Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tobias Neumann has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Matthias Gruenewald

    Department of Anesthesiology and Intensive Care Medicine, Schleswig-Holstein University Hospital, Campus Kiel, Kiel, Germany

    3 shared publications
  • Christoph Lauenstein

    Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig‐Holstein, Kiel, Germany

    2 shared publications
  • Erol Cavus

    Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany

    2 shared publications
  • Maja Henninger

    University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Research Group "Clinical Research and Teaching", Kerpener Str. 62, 50937 Cologne, Germany

    2 shared publications
  • Patrick Meybohm

    Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Würzburg, Würzburg, Germany

    2 shared publications
  • Sebastian Lemke

    University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Anaesthesiology and Intensive Care Medicine, Research Group "Clinical Research and Teaching", Kerpener Str. 62, 50937 Cologne, Germany

    2 shared publications

Latest Publications

  • Open Access

    Glycocalyx-Shedding and Inflammatory Reactions Occur Yet Do Not Predict Complications Resulting from an Esophagectomy in an Accelerated Recovery After Surgery Program

    by Hendrik Drinhaus, Christoph Mallmann, Corvin Cleff, Tobias Neumann, Christina Daniels, Christiane J. Bruns, Andrea U. Steinbicker, Wolfgang Schröder, Thorsten Annecke

    Background/Objectives: “Accelerated Recovery after Surgery” (ARAS) programs for esophagectomy aim to shorten the perioperative course without increases in morbidity or mortality. In such programs, the prediction and early detection of perioperative complications is essential, as ICU observation times are limited. We evaluated two potential laboratory markers as predictors for postoperative complications: shedding of the endothelial glycocalyx and the veno-arterial CO2-gap as indicators of microcirculatory disturbances. Methods: In total, 26 patients undergoing hybrid Ivor Lewis esophagectomy within an ARAS program were included. Macrocirculatory conditions were kept stable by enhanced hemodynamic monitoring (PiCCO). Glycocalyx shedding parameters (Syndecan-1, heparan sulfate, hyaluronic acid) and a panel of inflammatory mediators were measured preoperatively, upon ICU-admission, and on the first postoperative day. The veno-arterial CO2-gap was calculated at induction of anesthesia, during laparoscopy, and upon admission to the ICU. Results: Complications (Dindo-Clavien ≥3) occurred in n = 16 (62%) patients. From preoperatively to admission to the ICU, Syndecan-1 (29 pre-op to 56 ng/mL at ICU-admission) and Interleukins 1b (1.2 to 1.4 pg/mL), 6 (1.3 to 19.9 pg/mL), 8 (5.2 to 19.9 pg/mL), and 10 (0.50 to 1.33 pg/mL) increased, indicating a temporary increase in inflammation and glycocalyx shedding during surgery. A difference between patients with or without complications could not be detected. There was also no difference in the veno-arterial CO2-gap between the two groups (median of 6.8 mmHg in all patients, 6.7 in patients with complications, 7.8 in patients without complications). Conclusions: Signs of microcirculatory dysfunctions and inflammation occurred during esophagectomy within an ARAS protocol with tightly controlled hemodynamics. Increases in Syndecan-1 and the veno-arterial CO2-gap could not predict perioperative complications.


  • Open Access

    First-time evaluation of ascending compared to rectangular transthoracic defibrillation waveforms in modelled out-of-hospital cardiac arrest

    by Tobias Neumann, Simon-Richard Finke, Maja Henninger, Sebastian Lemke, Ben Hoepfner, Daniel Steven, Alexandra C. Maul, Daniel C. Schroeder, Thorsten Annecke


  • Open Access

    4 - Global Oxygenation and Heart Lung Interaction Using “corpuls cpr” in a Real-Life Porcine Model of Cardiopulmonary Resuscitation (CPR).

    by Tobias Neumann, Simon-Richard Finke, Ben Höpfner, Sebastian Lemke, Maja Henninger, Pia Rademann, Daniel Schroeder

    Purpose of the Study Sufficient oxygen supply of heart and brain critically influences outcome after cardiac arrest (CA). Optimal results depend on the interaction of systemic and pulmonary circulation. Crucial for success are generated blood pressure and macro- and microcirculatory blood flow. Considering this, we investigated the chest compression (CC) device corpuls cpr (GS

  • 8 - Hemodynamics of corpuls cpr in a porcine model of cardiac arrest

    by Tobias Neumann

    Purpose of the study The debate on whether mechanical chest compression (CC) devices can be used for cardiopulmonary resuscitation (CPR) remains unresolved. To support this debate and since data on CC quality unbiased by pharmacotherapy is rare we present current hemodynamic data on the fairly new corpuls cpr (GS Elektromedizinische Geraete G. Stemple GmbH) from our animal

  • The Fibrin-Derived Peptide Bβ15–42 (FX06) Ameliorates Vascular Leakage and Improves Survival and Neurocognitive Recovery: Implications From Two Animal Models of Cardiopulmonary Resuscitation*

    by Stefan Bergt, Matthias Gruenewald, Claudia Beltschany, Andrea Grub, Tobias Neumann, Martin Albrecht, Brigitte Vollmar, Kai MD Zacharowski, Jan P. Roesner, Patrick Meybohm

    Objectives: The fibrin-derived peptide Bβ15–42 (FX06) has been proven to attenuate ischemia/reperfusion injury. We tested the hypothesis that Bβ15–42 improves survival rate and neurocognitive recovery after cardiopulmonary resuscitation. Design: Pig and mouse model of cardiopulmonary resuscitation. Setting: Two university hospitals. Subjects: Pigs and mice. Interventions: Pigs (n = 16) were subjected to 8-minute cardiac arrest. Successful resuscitated pigs (n = 12) were randomized either to 3 mg/kg Bβ15–42 followed by a continuous infusion of 1 mg/kg/hr for 5 hours (pFX06; n = 6) or the control group (pCONTROL; n = 6). Cardiac damage, function, and hemodynamics were recorded up to 8 hours. Mice (n = 52) were subjected to 4-minute cardiac arrest followed by cardiopulmonary resuscitation, and randomized either to two boli of 2.4 mg/kg Bβ15–42 (mFX06; n = 26) or the control group (mCONTROL; n = 26). Fourteen-day survival rate, neurocognitive function, and endothelial integrity (additional experiment with n = 26 mice) were evaluated. Measurements and Main Results: Bβ15–42 reduced cumulative fluid intake (3,500 [2,600–4,200] vs 6,800 [5,700–7,400] mL; p = 0.004) within 8 hours in pigs. In mice, Bβ15–42 improved 14-day survival rate (mFX06 vs mCONTROL; 11/26 vs 6/26; p < 0.05) and fastened neurocognitive recovery in the Water-Maze test (15/26 vs 9/26 mice with competence to perform test; p < 0.05). Bβ15–42-treated mice showed a significant higher length of intact pulmonary endothelium and reduced pulmonary leukocyte infiltration. Conclusions: This study confirms the new concept of an important role of fibrin derivatives in global ischemia/reperfusion injury, which can be attenuated by the fibrin-derived peptide Bβ15–42.


  • Open Access

    Hands‐On Defibrillation Has the Potential to Improve the Quality of Cardiopulmonary Resuscitation and Is Safe for Rescuers— A Preclinical Study

    by Tobias Neumann, Matthias Gruenewald, Christoph Lauenstein, Tobias Drews, Timo Iden, Patrick Meybohm

    Background: Recently, it has been demonstrated that rescuers could safely provide a low, static downward force in direct contact with patients during elective cardioversion. The purpose of our experimental study was to investigate whether shock delivery during uninterrupted chest compressions may have an impact on cardiopulmonary resuscitation ( CPR ) quality and can be safely performed in a realistic animal model of CPR . Methods and Results: Twenty anesthetized swine were subjected to 7 minutes of ventricular fibrillation followed by CPR according to the 2010 A merican H eart A ssociation G uidelines. Pregelled self‐adhesive defibrillation electrodes were attached onto the torso in the ventrodorsal direction and connected to a biphasic defibrillator. Animals were randomized either to (1) hands‐on defibrillation, where rescuers wore 2 pairs of polyethylene gloves and shocks were delivered during ongoing chest compressions, or (2) hands‐off defibrillation, where hands were taken off during defibrillation. CPR was successful in 9 out of 10 animals in the hands‐on group (versus 8 out of 10 animals in the hands‐off group; not significant). In the hands‐on group, chest compressions were interrupted for 0.8% [0.6%; 1.4%] of the total CPR time (versus 8.2% [4.2%; 9.0%]; P =0.0003), and coronary perfusion pressure was earlier restored to its pre‐interruption level ( P =0.0205). Also, rescuers neither sensed any kind of electric stimulus nor did H olter ECG reveal any serious cardiac arrhythmia. Conclusions: Hands‐on defibrillation may improve CPR quality and could be safely performed during uninterrupted chest compressions in our standardized porcine model.


  • Abstract 247: Hands-on Defibrillation Has the Potential to Improve CPR Quality and Is Safe for Rescuers: A Preclinical Study

    by Tobias Neumann, Matthias Gruenewald, Christoph Lauenstein, Peter Voelk, Anne Rosenthal, Isabell Hartramph, Tobias Drews, Timo Iden, Patrick Meybohm

    Background: It has been demonstrated that hands-on chest compressions (CC) during cardioversion in humans can be safely performed. [1] We assessed the hypothesis that it will be safe during CPR and improves its quality. Methods: Twenty anesthetized swine were subjected to V-fib and subsequent CPR. Self-adhesive defibrillation electrodes were used with a biphasic defibrillator (corpuls3, G. Stemple GmbH, Germany). Swine were randomized either to i) hands-on defibrillation, where rescuers wore polyethylene gloves and defibrillation was delivered during ongoing CC, or ii) conventional hands-off defibrillation. In the hands-on group CC were interrupted only for rhythm analysis, when a marked increase of arterial blood pressure or endtidal CO 2 was observed suggesting spontaneus circulation. Holter ECG was registered to analyze potential cardiac arrhythmias in rescuers. Results: ROSC was achieved in 9 out of 10 swine in the hands-on group compared to 8 out of 10 (ns). Interruptions in CC were reduced by hands-on technique (p < 0.001) and coronary perfusion pressure (CorPP) was earlier restored to the pre-shock level (p = 0.014). In only 13 of 34 cases (38 %) interruption of hands-on CPR revealed a stable spontaneous circulation. Transthoracic impedance was not significantly different (hands-on 66 ± 40 Ohm vs. hands-off 63 ± 24 Ohm, p = 0.720). During all 37 hands-on shocks rescuers never felt any kind of electric stimulus. Holter ECG analysis did not reveal any serious arrhythmia during hands-on CPR (SVES/h: 5.0 ± 5.4, PVC/h: 0.2 ± 0.5). Conclusions: Hands-on defibrillation shortens CPR pauses and fastens restoration of CorPP that is predictive for CPR outcome. More sophisticated ECG filters may enable rhythm analysis during ongoing CC to avoid unnecessary pauses. Hands-on CPR can be safely performed but clinical studies are needed before implementation into daily practice. References: 1. Lloyd MS et al. Circulation 2008; 117: 2510-4


  • First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation

    by Erol Cavus, Tobias Neumann, Volker Doerges, Thora Moeller, Edwin Scharf, Klaus Wagner, Berthold Bein, Goetz Serocki

    In the present preliminary study we evaluated the C-MAC® D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11 (5-45) seconds and for successful intubation 17 (3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required.