TMThomas R. Moench

Thomas R. Moench

*This is an algorithmically generated author record based on publicly available information.

Thomas R. Moench has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Vaginal pH measured in vivo: lactobacilli determine pH and lactic acid concentration

    by Deirdre Elizabeth O’hAnlon, Richard A. Come, Thomas R. Moench

    Lactic acid (protonated lactate) has broad antimicrobial activity. Vaginal lactobacilli produce lactic acid, and are known to confer protection against reproductive tract infections when they are predominant in the vaginal microbiota. Using novel ex vivo methods, we showed that cervicovaginal fluid (CVF) from women with a predominantly lactobacilli-morphotype microbiota contains significantly more lactic acid than previously thought, sufficient to inactivate reproductive tract pathogens. Here, we measured vaginal pH in vivo in 20 women with a predominantly lactobacilli-morphotype (low Nugent score) microbiota. We also investigated the in vitro production of protons (as hydrogen ions) and lactate by vaginal lactobacilli. The average vaginal pH in these women was 3.80 ± 0.20, and the average lactate concentration was 0.79% ± 0.22% w/v, with pH and lactate concentration tightly correlated for each sample. In vitro, lactobacilli cultured from these CVF samples reached an average pH of 3.92 ± 0.22, but the average lactate concentration was only 0.14% ± 0.06% w/v, approximately five-fold less than in the corresponding CVF samples. When the pH of the cultures was raised, lactate and hydrogen ion production resumed, indicating that production of lactate and hydrogen ions by vaginal lactobacilli is limited primarily by their sensitivity to hydrogen ion concentration (low pH) not lactate concentration. Some vaginal lactobacilli cultures have a lower limiting pH than others, and limiting pHs in vitro showed good correlation with pHs measured in vivo. The limiting pH of the lactobacilli predominant in a woman’s vaginal microbiota seems critical in determining the concentration of antimicrobial lactic acid protecting her.


  • Open Access

    Cell-Associated Transmission of HIV Type 1 and Other Lentiviruses in Small-Animal Models

    by Thomas R. Moench

    Small-animal models of lentivirus transmission have repeatedly demonstrated transmission by cell-associated virus via vaginal, rectal, and oral routes. The earliest experiments were in the cat/feline immunodeficiency virus model, followed a decade later by successful vaginal transmission of cell-associated human immunodeficiency virus (HIV) in mice bearing transplanted human immune cells. After early unsuccessful attempts at cell-associated transmission in nonhuman primates, renewed investigation in diverse primate models has now confirmed the findings from the cat and humanized mouse models. Improvements in humanized mouse models have made them the preferred small-animal models to study HIV mucosal transmission. They provide complementary systems to nonhuman primate models to aid in the elucidation of the many remaining questions on the mechanism of and means to prevent both cell-associated and cell-free HIV transmission across mucosal barriers.


  • Top Cited Papers
    Open Access

    In vaginal fluid, bacteria associated with bacterial vaginosis can be suppressed with lactic acid but not hydrogen peroxide

    by Deirdre E O'Hanlon, Thomas R Moench, Richard A Cone

    Hydrogen peroxide (H2O2) produced by vaginal lactobacilli is generally believed to protect against bacteria associated with bacterial vaginosis (BV), and strains of lactobacilli that can produce H2O2 are being developed as vaginal probiotics. However, evidence that led to this belief was based in part on non-physiological conditions, antioxidant-free aerobic conditions selected to maximize both production and microbicidal activity of H2O2. Here we used conditions more like those in vivo to compare the effects of physiologically plausible concentrations of H2O2 and lactic acid on a broad range of BV-associated bacteria and vaginal lactobacilli.


  • Open Access

    Microbicide excipients can greatly increase susceptibility to genital herpes transmission in the mouse

    by Thomas R Moench, Russell J Mumper, Timothy E Hoen, Mianmian Sun, Richard A Cone

    Background: Several active ingredients proposed as vaginal microbicides have been shown paradoxically to increase susceptibility to infection in mouse genital herpes (HSV-2) vaginal susceptibility models and in clinical trials. In addition, "inactive ingredients" (or excipients) used in topical products to formulate and deliver the active ingredient might also cause epithelial toxicities that increase viral susceptibility. However, excipients have not previously been tested in susceptibility models. Methods: Excipients commonly used in topical products were formulated in a non-toxic vehicle (the "HEC universal placebo"), or other formulations as specified. Twelve hours after exposure to the excipient or a control treatment, mice were challenged with a vaginal dose of HSV-2, and three days later were assessed for infection by vaginal lavage culture to assess susceptibility. Results: The following excipients markedly increased susceptibility to HSV-2 after a single exposure: 5% glycerol monolaurate (GML) formulated in K-Y® Warming Jelly, 5% GML as a colloidal suspension in phosphate buffered saline, K-Y Warming Jelly alone, and both of its humectant/solvent ingredients (neat propylene glycol and neat PEG-8). For excipients formulated in the HEC vehicle, 30% glycerin significantly increased susceptibility, and a trend toward increased HSV-2 susceptibility was observed after 10% glycerin, and 0.1% disodium EDTA, but not after 0.0186% disodium EDTA. The following excipients did not increase susceptibility: 10% propylene glycol, 0.18%, methylparaben plus 0.02% propylparaben, and 1% benzyl alcohol. Conclusions: As reported with other surfactants, the surfactant/emulsifier GML markedly increased susceptibility to HSV-2. Glycerin at 30% significantly increased susceptibility, and, undiluted propylene glycol and PEG-8 greatly increased susceptibility.


  • Open Access

    Cervicovaginal fluid and semen block the microbicidal activity of hydrogen peroxide produced by vaginal lactobacilli

    by Deirdre E O'HAnlon, Blair R Lanier, Thomas R Moench, Richard A Cone

    H2O2 produced by vaginal lactobacilli is believed to protect against infection, and H2O2-producing lactobacilli inactivate pathogens in vitro in protein-free salt solution. However, cervicovaginal fluid (CVF) and semen have significant H2O2-blocking activity.


  • Open Access

    An acceptability and safety study of the Duet® cervical barrier and gel delivery system in Zimbabwe

    by Elizabeth T Montgomery, Cynthia Woodsong, Petina Musara, Helen Cheng, Tsungai Chipato, Thomas R Moench, Freya Spielberg, Ariane van der Straten

    Background: Adherence problems with coitally dependent, female‐initiated HIV prevention methods have contributed to several trials' failure to establish efficacy. Continuous use of a cervical barrier with once‐daily cleaning and immediate reinsertion may simplify use for women and improve adherence. We assessed the acceptability and safety of precoital and continuous use of the Duet®, a cervical barrier and gel delivery system, in Zimbabwean women.Methods: Using a two‐arm crossover design with a parallel observation group, we randomized 103 women in a 2:2:1 ratio: (1) to use the Duet continuously for 14 days, followed by a minimum of seven days of washout and then 14 days of precoital use; (2) to use the same Duet regimens in reverse order; or (3) for observation only. Women were aged 18 to 40 years; half were recruited from a pool of previous diaphragm study participants and the other half from the general community. Acceptability and adherence were assessed through an interviewer‐administered questionnaire at each of two follow‐up visits. Safety was monitored through pelvic speculum exams and report of adverse events.Results: The proportion of women who reported consistent Duet use during sex was virtually identical during continuous and precoital regimens (88.6% vs. 88.9%). Partner refusal was the most common reason cited for non‐use during sex in both use regimens. Not having the device handy was the most common reason cited for non‐daily use (in the continuous regimen). Most women were “very comfortable” using it continuously (86.3%) and inserting it precoitally (92.8%). The most favoured Duet attribute was that it did not interfere with “natural” sex (55%). The least favoured Duet attribute was the concern that it might come out during sex (71.3%). No serious adverse events were reported during the study; 57 participants reported 90 adverse events classified as mild or moderate. There were no statistically significant differences in: (1) the proportion of women reporting adverse events; (2) the severity of events among those using the Duet and observational controls; or (3) event severity reported during each regimen use period.Conclusions: In this study, the Duet was found to be acceptable and safe when inserted precoitally or used continuously for 14 days. Assignment to use of the Duet continuously did not increase adherence to the Duet during sex. Future HIV prevention trials should evaluate use of the Duet (precoitally and continuously) with promising microbicide candidates.


  • Open Access

    Vaginal microbicides: detecting toxicities in vivothat paradoxically increase pathogen transmission

    by Richard A Cone, Timothy Hoen, XiXi Wong, Raed Abusuwwa, Deborah J Anderson, Thomas R Moench

    Background: Microbicides must protect against STD pathogens without causing unacceptable toxic effects. Microbicides based on nonoxynol-9 (N9) and other detergents disrupt sperm, HSV and HIV membranes, and these agents are effective contraceptives. But paradoxically N9 fails to protect women against HIV and other STD pathogens, most likely because it causes toxic effects that increase susceptibility. The mouse HSV-2 vaginal transmission model reported here: (a) Directly tests for toxic effects that increase susceptibility to HSV-2, (b) Determines in vivo whether a microbicide can protect against HSV-2 transmission without causing toxicities that increase susceptibility, and (c) Identifies those toxic effects that best correlate with the increased HSV susceptibility. Methods: Susceptibility was evaluated in progestin-treated mice by delivering a low-dose viral inoculum (0.1 ID50) at various times after delivering the candidate microbicide to detect whether the candidate increased the fraction of mice infected. Ten agents were tested – five detergents: nonionic (N9), cationic (benzalkonium chloride, BZK), anionic (sodium dodecylsulfate, SDS), the pair of detergents in C31G (C14AO and C16B); one surface active agent (chlorhexidine); two non-detergents (BufferGel®, and sulfonated polystyrene, SPS); and HEC placebo gel (hydroxyethylcellulose). Toxic effects were evaluated by histology, uptake of a 'dead cell' dye, colposcopy, enumeration of vaginal macrophages, and measurement of inflammatory cytokines. Results: A single dose of N9 protected against HSV-2 for a few minutes but then rapidly increased susceptibility, which reached maximum at 12 hours. When applied at the minimal concentration needed for brief partial protection, all five detergents caused a subsequent increase in susceptibility at 12 hours of ~20–30-fold. Surprisingly, colposcopy failed to detect visible signs of the N9 toxic effect that increased susceptibility at 12 hours. Toxic effects that occurred contemporaneously with increased susceptibility were rapid exfoliation and re-growth of epithelial cell layers, entry of macrophages into the vaginal lumen, and release of one or more inflammatory cytokines (Il-1β, KC, MIP 1α, RANTES). The non-detergent microbicides and HEC placebo caused no significant increase in susceptibility or toxic effects. Conclusion: This mouse HSV-2 model provides a sensitive method to detect microbicide-induced toxicities that increase susceptibility to infection. In this model, there was no concentration at which detergents provided protection without significantly increasing susceptibility.


  • Open Access

    Low pH immobilizes and kills human leukocytes and prevents transmission of cell-associated HIV in a mouse model

    by Stuart S Olmsted, Kristen V Khanna, Erina M Ng, Steven T Whitten, Owen N JohnsonIII, Richard B Markham, Richard A Cone, Thomas R Moench

    Background: Both cell-associated and cell-free HIV virions are present in semen and cervical secretions of HIV-infected individuals. Thus, topical microbicides may need to inactivate both cell-associated and cell-free HIV to prevent sexual transmission of HIV/AIDS. To determine if the mild acidity of the healthy vagina and acid buffering microbicides would prevent transmission by HIV-infected leukocytes, we measured the effect of pH on leukocyte motility, viability and intracellular pH and tested the ability of an acidic buffering microbicide (BufferGel®) to prevent the transmission of cell-associated HIV in a HuPBL-SCID mouse model. Methods: Human lymphocyte, monocyte, and macrophage motilities were measured as a function of time and pH using various acidifying agents. Lymphocyte and macrophage motilities were measured using video microscopy. Monocyte motility was measured using video microscopy and chemotactic chambers. Peripheral blood mononuclear cell (PBMC) viability and intracellular pH were determined as a function of time and pH using fluorescent dyes. HuPBL-SCID mice were pretreated with BufferGel, saline, or a control gel and challenged with HIV-1-infected human PBMCs. Results: Progressive motility was completely abolished in all cell types between pH 5.5 and 6.0. Concomitantly, at and below pH 5.5, the intracellular pH of PBMCs dropped precipitously to match the extracellular medium and did not recover. After acidification with hydrochloric acid to pH 4.5 for 60 min, although completely immotile, 58% of PBMCs excluded ethidium homodimer-1 (dead-cell dye). In contrast, when acidified to this pH with BufferGel, a microbicide designed to maintain vaginal acidity in the presence of semen, only 4% excluded dye at 10 min and none excluded dye after 30 min. BufferGel significantly reduced transmission of HIV-1 in HuPBL-SCID mice (1 of 12 infected) compared to saline (12 of 12 infected) and a control gel (5 of 7 infected). Conclusion: These results suggest that physiologic or microbicide-induced acid immobilization and killing of infected white blood cells may be effective in preventing sexual transmission of cell-associated HIV.


    • 1 October 2004
      • p. S194-200

    Sensitive methods to detect epithelial disruption: tests for microhemorrhage in cervicovaginal lavages.

    by Thomas Moench, Karim Mehrazar, Richard Cone, Paul Blumenthal

    The toxic effects of topical microbicides might include epithelial disruption, and if sufficiently severe, may cause visible bleeding. We have developed two sensitive methods to detect hemorrhage far below the visual detection threshold: an enzyme-linked immunosorbent assay for human hemoglobin and a method for staining and enumerating red blood cells by fluorescent microscopy. We have applied these methods to cervicovaginal and introital lavages, and found them to be sensitive and quantitative over a broad range. Comparing the new techniques with a standard heme-detection assay (Hemastix) we found them to be more sensitive, more objective, more fully quantitative, and more likely to be indicative of recent events. In pilot studies we found that the red blood cell and hemoglobin concentrations in samples taken in the luteal phase of the menstrual cycle are low, but still within the detection range of the new assays, providing a quantifiable baseline from which increases in blood from epithelial disruption can be detected and quantified. We propose that these new methods may be used for the safety assessment of microbicides by detecting and quantifying microhemorrhage in cervicovaginal secretions before and after exposure to microbicide.


  • Sensitive methods to detect epithelial disruption

    by Thomas Moench, Karim Mehrazar, Richard Cone, Paul Blumenthal

    The toxic effects of topical microbicides might include epithelial disruption, and if sufficiently severe, may cause visible bleeding. We have developed two sensitive methods to detect hemorrhage far below the visual detection threshold: an enzyme-linked immunosorbent assay for human hemoglobin and a method for staining and enumerating red blood cells by fluorescent microscopy. We have applied these methods to cervicovaginal and introital lavages, and found them to be sensitive and quantitative over a broad range. Comparing the new techniques with a standard heme-detection assay (Hemastix®) we found them to be more sensitive, more objective, more fully quantitative, and more likely to be indicative of recent events. In pilot studies we found that the red blood cell and hemoglobin concentrations in samples taken in the luteal phase of the menstrual cycle are low, but still within the detection range of the new assays, providing a quantifiable baseline from which increases in blood from epithelial disruption can be detected and quantified. We propose that these new methods may be used for the safety assessment of microbicides by detecting and quantifying microhemorrhage in cervicovaginal secretions before and after exposure to microbicide.