Melissa D. Bailey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Melissa D. Bailey has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Loraine T. Sinnott
The Ohio State University College of Optometry Claremont McKenna College Claremont California
6 shared publicationsChiu‐Yen Kao
Department of Mathematical Sciences Claremont McKenna College Claremont California
4 shared publicationsKarla Zadnik
3 shared publicationsDeepinder K. Dhaliwal
From The Ohio State University College of Optometry (Bailey, Twa, Mitchell, Jones), Columbus, Ohio, the University of Pittsburgh, Eye and Ear Institute (Dhaliwal), Pittsburgh, Pennsylvania, and the University of Illinois at Chicago, Department of Ophthalmology & Visual Sciences (McMahon), Chicago, Illinois, USA
2 shared publicationsKathryn Richdale
SUNY College of Optometry New York New York
2 shared publicationsLynn G. Mitchell
From The Ohio State University College of Optometry (Bailey, Twa, Mitchell, Jones), Columbus, Ohio, the University of Pittsburgh, Eye and Ear Institute (Dhaliwal), Pittsburgh, Pennsylvania, and the University of Illinois at Chicago, Department of Ophthalmology & Visual Sciences (McMahon), Chicago, Illinois, USA
2 shared publications
Latest Publications
- 1 November 2013
- Published by Wiley in Optometry and Vision Science
- Vol. 90 (11) , 1312-1320
Ciliary Muscle Thickness in Anisometropia
Purpose: The purpose of this study was to investigate the relationships between ciliary muscle thickness (CMT), refractive error, and axial length both across subjects and between the more and less myopic eyes of adults with anisometropia. Methods: Both eyes of 29 adult subjects with at least 1.00 D of anisometropia were measured. Ciliary muscle thickness was measured at the maximum thickness (CMTMAX) and at 1.0 (CMT1), 2.0 (CMT2), and 3.0 mm (CMT3) posterior to the scleral spur, and also at the apical region (Apical CMTMAX = CMTMAX − CMT2, and Apical CMT1 = CMT1 − CMT2). Multilevel regression models were used to determine the relationship between the various CMT measures and cycloplegic refractive error or axial length, and to assess whether there are CMT differences between the more and less myopic eyes of an anisometropic adult. Results: CMTMAX, CMT1, CMT2, and CMT3 were negatively associated with mean refractive error (all p ≤ 0.03), and the strongest association was in the posterior region (CMT2 and CMT3). Apical CMTMAX and Apical CMT1, however, were positively associated with mean refractive error (both p < 0.0001) across subjects. Within a subject, i.e., comparing the two anisometropic eyes, there was no statistically significant difference in CMT in any region. Conclusions: Similar to previous studies, across anisometropic subjects, a thicker posterior region of the ciliary muscle (CMT2 and CMT3) was associated with increased myopic refractive error. Conversely, shorter, more hyperopic eyes tended to have thicker anterior, apical fiber portions of their ciliary muscle (Apical CMTMAX and Apical CMT1). There was no difference between the two eyes for any CMT measurement, indicating that in anisometropia, an eye can grow longer and more myopic than its fellow eye without resulting in an increase in CMT.
- 1 November 2013
- Published by Wiley in Optometry and Vision Science
- Vol. 90 (11) , 1312-1320
Ciliary Muscle Thickness in Anisometropia
Purpose: The purpose of this study was to investigate the relationships between ciliary muscle thickness (CMT), refractive error, and axial length both across subjects and between the more and less myopic eyes of adults with anisometropia. Methods: Both eyes of 29 adult subjects with at least 1.00 D of anisometropia were measured. Ciliary muscle thickness was measured at the maximum thickness (CMTMAX) and at 1.0 (CMT1), 2.0 (CMT2), and 3.0 mm (CMT3) posterior to the scleral spur, and also at the apical region (Apical CMTMAX = CMTMAX − CMT2, and Apical CMT1 = CMT1 − CMT2). Multilevel regression models were used to determine the relationship between the various CMT measures and cycloplegic refractive error or axial length, and to assess whether there are CMT differences between the more and less myopic eyes of an anisometropic adult. Results: CMTMAX, CMT1, CMT2, and CMT3 were negatively associated with mean refractive error (all p ≤ 0.03), and the strongest association was in the posterior region (CMT2 and CMT3). Apical CMTMAX and Apical CMT1, however, were positively associated with mean refractive error (both p < 0.0001) across subjects. Within a subject, i.e., comparing the two anisometropic eyes, there was no statistically significant difference in CMT in any region. Conclusions: Similar to previous studies, across anisometropic subjects, a thicker posterior region of the ciliary muscle (CMT2 and CMT3) was associated with increased myopic refractive error. Conversely, shorter, more hyperopic eyes tended to have thicker anterior, apical fiber portions of their ciliary muscle (Apical CMTMAX and Apical CMT1). There was no difference between the two eyes for any CMT measurement, indicating that in anisometropia, an eye can grow longer and more myopic than its fellow eye without resulting in an increase in CMT.
- Open Access
- 1 July 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (7) , 4710-4716
Region-Specific Relationships Between Refractive Error and Ciliary Muscle Thickness in Children
Purpose. To determine if there is a relationship between refractive error and ciliary muscle thickness in different muscle regions. Methods. An anterior segment optical coherence tomographer was used to measure cycloplegic ciliary muscle thicknesses at 1 mm (CMT1), 2 mm (CMT2), and 3 mm (CMT3) posterior to the scleral spur; maximum (CMTMAX) thickness was also assessed. An autorefractor was used to determine cycloplegic spherical equivalent refractive error (SPHEQ). Apical ciliary muscle fibers were obtained by subtracting corresponding CMT2 values from CMT1 and CMTMAX. Multilevel regression models were used to determine the relationship between ciliary muscle thickness in various regions of the muscle and refractive error. Results. Subjects included 269 children with a mean age of 8.71 ± 1.51 years and a mean refractive error of +0.41 ± 1.29 diopters. In linear models with ciliary muscle thicknesses and SPHEQ, SPHEQ was significantly associated only with CMT2 (β = −11.34, P = 0.0008) and CMT 3 (β = −6.97, P = 0.007). When corresponding values of CMT2 were subtracted from CMT1 and CMTMAX, apical fibers at CMT1 (β = 14.75, P < 0.0001) and CMTMAX (β = 18.16, P < 0.0001) had a significant relationship with SPHEQ. Conclusions. These data indicated that in children the posterior ciliary muscle fibers are thicker in myopia (CMT2 and CMT3), but paradoxically, the apical ciliary muscle fibers are thicker in hyperopia (CMTMAX and CMT1). This may be the first evidence that hyperopia is associated with a thicker apical ciliary muscle region.
- 1 July 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (7) , 4710-4716
Open AccessRegion-Specific Relationships Between Refractive Error and Ciliary Muscle Thickness in Children
Purpose. To determine if there is a relationship between refractive error and ciliary muscle thickness in different muscle regions. Methods. An anterior segment optical coherence tomographer was used to measure cycloplegic ciliary muscle thicknesses at 1 mm (CMT1), 2 mm (CMT2), and 3 mm (CMT3) posterior to the scleral spur; maximum (CMTMAX) thickness was also assessed. An autorefractor was used to determine cycloplegic spherical equivalent refractive error (SPHEQ). Apical ciliary muscle fibers were obtained by subtracting corresponding CMT2 values from CMT1 and CMTMAX. Multilevel regression models were used to determine the relationship between ciliary muscle thickness in various regions of the muscle and refractive error. Results. Subjects included 269 children with a mean age of 8.71 ± 1.51 years and a mean refractive error of +0.41 ± 1.29 diopters. In linear models with ciliary muscle thicknesses and SPHEQ, SPHEQ was significantly associated only with CMT2 (β = −11.34, P = 0.0008) and CMT 3 (β = −6.97, P = 0.007). When corresponding values of CMT2 were subtracted from CMT1 and CMTMAX, apical fibers at CMT1 (β = 14.75, P < 0.0001) and CMTMAX (β = 18.16, P < 0.0001) had a significant relationship with SPHEQ. Conclusions. These data indicated that in children the posterior ciliary muscle fibers are thicker in myopia (CMT2 and CMT3), but paradoxically, the apical ciliary muscle fibers are thicker in hyperopia (CMTMAX and CMT1). This may be the first evidence that hyperopia is associated with a thicker apical ciliary muscle region.
- 1 May 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (5) , 727-737
Changes in Ciliary Muscle Thickness During Accommodation in Children
Purpose.: To investigate the morphology of the ciliary muscle during the act of accommodation in a population of children. Methods.: Thirty children aged 6 to 12 years were enrolled. Accommodative response was measured through habitual correction. Height was measured as a control variable. Central axial length was measured with the IOLMaster. Four images of the temporal ciliary muscle were taken with the Visante Optical Coherence Tomographer at three different stimulus levels (0, 4, and 6 D) while accommodative response was monitored concurrently with the PowerRefractor. Accommodative response monitoring was time‐matched to ciliary muscle image capture, and the mean was calculated for 5 s surrounding this time point. Four cycloplegic images of the temporal ciliary muscle were also taken. Ciliary muscle thickness measurements were made at the point of maximum thickness (CMTMAX) and at 1 mm (CMT1), 2 mm (CMT2) and 3 mm (CMT3) posterior to the sclera spur. Results.: Increasing accommodative response was correlated with increases in the thickness of CMTMAX (p = <0.001) and CMT1 (p = <0.001) and decreases in the thickness of CMT3 (p = <0.001). Thicker values of CMTMAX under cycloplegic conditions were significantly correlated with values of CMTMAX (p = <0.001) and CMT1 (p = 0.001) while accommodating and approached significance in modeling CMT3 (p = 0.06). Mean axial length was correlated with the amount of thinning at CMT3 with accommodation (p = 0.002). Axial length was not significantly correlated with thickness values at CMTMAX (p = 0.7) or CMT1 (p = 0.6). Conclusions.: In a manner similar to previous adult studies, ciliary muscle thickness at CMTMAX and CMT1 increased with accommodation and CMT3 thinned with accommodation. Further investigation is necessary to determine whether CMT2 is a “fulcrum” point along the length of the ciliary muscle where the net change with accommodation is always zero or whether that point varies across subjects or with varying levels of accommodative effort.
- 1 May 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (5) , 727-737
Changes in Ciliary Muscle Thickness During Accommodation in Children
Purpose.: To investigate the morphology of the ciliary muscle during the act of accommodation in a population of children. Methods.: Thirty children aged 6 to 12 years were enrolled. Accommodative response was measured through habitual correction. Height was measured as a control variable. Central axial length was measured with the IOLMaster. Four images of the temporal ciliary muscle were taken with the Visante Optical Coherence Tomographer at three different stimulus levels (0, 4, and 6 D) while accommodative response was monitored concurrently with the PowerRefractor. Accommodative response monitoring was time‐matched to ciliary muscle image capture, and the mean was calculated for 5 s surrounding this time point. Four cycloplegic images of the temporal ciliary muscle were also taken. Ciliary muscle thickness measurements were made at the point of maximum thickness (CMTMAX) and at 1 mm (CMT1), 2 mm (CMT2) and 3 mm (CMT3) posterior to the sclera spur. Results.: Increasing accommodative response was correlated with increases in the thickness of CMTMAX (p = <0.001) and CMT1 (p = <0.001) and decreases in the thickness of CMT3 (p = <0.001). Thicker values of CMTMAX under cycloplegic conditions were significantly correlated with values of CMTMAX (p = <0.001) and CMT1 (p = 0.001) while accommodating and approached significance in modeling CMT3 (p = 0.06). Mean axial length was correlated with the amount of thinning at CMT3 with accommodation (p = 0.002). Axial length was not significantly correlated with thickness values at CMTMAX (p = 0.7) or CMT1 (p = 0.6). Conclusions.: In a manner similar to previous adult studies, ciliary muscle thickness at CMTMAX and CMT1 increased with accommodation and CMT3 thinned with accommodation. Further investigation is necessary to determine whether CMT2 is a “fulcrum” point along the length of the ciliary muscle where the net change with accommodation is always zero or whether that point varies across subjects or with varying levels of accommodative effort.
- 1 May 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (5) , 719-726
Measuring Changes in Ciliary Muscle Thickness with Accommodation in Young Adults
Purpose.: To develop a measurement protocol for changes in the shape and size of the ciliary muscle with accommodation using the Zeiss Visante™ anterior segment optical coherence tomography (AS‐OCT) and to determine the test‐retest repeatability of these measurements. Methods.: Subjects were 25 adults aged 23 to 28 years. The ciliary muscle was imaged at two visits with the Visante™ while accommodative response was monitored during imaging using the PowerRefractor. Ciliary muscle thickness (CMT) was measured at 1 mm (CMT1), 2 mm (CMT2), and 3 mm (CMT3) posterior to the scleral spur and at the point of maximal thickness (CMTMAX). Thickness was measured at these locations while subjects viewed a target at distance and at a 4.00 D accommodative stimulus. Outcome measures were the change in thickness between distance and the 4.00 D stimulus and the change in thickness per diopter of accommodative response (PowerRefractor). Finally, the repeatability measurements between visit 1 and visit 2 were determined with a Bland‐Altman analysis. Results.: The statistically significant modeled changes in CMT were as follows: CMTMAX = 69.2 μm (4.00 D stimulus) and 18.1 μm (per diopter of accommodation); CMT1 = 45.2 μm (4.00 D stimulus) and 12.3 μm (per diopter of accommodation); and CMT3 = −45.9 μm (4.00 D stimulus) and −12.0 μm (per diopter of accommodation); p < 0.0001 for all. Conclusions.: The combination of the Visante™ and the PowerRefractor is a feasible tool for measuring thickening of ciliary muscle at more anterior locations and thinning at more posterior locations during accommodation. We noted a wide range of accommodative responses during the time of image capture in this study indicating that the most accurate estimates of the change in ciliary muscle dimensions with accommodation may be obtained by using accommodative response rather than stimulus values and by using measurements taken simultaneously with image capture.
- 1 May 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (5) , 719-726
Measuring Changes in Ciliary Muscle Thickness with Accommodation in Young Adults
Purpose.: To develop a measurement protocol for changes in the shape and size of the ciliary muscle with accommodation using the Zeiss Visante™ anterior segment optical coherence tomography (AS‐OCT) and to determine the test‐retest repeatability of these measurements. Methods.: Subjects were 25 adults aged 23 to 28 years. The ciliary muscle was imaged at two visits with the Visante™ while accommodative response was monitored during imaging using the PowerRefractor. Ciliary muscle thickness (CMT) was measured at 1 mm (CMT1), 2 mm (CMT2), and 3 mm (CMT3) posterior to the scleral spur and at the point of maximal thickness (CMTMAX). Thickness was measured at these locations while subjects viewed a target at distance and at a 4.00 D accommodative stimulus. Outcome measures were the change in thickness between distance and the 4.00 D stimulus and the change in thickness per diopter of accommodative response (PowerRefractor). Finally, the repeatability measurements between visit 1 and visit 2 were determined with a Bland‐Altman analysis. Results.: The statistically significant modeled changes in CMT were as follows: CMTMAX = 69.2 μm (4.00 D stimulus) and 18.1 μm (per diopter of accommodation); CMT1 = 45.2 μm (4.00 D stimulus) and 12.3 μm (per diopter of accommodation); and CMT3 = −45.9 μm (4.00 D stimulus) and −12.0 μm (per diopter of accommodation); p < 0.0001 for all. Conclusions.: The combination of the Visante™ and the PowerRefractor is a feasible tool for measuring thickening of ciliary muscle at more anterior locations and thinning at more posterior locations during accommodation. We noted a wide range of accommodative responses during the time of image capture in this study indicating that the most accurate estimates of the change in ciliary muscle dimensions with accommodation may be obtained by using accommodative response rather than stimulus values and by using measurements taken simultaneously with image capture.
- 1 February 2011
- Published by Wiley in Optometry and Vision Science
- Vol. 88 (2) , 275-289
Semiautomatic Extraction Algorithm for Images of the Ciliary Muscle
Purpose.: To develop and evaluate a semiautomatic algorithm for segmentation and morphological assessment of the dimensions of the ciliary muscle in Visante Anterior Segment Optical Coherence Tomography images. Methods.: Geometric distortions in Visante images analyzed as binary files were assessed by imaging an optical flat and human donor tissue. The appropriate pixel/mm conversion factor to use for air (n = 1) was estimated by imaging calibration spheres. A semiautomatic algorithm was developed to extract the dimensions of the ciliary muscle from Visante images. Measurements were also made manually using Visante software calipers. Interclass correlation coefficients and Bland‐Altman analyses were used to compare the methods. A multilevel model was fitted to estimate the variance of algorithm measurements that was due to differences within‐ and between‐examiners in scleral spur selection vs. biological variability. Results.: The optical flat and the human donor tissue were imaged and appeared without geometric distortions in binary file format. Bland‐Altman analyses revealed that caliper measurements tended to underestimate ciliary muscle thickness at 3 mm posterior to the scleral spur in subjects with the thickest ciliary muscles (t = 3.6, p < 0.001). The percent variance due to within‐ or between‐examiner differences in scleral spur selection was found to be small (6%) when compared with the variance because of biological difference across subjects (80%). Using the mean of measurements from three images, achieved an estimated interclass correlation coefficient of 0.85. Conclusions.: The semiautomatic algorithm successfully segmented the ciliary muscle for further measurement. Using the algorithm to follow the scleral curvature to locate more posterior measurements is critical to avoid underestimating thickness measurements. This semiautomatic algorithm will allow for repeatable, efficient, and masked ciliary muscle measurements in large datasets.
- 1 February 2011
- Published by Wiley in Optometry and Vision Science
- Vol. 88 (2) , 275-289
Semiautomatic Extraction Algorithm for Images of the Ciliary Muscle
Purpose.: To develop and evaluate a semiautomatic algorithm for segmentation and morphological assessment of the dimensions of the ciliary muscle in Visante Anterior Segment Optical Coherence Tomography images. Methods.: Geometric distortions in Visante images analyzed as binary files were assessed by imaging an optical flat and human donor tissue. The appropriate pixel/mm conversion factor to use for air (n = 1) was estimated by imaging calibration spheres. A semiautomatic algorithm was developed to extract the dimensions of the ciliary muscle from Visante images. Measurements were also made manually using Visante software calipers. Interclass correlation coefficients and Bland‐Altman analyses were used to compare the methods. A multilevel model was fitted to estimate the variance of algorithm measurements that was due to differences within‐ and between‐examiners in scleral spur selection vs. biological variability. Results.: The optical flat and the human donor tissue were imaged and appeared without geometric distortions in binary file format. Bland‐Altman analyses revealed that caliper measurements tended to underestimate ciliary muscle thickness at 3 mm posterior to the scleral spur in subjects with the thickest ciliary muscles (t = 3.6, p < 0.001). The percent variance due to within‐ or between‐examiner differences in scleral spur selection was found to be small (6%) when compared with the variance because of biological difference across subjects (80%). Using the mean of measurements from three images, achieved an estimated interclass correlation coefficient of 0.85. Conclusions.: The semiautomatic algorithm successfully segmented the ciliary muscle for further measurement. Using the algorithm to follow the scleral curvature to locate more posterior measurements is critical to avoid underestimating thickness measurements. This semiautomatic algorithm will allow for repeatable, efficient, and masked ciliary muscle measurements in large datasets.
- Open Access
- 1 October 2008
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 49 (10) , 4353-4360
Ciliary Body Thickness and Refractive Error in Children
Purpose. To determine whether ciliary body thickness (CBT) is related to refractive error in school-age children. methods. Fifty-three children, 8 to 15 years of age, were recruited. CBT was measured from anterior segment OCT images (Visante; Carl Zeiss Meditec, Inc., Dublin, CA) at 1 (CBT1), 2 (CBT2) and 3 (CBT3) mm posterior to the scleral spur. Cycloplegic refractive error was measured with an autorefractor, and axial length was measured with an optical biometer. Multilevel regression models determined the relationship between CBT measurements and refractive error or axial length. A Bland-Altman analysis was used to assess the between-visit repeatability of the ciliary body measurements. results. The between-visits coefficients of repeatability for CBT1, -2, and -3 were 148.04, 165.68, and 110.90, respectively. Thicker measurements at CBT2 (r = −0.29, P = 0.03) and CBT3 (r = −0.38, P = 0.005) were associated with increasingly myopic refractive errors (multilevel model: P < 0.001). Thicker measurements at CBT2 (r = 0.40, P = 0.003) and CBT3 (r = 0.51, P < 0.001) were associated with longer axial lengths (multilevel model: P < 0.001). conclusions. Thicker ciliary body measurements were associated with myopia and a longer axial length. Future studies should determine whether this relationship is also present in animal models of myopia and determine the temporal relationship between thickening of the ciliary muscle and the onset of myopia.
- 1 October 2008
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 49 (10) , 4353-4360
Open AccessCiliary Body Thickness and Refractive Error in Children
Purpose. To determine whether ciliary body thickness (CBT) is related to refractive error in school-age children. methods. Fifty-three children, 8 to 15 years of age, were recruited. CBT was measured from anterior segment OCT images (Visante; Carl Zeiss Meditec, Inc., Dublin, CA) at 1 (CBT1), 2 (CBT2) and 3 (CBT3) mm posterior to the scleral spur. Cycloplegic refractive error was measured with an autorefractor, and axial length was measured with an optical biometer. Multilevel regression models determined the relationship between CBT measurements and refractive error or axial length. A Bland-Altman analysis was used to assess the between-visit repeatability of the ciliary body measurements. results. The between-visits coefficients of repeatability for CBT1, -2, and -3 were 148.04, 165.68, and 110.90, respectively. Thicker measurements at CBT2 (r = −0.29, P = 0.03) and CBT3 (r = −0.38, P = 0.005) were associated with increasingly myopic refractive errors (multilevel model: P < 0.001). Thicker measurements at CBT2 (r = 0.40, P = 0.003) and CBT3 (r = 0.51, P < 0.001) were associated with longer axial lengths (multilevel model: P < 0.001). conclusions. Thicker ciliary body measurements were associated with myopia and a longer axial length. Future studies should determine whether this relationship is also present in animal models of myopia and determine the temporal relationship between thickening of the ciliary muscle and the onset of myopia.
- 1 April 2007
- Published by Wolters Kluwer Health in Cornea
- Vol. 26 (3) , 246-254
Outcomes of LASIK for Myopia With FDA-Approved Lasers
To report expected outcomes of laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism from existing US Food and Drug Administration (FDA) data. Data from Summaries of Safety and Effectiveness for each of the 12 lasers approved by the FDA for LASIK for myopia or myopic astigmatism between 1998 and 2004 were recorded from the FDA Web site. The Cochran-Armitage test for trend was used to determine whether improvements in outcomes occurred with laser technology changes. For all patients, there was a statistically significant trend toward improvement with improved laser technology in the proportion of patients with uncorrected visual acuity (UCVA) of 20/20 or better, UCVA of 20/40 or better, results within +/-0.50 D of intended correction, results within +/-1.00 D of the intended correction, and night vision symptoms (all P < 0.0002). Because there were preoperative differences across laser types, subgroup analyses were also completed. The results for subgroup analyses (high myopia, low to moderate myopia, spherical myopia, and myopic astigmatism) for visual acuity and refractive error outcomes were similar to results for analyses for all groups combined. Conversely, there was no difference across laser types in the proportion of patients who experienced dry eye symptoms or for the proportion of patients with low to moderate myopia who experienced night vision symptoms that were worse or significantly worse than before LASIK. LASIK provides excellent visual acuity and refractive error outcomes. Night vision and dryness symptoms still occur in a significant proportion of patients. Future studies should seek to determine whether additional changes in technology, patient selection criteria, or postoperative treatment could reduce or eliminate these symptoms.
- 1 April 2007
- Published by Wolters Kluwer Health in Cornea
- Vol. 26 (3) , 246-254
Outcomes of LASIK for Myopia With FDA-Approved Lasers
To report expected outcomes of laser in situ keratomileusis (LASIK) for myopia and myopic astigmatism from existing US Food and Drug Administration (FDA) data. Data from Summaries of Safety and Effectiveness for each of the 12 lasers approved by the FDA for LASIK for myopia or myopic astigmatism between 1998 and 2004 were recorded from the FDA Web site. The Cochran-Armitage test for trend was used to determine whether improvements in outcomes occurred with laser technology changes. For all patients, there was a statistically significant trend toward improvement with improved laser technology in the proportion of patients with uncorrected visual acuity (UCVA) of 20/20 or better, UCVA of 20/40 or better, results within +/-0.50 D of intended correction, results within +/-1.00 D of the intended correction, and night vision symptoms (all P < 0.0002). Because there were preoperative differences across laser types, subgroup analyses were also completed. The results for subgroup analyses (high myopia, low to moderate myopia, spherical myopia, and myopic astigmatism) for visual acuity and refractive error outcomes were similar to results for analyses for all groups combined. Conversely, there was no difference across laser types in the proportion of patients who experienced dry eye symptoms or for the proportion of patients with low to moderate myopia who experienced night vision symptoms that were worse or significantly worse than before LASIK. LASIK provides excellent visual acuity and refractive error outcomes. Night vision and dryness symptoms still occur in a significant proportion of patients. Future studies should seek to determine whether additional changes in technology, patient selection criteria, or postoperative treatment could reduce or eliminate these symptoms.
- 1 May 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (5) , 1025-1034
Repeatability of autorefraction and axial length measurements after laser in situ keratomileusis
To assess the repeatability and agreement of refractive error measurements and the repeatability of axial length (AL) measurements in patients after laser in situ keratomileusis (LASIK). The Ohio State University College of Optometry, Columbus, Ohio, USA. Subjective refraction, autorefraction measurements with the Grand Seiko and Humphrey autorefractors, and AL measurements with the IOLMaster were completed for 40 previously myopic LASIK patients under noncycloplegic and cycloplegic conditions on 2 separate occasions. The mean difference between visits for axial length measurements was 0.008 mm +/- 0.04 (SD). The between visits repeatability for all refractive error measurements were <0.75 diopter (D). The mean difference between the subjective refraction and the Humphrey autorefractor for spherical equivalent was statistically significant under noncycloplegic conditions (-0.90 D, P<.0001) and cycloplegic conditions (-2.05 D, P<.0001). The mean difference between subjective refraction and Grand Seiko autorefraction measurements was not significant under noncycloplegic conditions (+0.05 D, 95% limits of agreement [LoA]=-0.99, 1.09; P=.52) conditions but was statistically significant, but not clinically relevant, under cycloplegic conditions (+0.17 D, 95% LoA=-0.73, 1.07; P=.03). Refractive error measurements after LASIK using the Grand Seiko autorefractor are reliable and agree well with subjective refraction measurements.
- 1 May 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (5) , 1025-1034
Repeatability of autorefraction and axial length measurements after laser in situ keratomileusis
To assess the repeatability and agreement of refractive error measurements and the repeatability of axial length (AL) measurements in patients after laser in situ keratomileusis (LASIK). The Ohio State University College of Optometry, Columbus, Ohio, USA. Subjective refraction, autorefraction measurements with the Grand Seiko and Humphrey autorefractors, and AL measurements with the IOLMaster were completed for 40 previously myopic LASIK patients under noncycloplegic and cycloplegic conditions on 2 separate occasions. The mean difference between visits for axial length measurements was 0.008 mm +/- 0.04 (SD). The between visits repeatability for all refractive error measurements were <0.75 diopter (D). The mean difference between the subjective refraction and the Humphrey autorefractor for spherical equivalent was statistically significant under noncycloplegic conditions (-0.90 D, P<.0001) and cycloplegic conditions (-2.05 D, P<.0001). The mean difference between subjective refraction and Grand Seiko autorefraction measurements was not significant under noncycloplegic conditions (+0.05 D, 95% limits of agreement [LoA]=-0.99, 1.09; P=.52) conditions but was statistically significant, but not clinically relevant, under cycloplegic conditions (+0.17 D, 95% LoA=-0.73, 1.07; P=.03). Refractive error measurements after LASIK using the Grand Seiko autorefractor are reliable and agree well with subjective refraction measurements.
- 1 September 2004
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (9) , 1861-1866
Reasons patients recommend laser in situ keratomileusis
To evaluate the reasons patients who have had laser in situ keratomileusis (LASIK) recommend it to others and examine the disparity between high levels of satisfaction and patient reports of night-vision symptoms and/or dry eye after LASIK. Northeastern Eye Institute, Scranton, and the University of Pittsburgh, Pittsburgh, Pennsylvania, and the University of California at Los Angeles, Los Angeles, California, USA. Questionnaires assessing symptoms and satisfaction after LASIK were mailed to 2,100 patients. The questionnaires included items about night-vision symptoms and satisfaction and an open-ended question for patients to give their reasons for recommending LASIK to others. The open-ended responses were categorized and tabulated. Four hundred thirty-four patients provided reasons for recommending LASIK to others. Sixteen categories of reasons were identified. "No more spectacles/contact lenses" was listed by 180 patients (42%), followed by "better vision" (21%) and "convenience" (15%). Women were significantly more likely to cite "better comfort" (27 women versus 3 men; chi square = 8.99, P =.003) and "better quality of life" (41 women versus 9 men; chi square = 7.36, P =.007) as a reason for recommending LASIK. Of the 35 patients who reported dissatisfaction with post-LASIK vision, 20 (57%) would recommend LASIK to a friend because "LASIK helps others." Categories of reasons for recommending LASIK to others were similar to reasons given by patients for seeking LASIK. Some patients who reported dissatisfaction with their vision said they would recommend LASIK, suggesting that recommendation of LASIK to others is not necessarily a measurement of the quality of a patient's vision after LASIK.
- 1 September 2004
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (9) , 1861-1866
Reasons patients recommend laser in situ keratomileusis
To evaluate the reasons patients who have had laser in situ keratomileusis (LASIK) recommend it to others and examine the disparity between high levels of satisfaction and patient reports of night-vision symptoms and/or dry eye after LASIK. Northeastern Eye Institute, Scranton, and the University of Pittsburgh, Pittsburgh, Pennsylvania, and the University of California at Los Angeles, Los Angeles, California, USA. Questionnaires assessing symptoms and satisfaction after LASIK were mailed to 2,100 patients. The questionnaires included items about night-vision symptoms and satisfaction and an open-ended question for patients to give their reasons for recommending LASIK to others. The open-ended responses were categorized and tabulated. Four hundred thirty-four patients provided reasons for recommending LASIK to others. Sixteen categories of reasons were identified. "No more spectacles/contact lenses" was listed by 180 patients (42%), followed by "better vision" (21%) and "convenience" (15%). Women were significantly more likely to cite "better comfort" (27 women versus 3 men; chi square = 8.99, P =.003) and "better quality of life" (41 women versus 9 men; chi square = 7.36, P =.007) as a reason for recommending LASIK. Of the 35 patients who reported dissatisfaction with post-LASIK vision, 20 (57%) would recommend LASIK to a friend because "LASIK helps others." Categories of reasons for recommending LASIK to others were similar to reasons given by patients for seeking LASIK. Some patients who reported dissatisfaction with their vision said they would recommend LASIK, suggesting that recommendation of LASIK to others is not necessarily a measurement of the quality of a patient's vision after LASIK.
- 1 July 2003
- Published by Elsevier in Ophthalmology
- Vol. 110 (7) , 1371-1378
Patient satisfaction and visual symptoms after laser in situ keratomileusis
- 1 July 2003
- Published by Elsevier in Ophthalmology
- Vol. 110 (7) , 1371-1378
Patient satisfaction and visual symptoms after laser in situ keratomileusis