Frank J. Visser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Frank J. Visser has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
P.N. Richard Dekhuijzen
2 shared publicationsSunil Ramlal
2 shared publicationsYvonne F. Heijdra
2 shared publications- Ben Pelzer
Dept. of Social Science Research Methods, Radboud University, Nijmegen, 6525 GA, the Netherlands
1 shared publication - Gert Jan van der Wilt
IQ Health, Radboud University Medical Center, Nijmegen, the Netherlands
1 shared publication - Julius Janssen
Canisius Wilhelmina Hospital
1 shared publication
Latest Publications
- Open Access
- 23 November 2010
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 10 (1) , 60
The optimization of the diagnostic work-up in patients with suspected obstructive lung disease
Pulmonary function testing is a key procedure in the work-up of patients who are suspected of having asthma and chronic obstructive lung disease (COPD). Therein, clinical visits and pulmonary function tests (PFTs) are the major contributors to the overall financial costs.
- 23 November 2010
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 10 (1) , 60
Open AccessThe optimization of the diagnostic work-up in patients with suspected obstructive lung disease
Pulmonary function testing is a key procedure in the work-up of patients who are suspected of having asthma and chronic obstructive lung disease (COPD). Therein, clinical visits and pulmonary function tests (PFTs) are the major contributors to the overall financial costs.
- Open Access
- 17 July 2010
- Published by S. Karger AG in Respiration
- Vol. 81 (5) , 372-378
Pursed-Lips Breathing Improves Inspiratory Capacity in Chronic Obstructive Pulmonary Disease
Background: In patients with severe chronic obstructive pulmonary disease (COPD), pursed-lips breathing (PLB) improves the pulmonary gas exchange and hyperinflation measured by electro-optic coupling. The response to PLB in inspiratory lung function tests is not known. Objectives: The purpose of this study was to measure the effect of PLB on inspiratory parameters. Methods: Thirty-five subjects with stable COPD and a forced expiratory volume in first second (FEV1) <50% of the predicted value were tested for the following primary parameters before and immediately after PLB, and 5 min later: forced inspiratory vital capacity, inspiratory capacity (IC), forced inspiratory volume in first second, maximal inspiratory flow at 50% of vital capacity, and peak inspiratory flow. Patients were also tested for the following secondary parameters: vital capacity, FEV1, breathing frequency, end-tidal CO2 tension, and oxygen saturation. Results: Of all the primary parameters only IC (p = 0.006) improved significantly; with regard to the secondary parameters, the mean oxygen saturation was improved by 1% (p = 0.005) and the mean end-tidal CO2 tension and breathing frequency decreased significantly (p < 0.0001 for both) to 3.2 mm Hg and 3.1 breaths/min, respectively. After 5 min the effects diminished. Conclusion: Improved IC after PLB indicates less hyperinflation in patients with severe COPD; there was no effect on parameters of flow.
- 17 July 2010
- Published by S. Karger AG in Respiration
- Vol. 81 (5) , 372-378
Open AccessPursed-Lips Breathing Improves Inspiratory Capacity in Chronic Obstructive Pulmonary Disease
Background: In patients with severe chronic obstructive pulmonary disease (COPD), pursed-lips breathing (PLB) improves the pulmonary gas exchange and hyperinflation measured by electro-optic coupling. The response to PLB in inspiratory lung function tests is not known. Objectives: The purpose of this study was to measure the effect of PLB on inspiratory parameters. Methods: Thirty-five subjects with stable COPD and a forced expiratory volume in first second (FEV1) <50% of the predicted value were tested for the following primary parameters before and immediately after PLB, and 5 min later: forced inspiratory vital capacity, inspiratory capacity (IC), forced inspiratory volume in first second, maximal inspiratory flow at 50% of vital capacity, and peak inspiratory flow. Patients were also tested for the following secondary parameters: vital capacity, FEV1, breathing frequency, end-tidal CO2 tension, and oxygen saturation. Results: Of all the primary parameters only IC (p = 0.006) improved significantly; with regard to the secondary parameters, the mean oxygen saturation was improved by 1% (p = 0.005) and the mean end-tidal CO2 tension and breathing frequency decreased significantly (p < 0.0001 for both) to 3.2 mm Hg and 3.1 breaths/min, respectively. After 5 min the effects diminished. Conclusion: Improved IC after PLB indicates less hyperinflation in patients with severe COPD; there was no effect on parameters of flow.
- Open Access
- 14 May 2010
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 10 (1) , 28
Random variation of inspiratory lung function parameters in patients with COPD: a diagnostic accuracy study
In chronic obstructive pulmonary disease (COPD), the response of the forced expiratory volume in 1 second (FEV1) after bronchodilator application is weak. Inspiratory parameters like the forced inspiratory volume in 1 second (FIV1) and inspiratory capacity (IC) can be responsive to bronchodilators. In an individual patient with COPD, a significant bronchodilator response must at least exceed the random variation for that parameter. Therefore, it is important that the type of scatter is homoscedastic, as the chance of underestimating or overestimating the random variation for low or high parameter values is minimized. The aim of this study is to investigate the random variation (type and quantity) of inspiratory parameters.
- 14 May 2010
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 10 (1) , 28
Open AccessRandom variation of inspiratory lung function parameters in patients with COPD: a diagnostic accuracy study
In chronic obstructive pulmonary disease (COPD), the response of the forced expiratory volume in 1 second (FEV1) after bronchodilator application is weak. Inspiratory parameters like the forced inspiratory volume in 1 second (FIV1) and inspiratory capacity (IC) can be responsive to bronchodilators. In an individual patient with COPD, a significant bronchodilator response must at least exceed the random variation for that parameter. Therefore, it is important that the type of scatter is homoscedastic, as the chance of underestimating or overestimating the random variation for low or high parameter values is minimized. The aim of this study is to investigate the random variation (type and quantity) of inspiratory parameters.
- 21 November 2007
- Published by S. Karger AG in Respiration
- Vol. 76 (1) , 46-52
Recommendations for the Measurement of FIV1 Values in Chronic Obstructive Pulmonary Disease
Background: In contrast to static inspiratory parameters such as vital capacity and inspiratory capacity, information on forced inspiratory volume in 1 s (FIV1) in patients with chronic obstructive pulmonary disease (COPD) is limited. Objectives: It was the aim of this study to investigate the influence of the preceding expiratory manoeuvre and the optimal number of manoeuvres on FIV1 values. Methods: In 169 patients with COPD, FIV1 manoeuvres were performed after a forced (FIV1-Fe) and a slow (FIV1-Se) expiration. To investigate the optimal number of the FIV1-Se manoeuvres, 8 attempts were performed. Results: The variability of FIV1-Fe was greater than that of FIV1-Se. The mean difference between FIV1-Se and FIV1-Fe was 0.21 litres (p < 0.01) and dependent on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage. The higher the GOLD stage, the greater the difference between the 2 techniques. The correlation coefficient between FIV1-Se and FIV1-Fe was high (r = 0.89, p = 0.01), but there was a poor agreement between these parameters (limits of agreement –0.52 to 0.94 litres). Five manoeuvres were needed to obtain an optimal FIV1-Se. There was no association with the GOLD stage. Conclusions: In COPD patients, FIV1-Se are less variable than FIV1-Fe, the agreement between the 2 manoeuvres is poor, and at least 5 FIV1-Se manoeuvres are needed to get an acceptable FIV1. This holds for all GOLD stages.
- 21 November 2007
- Published by S. Karger AG in Respiration
- Vol. 76 (1) , 46-52
Recommendations for the Measurement of FIV1 Values in Chronic Obstructive Pulmonary Disease
Background: In contrast to static inspiratory parameters such as vital capacity and inspiratory capacity, information on forced inspiratory volume in 1 s (FIV1) in patients with chronic obstructive pulmonary disease (COPD) is limited. Objectives: It was the aim of this study to investigate the influence of the preceding expiratory manoeuvre and the optimal number of manoeuvres on FIV1 values. Methods: In 169 patients with COPD, FIV1 manoeuvres were performed after a forced (FIV1-Fe) and a slow (FIV1-Se) expiration. To investigate the optimal number of the FIV1-Se manoeuvres, 8 attempts were performed. Results: The variability of FIV1-Fe was greater than that of FIV1-Se. The mean difference between FIV1-Se and FIV1-Fe was 0.21 litres (p < 0.01) and dependent on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage. The higher the GOLD stage, the greater the difference between the 2 techniques. The correlation coefficient between FIV1-Se and FIV1-Fe was high (r = 0.89, p = 0.01), but there was a poor agreement between these parameters (limits of agreement –0.52 to 0.94 litres). Five manoeuvres were needed to obtain an optimal FIV1-Se. There was no association with the GOLD stage. Conclusions: In COPD patients, FIV1-Se are less variable than FIV1-Fe, the agreement between the 2 manoeuvres is poor, and at least 5 FIV1-Se manoeuvres are needed to get an acceptable FIV1. This holds for all GOLD stages.