PPPaola Pedotti

Paola Pedotti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paola Pedotti has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Relative power and sample size analysis on gene expression profiling data

    by M van Iterson, Pac 'T Hoen, P Pedotti, Gjej Hooiveld, Jt Den Dunnen, Gjb van Ommen, Jm Boer, Rx Menezes

    Background: With the increasing number of expression profiling technologies, researchers today are confronted with choosing the technology that has sufficient power with minimal sample size, in order to reduce cost and time. These depend on data variability, partly determined by sample type, preparation and processing. Objective measures that help experimental design, given own pilot data, are thus fundamental.Results: Relative power and sample size analysis were performed on two distinct data sets. The first set consisted of Affymetrix array data derived from a nutrigenomics experiment in which weak, intermediate and strong PPARαagonists were administered to wild-type and PPARα-null mice. Our analysis confirms the hierarchy of PPARα-activating compounds previously reported and the general idea that larger effect sizes positively contribute to the average power of the experiment. A simulation experiment was performed that mimicked the effect sizes seen in the first data set. The relative power was predicted but the estimates were slightly conservative. The second, more challenging, data set describes a microarray platform comparison study using hippocampalδC-doublecortin-like kinase transgenic mice that were compared to wild-type mice, which was combined with results from Solexa/Illumina deep sequencing runs. As expected, the choice of technology greatly influences the performance of the experiment. Solexa/Illumina deep sequencing has the highest overall power followed by the microarray platforms Agilent and Affymetrix. Interestingly, Solexa/Illumina deep sequencing displays comparable power across all intensity ranges, in contrast with microarray platforms that have decreased power in the low intensity range due to background noise. This means that deep sequencing technology is especially more powerful in detecting differences in the low intensity range, compared to microarray platforms.Conclusion: Power and sample size analysis based on pilot data give valuable information on the performance of the experiment and can thereby guide further decisions on experimental design. Solexa/Illumina deep sequencing is the technology of choice if interest lies in genes expressed in the low-intensity range. Researchers can get guidance on experimental design using our approach on their own pilot data implemented as a BioConductor package, SSPAhttp://bioconductor.org/packages/release/bioc/html/SSPA.html.


  • Open Access

    Can subtle changes in gene expression be consistently detected with different microarray platforms?

    by Paola Pedotti, Peter Ac 'T Hoen, Erno Vreugdenhil, Geert J Schenk, Rolf Ham Vossen, Yavuz Ariyurek, Mattias de Hollander, Rowan Kuiper, Gertjan Jb van Ommen, Johan T Den Dunnen, et al.

    Background: The comparability of gene expression data generated with different microarray platforms is still a matter of concern. Here we address the performance and the overlap in the detection of differentially expressed genes for five different microarray platforms in a challenging biological context where differences in gene expression are few and subtle.Results: Gene expression profiles in the hippocampus of five wild-type and five transgenic δC-doublecortin-like kinase mice were evaluated with five microarray platforms: Applied Biosystems, Affymetrix, Agilent, Illumina, LGTC home-spotted arrays. Using a fixed false discovery rate of 10% we detected surprising differences between the number of differentially expressed genes per platform. Four genes were selected by ABI, 130 by Affymetrix, 3,051 by Agilent, 54 by Illumina, and 13 by LGTC. Two genes were found significantly differentially expressed by all platforms and the four genes identified by the ABI platform were found by at least three other platforms. Quantitative RT-PCR analysis confirmed 20 out of 28 of the genes detected by two or more platforms and 8 out of 15 of the genes detected by Agilent only. We observed improved correlations between platforms when ranking the genes based on the significance level than with a fixed statistical cut-off. We demonstrate significant overlap in the affected gene sets identified by the different platforms, although biological processes were represented by only partially overlapping sets of genes. Aberrances in GABA-ergic signalling in the transgenic mice were consistently found by all platforms.Conclusion: The different microarray platforms give partially complementary views on biological processes affected. Our data indicate that when analyzing samples with only subtle differences in gene expression the use of two different platforms might be more attractive than increasing the number of replicates. Commercial two-color platforms seem to have higher power for finding differentially expressed genes between groups with small differences in expression.