Nicolas Zouain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nicolas Zouain has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Justin Hayes
MeritCare Roger Maris Cancer Center, Fargo, N. Dak., USA
1 shared publicationM. McCurdy
Department of Medicine, University of North Dakota School of Medicine and Health Sciences, Fargo, N. Dak., USA
1 shared publicationMatt McCurdy
University of North Dakota School of Medicine and Health Sciences, Fargo, N. Dak., USA
1 shared publication- Mohammed Najeeb Al Hallak
University of North Dakota School of Medicine and Health Sciences, Fargo, N. Dak., USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2009
- Published by S. Karger AG in Case Reports in Oncology
- Vol. 2 (2) , 157-161
The Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
153Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. 153Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of 153Sm-EDTMP leads to contamination with 154Eu (Europium-154) [2]. A previous study only alluded to the retention of 154Eu in the bones after receiving treatment with 153Sm-EDTMP [2]. Activation of the alarm at security checkpoints after 153Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received 153Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing theAmerican-Canadian border. We assume that the 154Eu which remained in the patients’ bones activated the sensors. Methods: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received 153Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. Results: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of 154Eu emissions. Conclusion: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of 154Eu retained in patients who received 153Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of 153Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with 153Sm-EDTMP at Roger Maris Cancer Center receive laminated cards stating the date and the dose of treatment, as well as a statement that the holder may activate the alarm at the security checkpoints.
- 1 January 2009
- Published by S. Karger AG in Case Reports in Oncology
- Vol. 2 (2) , 157-161
Open AccessThe Level of Europium-154 Contaminating Samarium-153-EDTMP Activates the Radiation Alarm System at the US Homeland Security Checkpoints
153Sm-EDTMP is a radiopharmaceutical composed of EDTMP (ethylenediamine-tetramethylenephosphonate) and Samarium-153 [1]. 153Sm-EDTMP has an affinity for skeletal tissue and concentrates in areas with increased bone turnover; thus, it is successfully used in relieving pain related to diffuse bone metastases [1]. The manufacturing process of 153Sm-EDTMP leads to contamination with 154Eu (Europium-154) [2]. A previous study only alluded to the retention of 154Eu in the bones after receiving treatment with 153Sm-EDTMP [2]. Activation of the alarm at security checkpoints after 153Sm-EDTMP therapy has not been previously reported. Two out of 15 patients who received 153Sm-EDTMP at Roger Maris Cancer Center (Fargo, N. Dak., USA) activated the radiation activity sensors while passing through checkpoints; one at a US airport and the other while crossing theAmerican-Canadian border. We assume that the 154Eu which remained in the patients’ bones activated the sensors. Methods: In order to investigate this hypothesis, we obtained the consent from 3 of our 15 patients who received 153Sm-EDTMP within the previous 4 months to 2 years, including the patient who had activated the radiation alarm at the airport. The patients were scanned with a handheld detector and a gamma camera for energies from 511 keV to 1.3 MeV. Results: All three patients exhibited identical spectral images, and further analysis showed that the observed spectra are the result of 154Eu emissions. Conclusion: Depending on the detection thresholds and windows used by local and federal authorities, the remaining activity of 154Eu retained in patients who received 153Sm-EDTMP could be sufficient enough to increase the count rates above background levels and activate the sensors. At Roger Maris Cancer Center, patients are now informed of the potential consequences of 153Sm-EDTMP therapy prior to initiating treatment. In addition, patients treated with 153Sm-EDTMP at Roger Maris Cancer Center receive laminated cards stating the date and the dose of treatment, as well as a statement that the holder may activate the alarm at the security checkpoints.
- Open Access
- 1 January 2009
- Published by S. Karger AG in Case Reports in Oncology
- Vol. 2 (2) , 97-102
Successful Treatment of Primary Vaginal Papillary Serous Adenocarcinoma Using Chemoradiation Followed by Brachytherapy
Advances in treatment have not recently been reported in rare primary vaginal adenocarcinomas. A 56-year-old woman with a chronic vaginal cyst and possible in utero diethylstilbestrol exposure presented with postmenopausal bleeding. Biopsy of the vagina revealed high-grade papillary serous adenocarcinoma. MRI showed a 6-cm vaginal tumor and 3-cm left inguinal lymph node with metastasis. The patient initially received concurrent cisplatin and radiation. She then received high-dose-rate brachytherapy for further local control. Brachytherapy following external beam radiation with concurrent cisplatin led to clinically undetectable cancer at 24 months with minimal side effects.
- 1 January 2009
- Published by S. Karger AG in Case Reports in Oncology
- Vol. 2 (2) , 97-102
Open AccessSuccessful Treatment of Primary Vaginal Papillary Serous Adenocarcinoma Using Chemoradiation Followed by Brachytherapy
Advances in treatment have not recently been reported in rare primary vaginal adenocarcinomas. A 56-year-old woman with a chronic vaginal cyst and possible in utero diethylstilbestrol exposure presented with postmenopausal bleeding. Biopsy of the vagina revealed high-grade papillary serous adenocarcinoma. MRI showed a 6-cm vaginal tumor and 3-cm left inguinal lymph node with metastasis. The patient initially received concurrent cisplatin and radiation. She then received high-dose-rate brachytherapy for further local control. Brachytherapy following external beam radiation with concurrent cisplatin led to clinically undetectable cancer at 24 months with minimal side effects.