Hannes Antlinger
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hannes Antlinger has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Jakoby
Institute for Microelectronics and Microsensors, Johannes Kepler University Linz, Linz, Austria
5 shared publications Stefan Clara
Institute for Microelectronics and Microsensors, Linz, Austria
3 shared publications- Franz Keplinger
Institute of Sensor and Actuator Systems, Vienna University of Technology, Gusshausstraße 27-29, A-1040 Vienna, Austria
2 shared publications Roman Beigelbeck
Institute for Integrated Sensor Systems, Austrian Academy of Sciences, Viktor Kaplan Strasse 2, 2700 Wiener Neustadt, Austria
2 shared publicationsSamir Cerimovic
Institute of Sensor and Actuator Systems, Vienna University of Technology, Gusshausstraße 27-29, 1040 Vienna, Austria
2 shared publications- Stefan Clara
Institute for Microelectronics and Microsensors, Linz, Austria
2 shared publications
Latest Publications
- 10 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (3) , 1937-1944
A Viscosity and Density Sensor Based on Diamagnetically Stabilized Levitation
We investigate the feasibility of viscosity and density measurements using diamagnetically stabilized levitation of a floater magnet on pyrolytic graphite. This principle avoids any clamping structures in the measurement chamber and is, therefore, not suffering under unknown mounting conditions and is furthermore easy to integrate into microfluidic systems. The only part that has to be in contact with the liquid is the floater magnet. Immersing it in a liquid, buoyancy forces will come into play. Keeping the levitation height of the floater magnet constant in different liquid surroundings by accordingly adjusting the lifter magnet, the buoyancy force and, therefore, the density of the fluid can be determined from these adjustments. For more accurate results, a magnetic field modeling was used to determine the levitation height of the floater magnet out of the superposed magnetic fields of both magnets. For viscosity measurements, we add an additional ac-driven coil to the setup, which yields a superposed alternating force on the floater magnet causing periodic vibrations of the floater magnet. The vibrations are damped according to the viscosity of the surrounding fluid. By performing a frequency sweep, the frequency response of the damped spring mass resonator can be obtained where the resonance frequency for our setup is around 6 Hz. Furthermore, the influence of the levitation height on the resonance characteristics was examined by studying the resonance frequency and quality factor for different lifter magnet positions.
- 10 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (3) , 1937-1944
A Viscosity and Density Sensor Based on Diamagnetically Stabilized Levitation
We investigate the feasibility of viscosity and density measurements using diamagnetically stabilized levitation of a floater magnet on pyrolytic graphite. This principle avoids any clamping structures in the measurement chamber and is, therefore, not suffering under unknown mounting conditions and is furthermore easy to integrate into microfluidic systems. The only part that has to be in contact with the liquid is the floater magnet. Immersing it in a liquid, buoyancy forces will come into play. Keeping the levitation height of the floater magnet constant in different liquid surroundings by accordingly adjusting the lifter magnet, the buoyancy force and, therefore, the density of the fluid can be determined from these adjustments. For more accurate results, a magnetic field modeling was used to determine the levitation height of the floater magnet out of the superposed magnetic fields of both magnets. For viscosity measurements, we add an additional ac-driven coil to the setup, which yields a superposed alternating force on the floater magnet causing periodic vibrations of the floater magnet. The vibrations are damped according to the viscosity of the surrounding fluid. By performing a frequency sweep, the frequency response of the damped spring mass resonator can be obtained where the resonance frequency for our setup is around 6 Hz. Furthermore, the influence of the levitation height on the resonance characteristics was examined by studying the resonance frequency and quality factor for different lifter magnet positions.
- 13 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (10) , 3669-3676
Theoretical Analysis and Simulation Studies of the Orbiting Sphere Viscometer
We present the theoretical background of a previously introduced viscosity measurement system based on a principle similar to that of the well-known falling ball viscometer. Even though the falling ball viscometer does not allow a viscosity measurement at defined shear rates, it has been established as frequently used referenced method in the chemical industry and is still widely used today. We modified the mode of operation to permit continuous measurements by building an orbiting sphere viscometer, where a sphere mounted on a spring wire performs steady motions on a circular path. The movements are electromagnetically excited in a contactless manner such that the actuator does not have to be placed within the fluid. The readout can be performed by piezoelectric sensors (as described below) and alternatively also by means of inductive sensing. Classical rheometer principles (such as rotating cylinders or plate-cone arrangements) often involve precision drives and bearings which in our case were completely avoided. Both readout methods avoid also mechanical feedthroughs (e.g., in terms of a rotating shaft) where the inductive method additionally avoids electrical contacts in the measurement chamber. This is an important feature for process automation in the chemical industry, just as the possibility of continuous measurements, which allows uninterrupted control of the viscosity during a production process. Due to the easy scalability of the system it is applicable in a wide range of viscosities. Various operating modes are possible and allow different physical parameters to be sensed. In this paper, we describe those modes mathematically and compare them to the results of a finite element simulation. We furthermore analyze various spurious effects and studied the influences of geometrical design parameters associated with an experimental prototype.
- 13 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (10) , 3669-3676
Theoretical Analysis and Simulation Studies of the Orbiting Sphere Viscometer
We present the theoretical background of a previously introduced viscosity measurement system based on a principle similar to that of the well-known falling ball viscometer. Even though the falling ball viscometer does not allow a viscosity measurement at defined shear rates, it has been established as frequently used referenced method in the chemical industry and is still widely used today. We modified the mode of operation to permit continuous measurements by building an orbiting sphere viscometer, where a sphere mounted on a spring wire performs steady motions on a circular path. The movements are electromagnetically excited in a contactless manner such that the actuator does not have to be placed within the fluid. The readout can be performed by piezoelectric sensors (as described below) and alternatively also by means of inductive sensing. Classical rheometer principles (such as rotating cylinders or plate-cone arrangements) often involve precision drives and bearings which in our case were completely avoided. Both readout methods avoid also mechanical feedthroughs (e.g., in terms of a rotating shaft) where the inductive method additionally avoids electrical contacts in the measurement chamber. This is an important feature for process automation in the chemical industry, just as the possibility of continuous measurements, which allows uninterrupted control of the viscosity during a production process. Due to the easy scalability of the system it is applicable in a wide range of viscosities. Various operating modes are possible and allow different physical parameters to be sensed. In this paper, we describe those modes mathematically and compare them to the results of a finite element simulation. We furthermore analyze various spurious effects and studied the influences of geometrical design parameters associated with an experimental prototype.
- 6 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (6) , 1914-1922
An Electromagnetically Actuated Oscillating Sphere Used as a Viscosity Sensor
We present a novel viscosity sensor principle which utilizes an oscillating metal sphere attached to a wire acting as mechanical spring. The oscillation is electromagnetically excited using four actuation coils. The arrangement of the coils allows a linear oscillation in one plane but also a circular motion if the actuation coils are driven accordingly. The latter causes a constant speed of the sphere and thus, a stationary flow around the sphere, which allows probing a different rheological regime compared with the oscillation mode featuring continuous acceleration and deceleration. For viscosity measurements, the drag force acting on the sphere is the crucial parameter in the sensing approach. The calculation of this force requires modeling of the magnetic field generated by the actuation currents in the coils. To verify the model for the magnetic field and the forces, a COMSOL simulation was performed and the results were compared with those obtained with the model. Finally, the approach was verified by means of measurements using different viscous liquids (viscosity standard oils and water glycerol mixtures).
- 6 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 14 (6) , 1914-1922
An Electromagnetically Actuated Oscillating Sphere Used as a Viscosity Sensor
We present a novel viscosity sensor principle which utilizes an oscillating metal sphere attached to a wire acting as mechanical spring. The oscillation is electromagnetically excited using four actuation coils. The arrangement of the coils allows a linear oscillation in one plane but also a circular motion if the actuation coils are driven accordingly. The latter causes a constant speed of the sphere and thus, a stationary flow around the sphere, which allows probing a different rheological regime compared with the oscillation mode featuring continuous acceleration and deceleration. For viscosity measurements, the drag force acting on the sphere is the crucial parameter in the sensing approach. The calculation of this force requires modeling of the magnetic field generated by the actuation currents in the coils. To verify the model for the magnetic field and the forces, a COMSOL simulation was performed and the results were compared with those obtained with the model. Finally, the approach was verified by means of measurements using different viscous liquids (viscosity standard oils and water glycerol mixtures).
- Open Access
- 1 November 2013
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 202, 23-29
An acoustic transmission sensor for the longitudinal viscosity of fluids
- 1 November 2013
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 202, 23-29
Open AccessAn acoustic transmission sensor for the longitudinal viscosity of fluids
- Open Access
- 1 October 2012
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 186, 94-99
Sensing the characteristic acoustic impedance of a fluid utilizing acoustic pressure waves
- 1 October 2012
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 186, 94-99
Open AccessSensing the characteristic acoustic impedance of a fluid utilizing acoustic pressure waves