Tom G. Moreels
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tom G. Moreels has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Benedicte Y. De Winter
Laboratory of Experimental Medicine and Pediatrics and Infla-Med Centre of Excellence, University of Antwerp, Antwerp, Belgium
9 shared publications - Paul A. Pelckmans
Division of Gastroenterology, Faculty of Medicine, University of Antwerp (UIA), Belgium
7 shared publications Paul A. Pelckmans
6 shared publications- Joris G. De Man
Division of Gastroenterology, Faculty of Medicine, University of Antwerp, Antwerp, Belgium
5 shared publications Arnold G. Herman
Laboratory of Pharmacology, University of Antwerp, 2610 Antwerp, Belgium
4 shared publications- Alex Loukas
Australian Institute of Tropical Health and Medicine, James Cook University, Cairns, Australia
3 shared publications
Latest Publications
- 1 December 2015
- Vol. 78 (4) , 411-4
Colonoscopy in patients with liver cirrhosis : success and safety issues.
Patients with liver cirrhosis undergo screening colonoscopy before liver transplantation. Screening colonoscopy is subject to specific quality criteria, among which caecal intubation rate. Several factors associated with failed caecal intubation have been identified. We investigated whether liver cirrhosis influenced success and safety of screening colonoscopy. Caecal intubation and complication rate of 93 candidates for liver transplantation due to liver cirrhosis were compared with the control rates of our endoscopy unit. Several patient and colonoscopy variables were taken into account. In patients with liver cirrhosis caecal intubation rate was only 83%, whereas in the control group it was 94% (P<0.0001). The presence of high volume ascites tends to compromise a successful colonoscopy. Serious complication rate was 0,4% in controls without colonoscopy-related mortality. In the cirrhotic population two severe complications were encountered (2,2%, P<0.05) and one patient died due to colonic perforation and sepsis (mortality 1.1%). Caecal intubation rate is significantly lower in patients with liver cirrhosis undergoing screening colonoscopy, possibly related to the presence of ascites. Complication and mortality rate of screening colonoscopy is significantly higher in patients being screened for liver transplantation.
- 1 December 2015
- Vol. 78 (4) , 411-4
Colonoscopy in patients with liver cirrhosis : success and safety issues.
Patients with liver cirrhosis undergo screening colonoscopy before liver transplantation. Screening colonoscopy is subject to specific quality criteria, among which caecal intubation rate. Several factors associated with failed caecal intubation have been identified. We investigated whether liver cirrhosis influenced success and safety of screening colonoscopy. Caecal intubation and complication rate of 93 candidates for liver transplantation due to liver cirrhosis were compared with the control rates of our endoscopy unit. Several patient and colonoscopy variables were taken into account. In patients with liver cirrhosis caecal intubation rate was only 83%, whereas in the control group it was 94% (P<0.0001). The presence of high volume ascites tends to compromise a successful colonoscopy. Serious complication rate was 0,4% in controls without colonoscopy-related mortality. In the cirrhotic population two severe complications were encountered (2,2%, P<0.05) and one patient died due to colonic perforation and sepsis (mortality 1.1%). Caecal intubation rate is significantly lower in patients with liver cirrhosis undergoing screening colonoscopy, possibly related to the presence of ascites. Complication and mortality rate of screening colonoscopy is significantly higher in patients being screened for liver transplantation.
- 1 February 2014
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 58 (2) , 141-142
The Next Novelty in Pediatric Endoscopy
- 1 February 2014
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 58 (2) , 141-142
The Next Novelty in Pediatric Endoscopy
- 13 August 2013
- Published by Springer Nature in Current Gastroenterology Reports
- Vol. 15 (9) , 1-6
ERCP in the Patient with Surgically Altered Anatomy
- 13 August 2013
- Published by Springer Nature in Current Gastroenterology Reports
- Vol. 15 (9) , 1-6
ERCP in the Patient with Surgically Altered Anatomy
- 1 August 2013
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 56 (8) , 1013-1018
Renewed Attention for Overtube-Assisted Colonoscopy to Prevent Incomplete Endoscopic Examination of the Colon
Colonoscopy is the standard examination to detect mucosal pathology in the colon. However, failure to complete colonoscopy may reach more than 10% in population-based endoscopy practices. The reasons for incomplete conventional colonoscopy are diverse and result in missed diagnosis of colonic polyps and carcinoma. Recent endoscopic developments have shown that the use of specialized overtubes may help to reach the cecum in the case of a difficult colonoscopy, even with less discomfort. Several types of overtubes are currently available, whereas other types are being developed and clinically evaluated. The current review highlights the development of overtubes for colonoscopy and the available clinical data on overtube-assisted colonoscopy in the case of incomplete conventional colonoscopy. Data were derived from a PubMed search through November 2012. Available clinical literature data on recent developments in overtube-assisted colonoscopy were studied. A descriptive comparison was made of currently available endoscopy systems used for overtube-assisted colonoscopy. The primary outcomes measured were the feasibility and safety of different endoscopy systems to perform overtube-assisted colonoscopy. Several overtube-assisted colonoscopy systems have recently been developed to complete colonoscopy in the case of difficult conventional colonoscopy. Literature data show excellent feasibility to reach the cecum with very low complication rates and good patient tolerance for the different overtube systems. The majority of available studies are uncontrolled case series describing 7 to 110 patients undergoing overtube-assisted colonoscopy with only 1 direct comparison between 2 overtube systems. Overtube-assisted colonoscopy has been shown to be useful in performing colonoscopy by increasing the cecal intubation rate and patient tolerance and by decreasing the need for sedation. There is no standardized superior overtube system at this moment.
- 1 August 2013
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 56 (8) , 1013-1018
Renewed Attention for Overtube-Assisted Colonoscopy to Prevent Incomplete Endoscopic Examination of the Colon
Colonoscopy is the standard examination to detect mucosal pathology in the colon. However, failure to complete colonoscopy may reach more than 10% in population-based endoscopy practices. The reasons for incomplete conventional colonoscopy are diverse and result in missed diagnosis of colonic polyps and carcinoma. Recent endoscopic developments have shown that the use of specialized overtubes may help to reach the cecum in the case of a difficult colonoscopy, even with less discomfort. Several types of overtubes are currently available, whereas other types are being developed and clinically evaluated. The current review highlights the development of overtubes for colonoscopy and the available clinical data on overtube-assisted colonoscopy in the case of incomplete conventional colonoscopy. Data were derived from a PubMed search through November 2012. Available clinical literature data on recent developments in overtube-assisted colonoscopy were studied. A descriptive comparison was made of currently available endoscopy systems used for overtube-assisted colonoscopy. The primary outcomes measured were the feasibility and safety of different endoscopy systems to perform overtube-assisted colonoscopy. Several overtube-assisted colonoscopy systems have recently been developed to complete colonoscopy in the case of difficult conventional colonoscopy. Literature data show excellent feasibility to reach the cecum with very low complication rates and good patient tolerance for the different overtube systems. The majority of available studies are uncontrolled case series describing 7 to 110 patients undergoing overtube-assisted colonoscopy with only 1 direct comparison between 2 overtube systems. Overtube-assisted colonoscopy has been shown to be useful in performing colonoscopy by increasing the cecal intubation rate and patient tolerance and by decreasing the need for sedation. There is no standardized superior overtube system at this moment.
- 30 June 2012
- Published by Elsevier in Best Practice & Research Clinical Gastroenterology
- Vol. 26 (3) , 347-357
Altered anatomy: Enteroscopy and ERCP procedure
- 30 June 2012
- Published by Elsevier in Best Practice & Research Clinical Gastroenterology
- Vol. 26 (3) , 347-357
Altered anatomy: Enteroscopy and ERCP procedure
- Open Access
- 1 January 2012
- Vol. 25 (1) , 14-20
Small bowel enteroscopy in Crohn’s disease
Endoscopic assessment of the small bowel is difficult because of its long and tortuous anatomy. However, recent developments have greatly improved the insertion depth and diagnostic yield, by means of device-assisted enteroscopy (DAE). Therefore, DAE may be of specific interest in the diagnostic and therapeutic approach of patients with inflammatory bowel disease. It may be of help in the diagnostic assessment of intestinal disease extent and severity and complications, with an impact on the therapeutic management. Moreover, local treatment within the small bowel is also feasible with DAE. This review aims to provide an overview of the currently available literature data on the use of enteroscopy in inflammatory bowel disease, and Crohn’s disease in particular.
- 1 January 2012
- Vol. 25 (1) , 14-20
Open AccessSmall bowel enteroscopy in Crohn’s disease
Endoscopic assessment of the small bowel is difficult because of its long and tortuous anatomy. However, recent developments have greatly improved the insertion depth and diagnostic yield, by means of device-assisted enteroscopy (DAE). Therefore, DAE may be of specific interest in the diagnostic and therapeutic approach of patients with inflammatory bowel disease. It may be of help in the diagnostic assessment of intestinal disease extent and severity and complications, with an impact on the therapeutic management. Moreover, local treatment within the small bowel is also feasible with DAE. This review aims to provide an overview of the currently available literature data on the use of enteroscopy in inflammatory bowel disease, and Crohn’s disease in particular.
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Effect of TRPV1 Blockade on Visceromotor Responses in Unanesthetized Rats With TNBS Colitis
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Effect of TRPV1 Blockade on Visceromotor Responses in Unanesthetized Rats With TNBS Colitis
- Open Access
- 16 March 2011
- Published by Springer Nature in BMC Gastroenterology
- Vol. 11 (1) , 23
Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis
Background: Percutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal malignancies is unknown. Methods: Retrospective analysis of 299 patients undergoing PEG tube placement between January 2006 and December 2008 revealed 57 oncology patients. All patients with head/neck or oesophageal malignancy were treated with chemo- and radiotherapy. In case of high-grade stenosis introducer Freka® Pexact PEG tube was placed (n = 24) and in all other patients (n = 33) conventional pull-type PEG tube. Short-term complications and mortality rates were compared. Results: Patients' characteristics and clinical status were comparable in both groups. Short-term complications were encountered in 11/24 (48%) introducer PEG patients as compared to only 4/33 (12%) pull-type PEG patients (P < 0.05). Accidental removal of the introducer PEG tube occurred in 4/24 (17%) with need for surgical intervention in 1 vs. 0/33 (0%, P < 0.05). Wound infection occurred in 3/24 (12%) leading to septic shock and admission to intensive care unit (ICU) in 1 vs. 3/33 (9%, NS). Finally, 3/24 gastrointestinal perforations (12%) resulted from a difficult placement procedure vs. 1/33 (3%), leading to urgent surgical intervention and admission to ICU. Two introducer PEG patients died at ICU, resulting in an overall mortality rate of 8% vs. 0% (P = 0.091). Conclusion: The introducer Freka® Pexact PEG procedure for long-term tube feeding may lead to significantly higher complication and mortality rates in patients with head/neck or oesophageal malignancies treated with chemo- and radiotherapy. It is suggested to use the conventional pull-type PEG tube placement in this group of patients, if possible.
- 16 March 2011
- Published by Springer Nature in BMC Gastroenterology
- Vol. 11 (1) , 23
Open AccessSafety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis
Background: Percutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal malignancies is unknown. Methods: Retrospective analysis of 299 patients undergoing PEG tube placement between January 2006 and December 2008 revealed 57 oncology patients. All patients with head/neck or oesophageal malignancy were treated with chemo- and radiotherapy. In case of high-grade stenosis introducer Freka® Pexact PEG tube was placed (n = 24) and in all other patients (n = 33) conventional pull-type PEG tube. Short-term complications and mortality rates were compared. Results: Patients' characteristics and clinical status were comparable in both groups. Short-term complications were encountered in 11/24 (48%) introducer PEG patients as compared to only 4/33 (12%) pull-type PEG patients (P < 0.05). Accidental removal of the introducer PEG tube occurred in 4/24 (17%) with need for surgical intervention in 1 vs. 0/33 (0%, P < 0.05). Wound infection occurred in 3/24 (12%) leading to septic shock and admission to intensive care unit (ICU) in 1 vs. 3/33 (9%, NS). Finally, 3/24 gastrointestinal perforations (12%) resulted from a difficult placement procedure vs. 1/33 (3%), leading to urgent surgical intervention and admission to ICU. Two introducer PEG patients died at ICU, resulting in an overall mortality rate of 8% vs. 0% (P = 0.091). Conclusion: The introducer Freka® Pexact PEG procedure for long-term tube feeding may lead to significantly higher complication and mortality rates in patients with head/neck or oesophageal malignancies treated with chemo- and radiotherapy. It is suggested to use the conventional pull-type PEG tube placement in this group of patients, if possible.