ISIan A. Sigal

Ian A. Sigal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ian A. Sigal has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Jonathan L. Grimm

    Department of Ophthalmology, UPMC Eye Center, Ophthalmology and Visual Science Research Center, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania

    4 shared publications
  • Hiroshi Ishikawa

    Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA

    2 shared publications
  • Larry Kagemann

    Lead reviewer, US Food and Drug Administration, Silver Spring, MD; Adjunct Associate Professor of Ophthalmology, NYU Langone Medical Center, NYU School of Medicine, New York, NY

    2 shared publications
  • Benjamin Aaron Alman

    Program in Developmental and Stem Cell Biology, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada

    1 shared publication
  • Bo Wang

    Department of Ophthalmology, UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA

    1 shared publication
  • Cari M. Whyne

    Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, MG361, Toronto, ON, M4N 3M5, Canada. address for D. Nam:

    1 shared publication

Latest Publications

  • Parameters for Lithium Treatment Are Critical in Its Enhancement of Fracture-Healing in Rodents

    by Joshua Bernick, Yufa Wang, Ian A. Sigal, Benjamin A. Alman, Cari M. Whyne, Diane Nam

    Background:Lithium, a treatment for bipolar disorder, is not clinically indicated for use in fracture management but has been reported to positively influence bone biology. It is hypothesized that lithium dosing for beneficial effects on bone health may be much lower than the dosing required for psy


  • Open Access

    Recent advances in OCT imaging of the lamina cribrosa

    by Ian A Sigal, Bo Wang, Nicholas G Strouthidis, Tadamichi Akagi, Michael J A Girard

    The lamina cribrosa (LC) is believed to be the site of injury to retinal ganglion cell axons in glaucoma. The ability to visualise this structure has the potential to help increase our understanding of the disease and be useful in the early detection of glaucoma. While for many years the research on the LC was essentially dependent on histology and modelling, a number of recent advances in optical coherence tomography (OCT) have dramatically improved the ability to visualise the LC, such that it is now possible to image the LC in vivo in humans and animals. In this review, we highlight recent advances in OCT imaging of the LC, in the technology, processing and analysis, and discuss the impact that these will have on the ability to diagnose and monitor glaucoma, as well as to expand our understanding of its pathophysiology. With this manuscript, we aspire to share our excitement on the achievements and potential of recent developments as well as advise caution regarding the challenges that remain before imaging of the LC and optic nerve can be used routinely in clinical practice.


  • A Method to Estimate Biomechanics and Mechanical Properties of Optic Nerve Head Tissues From Parameters Measurable Using Optical Coherence Tomography

    by I. A. Sigal, J. L. Grimm, J. S. Schuman, L. Kagemann, H. Ishikawa, G. Wollstein

    Optic nerve head (ONH) tissue properties and biomechanics remain mostly unmeasurable in the experiment. We hypothesized that these can be estimated numerically from ocular parameters measurable in vivo with optical coherence tomography (OCT). Using parametric models representing human ONHs we simulated acute intraocular pressure (IOP) increases (10 mmHg). Statistical models were fit to predict, from OCT-measurable parameters, 15 outputs, including ONH tissue properties, stresses, and deformations. The calculations were repeated adding parameters that have recently been proposed as potentially measurable with OCT. We evaluated the sensitivity of the predictions to variations in the experimental parameters. Excellent fits were obtained to predict all outputs from the experimental parameters, with cross-validated R2s between 0.957 and 0.998. Incorporating the potentially measurable parameters improved fits significantly. Predictions of tissue stiffness were accurate to within 0.66 MPa for the sclera and 0.24 MPa for the lamina cribrosa. Predictions of strains and stresses were accurate to within 0.62% and 4.9 kPa, respectively. Estimates of ONH biomechanics and tissue properties can be obtained quickly from OCT measurements using an applet that we make freely available. These estimates may improve understanding of the eye sensitivity to IOP and assessment of patient risk for development or progression of glaucoma.


  • Open Access

    Eye-Specific IOP-Induced Displacements and Deformations of Human Lamina Cribrosa

    by Ian A. Sigal, Jonathan L. Grimm, Ning-Jiun Jan, Korey Reid, Don S. Minckler, Donald J. Brown

    Purpose. To measure high-resolution eye-specific displacements and deformations induced within the human LC microstructure by an acute increase in IOP. Methods. Six eyes from donors aged 23 to 82 were scanned using second harmonic-generated (SHG) imaging at various levels of IOP from 10 to 50 mm Hg. An image registration technique was developed, tested, and used to find the deformation mapping between maximum intensity projection images acquired at low and elevated IOP. The mappings were analyzed to determine the magnitude and distribution of the IOP-induced displacements and deformations and contralateral similarity. Results. Images of the LC were obtained and the registration technique was successful. IOP increases produced substantial, and potentially biologically significant, levels of in-plane LC stretch and compression (reaching 10%–25% medians and 20%–30% 75th percentiles). Deformations were sometimes highly focal and concentrated in regions as small as a few pores. Regions of largest displacement, stretch, compression, and shear did not colocalize. Displacements and strains were not normally distributed. Contralateral eyes did not always have more similar responses to IOP than unrelated eyes. Under elevated IOP, some LC regions were under bi-axial stretch, others under bi-axial compression. Conclusions. We obtained eye-specific measurements of the complex effects of IOP on the LC with unprecedented resolution in uncut and unfixed human eyes. Our technique was robust to electronic and speckle noise. Elevated IOP produced substantial in-plane LC stretch and compression. Further research will explore the effects of IOP on the LC in a three-dimensional framework.


  • Human Lamina Cribrosa Insertion and Age

    by Ian A. Sigal, John G. Flanagan, Kira L. Lathrop, Inka Tertinegg, Richard Bilonick

    To test the hypothesis that in healthy human eyes the lamina cribrosa (LC) insertion into the pia mater increases with age. The optic nerve heads (ONHs) of donor eyes fixed at either 5 or 50 mm Hg of IOP were sectioned, stained, and imaged under bright- and dark-field conditions. A 3-dimensional (3D) model of each ONH was reconstructed. From the 3D models we measured the area of LC insertion into the peripapillary scleral flange and into the pia, and computed the total area of insertion and fraction of LC inserting into the pia. Linear mixed effect models were used to determine if the measurements were associated with age or IOP. We analyzed 21 eyes from 11 individuals between 47 and 91 years old. The LC inserted into the pia in all eyes. The fraction of LC inserting into the pia (2.2%-29.6%) had a significant decrease with age (P = 0.049), which resulted from a nonsignificant increase in the total area of LC insertion (P = 0.41) and a nonsignificant decrease in the area of LC insertion into the pia (P = 0.55). None of the measures was associated with fixation IOP (P values 0.44-0.81). Differences between fellow eyes were smaller than differences between unrelated eyes. The LC insertion into the pia mater is common in middle-aged and older eyes, and does not increase with age. The biomechanical and vascular implications of the LC insertion into the pia mater are not well understood and should be investigated further.


  • A Few Good Responses: Which Mechanical Effects of IOP on the ONH to Study?

    by Ian A. Sigal, Jonathan L. Grimm

    The biomechanical effects of IOP on the optic nerve head (ONH) are believed to play a role in glaucomatous neuropathy. There is, however, no consensus on which effects of IOP should be prioritized for investigation. Our goal was to identify a small set of variables capturing the majority of the effects of acute IOP on the ONH. We produced 4646 finite element models of the human ONH representing a wide range of tissue anatomies and mechanical properties. The effects of IOP were quantified through a set of 25 responses including stress, strain, and geometric deformation of the lamina cribrosa (LC) and peripapillary sclera. The correlations between the responses were analyzed and principal component analysis (PCA) was used to identify uncorrelated variables capturing the largest possible variance in the responses. The responses formed groups with strong correlations. The top five principal components (PCs) accounted for 72.8%, 13.0%, 7.1%, 3.1%, and 2.0% of the variance, respectively. Few PCs capture the majority of the mechanical effects of acute changes in IOP on the ONH, which previously required 25 measures. The PCs represented four key effects of IOP: lateral deformation associated with canal expansion (PC1), anterior-posterior deformation of the LC and the forces through it determined by either the mechanical properties of the LC (PC2) or of the neural tissue (PC4), rotation of the peripapillary sclera (PC5), and forces through the peripapillary sclera (PC3). A small set of uncorrelated variables will simplify describing and understanding the effects of IOP on the ONH.


  • The Optic Nerve Head as a Robust Biomechanical System

    by Ian A. Sigal, Richard A. Bilonick, Larry Kagemann, Gadi Wollstein, Hiroshi Ishikawa, Joel S. Schuman, Jonathan L. Grimm

    Purpose. Understanding the effects of IOP on the optic nerve head (ONH) is important in understanding glaucoma and ONH structure and function. The authors tested the hypothesis that the ONH is a robust biomechanical structure wherein various factors combine to produce a relatively stable response to IOP. Methods. The authors generated two populations of 100,000 ONH numerical models each with randomly selected values, but controlled distributions, either uniform or Gaussian, of ONH geometry and mechanical properties. The authors predicted the lamina cribrosa displacement (LCD), scleral canal expansion (SCE), and the stresses (forces) and deformations (strains) produced by a 10 mm Hg increase in IOP. The authors analyzed the distributions of the responses. Results. The responses were distributed nonuniformly, with the majority of the models having a response within a small region, often less than 30% of the size of the overall response region. This concentration of responses was more marked in the Gaussian population than in the uniform population. All the responses were positively skewed. Whether a particular case was typical or not depended on the response used for classification and on whether the decision was made using one-dimensional or two-dimensional criteria. Conclusions. Despite wide variations in ONH characteristics and responses to IOP, some responses were much more common than others. This supports conceiving of the eye as a robust structure, particularly for LCD and SCE, which is tolerant to variations in tissue geometry and mechanical properties. The authors also provide the first estimates of the typical mechanical response of the ONH to variations in IOP over a large population of ONHs.


  • IOP-Induced Lamina Cribrosa Deformation and Scleral Canal Expansion: Independent or Related?

    by Ian A. Sigal, Hongli Yang, Michael D. Roberts, Jonathan L. Grimm, Claude F. Burgoyne, Shaban Demirel, J. Crawford Downs

    Purpose.: To study the association between the intraocular pressure (IOP)–induced anterior–posterior lamina cribrosa deformation (LCD) and scleral canal expansion (SCE). Methods.: 3D eye-specific models of the lamina and sclera of the eyes of three normal monkeys were constructed. Morphing techniques were used to produce 768 models with controlled variations in geometry and materials. Finite element analysis was used to predict the LCD and SCE resulting from an increase in IOP. We analyzed the association between LCD and SCE for the population as a whole, and for subsets. Results.: For some conditions, such as deep and stiff lamina, the association between LCD and SCE was strong and consistent with the concept of “the sclera pulls the lamina taut” as IOP increases. For other conditions, such as shallow and compliant lamina, there was no association. Further, for other conditions, such as for thin and stiff sclera, the association was opposite to the tautening. Although most of the models had similar response to IOP, some cases had peculiarly large LCD and SCE. The properties of the lamina cribrosa (LC) greatly influenced its response to variations in IOP; for example, deep laminas tended to displace anteriorly, whereas shallow LCs displaced little or posteriorly. Conclusions.: The association between LCD and SCE varied greatly depending on the properties of the lamina and sclera, which shows that it is critical to consider the characteristics of the population when interpreting measurements of LCD and SCE. This work is the first systematic analysis of the relationship between LCD and SCE.


  • Open Access

    An Applet to Estimate the IOP-Induced Stress and Strain within the Optic Nerve Head

    by Ian A. Sigal

    Purpose.: The ability to predict the biomechanical response of the optic nerve head (ONH) to intraocular pressure (IOP) elevation holds great promise, yet remains elusive. The objective of this work was to introduce an approach to model ONH biomechanics that combines the ease of use and speed of analytical models with the flexibility and power of numerical models. Methods.: Models representing a variety of ONHs were produced, and finite element (FE) techniques used to predict the stresses (forces) and strains (relative deformations) induced on each of the models by IOP elevations (up to 10 mm Hg). Multivariate regression was used to parameterize each biomechanical response as an analytical function. These functions were encoded into a Flash-based applet. Applet utility was demonstrated by investigating hypotheses concerning ONH biomechanics posited in the literature. Results.: All responses were parameterized well by polynomials (R 2 values between 0.985 and 0.999), demonstrating the effectiveness of our fitting approach. Previously published univariate results were reproduced with the applet in seconds. A few minutes allowed for multivariate analysis, with which it was predicted that often, but not always, larger eyes experience higher levels of stress and strain than smaller ones, even at the same IOP. Conclusions.: An applet has been presented with which it is simple to make rapid estimates of IOP-related ONH biomechanics. The applet represents a step toward bringing the power of FE modeling beyond the specialized laboratory and can thus help develop more refined biomechanics-based hypotheses. The applet is available for use at www.ocularbiomechanics.com.