GMGábor Marics

Gábor Marics

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gábor Marics has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Modelling intestinal glucose absorption in premature infants using continuous glucose monitoring data

    by J.L. Knopp, M. Signal, D.L. Harris, G Marics, P. Weston, J. Harding, P. Tóth-Heyn, J. Hómlok, B. Benyó, J.G. Chase


  • Open Access

    Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit

    by Gábor Marics, Zsófia Lendvai, Csaba Lódi, Levente Koncz, Dávid Zakariás, György Schuster, Borbála Mikos, Csaba Hermann, Attila J Szabó, Péter Tóth-Heyn

    Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific application the interpretation of the results is time-consuming, utilizing extreme efforts. Our aim was to create an open access software [Glycemic Variability Analyzer Program (GVAP)], readily available to calculate the most common parameters of the glucose variability and to test its usability. The GVAP was developed in MATLAB® 2010b environment. The calculated parameters were the following: average area above/below the target range (Avg. AUC-H/L); Percentage Spent Above/Below the Target Range (PATR/PBTR); Continuous Overall Net Glycemic Action (CONGA); Mean of Daily Differences (MODD); Mean Amplitude of Glycemic Excursions (MAGE). For verification purposes we selected 14 CGM curves of pediatric critical care patients. Medtronic® Guardian® Real-Time with Enlite® sensor was used. The reference values were obtained from Medtronic®’s own software for Avg. AUC-H/L and PATR/PBTR, from GlyCulator for MODD and CONGA, and using manual calculation for MAGE. The Pearson and Spearman correlation coefficients were above 0.99 for all parameters. The initial execution took 30 minutes, for further analysis with the Windows® Standalone Application approximately 1 minute was needed. The GVAP is a reliable open access program for analyzing different glycemic variability parameters, hence it could be a useful tool for the study of glycemic control among critically ill patients.


  • Open Access

    Effects of pH, lactate, hematocrit and potassium level on the accuracy of continuous glucose monitoring (CGM) in pediatric intensive care unit

    by Gábor Marics, Levente Koncz, Katalin Eitler, Barbara Vatai, Boglárka Szénási, David Zakariás, Borbála Mikos, Anna Körner, Péter Tóth-Heyn

    Continuous glucose monitoring (CGM) originally was developed for diabetic patients and it may be a useful tool for monitoring glucose changes in pediatric intensive care unit (PICU). Its use is, however, limited by the lack of sufficient data on its reliability at insufficient peripheral perfusion. We aimed to correlate the accuracy of CGM with laboratory markers relevant to disturbed tissue perfusion. In 38 pediatric patients (age range, 0–18 years) requiring intensive care we tested the effect of pH, lactate, hematocrit and serum potassium on the difference between CGM and meter glucose measurements. Guardian® (Medtronic®) CGM results were compared to GEM 3000 (Instrumentation laboratory®) and point-of-care measurements. The clinical accuracy of CGM was evaluated by Clarke Error Grid -, Bland-Altman analysis and Pearson’s correlation. We used Friedman test for statistical analysis (statistical significance was established as a p < 0.05). CGM values exhibited a considerable variability without any correlation with the examined laboratory parameters. Clarke, Bland-Altman analysis and Pearson’s correlation coefficient demonstrated a good clinical accuracy of CGM (zone A and B = 96%; the mean difference between reference and CGM glucose was 1,3 mg/dL, 48 from the 780 calibration pairs overrunning the 2 standard deviation; Pearson’s correlation coefficient: 0.83). The accuracy of CGM measurements is independent of laboratory parameters relevant to tissue hypoperfusion. CGM may prove a reliable tool for continuous monitoring of glucose changes in PICUs, not much influenced by tissue perfusion, but still not appropriate for being the base for clinical decisions.


  • Open Access

    Prevalence and etiology of false normal aEEG recordings in neonatal hypoxic-ischaemic encephalopathy

    by Gábor Marics, Anna Csekő, Barna Vásárhelyi, Dávid Zakariás, György Schuster, Miklós Szabó

    Amplitude-integrated electroencephalography (aEEG) is a useful tool to determine the severity of neonatal hypoxic-ischemic encephalopathy (HIE). Our aim was to assess the prevalence and study the origin of false normal aEEG recordings based on 85 aEEG recordings registered before six hours of age.


  • Role of continuous subcutaneous glucose monitoring in intensive care (Orvosi Hetilap, 2013, 154(27), 1043–1048.)

    by Gábor Marics, Levente Koncz, Anna Körner, Borbála Mikos, Péter Tóth-Heyn

  • Role of continuous subcutaneous glucose monitoring in intensive care

    by Gábor Marics, Levente Koncz, Anna Körner, Borbála Mikos, Péter Tóth-Heyn

    Critical care associated with stress hyperglycaemia has gained a new view in the last decade since the demonstration of the beneficial effects of strong glycaemic control on the mortality in intensive care units. Strong glycaemic control may, however, induce hypoglycaemia, resulting in increased mortality, too. Pediatric population has an increased risk of hypoglycaemia because of the developing central nervous system. In this view there is a strong need for close monitoring of glucose levels in intensive care units. The subcutaneous continuous glucose monitoring developed for diabetes care is an alternative for this purpose instead of regular blood glucose measurements. It is important to know the limitations of subcutaneous continuous glucose monitoring in intensive care. Decreased tissue perfusion may disturb the results of subcutaneous continuous glucose monitoring, because the measurement occurs in interstitial fluid. The routine use of subcutaneous continuous glucose monitoring in intensive care units is not recommended yet until sufficient data on the reliability of the system are available. The Medtronic subcutaneous continuous glucose monitoring system is evaluated in the review partly based on the authors own results. Orv. Hetil., 2013, 154, 1043–1048.


  • Autonomic dysfunction of glucose homoeostasis in congenital central hypoventilation syndrome

    by Gábor Marics, Jeanne Amiel, Barbara Vatai, Csaba Lódi, Borbála Mikos, Péter Tóth‐Heyn