seven triazine herbicides (ametryn, atrazine, cyanazine, propazine, simazine, simetryn and terbuthylazine) in estuarine seawater samples has been developed. DLLME was carried out using a small volume of seawater (25 mL) and 300 μL of 1-octanol. Herbicide concentrations were determined by liquid chromatography-diode array detection, and results were confirmed by liquid chromatography-electrospray ionisation tandem spectrometry analysis. The analytical features of the proposed method were satisfactory with repeatability < ±5 % and intermediate precision < ±10 %, and recoveries ranged from 81–102 % for all compounds. All the triazines exhibited linear matrix calibration curves with coefficients of determination >0.999 for all the analytes except for simazine (0.9975). Limits of quantification ranged between 0.19 and 1.12 μg L−1. The method was applied to the analysis of seawater samples from ten points susceptible to contamination by triazines from estuary of A Coruña (Galicia, NW of Spain). The levels of the seven triazines were below the LODs in the analysed samples. Use of proposed method will allow for monitoring of triazines at levels below the regulatory limits set by the European Directive 2008/105/EC of 2 and 4 μg L−1 for atrazine and simazine, respectively.
- 7 August 2014
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 22 (1) , 618-626
An environmentally friendly method for the determination of triazine herbicides in estuarine seawater samples by dispersive liquid–liquid microextraction
A fast, simple, sensitive and green chemistry method using dispersive liquid–liquid microextraction (DLLME) for the simultaneous determination of seven triazine herbicides (ametryn, atrazine, cyanazine, propazine, simazine, simetryn and terbuthylazine) in estuarine seawater samples has been developed. DLLME was carried out using a small volume of seawater (25 mL) and 300 μL of 1-octanol. Herbicide concentrations were determined by liquid chromatography-diode array detection, and results were confirmed by liquid chromatography-electrospray ionisation tandem spectrometry analysis. The analytical features of the proposed method were satisfactory with repeatability < ±5 % and intermediate precision < ±10 %, and recoveries ranged from 81–102 % for all compounds. All the triazines exhibited linear matrix calibration curves with coefficients of determination >0.999 for all the analytes except for simazine (0.9975). Limits of quantification ranged between 0.19 and 1.12 μg L−1. The method was applied to the analysis of seawater samples from ten points susceptible to contamination by triazines from estuary of A Coruña (Galicia, NW of Spain). The levels of the seven triazines were below the LODs in the analysed samples. Use of proposed method will allow for monitoring of triazines at levels below the regulatory limits set by the European Directive 2008/105/EC of 2 and 4 μg L−1 for atrazine and simazine, respectively.
- Open Access
- 18 June 2014
- Published by Taylor & Francis in Green Chemistry Letters and Reviews
- Vol. 7 (3) , 271-277
A simple method for simultaneous determination of nine triazines in drinking water
A simple, effective, and economic method for determination of nine triazines (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine, and terbutryn) in drinking water based on solid-phase extraction (SPE) followed by high-performance liquid chromatography-diode array detection (HPLC-DAD) was developed. A specialized solid phase (Oasis HLB) was used, and the parameters that may affect the efficiency of SPE were optimized. The limits of detection (ranged from 0.010 to 0.023 µg L−1) were satisfactory and allow the determination of triazines at the levels required by European Union legislation. Repeatability (2.4–7.6%) and intermediate precision (0.9–11.0%) calculated at 0.1 µg L−1 (legislation level) were adequate. The accuracy calculated as the average recovery of spiked tap and mineral waters was higher than 86% for all compounds. The developed method also could be used for undergraduate laboratory experiments because it acquaints students with solution preparation, solid phase extraction procedure, and HPLC-DAD technique.
- 18 June 2014
- Published by Taylor & Francis in Green Chemistry Letters and Reviews
- Vol. 7 (3) , 271-277
Open AccessA simple method for simultaneous determination of nine triazines in drinking water
A simple, effective, and economic method for determination of nine triazines (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine, and terbutryn) in drinking water based on solid-phase extraction (SPE) followed by high-performance liquid chromatography-diode array detection (HPLC-DAD) was developed. A specialized solid phase (Oasis HLB) was used, and the parameters that may affect the efficiency of SPE were optimized. The limits of detection (ranged from 0.010 to 0.023 µg L−1) were satisfactory and allow the determination of triazines at the levels required by European Union legislation. Repeatability (2.4–7.6%) and intermediate precision (0.9–11.0%) calculated at 0.1 µg L−1 (legislation level) were adequate. The accuracy calculated as the average recovery of spiked tap and mineral waters was higher than 86% for all compounds. The developed method also could be used for undergraduate laboratory experiments because it acquaints students with solution preparation, solid phase extraction procedure, and HPLC-DAD technique.
- Open Access
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 536369
Application of a Developed Method for the Extraction of Triazines in Surface Waters and Storage Prior to Analysis to Seawaters of Galicia (Northwest Spain)
A simple method based on solid‐phase extraction combined with liquid chromatography for simultaneous determination of nine triazine herbicides (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine, and terbutryn) in surface water samples was developed and validated. Under optimized conditions, 50 mL of water sample was pumped through the Oasis HLB cartridge, and triazines were eluted with 3 mL acetone. Finally the extract was concentrated to dryness, reconstituted with 1 mL methanol : water (1 : 1) and injected into the HPLC‐DAD system. The stability of the herbicides on the cartridges at −18 and 4°C was also evaluated, and the recoveries obtained after three weeks of storage were satisfactory for all compounds. The analytical features of the proposed method were satisfactory: repeatability and intermediate precision were −1) were adequately allowing the determination of these compounds at the levels requested by the 2008/105/EC Directive. Finally, this method was applied to the analysis of 50 seawater samples from Galicia (northwest Spain).
- 1 January 2013
- Published by Wiley in The Scientific World Journal
- Vol. 2013 (1) , 536369
Open AccessApplication of a Developed Method for the Extraction of Triazines in Surface Waters and Storage Prior to Analysis to Seawaters of Galicia (Northwest Spain)
A simple method based on solid‐phase extraction combined with liquid chromatography for simultaneous determination of nine triazine herbicides (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine, and terbutryn) in surface water samples was developed and validated. Under optimized conditions, 50 mL of water sample was pumped through the Oasis HLB cartridge, and triazines were eluted with 3 mL acetone. Finally the extract was concentrated to dryness, reconstituted with 1 mL methanol : water (1 : 1) and injected into the HPLC‐DAD system. The stability of the herbicides on the cartridges at −18 and 4°C was also evaluated, and the recoveries obtained after three weeks of storage were satisfactory for all compounds. The analytical features of the proposed method were satisfactory: repeatability and intermediate precision were −1) were adequately allowing the determination of these compounds at the levels requested by the 2008/105/EC Directive. Finally, this method was applied to the analysis of 50 seawater samples from Galicia (northwest Spain).
- 1 February 2007
- Published by Elsevier in Journal of Chromatography A
- Vol. 1141 (2) , 165-173
Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography–mass spectrometry
- 1 February 2007
- Published by Elsevier in Journal of Chromatography A
- Vol. 1141 (2) , 165-173
Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography–mass spectrometry