Peter Ewen King-Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Peter Ewen King-Smith has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jason J. Nichols
School of Optometry, The University of Alabama at Birmingham, Birmingham, AL, USA
9 shared publications Richard J. Braun
University of Delaware, Newark, DE, USA
9 shared publicationsKelly K. Nichols
College of Optometry, University of Houston, Houston, Texas
5 shared publicationsBarbara A. Fink
From the College of Optometry, Ohio State University, Columbus, Ohio; the
4 shared publicationsCarolyn G. Begley
Indiana University, Bloomington, IN, USA
4 shared publicationsSamuel H. Kimball
College of Optometry, The Ohio State University, Columbus, Ohio, United States
2 shared publications
Latest Publications
- Open Access
- 21 August 2025
- Published by Elsevier in The Ocular Surface
- Vol. 38, 251-259
Two models of the structures of the lamellae in human meibum and the tear film lipid layer, TFLL
- 21 August 2025
- Published by Elsevier in The Ocular Surface
- Vol. 38, 251-259
Open AccessTwo models of the structures of the lamellae in human meibum and the tear film lipid layer, TFLL
- Open Access
- 1 July 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 65 (8) , 41
High Resolution Images of Human Meibum Spread on Saline
Purpose: Understanding of the role of the tear film lipid layer (TFLL) in evaporative dry eye requires knowledge of its structure. X-ray studies show 11.1-nm thick lamellae in meibum at tear film temperature (approximately 35°C), whereas below 30°C, 4.88-nm thick lamellae predominate. Here, high resolution microscopy of meibum spread on saline is studied as a function of temperature, to compare with x-ray results. Methods: A purpose-built high resolution color microscope, previously used to study the TFLL, was used to study meibum from 10 subjects. It was spread on buffered saline at near 40°C, and allowed to cool to room temperature. Analytical methods from previous studies were applied to measure meibum and lamellar thickness. Results: Initially, an irregular “island” was formed, surrounded by a “background layer” of 7.8 ± 0.3 nm thickness. Dewetting of the meibum layer always occurred, leading to the formation of lens-shaped droplets. Below 30°C, the lenses start to emit “tails” having a multilamellar structure containing up to about 49 lamellae superimposed on the background layer, each lamella being 4.82 ± 0.13 nm thick. Conclusions: Below 30°C, meibum spread on saline shows a multilamellar structure like the 4.88 nm thickness in x-ray studies, demonstrating the ability to observe and measure tightly stacked lamellae. In contrast, above 30°C, the 11.1 nm lamellae were not observed as in x-ray studies, indicating that these lamellae were not tightly stacked but may be separated by disordered lipid. The role of these findings in evaporative dry eye is discussed.
- 1 July 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 65 (8) , 41
Open AccessHigh Resolution Images of Human Meibum Spread on Saline
Purpose: Understanding of the role of the tear film lipid layer (TFLL) in evaporative dry eye requires knowledge of its structure. X-ray studies show 11.1-nm thick lamellae in meibum at tear film temperature (approximately 35°C), whereas below 30°C, 4.88-nm thick lamellae predominate. Here, high resolution microscopy of meibum spread on saline is studied as a function of temperature, to compare with x-ray results. Methods: A purpose-built high resolution color microscope, previously used to study the TFLL, was used to study meibum from 10 subjects. It was spread on buffered saline at near 40°C, and allowed to cool to room temperature. Analytical methods from previous studies were applied to measure meibum and lamellar thickness. Results: Initially, an irregular “island” was formed, surrounded by a “background layer” of 7.8 ± 0.3 nm thickness. Dewetting of the meibum layer always occurred, leading to the formation of lens-shaped droplets. Below 30°C, the lenses start to emit “tails” having a multilamellar structure containing up to about 49 lamellae superimposed on the background layer, each lamella being 4.82 ± 0.13 nm thick. Conclusions: Below 30°C, meibum spread on saline shows a multilamellar structure like the 4.88 nm thickness in x-ray studies, demonstrating the ability to observe and measure tightly stacked lamellae. In contrast, above 30°C, the 11.1 nm lamellae were not observed as in x-ray studies, indicating that these lamellae were not tightly stacked but may be separated by disordered lipid. The role of these findings in evaporative dry eye is discussed.
- Open Access
- 21 July 2022
- Published by Taylor & Francis in Current Eye Research
- Vol. 47 (10) , 1355-1361
A Perspective on the Use of Fluorescent Imaging to Reveal Mechanisms of Breakup
Purpose: Tear film instability, which can lead to rapid tear film breakup (TBU), is considered to be a major etiological factor in dry eye. However, experimental support for many of the proposed theories for TBU mechanisms is relatively scarce. The major aim of this perspective is to show that fluorescence studies of TBU can be used to provide experimental evidence for two proposed underlying mechanisms of TBU, evaporation and divergent flow. Methods: To understand the effects of TBU on tear film fluorescence, we show that local fluorescence is the product of three main factors: tear film thickness, fluorescein concentration and fluorescent efficiency. In divergent tear flow, tear film thickness is reduced without change in fluorescein concentration and fluorescent efficiency, thus leading to reduced fluorescence intensity. Evaporation causes decreased fluorescence mainly by self-quenching due to high fluorescein concentration. Fluorescent efficiency is reduced by quenching at high fluorescein concentration but is independent of concentration for very low fluorescein concentration; thus, comparison of high and very low concentrations of fluorescein can be used to discriminate between divergent flow and evaporation. Finally, it is shown how the fluorescent pattern can change greatly during the development of breakup. Conclusions: This analysis demonstrates that the study of tear film fluorescence in TBU and dry eye may be underutilized as additional information pertinent to clinical practice may be obtained. A better understanding of TBU mechanisms may lead to improved diagnosis and treatment of dry eye.
- 21 July 2022
- Published by Taylor & Francis in Current Eye Research
- Vol. 47 (10) , 1355-1361
Open AccessA Perspective on the Use of Fluorescent Imaging to Reveal Mechanisms of Breakup
Purpose: Tear film instability, which can lead to rapid tear film breakup (TBU), is considered to be a major etiological factor in dry eye. However, experimental support for many of the proposed theories for TBU mechanisms is relatively scarce. The major aim of this perspective is to show that fluorescence studies of TBU can be used to provide experimental evidence for two proposed underlying mechanisms of TBU, evaporation and divergent flow. Methods: To understand the effects of TBU on tear film fluorescence, we show that local fluorescence is the product of three main factors: tear film thickness, fluorescein concentration and fluorescent efficiency. In divergent tear flow, tear film thickness is reduced without change in fluorescein concentration and fluorescent efficiency, thus leading to reduced fluorescence intensity. Evaporation causes decreased fluorescence mainly by self-quenching due to high fluorescein concentration. Fluorescent efficiency is reduced by quenching at high fluorescein concentration but is independent of concentration for very low fluorescein concentration; thus, comparison of high and very low concentrations of fluorescein can be used to discriminate between divergent flow and evaporation. Finally, it is shown how the fluorescent pattern can change greatly during the development of breakup. Conclusions: This analysis demonstrates that the study of tear film fluorescence in TBU and dry eye may be underutilized as additional information pertinent to clinical practice may be obtained. A better understanding of TBU mechanisms may lead to improved diagnosis and treatment of dry eye.
- Open Access
- 7 February 2020
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 61 (2) , 42
Optical Analysis and Reappraisal of the Peripheral Light Focusing Theory of Nasal Pterygia Formation
Purpose: Pterygia are much more common nasally than temporally. Ultraviolet (UV) radiation is a major risk factor. Coroneo proposed that the nasal preference is caused by the “peripheral light focusing effect,” (PLF), in which UV at an oblique angle passes through temporal cornea and is concentrated on and damages nasal limbal stem cells. This study evaluates whether the PLF is sufficient to explain the nasal preference. Methods: Whereas Coroneo and colleagues derived the maximum PLF intensity gain (UV concentration factor) as a function of incident angle (i.e., different nasal limbal positions were used for different incident angles) the current analysis derived intensity gain at a fixed position such at the nasal corneo-limbal junction (CLJ). This provided a measure of the total PLF irradiation at this position, which was compared to total direct irradiation of nasal and temporal limbus at the corresponding positions (e.g., CLJs). In Part 1, analysis was performed like that of Coroneo, using horizontally incident UV; in Part 2, the analysis was extended to include incident rays above and below the horizontal. Results: In both part 1 and part 2 of the study, the limbal UV irradiation of the nasal limbus from the PLF was not sufficient to explain the strong nasal location preference of pterygia. Conclusions: The analysis calls into question the PLF explanation of nasal location preference. Other explanations of the nasal preference, and of pterygium pathogenesis, should be considered, such as temporal to nasal tear flow carrying substances such as cytokines to the nasal limbus.
- 7 February 2020
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 61 (2) , 42
Open AccessOptical Analysis and Reappraisal of the Peripheral Light Focusing Theory of Nasal Pterygia Formation
Purpose: Pterygia are much more common nasally than temporally. Ultraviolet (UV) radiation is a major risk factor. Coroneo proposed that the nasal preference is caused by the “peripheral light focusing effect,” (PLF), in which UV at an oblique angle passes through temporal cornea and is concentrated on and damages nasal limbal stem cells. This study evaluates whether the PLF is sufficient to explain the nasal preference. Methods: Whereas Coroneo and colleagues derived the maximum PLF intensity gain (UV concentration factor) as a function of incident angle (i.e., different nasal limbal positions were used for different incident angles) the current analysis derived intensity gain at a fixed position such at the nasal corneo-limbal junction (CLJ). This provided a measure of the total PLF irradiation at this position, which was compared to total direct irradiation of nasal and temporal limbus at the corresponding positions (e.g., CLJs). In Part 1, analysis was performed like that of Coroneo, using horizontally incident UV; in Part 2, the analysis was extended to include incident rays above and below the horizontal. Results: In both part 1 and part 2 of the study, the limbal UV irradiation of the nasal limbus from the PLF was not sufficient to explain the strong nasal location preference of pterygia. Conclusions: The analysis calls into question the PLF explanation of nasal location preference. Other explanations of the nasal preference, and of pterygium pathogenesis, should be considered, such as temporal to nasal tear flow carrying substances such as cytokines to the nasal limbus.
- 1 January 2018
- Published by Elsevier in The Ocular Surface
- Vol. 16 (1) , 4-30
Mechanisms, imaging and structure of tear film breakup
- 1 January 2018
- Published by Elsevier in The Ocular Surface
- Vol. 16 (1) , 4-30
Mechanisms, imaging and structure of tear film breakup
- Open Access
- 1 March 2016
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 57 (3) , 959
The Evaporation Barrier of the Tear Film Lipid Layer
The article about instability and break-up of model tear films by Bhamla et al. 1 helps to clarify a longstanding puzzle about the evaporation resistance of the tear film lipid layer (TFLL). In a classic study, Mishima and Maurice 2 concluded that the TFLL reduced evaporation rate by a factor of approximately 15. However, Brown and Dervichian 3 found that meibum (meibomian gland lipid), spread on a beaker of saline, produced no detectable reduction in evaporation rate, and their finding has been confirmed several times. Thus, either the conclusion of Mishima and Maurice is incorrect 4 or else meibum spread on saline differs from the in vivo TFLL. Bhamla et al. 1 generated a model tear film by raising an upward-facing contact lens through the surface of an artificial tear solution covered by a thin layer of meibum. Initially, the tear film drained due to gravity, but as it thinned, flow from gravity was reduced greatly by viscous drag, so thinning was controlled mainly by evaporation. An imaging system was incorporated to view optical interference in this model tear film; initially interference showed the structure of the superficial lipid layer, but at a later stage, interference could be observed in the aqueous layer. The important findings were that small regions of aqueous tear film remained long after other regions had dried from evaporation, and these small regions were correlated with the observed lipid pattern. Therefore, the results support the conclusion that the TFLL is an effective barrier to evaporation. 1 However, when meibum is spread on a beaker of saline, only small areas are effective evaporation barriers, so any reduction in evaporation rate is not detectable. Thus, compared to the in vivo TFLL, the in vitro meibum layer has a reduced ability to spread and form a continuous evaporation barrier over an aqueous substrate.
- 1 March 2016
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 57 (3) , 959
Open AccessThe Evaporation Barrier of the Tear Film Lipid Layer
The article about instability and break-up of model tear films by Bhamla et al. 1 helps to clarify a longstanding puzzle about the evaporation resistance of the tear film lipid layer (TFLL). In a classic study, Mishima and Maurice 2 concluded that the TFLL reduced evaporation rate by a factor of approximately 15. However, Brown and Dervichian 3 found that meibum (meibomian gland lipid), spread on a beaker of saline, produced no detectable reduction in evaporation rate, and their finding has been confirmed several times. Thus, either the conclusion of Mishima and Maurice is incorrect 4 or else meibum spread on saline differs from the in vivo TFLL. Bhamla et al. 1 generated a model tear film by raising an upward-facing contact lens through the surface of an artificial tear solution covered by a thin layer of meibum. Initially, the tear film drained due to gravity, but as it thinned, flow from gravity was reduced greatly by viscous drag, so thinning was controlled mainly by evaporation. An imaging system was incorporated to view optical interference in this model tear film; initially interference showed the structure of the superficial lipid layer, but at a later stage, interference could be observed in the aqueous layer. The important findings were that small regions of aqueous tear film remained long after other regions had dried from evaporation, and these small regions were correlated with the observed lipid pattern. Therefore, the results support the conclusion that the TFLL is an effective barrier to evaporation. 1 However, when meibum is spread on a beaker of saline, only small areas are effective evaporation barriers, so any reduction in evaporation rate is not detectable. Thus, compared to the in vivo TFLL, the in vitro meibum layer has a reduced ability to spread and form a continuous evaporation barrier over an aqueous substrate.
- 1 March 2015
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 45, 132-164
Dynamics and function of the tear film in relation to the blink cycle
- 1 March 2015
- Published by Elsevier in Progress in Retinal and Eye Research
- Vol. 45, 132-164
Dynamics and function of the tear film in relation to the blink cycle
- Open Access
- 1 April 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (4) , 2614-2618
Tear Film Interferometry and Corneal Surface Roughness
Purpose. Previous studies of optical interference from the whole thickness of the precorneal tear film showed much lower contrast than from the pre–contact lens tear film. It is hypothesized that the recorded low contrast is related to roughness of the corneal surface compared with the smooth contact lens surface. This hypothesis is tested, and characteristics of this roughness are studied. Methods. Reflectance spectra were recorded from 20 healthy individuals using a silicon-based sensor used in previous studies (wavelength range, 562–1030 nm) and an indium-gallium-arsenide (InGaAs) sensor responding at longer wavelengths (912–1712 nm). Interference from the whole thickness of the precorneal tear film caused oscillations in the reflectance spectra. Results. Spectral oscillations recorded with the InGaAs sensor were found to decay as a Gaussian function of wave number (1/wavelength). This is consistent with a rough corneal surface, whose distribution of surface height is also a Gaussian function. Contrast of spectral oscillations for the InGaAs sensor was, on average, approximately four times greater than that for the silicon sensor. Conclusions. For the Gaussian roughness model based on InGaAs spectra, the corneal surface was characterized by a surface height SD of 0.129 μm. Spectral oscillations recorded with a silicon-based camera can have higher contrast than expected from this Gaussian roughness model, indicating some reflectance from a smoother or more compact surface. The results also indicate that InGaAs cameras could provide whole-thickness interference images of higher contrast than silicon-based cameras.
- 1 April 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (4) , 2614-2618
Open AccessTear Film Interferometry and Corneal Surface Roughness
Purpose. Previous studies of optical interference from the whole thickness of the precorneal tear film showed much lower contrast than from the pre–contact lens tear film. It is hypothesized that the recorded low contrast is related to roughness of the corneal surface compared with the smooth contact lens surface. This hypothesis is tested, and characteristics of this roughness are studied. Methods. Reflectance spectra were recorded from 20 healthy individuals using a silicon-based sensor used in previous studies (wavelength range, 562–1030 nm) and an indium-gallium-arsenide (InGaAs) sensor responding at longer wavelengths (912–1712 nm). Interference from the whole thickness of the precorneal tear film caused oscillations in the reflectance spectra. Results. Spectral oscillations recorded with the InGaAs sensor were found to decay as a Gaussian function of wave number (1/wavelength). This is consistent with a rough corneal surface, whose distribution of surface height is also a Gaussian function. Contrast of spectral oscillations for the InGaAs sensor was, on average, approximately four times greater than that for the silicon sensor. Conclusions. For the Gaussian roughness model based on InGaAs spectra, the corneal surface was characterized by a surface height SD of 0.129 μm. Spectral oscillations recorded with a silicon-based camera can have higher contrast than expected from this Gaussian roughness model, indicating some reflectance from a smoother or more compact surface. The results also indicate that InGaAs cameras could provide whole-thickness interference images of higher contrast than silicon-based cameras.
- 1 October 2013
- Published by Elsevier in The Ocular Surface
- Vol. 11 (4) , 236-245
Four Characteristics and a Model of an Effective Tear Film Lipid Layer (TFLL)
- 1 October 2013
- Published by Elsevier in The Ocular Surface
- Vol. 11 (4) , 236-245
Four Characteristics and a Model of an Effective Tear Film Lipid Layer (TFLL)
- 1 September 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (9) , 6003-6011
Tear Film Images and Breakup Analyzed Using Fluorescent Quenching
Purpose. Tear evaporation should increase fluorescein concentration, causing fluorescence dimming from self-quenching for high but not low fluorescein concentration. This prediction was tested and compared to the predicted effect of “tangential flow” that fluorescence dimming should be similar for high and low concentrations. Methods. A custom optical system was used for video recording of tear film fluorescence in 30 subjects. The subjects were asked to blink at the start of the recording and try to keep their eyes open for the rest of the 60-second recording. An initial recording was made after instillation of 1 μL 0.1% fluorescein followed by further recordings at 5-minute intervals using 0.5% and 5% fluorescein. Results. Decay of fluorescence was considerably greater for the high (5%) concentration condition than for the low (0.1%) concentration. This is shown by “ratio images” (ratio of the intensity of a fluorescence image at a later time divided by that of an earlier image), fluorescence decay curves, fluorescence decay rates, and histograms of estimated tear thickness decrease. For example, for the high concentration condition, decay rates were higher than for the low concentration for all 30 subjects (P < 0.0001, binomial test). Additionally, breakup time was significantly reduced for the high compared to the low concentration condition. Conclusions. The greater fluorescence decay and more rapid breakup for the high concentration condition are the results expected if thinning and breakup are mainly due to evaporation, hence causing self-quenching. Fluorescence decay rate for the low concentration condition was not significantly greater than zero.
- 1 September 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (9) , 6003-6011
Tear Film Images and Breakup Analyzed Using Fluorescent Quenching
Purpose. Tear evaporation should increase fluorescein concentration, causing fluorescence dimming from self-quenching for high but not low fluorescein concentration. This prediction was tested and compared to the predicted effect of “tangential flow” that fluorescence dimming should be similar for high and low concentrations. Methods. A custom optical system was used for video recording of tear film fluorescence in 30 subjects. The subjects were asked to blink at the start of the recording and try to keep their eyes open for the rest of the 60-second recording. An initial recording was made after instillation of 1 μL 0.1% fluorescein followed by further recordings at 5-minute intervals using 0.5% and 5% fluorescein. Results. Decay of fluorescence was considerably greater for the high (5%) concentration condition than for the low (0.1%) concentration. This is shown by “ratio images” (ratio of the intensity of a fluorescence image at a later time divided by that of an earlier image), fluorescence decay curves, fluorescence decay rates, and histograms of estimated tear thickness decrease. For example, for the high concentration condition, decay rates were higher than for the low concentration for all 30 subjects (P < 0.0001, binomial test). Additionally, breakup time was significantly reduced for the high compared to the low concentration condition. Conclusions. The greater fluorescence decay and more rapid breakup for the high concentration condition are the results expected if thinning and breakup are mainly due to evaporation, hence causing self-quenching. Fluorescence decay rate for the low concentration condition was not significantly greater than zero.