Annette Robichaud
Research Subjects
Annette Robichaud has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Liah Fereydoonzad
SCIREQ Inc., Montreal, Quebec, Canada
4 shared publicationsJames G. Martin
Meakins-Christie Laboratories, Research Institute of the McGill University Health Centre, Montreal, Quebec, Canada
3 shared publicationsThomas F. Schuessler
SCIREQ Scientific Respiratory Equipment, Inc., Montreal, Quebec, Canada
2 shared publicationsWayne Mitzner
Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, Maryland
2 shared publicationsAndrea Benedetti
Meakins-Christie Laboratories, Department of Medicine, McGill University and the Research Institute of the McGill University Health Centre, Montreal, Quebec, Canada
1 shared publication- Benoit Allard
Université de La Réunion, INSERM, UMR 1188 Diabète athérothrombose Thérapies Réunion Océan Indien (DéTROI)
1 shared publication
Latest Publications
- 1 June 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 320 (6) , L1038-L1056
Oscillometry of the respiratory system: a translational opportunity not to be missed
Airway oscillometry has become the de facto standard for quality assessment of lung physiology in laboratory animals and has demonstrated its usefulness in understanding diseases of small airways. Nowadays, it is seeing extensive use in daily clinical practice and research; however, a question that remains unanswered is how well physiological findings in animals and humans correlate? Methodological and device differences are obvious between animal and human studies. However, all devices deliver an oscillated airflow test signal and output respiratory impedance. In addition, despite analysis differences, there are ways to interpret animal and human oscillometry data to allow suitable comparisons. The potential with oscillometry is its ability to reveal universal features of the respiratory system across species, making translational extrapolation likely to be predictive. This means that oscillometry can thus help determine if an animal model displays the same physiological characteristics as the human disease. Perhaps more importantly, it can also be useful to determine whether an intervention is effective as well as to understand if it affects the desired region of the respiratory system, e.g., the periphery of the lung. Finally, findings in humans can also inform preclinical scientists and give indications as to what type of physiological changes should be observed in animal models to make them relevant as models of human disease. The present article will attempt to demonstrate the potential of oscillometry in respiratory research, an area where the development of novel therapies is plagued with a failure rate higher than in other disease areas.
- 1 June 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 320 (6) , L1038-L1056
Oscillometry of the respiratory system: a translational opportunity not to be missed
Airway oscillometry has become the de facto standard for quality assessment of lung physiology in laboratory animals and has demonstrated its usefulness in understanding diseases of small airways. Nowadays, it is seeing extensive use in daily clinical practice and research; however, a question that remains unanswered is how well physiological findings in animals and humans correlate? Methodological and device differences are obvious between animal and human studies. However, all devices deliver an oscillated airflow test signal and output respiratory impedance. In addition, despite analysis differences, there are ways to interpret animal and human oscillometry data to allow suitable comparisons. The potential with oscillometry is its ability to reveal universal features of the respiratory system across species, making translational extrapolation likely to be predictive. This means that oscillometry can thus help determine if an animal model displays the same physiological characteristics as the human disease. Perhaps more importantly, it can also be useful to determine whether an intervention is effective as well as to understand if it affects the desired region of the respiratory system, e.g., the periphery of the lung. Finally, findings in humans can also inform preclinical scientists and give indications as to what type of physiological changes should be observed in animal models to make them relevant as models of human disease. The present article will attempt to demonstrate the potential of oscillometry in respiratory research, an area where the development of novel therapies is plagued with a failure rate higher than in other disease areas.
- 19 May 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 321 (1) , L204-L212
Airway compliance measurements in mouse models of respiratory diseases
The quantification of airway compliance ( Caw) is essential to the study of airway alterations in disease models. However, the required measurements of airway pressure and volume are difficult to acquire in mice. We hypothesized that the inflation limb of full-range pressure-volume (PV) curves could be used to quantify Caw, as it contains a segment where only the airway tree is distended. The study objective was to assess the feasibility of the approach by analysis of full-range PV curves previously collected in three mouse models: an elastase model of emphysema, a genetic model spontaneously developing emphysema (leukotriene C4 synthase knockout; LTC4S-KO), and a bleomycin model of lung fibrosis. Attempts to validate results included Caw change relative to respiratory system compliance (Δ Caw/Δ C), the minute work of breathing (mWOB), and the elastance at 20.5 Hz ( Ers_20.5) from prior respiratory mechanics measurements in the same subjects. Caw was estimated at 3% of total compliance in healthy mice or 2.3 ± 1 μL/cmH2O ( n = 17). The technique detected changes in models of respiratory obstructive and restrictive diseases relative to control mice as well as differences in the two emphysema models studied. The changes in Caw were consistent with those seen in Δ Caw/Δ C, mWOB, or Ers_20.5, with some variations according to the model, as well as with results reported in the literature in humans and mice. Direct Caw measurements in subjects as small as mice could prove useful to further characterize other respiratory disease models associated with airway remodeling or to assess treatment effects.
- 19 May 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 321 (1) , L204-L212
Airway compliance measurements in mouse models of respiratory diseases
The quantification of airway compliance ( Caw) is essential to the study of airway alterations in disease models. However, the required measurements of airway pressure and volume are difficult to acquire in mice. We hypothesized that the inflation limb of full-range pressure-volume (PV) curves could be used to quantify Caw, as it contains a segment where only the airway tree is distended. The study objective was to assess the feasibility of the approach by analysis of full-range PV curves previously collected in three mouse models: an elastase model of emphysema, a genetic model spontaneously developing emphysema (leukotriene C4 synthase knockout; LTC4S-KO), and a bleomycin model of lung fibrosis. Attempts to validate results included Caw change relative to respiratory system compliance (Δ Caw/Δ C), the minute work of breathing (mWOB), and the elastance at 20.5 Hz ( Ers_20.5) from prior respiratory mechanics measurements in the same subjects. Caw was estimated at 3% of total compliance in healthy mice or 2.3 ± 1 μL/cmH2O ( n = 17). The technique detected changes in models of respiratory obstructive and restrictive diseases relative to control mice as well as differences in the two emphysema models studied. The changes in Caw were consistent with those seen in Δ Caw/Δ C, mWOB, or Ers_20.5, with some variations according to the model, as well as with results reported in the literature in humans and mice. Direct Caw measurements in subjects as small as mice could prove useful to further characterize other respiratory disease models associated with airway remodeling or to assess treatment effects.
- Open Access
- 10 July 2018
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 137,p. e57778
Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Air volume changes created by a conscious subject breathing spontaneously within a body box are at the basis of plethysmography, a technique used to non-invasively assess some features of the respiratory function in humans as well as in laboratory animals. The present article focuses on the application of the double-chamber plethysmography (DCP) in small animals. It provides background information on the methodology as well as a detailed step-by-step procedure to successfully assess respiratory function in conscious, spontaneously breathing animals in a non-invasive manner. The DCP can be used to monitor the respiratory function of multiple animals in parallel, as well as to identify changes induced by aerosolized substances over a chosen time period and in a repeated manner. Experiments on control and allergic mice are used herein to demonstrate the utility of the technique, explain the associated outcome parameters, as well as to discuss the related advantages and shortcomings. Overall, the DCP provides valid and theoretically sound readouts that can be trusted to evaluate the respiratory function of conscious small animals both at baseline and after challenges with aerosolized substances.
- 10 July 2018
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 137,p. e57778
Open AccessAssessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Air volume changes created by a conscious subject breathing spontaneously within a body box are at the basis of plethysmography, a technique used to non-invasively assess some features of the respiratory function in humans as well as in laboratory animals. The present article focuses on the application of the double-chamber plethysmography (DCP) in small animals. It provides background information on the methodology as well as a detailed step-by-step procedure to successfully assess respiratory function in conscious, spontaneously breathing animals in a non-invasive manner. The DCP can be used to monitor the respiratory function of multiple animals in parallel, as well as to identify changes induced by aerosolized substances over a chosen time period and in a repeated manner. Experiments on control and allergic mice are used herein to demonstrate the utility of the technique, explain the associated outcome parameters, as well as to discuss the related advantages and shortcomings. Overall, the DCP provides valid and theoretically sound readouts that can be trusted to evaluate the respiratory function of conscious small animals both at baseline and after challenges with aerosolized substances.
- 1 October 2017
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 123 (4) , 746-756
Automated full-range pressure-volume curves in mice and rats
Pressure-volume (PV) curves constructed over the entire lung volume range can reliably detect functional changes in mouse models of lung diseases. In the present study, we constructed full-range PV curves in healthy and elastase-treated mice using either a classic manually operated technique or an automated approach using a computer-controlled piston ventilator [flexiVent FX; Scientific Respiratory Equipment (SCIREQ), Montreal, Quebec, Canada]. On the day of the experiment, subjects were anesthetized, tracheotomized, and mechanically ventilated. Following an initial respiratory mechanics scan and degassing of the lungs with 100% O2, full-range PV curves were constructed using either the classic or the automated technique. In control mice, superimposable curves were obtained, and statistical equivalence was attained between the two methodologies. In the elastase-treated ones, where significant changes in respiratory mechanics and lung volumes were expected, very small differences were observed between the two techniques, and the criteria for statistical equivalence were met in two out of four parameters assessed. The automated technique was adapted to rats and used to estimate the functional residual capacity (FRC) by volume subtraction. This novel approach generated FRC estimates consistent with the literature, with added accuracy relative to the existing method in diseased subjects. In conclusion, the automated technique generated full-range PV curves that were equivalent or very close to those obtained with the classic method under physiological or severe pathological conditions. The automation facilitated some technical aspects of the procedure, eased its use across species, and helped derive a more accurate estimate of FRC in preclinical models of respiratory disease.NEW & NOTEWORTHY Partial and full-range pressure-volume (PV) curves are frequently used to characterize lung disease models. Whereas automated techniques exist to construct partial PV curves, a manually operated approach is classically employed to build the full-range ones. In this study, the full-range PV curve technique was automated using a computer-controlled piston ventilator. The automation simplified the technique, facilitated its extension to other species, and inspired a novel way of estimating the functional residual capacity in laboratory rodents.
- 1 October 2017
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 123 (4) , 746-756
Automated full-range pressure-volume curves in mice and rats
Pressure-volume (PV) curves constructed over the entire lung volume range can reliably detect functional changes in mouse models of lung diseases. In the present study, we constructed full-range PV curves in healthy and elastase-treated mice using either a classic manually operated technique or an automated approach using a computer-controlled piston ventilator [flexiVent FX; Scientific Respiratory Equipment (SCIREQ), Montreal, Quebec, Canada]. On the day of the experiment, subjects were anesthetized, tracheotomized, and mechanically ventilated. Following an initial respiratory mechanics scan and degassing of the lungs with 100% O2, full-range PV curves were constructed using either the classic or the automated technique. In control mice, superimposable curves were obtained, and statistical equivalence was attained between the two methodologies. In the elastase-treated ones, where significant changes in respiratory mechanics and lung volumes were expected, very small differences were observed between the two techniques, and the criteria for statistical equivalence were met in two out of four parameters assessed. The automated technique was adapted to rats and used to estimate the functional residual capacity (FRC) by volume subtraction. This novel approach generated FRC estimates consistent with the literature, with added accuracy relative to the existing method in diseased subjects. In conclusion, the automated technique generated full-range PV curves that were equivalent or very close to those obtained with the classic method under physiological or severe pathological conditions. The automation facilitated some technical aspects of the procedure, eased its use across species, and helped derive a more accurate estimate of FRC in preclinical models of respiratory disease.NEW & NOTEWORTHY Partial and full-range pressure-volume (PV) curves are frequently used to characterize lung disease models. Whereas automated techniques exist to construct partial PV curves, a manually operated approach is classically employed to build the full-range ones. In this study, the full-range PV curve technique was automated using a computer-controlled piston ventilator. The automation simplified the technique, facilitated its extension to other species, and inspired a novel way of estimating the functional residual capacity in laboratory rodents.
- 15 April 2015
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 308 (8) , L837-L846
Delivered dose estimate to standardize airway hyperresponsiveness assessment in mice
Airway hyperresponsiveness often constitutes a primary outcome in respiratory studies in mice. The procedure commonly employs aerosolized challenges, and results are typically reported in terms of bronchoconstrictor concentrations loaded into the nebulizer. Yet, because protocols frequently differ across studies, especially in terms of aerosol generation and delivery, direct study comparisons are difficult. We hypothesized that protocol variations could lead to differences in aerosol delivery efficiency and, consequently, in the dose delivered to the subject, as well as in the response. Thirteen nebulization patterns containing common protocol variations (nebulization time, duty cycle, particle size spectrum, air humidity, and/or ventilation profile) and using increasing concentrations of methacholine and broadband forced oscillations (flexiVent, SCIREQ, Montreal, Qc, Canada) were created, characterized, and studied in anesthetized naïve A/J mice. A delivered dose estimate calculated from nebulizer-, ventilator-, and subject-specific characteristics was introduced and used to account for protocol variations. Results showed that nebulization protocol variations significantly affected the fraction of aerosol reaching the subject site and the delivered dose, as well as methacholine reactivity and sensitivity in mice. From the protocol variants studied, addition of a slow deep ventilation profile during nebulization was identified as a key factor for optimization of the technique. The study also highlighted sensitivity differences within the lung, as well as the possibility that airway responses could be selectively enhanced by adequate control of nebulizer and ventilator settings. Reporting results in terms of delivered doses represents an important standardizing element for assessment of airway hyperresponsiveness in mice.
- 15 April 2015
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 308 (8) , L837-L846
Delivered dose estimate to standardize airway hyperresponsiveness assessment in mice
Airway hyperresponsiveness often constitutes a primary outcome in respiratory studies in mice. The procedure commonly employs aerosolized challenges, and results are typically reported in terms of bronchoconstrictor concentrations loaded into the nebulizer. Yet, because protocols frequently differ across studies, especially in terms of aerosol generation and delivery, direct study comparisons are difficult. We hypothesized that protocol variations could lead to differences in aerosol delivery efficiency and, consequently, in the dose delivered to the subject, as well as in the response. Thirteen nebulization patterns containing common protocol variations (nebulization time, duty cycle, particle size spectrum, air humidity, and/or ventilation profile) and using increasing concentrations of methacholine and broadband forced oscillations (flexiVent, SCIREQ, Montreal, Qc, Canada) were created, characterized, and studied in anesthetized naïve A/J mice. A delivered dose estimate calculated from nebulizer-, ventilator-, and subject-specific characteristics was introduced and used to account for protocol variations. Results showed that nebulization protocol variations significantly affected the fraction of aerosol reaching the subject site and the delivered dose, as well as methacholine reactivity and sensitivity in mice. From the protocol variants studied, addition of a slow deep ventilation profile during nebulization was identified as a key factor for optimization of the technique. The study also highlighted sensitivity differences within the lung, as well as the possibility that airway responses could be selectively enhanced by adequate control of nebulizer and ventilator settings. Reporting results in terms of delivered doses represents an important standardizing element for assessment of airway hyperresponsiveness in mice.
- Open Access
- 15 May 2013
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 75,p. e50172
Evaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
The forced oscillation technique (FOT) is a powerful, integrative and translational tool permitting the experimental assessment of lung function in mice in a comprehensive, detailed, precise and reproducible manner. It provides measurements of respiratory system mechanics through the analysis of pressure and volume signals acquired in reaction to predefined, small amplitude, oscillatory airflow waveforms, which are typically applied at the subject's airway opening. The present protocol details the steps required to adequately execute forced oscillation measurements in mice using a computer-controlled piston ventilator (flexiVent; SCIREQ Inc, Montreal, Qc, Canada). The description is divided into four parts: preparatory steps, mechanical ventilation, lung function measurements, and data analysis. It also includes details of how to assess airway responsiveness to inhaled methacholine in anesthetized mice, a common application of this technique which also extends to other outcomes and various lung pathologies. Measurements obtained in naïve mice as well as from an oxidative-stress driven model of airway damage are presented to illustrate how this tool can contribute to a better characterization and understanding of studied physiological changes or disease models as well as to applications in new research areas.
- 15 May 2013
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 75,p. e50172
Open AccessEvaluation of Respiratory System Mechanics in Mice using the Forced Oscillation Technique
The forced oscillation technique (FOT) is a powerful, integrative and translational tool permitting the experimental assessment of lung function in mice in a comprehensive, detailed, precise and reproducible manner. It provides measurements of respiratory system mechanics through the analysis of pressure and volume signals acquired in reaction to predefined, small amplitude, oscillatory airflow waveforms, which are typically applied at the subject's airway opening. The present protocol details the steps required to adequately execute forced oscillation measurements in mice using a computer-controlled piston ventilator (flexiVent; SCIREQ Inc, Montreal, Qc, Canada). The description is divided into four parts: preparatory steps, mechanical ventilation, lung function measurements, and data analysis. It also includes details of how to assess airway responsiveness to inhaled methacholine in anesthetized mice, a common application of this technique which also extends to other outcomes and various lung pathologies. Measurements obtained in naïve mice as well as from an oxidative-stress driven model of airway damage are presented to illustrate how this tool can contribute to a better characterization and understanding of studied physiological changes or disease models as well as to applications in new research areas.
- Open Access
- 21 June 2010
- Published by Springer Nature in Respiratory Research
- Vol. 11 (1) , 82
Combined forced oscillation and forced expiration measurements in mice for the assessment of airway hyperresponsiveness
Pulmonary function has been reported in mice using negative pressure-driven forced expiratory manoeuvres (NPFE) and the forced oscillation technique (FOT). However, both techniques have always been studied using separate cohorts of animals or systems. The objective of this study was to obtain NPFE and FOT measurements at baseline and following bronchoconstriction from a single cohort of mice using a combined system in order to assess both techniques through a refined approach. Groups of allergen- or sham-challenged ovalbumin-sensitized mice that were either vehicle (saline) or drug (dexamethasone 1 mg/kg ip)-treated were studied. Surgically prepared animals were connected to an extended flexiVent system (SCIREQ Inc., Montreal, Canada) permitting NPFE and FOT measurements. Lung function was assessed concomitantly by both techniques at baseline and following doubling concentrations of aerosolized methacholine (MCh; 31.25 - 250 mg/ml). The effect of the NPFE manoeuvre on respiratory mechanics was also studied. The expected exaggerated MCh airway response of allergic mice and its inhibition by dexamethasone were detected by both techniques. We observed significant changes in FOT parameters at either the highest (Ers, H) or the two highest (Rrs, RN, G) MCh concentrations. The flow-volume (F-V) curves obtained following NPFE manoeuvres demonstrated similar MCh concentration-dependent changes. A dexamethasone-sensitive decrease in the area under the flow-volume curve at the highest MCh concentration was observed in the allergic mice. Two of the four NPFE parameters calculated from the F-V curves, FEV0.1 and FEF50, also captured the expected changes but only at the highest MCh concentration. Normalization to baseline improved the sensitivity of NPFE parameters at detecting the exaggerated MCh airway response of allergic mice but had minimal impact on FOT responses. Finally, the combination with FOT allowed us to demonstrate that NPFE induced persistent airway closure that was reversible by deep lung inflation. We conclude that FOT and NPFE can be concurrently assessed in the same cohort of animals to determine airway mechanics and expiratory flow limitation during methacholine responses, and that the combination of the two techniques offers a refined control and an improved reproducibility of the NPFE.
- 21 June 2010
- Published by Springer Nature in Respiratory Research
- Vol. 11 (1) , 82
Open AccessCombined forced oscillation and forced expiration measurements in mice for the assessment of airway hyperresponsiveness
Pulmonary function has been reported in mice using negative pressure-driven forced expiratory manoeuvres (NPFE) and the forced oscillation technique (FOT). However, both techniques have always been studied using separate cohorts of animals or systems. The objective of this study was to obtain NPFE and FOT measurements at baseline and following bronchoconstriction from a single cohort of mice using a combined system in order to assess both techniques through a refined approach. Groups of allergen- or sham-challenged ovalbumin-sensitized mice that were either vehicle (saline) or drug (dexamethasone 1 mg/kg ip)-treated were studied. Surgically prepared animals were connected to an extended flexiVent system (SCIREQ Inc., Montreal, Canada) permitting NPFE and FOT measurements. Lung function was assessed concomitantly by both techniques at baseline and following doubling concentrations of aerosolized methacholine (MCh; 31.25 - 250 mg/ml). The effect of the NPFE manoeuvre on respiratory mechanics was also studied. The expected exaggerated MCh airway response of allergic mice and its inhibition by dexamethasone were detected by both techniques. We observed significant changes in FOT parameters at either the highest (Ers, H) or the two highest (Rrs, RN, G) MCh concentrations. The flow-volume (F-V) curves obtained following NPFE manoeuvres demonstrated similar MCh concentration-dependent changes. A dexamethasone-sensitive decrease in the area under the flow-volume curve at the highest MCh concentration was observed in the allergic mice. Two of the four NPFE parameters calculated from the F-V curves, FEV0.1 and FEF50, also captured the expected changes but only at the highest MCh concentration. Normalization to baseline improved the sensitivity of NPFE parameters at detecting the exaggerated MCh airway response of allergic mice but had minimal impact on FOT responses. Finally, the combination with FOT allowed us to demonstrate that NPFE induced persistent airway closure that was reversible by deep lung inflation. We conclude that FOT and NPFE can be concurrently assessed in the same cohort of animals to determine airway mechanics and expiratory flow limitation during methacholine responses, and that the combination of the two techniques offers a refined control and an improved reproducibility of the NPFE.