Gonzalo Muñoz
Research Subjects
Research Interests
Gonzalo Muñoz has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
César Albarrán-Diego
13 shared publicationsTeresa Ferrer-Blasco
8 shared publicationsHani F. Sakla
From the Ebsaar Eye Surgery Center (Muñoz, Sakla, Altroudi), Dubai, United Arab Emirates, and Clínica Baviera Castellón (Muñoz, Rohrweck), Castellón, Spain
6 shared publicationsJaime Javaloy
University Miguel Hernandez, Elche, Alicante, Spain
5 shared publicationsSantiago García-Lázaro
Univ Valencia, Dept Opt, Optometry Res Grp, Valencia, Spain
4 shared publicationsJorge L. Alió
From the Refractive Surgery Department, Hospital NISA Virgen del Consuelo (Muñoz, Albarrán-Diego), Valencia, and the Refractive Surgery Department, Vissum Instituto Oftalmológico de Alicante (Muñoz, Sakla, Pérez-Santonja, Alió), Alicante, Spain
3 shared publications
Latest Publications
- 1 March 2015
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (3) , 487-491
Pinhole iris-fixated intraocular lens for dysphotopsia and photophobia
We present the pinhole iris-fixated diaphragm intraocular lens (IOL), which is a 1-piece black polycarbonate IOL with rigid iris-fixated haptics, an 8.5 mm overall length, a 6.0 mm diameter optic, and a central opening, the pinhole. The IOL was implanted in a 36-year-old man who had a history of debilitating dysphotopsia (star burst, halos, glare, and ghosting) and severe light sensitivity in his right eye following several interventions for keratoconus. The diameter of the central opening of the pinhole IOL, 2.0 mm, was based on the patient's corneal aberration profile. Postoperatively, the dysphotopic symptoms and photophobia markedly improved. We recommend the use of the pinhole iris-fixated IOL in patients with severe photophobia or dysphotopsia refractory to other treatment modalities. No author has a financial or proprietary interest in any material or method mentioned.
- 1 March 2015
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (3) , 487-491
Pinhole iris-fixated intraocular lens for dysphotopsia and photophobia
We present the pinhole iris-fixated diaphragm intraocular lens (IOL), which is a 1-piece black polycarbonate IOL with rigid iris-fixated haptics, an 8.5 mm overall length, a 6.0 mm diameter optic, and a central opening, the pinhole. The IOL was implanted in a 36-year-old man who had a history of debilitating dysphotopsia (star burst, halos, glare, and ghosting) and severe light sensitivity in his right eye following several interventions for keratoconus. The diameter of the central opening of the pinhole IOL, 2.0 mm, was based on the patient's corneal aberration profile. Postoperatively, the dysphotopic symptoms and photophobia markedly improved. We recommend the use of the pinhole iris-fixated IOL in patients with severe photophobia or dysphotopsia refractory to other treatment modalities. No author has a financial or proprietary interest in any material or method mentioned.
- 1 July 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (7) , 1166-1175
Iris-fixated toric phakic intraocular lens for myopic astigmatism
To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Private practice surgery centers, Valencia and Terrassa, Spain. Cohort study. At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from -8.85 diopters (D) ± 2.71 (SD) to -0.37 ± 0.46 D, with 66.7% of the eyes within ± 0.50 D. The mean cylinder power decreased from -2.90 D (range -1.50 to -5.00 D) to -0.39 D (range 0.00 to -1.50 D); refraction was highly stable. All eyes achieved a decimal UDVA of 0.5 or better and a CDVA of 0.8 or better. A gain of 1 line or more of CDVA was found in 69.1% of eyes. The mean clinical pIOL misalignment was 2.6 ± 1.8 degrees; 1 eye (2.4%) required surgical repositioning of the pIOL. The mean ECC decrease was 9.3% ± 1.8%; iris pigment precipitates were observed in 16.7% of eyes. Vector analysis showed excellent mean indices of success for overall (0.94 ± 0.04), spherical (0.96 ± 0.05), and astigmatic (0.95 ± 0.16) corrections; the mean angle of error was 1.8 ± 2.7 degrees. Implantation of the toric pIOL was effective, predictable, safe, and stable for the correction of myopic astigmatism. No author has a financial or proprietary interest in any material or method mentioned.
- 1 July 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (7) , 1166-1175
Iris-fixated toric phakic intraocular lens for myopic astigmatism
To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Private practice surgery centers, Valencia and Terrassa, Spain. Cohort study. At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from -8.85 diopters (D) ± 2.71 (SD) to -0.37 ± 0.46 D, with 66.7% of the eyes within ± 0.50 D. The mean cylinder power decreased from -2.90 D (range -1.50 to -5.00 D) to -0.39 D (range 0.00 to -1.50 D); refraction was highly stable. All eyes achieved a decimal UDVA of 0.5 or better and a CDVA of 0.8 or better. A gain of 1 line or more of CDVA was found in 69.1% of eyes. The mean clinical pIOL misalignment was 2.6 ± 1.8 degrees; 1 eye (2.4%) required surgical repositioning of the pIOL. The mean ECC decrease was 9.3% ± 1.8%; iris pigment precipitates were observed in 16.7% of eyes. Vector analysis showed excellent mean indices of success for overall (0.94 ± 0.04), spherical (0.96 ± 0.05), and astigmatic (0.95 ± 0.16) corrections; the mean angle of error was 1.8 ± 2.7 degrees. Implantation of the toric pIOL was effective, predictable, safe, and stable for the correction of myopic astigmatism. No author has a financial or proprietary interest in any material or method mentioned.
- 16 March 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (6) , e488-e489
Cataract surgery in West Africa: is couching still a choice?
- 16 March 2012
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (6) , e488-e489
Cataract surgery in West Africa: is couching still a choice?
- 1 January 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (1) , 8-15
Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes
PURPOSE: To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. SETTING: Private refractive surgery center, Valencia, Spain. DESIGN: Cohort study. METHODS: After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pupils. RESULTS: The study enrolled 42 eyes (21 patients). Twelve months postoperatively, there were no statistically significant differences in any parameter studied including residual spherical equivalent (mean -0.05 diopter [D] +/- 0.25 [SD] single pass; -0.03 +/- 0.19 D double pass; P=.75), UDVA (mean 0.008 +/- 0.057 logMAR single pass; 0.011 +/- 0.046 logMAR double pass; P=.89), CDVA (mean -0.010 +/- 0.040 logMAR single pass; -0.007 +/- 0.037 logMAR double pass; P=.74), or anterior corneal HOAs. No eye lost 1 line of CDVA. CONCLUSIONS: Visual acuity, refractive outcomes, and anterior corneal HOAs were comparable between eyes after uneventful femtosecond laser single pass or double pass after suction loss affecting the pupillary area. A new femtosecond laser pass performed immediately after incomplete flap due to intraoperative suction loss provided good visual and optical outcomes.
- 1 January 2012
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (1) , 8-15
Single versus double femtosecond laser pass for incomplete laser in situ keratomileusis flap in contralateral eyes: Visual and optical outcomes
PURPOSE: To evaluate visual acuity, refractive outcomes, and anterior corneal higher-order aberrations (HOAs) after myopic laser in situ keratomileusis (LASIK) with uneventful single femtosecond laser pass versus double pass performed for intraoperative suction loss. SETTING: Private refractive surgery center, Valencia, Spain. DESIGN: Cohort study. METHODS: After the LASIK flap was created with a single pass of an Intralase femtosecond laser in 1 eye and a double pass in the fellow eye, the ablation was performed with a Visx S2 laser. At 12 months, the refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, and anterior corneal HOAs were measured with 4.0 mm and 6.0 mm pupils. RESULTS: The study enrolled 42 eyes (21 patients). Twelve months postoperatively, there were no statistically significant differences in any parameter studied including residual spherical equivalent (mean -0.05 diopter [D] +/- 0.25 [SD] single pass; -0.03 +/- 0.19 D double pass; P=.75), UDVA (mean 0.008 +/- 0.057 logMAR single pass; 0.011 +/- 0.046 logMAR double pass; P=.89), CDVA (mean -0.010 +/- 0.040 logMAR single pass; -0.007 +/- 0.037 logMAR double pass; P=.74), or anterior corneal HOAs. No eye lost 1 line of CDVA. CONCLUSIONS: Visual acuity, refractive outcomes, and anterior corneal HOAs were comparable between eyes after uneventful femtosecond laser single pass or double pass after suction loss affecting the pupillary area. A new femtosecond laser pass performed immediately after incomplete flap due to intraoperative suction loss provided good visual and optical outcomes.
- 2 November 2011
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 21 (6) , 723-731
Lack of Effect of Intraocular Lens Asphericity on Visual Performance with Acrylic Intraocular Lenses
Purpose.: To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods.: In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results.: Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and greater Strehl ratio after surgery, showing a better optical quality in comparison with the standard spherical IOL. However, visual acuity and both mesopic and photopic contrast sensitivity were not significantly different between the groups. Conclusions.: The significantly better optical quality achieved with the aspheric acrylic IOL design did not result in improved visual acuity or contrast sensitivity in comparison with a conventional spherical acrylic IOL.
- 2 November 2011
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 21 (6) , 723-731
Lack of Effect of Intraocular Lens Asphericity on Visual Performance with Acrylic Intraocular Lenses
Purpose.: To determine whether implantation of acrylic intraocular lens (IOL) with aspheric design (Tecnis Z9003, AMO) results in improved visual acuity or contrast sensitivity compared with conventional spherical acrylic IOL (AR40e, AMO). Methods.: In an intraindividual randomized prospective study of 60 patients with bilateral cataract, the Tecnis Z9003 IOL was compared with the AR40e IOL. Ocular aberrations for a 4.0-mm pupil and 6.0-mm pupil were measured with a Hartmann-Shack aberrometer. Quality of vision was measured using visual acuity and contrast sensitivity under mesopic and photopic conditions. Results.: Eyes with the Tecnis Z9003 IOL had significantly less spherical aberration and greater Strehl ratio after surgery, showing a better optical quality in comparison with the standard spherical IOL. However, visual acuity and both mesopic and photopic contrast sensitivity were not significantly different between the groups. Conclusions.: The significantly better optical quality achieved with the aspheric acrylic IOL design did not result in improved visual acuity or contrast sensitivity in comparison with a conventional spherical acrylic IOL.
- 1 November 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (11) , 2043-2052
Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens
To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Private practice surgery center, Valencia, Spain. Cohort study. Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. In the multifocal group, the mean binocular corrected distance visual acuity (logMAR) was -0.04 ± 0.07 at 6 m, 0.11 ± 0.10 at 1 m, and 0.06 ± 0.07 at 40 cm. The defocus curve showed little intermediate vision drop off. Photopic contrast sensitivity for distance was similar to the monofocal IOL contrast sensitivity function, while photopic contrast sensitivity for near and mesopic contrast sensitivity for distance with or without glare was reduced at high frequencies. The mean patient satisfaction was 8.09 ± 1.30 (scale 0 to 10); 84.4% of patients were completely independent of spectacles. Moderate halos, glare, and night-vision problems were reported by 6.2%, 12.5%, and 15.6% of patients, respectively. The new-generation multifocal IOL provided adequate distance, intermediate, and, to a lesser extent, near vision with high rates of spectacle freedom. Halos occurred, and other photic phenomena should be expected in a small percentage of patients. No author has a financial or proprietary interest in any material or method mentioned.
- 1 November 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (11) , 2043-2052
Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens
To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Private practice surgery center, Valencia, Spain. Cohort study. Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. In the multifocal group, the mean binocular corrected distance visual acuity (logMAR) was -0.04 ± 0.07 at 6 m, 0.11 ± 0.10 at 1 m, and 0.06 ± 0.07 at 40 cm. The defocus curve showed little intermediate vision drop off. Photopic contrast sensitivity for distance was similar to the monofocal IOL contrast sensitivity function, while photopic contrast sensitivity for near and mesopic contrast sensitivity for distance with or without glare was reduced at high frequencies. The mean patient satisfaction was 8.09 ± 1.30 (scale 0 to 10); 84.4% of patients were completely independent of spectacles. Moderate halos, glare, and night-vision problems were reported by 6.2%, 12.5%, and 15.6% of patients, respectively. The new-generation multifocal IOL provided adequate distance, intermediate, and, to a lesser extent, near vision with high rates of spectacle freedom. Halos occurred, and other photic phenomena should be expected in a small percentage of patients. No author has a financial or proprietary interest in any material or method mentioned.
- 1 November 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (11) , 804-810
Refractive Outcomes and Quality of Vision Related to an Outbreak of Diffuse Lamellar Keratitis
Purpose: To report the impact on visual function and corneal aberrations during an epidemic of diffuse lamellar keratitis (DLK). Methods: A retrospective, comparative, and consecutive case-control study was performed, involving 418 eyes operated between March and October 2007 in the refractive surgery unit of one center. Eyes were separated into groups: group 1 (DLK group) included 209 eyes that presented with DLK after LASIK and group 2 (control group) included 209 unaffected, consecutive eyes operated from the beginning of the outbreak. Refractive variables and corneal aberrations were compared between the two groups. Results: Visual outcomes were significantly different when comparing control eyes and eyes with DLK grades 3 and 4, but not for eyes with DLK grades 1 and 2. Uncorrected distance visual acuity (UDVA) significantly improved from the third month after DLK was diagnosed (Kruskal-Wallis, P =.02). Corrected distance visual acuity (CDVA) did not decrease significantly with DLK grades 1 and 2 (preoperative CDVA vs 1, 3, and 6 months after diagnosis; Mann-Whitney, P >.05, respectively). At the end of follow-up, UDVA and CDVA were not significantly different between the two groups. Eyes suffering from DLK had significantly increased corneal aberrations, except for spherical and astigmatism aberrations, 3 months after being diagnosed (Kruskal-Wallis, P <.05); however, corneal aberrations were not significantly different between the DLK and control groups (Mann-Whitney, P >.05). Conclusions: The outbreak of DLK did not induce a significant decrease in global visual outcomes, except in severe cases, and postoperative corneal aberrations were not affected.
- 1 November 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (11) , 804-810
Refractive Outcomes and Quality of Vision Related to an Outbreak of Diffuse Lamellar Keratitis
Purpose: To report the impact on visual function and corneal aberrations during an epidemic of diffuse lamellar keratitis (DLK). Methods: A retrospective, comparative, and consecutive case-control study was performed, involving 418 eyes operated between March and October 2007 in the refractive surgery unit of one center. Eyes were separated into groups: group 1 (DLK group) included 209 eyes that presented with DLK after LASIK and group 2 (control group) included 209 unaffected, consecutive eyes operated from the beginning of the outbreak. Refractive variables and corneal aberrations were compared between the two groups. Results: Visual outcomes were significantly different when comparing control eyes and eyes with DLK grades 3 and 4, but not for eyes with DLK grades 1 and 2. Uncorrected distance visual acuity (UDVA) significantly improved from the third month after DLK was diagnosed (Kruskal-Wallis, P =.02). Corrected distance visual acuity (CDVA) did not decrease significantly with DLK grades 1 and 2 (preoperative CDVA vs 1, 3, and 6 months after diagnosis; Mann-Whitney, P >.05, respectively). At the end of follow-up, UDVA and CDVA were not significantly different between the two groups. Eyes suffering from DLK had significantly increased corneal aberrations, except for spherical and astigmatism aberrations, 3 months after being diagnosed (Kruskal-Wallis, P <.05); however, corneal aberrations were not significantly different between the DLK and control groups (Mann-Whitney, P >.05). Conclusions: The outbreak of DLK did not induce a significant decrease in global visual outcomes, except in severe cases, and postoperative corneal aberrations were not affected.
- 1 September 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (9) , 672-677
Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser
PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens group, mean endothelial cell density improved significantly from 3401±292 cells/mm 2 to 3587±262 cells/mm 2 ( P <.001) with a mean increase of 5.5%. The percentage of hexagonal cells was statistically significantly higher after surgery (32.5±4.0%) compared with preoperative data (31.0±5.1%) ( P =.035). No statistically significant differences were noted regarding mean endothelial cell density ( P =.126) or hexagonality ( P =.56) before and 1 year after femtosecond LASIK in the non-contact lens group. CONCLUSIONS: Femtosecond LASIK to correct myopia was safe for the corneal endothelium. Improvement in mean endothelial cell density and percentage of hexagonality was observed in the contact lens group.
- 1 September 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (9) , 672-677
Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser
PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens group, mean endothelial cell density improved significantly from 3401±292 cells/mm 2 to 3587±262 cells/mm 2 ( P <.001) with a mean increase of 5.5%. The percentage of hexagonal cells was statistically significantly higher after surgery (32.5±4.0%) compared with preoperative data (31.0±5.1%) ( P =.035). No statistically significant differences were noted regarding mean endothelial cell density ( P =.126) or hexagonality ( P =.56) before and 1 year after femtosecond LASIK in the non-contact lens group. CONCLUSIONS: Femtosecond LASIK to correct myopia was safe for the corneal endothelium. Improvement in mean endothelial cell density and percentage of hexagonality was observed in the contact lens group.
- Open Access
- 1 August 2011
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 2 (2) , 273-278
Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus
Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmus characteristics after surgery. Conclusions: pIOL implantation may be a safe and suitable treatment to correct high refractive errors in patients with congenital nystagmus. Significant improvement in CDVA and UCVA can be achieved.
- 1 August 2011
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 2 (2) , 273-278
Open AccessArtiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus
Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmus characteristics after surgery. Conclusions: pIOL implantation may be a safe and suitable treatment to correct high refractive errors in patients with congenital nystagmus. Significant improvement in CDVA and UCVA can be achieved.
- 1 August 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (8) , 556-557
Subjective Refraction Before LASIK Enhancement in Bioptics Procedures With Refractive Multifocal Intraocular Lenses
- 1 August 2011
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (8) , 556-557
Subjective Refraction Before LASIK Enhancement in Bioptics Procedures With Refractive Multifocal Intraocular Lenses