Loretta Szczotka-Flynn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Loretta Szczotka-Flynn has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Alfred Rimm
From the *Department of Ophthalmology and Visual Sciences, Case Western Reserve University and University Hospitals Eye Institute, Cleveland, OH; †Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada; ‡Department of Population Health Sciences, University of Wisconsin Madison, Madison, WI; and §Department of Epidemiology and Biostatistics, Case Western Reserve University, Cleveland, OH
3 shared publicationsBeth Ann Benetz
Univ Hosp, Univ Hosp Case Med Ctr, Inst Eye, 11100 Euclid Ave,Lakeside 4126C, Cleveland, OH 44106 USA
3 shared publicationsEric Pearlman
Departments of Ophthalmology, and Physiology and Biophysics University of California, Irvine Irvine California
3 shared publicationsSara Debanne
Case Western Reserve Univ, Dept Epidemiol & Biostat, Cleveland, OH 44106 USA
3 shared publicationsAjay Sethi
From the *Department of Ophthalmology and Visual Sciences, Case Western Reserve University and University Hospitals Eye Institute, Cleveland, OH; †Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada; ‡Department of Population Health Sciences, University of Wisconsin Madison, Madison, WI; and §Department of Epidemiology and Biostatistics, Case Western Reserve University, Cleveland, OH
2 shared publicationsBeth Gillespie
From the *Department of Ophthalmology and Visual Sciences, Case Western Reserve University and University Hospitals Eye Institute, Cleveland, OH; †Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada; ‡Department of Population Health Sciences, University of Wisconsin Madison, Madison, WI; and §Department of Epidemiology and Biostatistics, Case Western Reserve University, Cleveland, OH
2 shared publications
Latest Publications
- Open Access
- 9 September 2022
- Published by Wolters Kluwer Health in Cornea
- Vol. 41 (12) , 1539-1544
Comparison of Graft Outcomes Reusing Original Intermediate-Term Cold Storage Solution for Entire Corneal Donor Storage Period With Exchanged Fresh Storage Solution After Donor Preparation in the Cornea Preservation Time Study
Purpose: The purpose of this study was to evaluate outcomes of Descemet stripping automated endothelial keratoplasty comparing exchange with fresh intermediate-term cold storage solution after lenticule preparation versus reuse of the original solution in the Cornea Preservation Time Study. Methods: In the Cornea Preservation Time Study, 508 donor corneas had lenticules prepared by the eye bank with fresh solution exchange (Fresh group) and 283 with reuse of the original solution (Original group). Storage time for all donors was ≤11 days. Graft success rates, central endothelial cell loss at 3 years, and frequency of positive donor rim cultures were compared between the 2 groups. Results: The 3-year graft success rate (95% confidence interval) was 93.4% (90.7%–95.3%) in the Fresh group and 95.2% (91.8%–97.2%) in the Original group (adjusted hazard ratio for graft failure = 0.64, 95% confidence interval, 0.33–1.24, P = 0.19). The mean percentage endothelial cell loss was significantly greater in the Fresh group versus Original group (45% ± 22% vs. 38% ± 20%, respectively, P = 0.004). Cultures were positive in 4 (1.5%) of 267 donor rims (3 fungal and 1 bacterial) in the Fresh group and in 4 (2.5%) of 158 in the Original group (P = 0.57). There were 2 postoperative infections in the Original group and none in the Fresh group. Conclusions: The use of the original intermediate-term cold storage solution did not reduce the 3-year graft success rate compared with exchanging with fresh solution after lenticule preparation for Descemet stripping automated endothelial keratoplasty, while the frequency of positive donor rim cultures did not significantly differ between groups.
- 9 September 2022
- Published by Wolters Kluwer Health in Cornea
- Vol. 41 (12) , 1539-1544
Open AccessComparison of Graft Outcomes Reusing Original Intermediate-Term Cold Storage Solution for Entire Corneal Donor Storage Period With Exchanged Fresh Storage Solution After Donor Preparation in the Cornea Preservation Time Study
Purpose: The purpose of this study was to evaluate outcomes of Descemet stripping automated endothelial keratoplasty comparing exchange with fresh intermediate-term cold storage solution after lenticule preparation versus reuse of the original solution in the Cornea Preservation Time Study. Methods: In the Cornea Preservation Time Study, 508 donor corneas had lenticules prepared by the eye bank with fresh solution exchange (Fresh group) and 283 with reuse of the original solution (Original group). Storage time for all donors was ≤11 days. Graft success rates, central endothelial cell loss at 3 years, and frequency of positive donor rim cultures were compared between the 2 groups. Results: The 3-year graft success rate (95% confidence interval) was 93.4% (90.7%–95.3%) in the Fresh group and 95.2% (91.8%–97.2%) in the Original group (adjusted hazard ratio for graft failure = 0.64, 95% confidence interval, 0.33–1.24, P = 0.19). The mean percentage endothelial cell loss was significantly greater in the Fresh group versus Original group (45% ± 22% vs. 38% ± 20%, respectively, P = 0.004). Cultures were positive in 4 (1.5%) of 267 donor rims (3 fungal and 1 bacterial) in the Fresh group and in 4 (2.5%) of 158 in the Original group (P = 0.57). There were 2 postoperative infections in the Original group and none in the Fresh group. Conclusions: The use of the original intermediate-term cold storage solution did not reduce the 3-year graft success rate compared with exchanging with fresh solution after lenticule preparation for Descemet stripping automated endothelial keratoplasty, while the frequency of positive donor rim cultures did not significantly differ between groups.
- 1 March 2021
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (3) , 182-198
American Academy of Optometry Microbial Keratitis Think Tank
SIGNIFICANCE: Think Tank 2019 affirmed that the rate of infection associated with contact lenses has not changed in several decades. Also, there is a trend toward more serious infections associated with Acanthamoeba and fungi. The growing use of contact lenses in children demands our attention with surveillance and case‐control studies. PURPOSE: The American Academy of Optometry (AAO) gathered researchers and key opinion leaders from around the world to discuss contact lens–associated microbial keratitis at the 2019 AAO Annual Meeting. METHODS: Experts presented within four sessions. Session 1 covered the epidemiology of microbial keratitis, pathogenesis of Pseudomonas aeruginosa , and the role of lens care systems and storage cases in corneal disease. Session 2 covered nonbacterial forms of keratitis in contact lens wearers. Session 3 covered future needs, challenges, and research questions in relation to microbial keratitis in youth and myopia control, microbiome, antimicrobial surfaces, and genetic susceptibility. Session 4 covered compliance and communication imperatives. RESULTS: The absolute rate of microbial keratitis has remained very consistent for three decades despite new technologies, and extended wear significantly increases the risk. Improved oxygen delivery afforded by silicone hydrogel lenses has not impacted the rates, and although the introduction of daily disposable lenses has minimized the risk of severe disease, there is no consistent evidence that they have altered the overall rate of microbial keratitis. Overnight orthokeratology lenses may increase the risk of microbial keratitis, especially secondary to Acanthamoeba , in children. Compliance remains a concern and a significant risk factor for disease. New insights into host microbiome and genetic susceptibility may uncover new theories. More studies such as case‐control designs suited for rare diseases and registries are needed. CONCLUSIONS: The first annual AAO Think Tank acknowledged that the risk of microbial keratitis has not decreased over decades, despite innovation. Important questions and research directions remain.
- 1 March 2021
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (3) , 182-198
American Academy of Optometry Microbial Keratitis Think Tank
SIGNIFICANCE: Think Tank 2019 affirmed that the rate of infection associated with contact lenses has not changed in several decades. Also, there is a trend toward more serious infections associated with Acanthamoeba and fungi. The growing use of contact lenses in children demands our attention with surveillance and case‐control studies. PURPOSE: The American Academy of Optometry (AAO) gathered researchers and key opinion leaders from around the world to discuss contact lens–associated microbial keratitis at the 2019 AAO Annual Meeting. METHODS: Experts presented within four sessions. Session 1 covered the epidemiology of microbial keratitis, pathogenesis of Pseudomonas aeruginosa , and the role of lens care systems and storage cases in corneal disease. Session 2 covered nonbacterial forms of keratitis in contact lens wearers. Session 3 covered future needs, challenges, and research questions in relation to microbial keratitis in youth and myopia control, microbiome, antimicrobial surfaces, and genetic susceptibility. Session 4 covered compliance and communication imperatives. RESULTS: The absolute rate of microbial keratitis has remained very consistent for three decades despite new technologies, and extended wear significantly increases the risk. Improved oxygen delivery afforded by silicone hydrogel lenses has not impacted the rates, and although the introduction of daily disposable lenses has minimized the risk of severe disease, there is no consistent evidence that they have altered the overall rate of microbial keratitis. Overnight orthokeratology lenses may increase the risk of microbial keratitis, especially secondary to Acanthamoeba , in children. Compliance remains a concern and a significant risk factor for disease. New insights into host microbiome and genetic susceptibility may uncover new theories. More studies such as case‐control designs suited for rare diseases and registries are needed. CONCLUSIONS: The first annual AAO Think Tank acknowledged that the risk of microbial keratitis has not decreased over decades, despite innovation. Important questions and research directions remain.
- 1 February 2021
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 44 (1) , 108-114
Acute corneal edema decades after penetrating keratoplasty for keratoconus in eyes wearing scleral contact lenses
- 1 February 2021
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 44 (1) , 108-114
Acute corneal edema decades after penetrating keratoplasty for keratoconus in eyes wearing scleral contact lenses
- 1 November 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (11) , 892
Authors' Response
- 1 November 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (11) , 892
Authors' Response
- 2 May 2018
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 44 (3) , 190-199
Daily Wear Contact Lenses Manufactured in Etafilcon A Are Noninferior to Two Silicone Hydrogel Lens Types With Respect to Hypoxic Stress
This study hypothesized that a traditional high-water contact lens of moderate oxygen transmissibility (Dk/t) is noninferior to common silicone hydrogel (SH) lenses worn for daily wear with respect to measures of hypoxic stress. Thirty-six habitual contact lens wearers completed wear of three lens types worn in a randomized order: etafilcon A (ACUVUE 2, control), lotrafilcon B (Air Optix Aqua), and comfilcon A (Biofinity). Central corneal thickness (CT) and limbal hyperemia were measured >2 hr after waking and after 6 to 8 hr of wear on days 1 and 7. Endothelial bleb formation was measured on day 1 of each lens type. Noninferiority of etafilcon A, with respect to the other two lens types, was assumed if the following difference margins of equivalence were met: <1.5% for corneal swelling, <0.5 grade for limbal hyperemia, and <1% area of endothelial blebs. Outcomes were modeled using generalized linear mixed modeling techniques. All lenses showed reductions in least-square mean estimates of CT on both days: etafilcon A −0.26% at day 1 and −0.31% at day 7; lotrafilcon B −1.11% at day 1 and −1.06% at day 7; comfilcon A −0.63% at day 1 and −0.84% at day 7. The difference in mean swelling between etafilcon A and lotrafilcon B was 0.85% at day 1 (95% confidence interval [0.4%–1.3%]) and 0.75% at day 7 (0.3%–1.2%). The difference in mean swelling between etafilcon A and comfilcon A was 0.37% at day 1 (−0.1% to 0.8%) and 0.53% at day 7 (0.1%–1.0%). For limbal redness, etafilcon A fell within 0.1 grade of lotrafilcon B and 0.18 grade of comfilcon A. For endothelial bleb formation, etafilcon A fell within 0.45% of lotrafilcon B and 0.23% of comfilcon A. The etafilcon A control lens resulted in corneal deswelling throughout the day as did the SH lens types. Limbal hyperemia and endothelial bleb formation with all lenses were negligible, and noninferiority assumptions were met between the lens types for all outcomes. Equivalence of etafilcon A with respect to the two SH lenses for three measures of hypoxic stress was demonstrated.
- 2 May 2018
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 44 (3) , 190-199
Daily Wear Contact Lenses Manufactured in Etafilcon A Are Noninferior to Two Silicone Hydrogel Lens Types With Respect to Hypoxic Stress
This study hypothesized that a traditional high-water contact lens of moderate oxygen transmissibility (Dk/t) is noninferior to common silicone hydrogel (SH) lenses worn for daily wear with respect to measures of hypoxic stress. Thirty-six habitual contact lens wearers completed wear of three lens types worn in a randomized order: etafilcon A (ACUVUE 2, control), lotrafilcon B (Air Optix Aqua), and comfilcon A (Biofinity). Central corneal thickness (CT) and limbal hyperemia were measured >2 hr after waking and after 6 to 8 hr of wear on days 1 and 7. Endothelial bleb formation was measured on day 1 of each lens type. Noninferiority of etafilcon A, with respect to the other two lens types, was assumed if the following difference margins of equivalence were met: <1.5% for corneal swelling, <0.5 grade for limbal hyperemia, and <1% area of endothelial blebs. Outcomes were modeled using generalized linear mixed modeling techniques. All lenses showed reductions in least-square mean estimates of CT on both days: etafilcon A −0.26% at day 1 and −0.31% at day 7; lotrafilcon B −1.11% at day 1 and −1.06% at day 7; comfilcon A −0.63% at day 1 and −0.84% at day 7. The difference in mean swelling between etafilcon A and lotrafilcon B was 0.85% at day 1 (95% confidence interval [0.4%–1.3%]) and 0.75% at day 7 (0.3%–1.2%). The difference in mean swelling between etafilcon A and comfilcon A was 0.37% at day 1 (−0.1% to 0.8%) and 0.53% at day 7 (0.1%–1.0%). For limbal redness, etafilcon A fell within 0.1 grade of lotrafilcon B and 0.18 grade of comfilcon A. For endothelial bleb formation, etafilcon A fell within 0.45% of lotrafilcon B and 0.23% of comfilcon A. The etafilcon A control lens resulted in corneal deswelling throughout the day as did the SH lens types. Limbal hyperemia and endothelial bleb formation with all lenses were negligible, and noninferiority assumptions were met between the lens types for all outcomes. Equivalence of etafilcon A with respect to the two SH lenses for three measures of hypoxic stress was demonstrated.
- 1 September 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (5) , 473-481
Epidemiology of contact lens‐induced infiltrates: an updated review
Corneal infiltrative events (CIEs) are well established as a risk associated with soft contact lens wear. The incidence of symptomatic CIEs during extended soft lens wear ranges from 2.5 to six per cent; when asymptomatic CIEs are included, the incidence can be as high as 20–25 per cent. In daily soft lens wear, the annual incidence of symptomatic CIEs is about three per cent. There are various accepted methods of categorising CIEs, and a scoring system based on clinical signs and symptoms is a good approach to grade severity. Lens-related risk factors include extended wear, silicone hydrogel material, the use of multipurpose solutions, bacterial bioburden and reusable lenses. Recent studies report that daily disposable lenses reduce the risk of CIEs.
- 1 September 2017
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 100 (5) , 473-481
Epidemiology of contact lens‐induced infiltrates: an updated review
Corneal infiltrative events (CIEs) are well established as a risk associated with soft contact lens wear. The incidence of symptomatic CIEs during extended soft lens wear ranges from 2.5 to six per cent; when asymptomatic CIEs are included, the incidence can be as high as 20–25 per cent. In daily soft lens wear, the annual incidence of symptomatic CIEs is about three per cent. There are various accepted methods of categorising CIEs, and a scoring system based on clinical signs and symptoms is a good approach to grade severity. Lens-related risk factors include extended wear, silicone hydrogel material, the use of multipurpose solutions, bacterial bioburden and reusable lenses. Recent studies report that daily disposable lenses reduce the risk of CIEs.
- 19 November 2016
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 40 (1) , 33-41
The impact of lens care solutions on corneal epithelial changes during daily silicone hydrogel contact lens wear as measured by in vivo confocal microscopy
- 19 November 2016
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 40 (1) , 33-41
The impact of lens care solutions on corneal epithelial changes during daily silicone hydrogel contact lens wear as measured by in vivo confocal microscopy
- 1 May 2014
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 40 (3) , 117-122
Risk Factors for Contact Lens–Induced Papillary Conjunctivitis Associated With Silicone Hydrogel Contact Lens Wear
Background: Contact lens–induced papillary conjunctivitis (CLPC) continues to be a major cause of dropout during extended wear of contact lenses. This retrospective study explores risk factors for the development of CLPC during extended wear of silicone hydrogel lenses. Methods: Data from 205 subjects enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens study wearing lotrafilcon A silicone hydrogel lenses for up to 30 days of continuous wear were used to determine risk factors for CLPC in this secondary analysis of the main cohort. The main covariates of interest included substantial lens-associated bacterial bioburden and topographically determined lens base curve-to-cornea fitting relationships. Additional covariates of interest included history of adverse events, time of year, race, education level, gender, and other subject demographics. Statistical analyses included univariate logistic regression to assess the impact of potential risk factors on the binary CLPC outcome and Cox proportional hazards regression to describe the impact of those factors on time-to-CLPC diagnosis. Results: Across 12 months of follow-up, 52 subjects (25%) experienced CLPC. No associations were found between the CLPC development and the presence of bacterial bioburden, lens-to-cornea fitting relationships, history of adverse events, gender, or race. Contact lens–induced papillary conjunctivitis development followed the same seasonal trends as the local peaks in environmental allergens. Conclusions: Lens fit and biodeposits, in the form of lens-associated bacterial bioburden, were not associated with the development of CLPC during extended wear with lotrafilcon A silicone hydrogel lenses.
- 1 May 2014
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 40 (3) , 117-122
Risk Factors for Contact Lens–Induced Papillary Conjunctivitis Associated With Silicone Hydrogel Contact Lens Wear
Background: Contact lens–induced papillary conjunctivitis (CLPC) continues to be a major cause of dropout during extended wear of contact lenses. This retrospective study explores risk factors for the development of CLPC during extended wear of silicone hydrogel lenses. Methods: Data from 205 subjects enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens study wearing lotrafilcon A silicone hydrogel lenses for up to 30 days of continuous wear were used to determine risk factors for CLPC in this secondary analysis of the main cohort. The main covariates of interest included substantial lens-associated bacterial bioburden and topographically determined lens base curve-to-cornea fitting relationships. Additional covariates of interest included history of adverse events, time of year, race, education level, gender, and other subject demographics. Statistical analyses included univariate logistic regression to assess the impact of potential risk factors on the binary CLPC outcome and Cox proportional hazards regression to describe the impact of those factors on time-to-CLPC diagnosis. Results: Across 12 months of follow-up, 52 subjects (25%) experienced CLPC. No associations were found between the CLPC development and the presence of bacterial bioburden, lens-to-cornea fitting relationships, history of adverse events, gender, or race. Contact lens–induced papillary conjunctivitis development followed the same seasonal trends as the local peaks in environmental allergens. Conclusions: Lens fit and biodeposits, in the form of lens-associated bacterial bioburden, were not associated with the development of CLPC during extended wear with lotrafilcon A silicone hydrogel lenses.
- 1 May 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (5) , 696-701
An Association Between the Calpastatin (CAST) Gene and Keratoconus
Purpose: Keratoconus (KC) is a genetically heterogeneous corneal dystrophy. Previously, we performed 2 genome-wide linkage scans in a 4-generation autosomal dominant pedigree and repeatedly mapped a KC locus to a genomic region located on chromosome 5q overlapping the gene encoding the inhibitor of calpains, calpastatin (CAST). To test whether variants in CAST gene are involved in genetic susceptibility to KC, we performed genetic testing of polymorphic markers in CAST gene in family and case–control panels of patients with KC. Methods: We genotyped single-nucleotide polymorphisms (SNPs) located in CAST gene in 262 patients in 40 white KC families and in a white case–control panel with 304 cases and 518 controls. Generalized estimating equation models accounting for familial correlations implemented in GWAF program were used for association testing in families. Logistic regression models implemented in PLINK were performed to test the associations in case–control samples. Results: Genetic testing of the first set of 7 SNPs in familial samples revealed 2 tentative nominally significant markers (rs4869307, P = 0.03; rs27654, P = 0.07). Additional genotyping of 12 tightly spaced SNPs identified CAST SNP rs4434401 to be associated with KC in both familial and case–control panels with P values of 0.005 and 0.05, respectively, and with combined meta P value of familial and case–control cohorts of 0.002 or after Bonferroni correction of 0.04. Conclusions: Linkage analysis and genetic association support involvement of CAST gene in the genetic susceptibility to KC. In silico analysis of CAST expression suggests differential regulation of calpain/calpastatin system in cornea as a potential mechanism of functional defect.
- 1 May 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (5) , 696-701
An Association Between the Calpastatin (CAST) Gene and Keratoconus
Purpose: Keratoconus (KC) is a genetically heterogeneous corneal dystrophy. Previously, we performed 2 genome-wide linkage scans in a 4-generation autosomal dominant pedigree and repeatedly mapped a KC locus to a genomic region located on chromosome 5q overlapping the gene encoding the inhibitor of calpains, calpastatin (CAST). To test whether variants in CAST gene are involved in genetic susceptibility to KC, we performed genetic testing of polymorphic markers in CAST gene in family and case–control panels of patients with KC. Methods: We genotyped single-nucleotide polymorphisms (SNPs) located in CAST gene in 262 patients in 40 white KC families and in a white case–control panel with 304 cases and 518 controls. Generalized estimating equation models accounting for familial correlations implemented in GWAF program were used for association testing in families. Logistic regression models implemented in PLINK were performed to test the associations in case–control samples. Results: Genetic testing of the first set of 7 SNPs in familial samples revealed 2 tentative nominally significant markers (rs4869307, P = 0.03; rs27654, P = 0.07). Additional genotyping of 12 tightly spaced SNPs identified CAST SNP rs4434401 to be associated with KC in both familial and case–control panels with P values of 0.005 and 0.05, respectively, and with combined meta P value of familial and case–control cohorts of 0.002 or after Bonferroni correction of 0.04. Conclusions: Linkage analysis and genetic association support involvement of CAST gene in the genetic susceptibility to KC. In silico analysis of CAST expression suggests differential regulation of calpain/calpastatin system in cornea as a potential mechanism of functional defect.
- 1 January 2013
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 39 (1) , 48-52
Incidence and Epidemiologic Associations of Corneal Infiltrates With Silicone Hydrogel Contact Lenses
Contact lens-associated corneal infiltrative events (CIEs) are presumed sterile events that have complicated contact lens wear for more than 30 years. There is consistent evidence that silicone hydrogel soft contact lenses increase CIE risk by twofold compared with low Dk hydrogel materials. The incidence of CIEs during silicone hydrogel extended wear ranges from 2% to 6% for symptomatic events and from 6% to 25% when asymptomatic events are included. For daily wear, with silicone hydrogels, the incidence of CIEs ranges from 2% to 3% for symptomatic events and from 7% to 20% when asymptomatic events are included. Despite the increased rate of CIEs with silicone hydrogels, the benefits of these lenses largely outweigh this risk for many patients. Most risk factors for CIEs observed with silicone hydrogels are consistent with CIE risk factors reported earlier with hydrogel lenses, such as bacterial bioburden on lens surfaces, and young age among others. Limiting the transfer of bacterial bioburden from the skin to lenses, lens cases and eventually to the eye is an obvious step forward for the prevention of CIEs across all lens types.
- 1 January 2013
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 39 (1) , 48-52
Incidence and Epidemiologic Associations of Corneal Infiltrates With Silicone Hydrogel Contact Lenses
Contact lens-associated corneal infiltrative events (CIEs) are presumed sterile events that have complicated contact lens wear for more than 30 years. There is consistent evidence that silicone hydrogel soft contact lenses increase CIE risk by twofold compared with low Dk hydrogel materials. The incidence of CIEs during silicone hydrogel extended wear ranges from 2% to 6% for symptomatic events and from 6% to 25% when asymptomatic events are included. For daily wear, with silicone hydrogels, the incidence of CIEs ranges from 2% to 3% for symptomatic events and from 7% to 20% when asymptomatic events are included. Despite the increased rate of CIEs with silicone hydrogels, the benefits of these lenses largely outweigh this risk for many patients. Most risk factors for CIEs observed with silicone hydrogels are consistent with CIE risk factors reported earlier with hydrogel lenses, such as bacterial bioburden on lens surfaces, and young age among others. Limiting the transfer of bacterial bioburden from the skin to lenses, lens cases and eventually to the eye is an obvious step forward for the prevention of CIEs across all lens types.