Alicja Bojan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alicja Bojan has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Anders Enocson
Department of Molecular Medicine and Surgery, Karolinska Institute, Stockholm, Sweden
2 shared publications Anders Jönsson
Department of Orthopaedics, Institute of Clinical Sciences at Sahlgrenska Academy, Gothenburg University, Sweden
2 shared publicationsCarl Ekholm
Department of Orthopaedics, Institute of Clinical Sciences at Sahlgrenska Academy, Gothenburg University, Sweden
2 shared publications- Carl Ekholm
Department of Orthopaedics, Institute of Clinical Sciences, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Orthopaedics, Sahlgrenska University Hospital, Mölndal, Sweden
2 shared publications - Claudia Beimel
Stryker Trauma GmbH, Schönkirchen, Germany
2 shared publications - Gerard Insley
Applied Material Science, Department of Engineering, Uppsala University, 75121 Uppsala, Sweden
2 shared publications
Latest Publications
- Open Access
- 12 November 2024
- Published by Frontiers Media SA in Frontiers in Medical Engineering
- Vol. 2, 1484232
Gluing osteochondral fragments: development of a novel strategy for dual adhesive application in a preclinical model
This study proposes a novel dual adhesive approach for fixing osteochondral fractures, aiming to address the limitations of current fixation methods by incorporating both a bone adhesive (phosphoserine modified calcium phosphate cement PM-CPC) and a cartilage adhesive (methacrylated phosphoserine-containing gelatin MePGa hydrogel). The feasibility and efficacy of this approach were investigated using an ex vivo bovine knee model. Results indicate successful gluing of osteochondral cylinders with both adhesives, with no significant difference in adhesion strength between the groups (adhesion strength mean of 1211.6 kPa, SD 602.4 kPa, and mean of 1299.6 kPa, SD 850.9 kPa for groups 1 and 2 respectively). Importantly, the inclusion of the hydrogel component in the dual adhesive system aims to enhance cartilage repair potential, complementing the mechanical support provided by the bone adhesive. Each adhesive offers distinctive benefits: PM-CPC for mechanical support and bone repair, and MePGa hydrogel for cartilage repair. The study demonstrates the potential of the dual adhesive strategy for osteochondral repair, though further refinement and in vivo validation are needed.
- 12 November 2024
- Published by Frontiers Media SA in Frontiers in Medical Engineering
- Vol. 2, 1484232
Open AccessGluing osteochondral fragments: development of a novel strategy for dual adhesive application in a preclinical model
This study proposes a novel dual adhesive approach for fixing osteochondral fractures, aiming to address the limitations of current fixation methods by incorporating both a bone adhesive (phosphoserine modified calcium phosphate cement PM-CPC) and a cartilage adhesive (methacrylated phosphoserine-containing gelatin MePGa hydrogel). The feasibility and efficacy of this approach were investigated using an ex vivo bovine knee model. Results indicate successful gluing of osteochondral cylinders with both adhesives, with no significant difference in adhesion strength between the groups (adhesion strength mean of 1211.6 kPa, SD 602.4 kPa, and mean of 1299.6 kPa, SD 850.9 kPa for groups 1 and 2 respectively). Importantly, the inclusion of the hydrogel component in the dual adhesive system aims to enhance cartilage repair potential, complementing the mechanical support provided by the bone adhesive. Each adhesive offers distinctive benefits: PM-CPC for mechanical support and bone repair, and MePGa hydrogel for cartilage repair. The study demonstrates the potential of the dual adhesive strategy for osteochondral repair, though further refinement and in vivo validation are needed.
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 29
GLUEING OSTEOCHONDRAL FRAGMENTS: DEVELOPMENT OF A NOVEL DUAL ADHESIVE PRECLINICAL MODEL STRATEGY
GLUEING OSTEOCHONDRAL FRAGMENTS: DEVELOPMENT OF A NOVEL DUAL ADHESIVE PRECLINICAL MODEL STRATEGY
- 2 January 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_1) , 29
GLUEING OSTEOCHONDRAL FRAGMENTS: DEVELOPMENT OF A NOVEL DUAL ADHESIVE PRECLINICAL MODEL STRATEGY
GLUEING OSTEOCHONDRAL FRAGMENTS: DEVELOPMENT OF A NOVEL DUAL ADHESIVE PRECLINICAL MODEL STRATEGY
- 25 July 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (19) , 1703-1711
No Difference in Conversion Rate to Hip Arthroplasty After Intramedullary Nail or Sliding Hip Screw for Extracapsular Hip Fractures
Background: The widespread use of intramedullary nails (IMNs) compared with sliding hip screws (SHSs) in extracapsular hip fractures (AO/OTA 31-A1, 31-A2, 31-A3) has been questioned because of a higher complication rate, although the outcome might have improved through more recent implant designs and the learning curve. This study aimed to investigate if there is a difference with regard to the cumulative incidence of conversion to arthroplasty or any reoperation during the first 5 years after IMN or SHS fixation of extracapsular hip fractures. Methods: In this nationwide, observational cohort study, individuals who were ≥60 years of age and were registered in the Swedish Fracture Register (SFR) from 2012 to 2018 due to extracapsular fracture and were primarily treated with an IMN or SHS were followed in the SFR and the Swedish Arthroplasty Register (SAR) for a minimum of 1 year. The primary outcome was the cumulative incidence of conversion to arthroplasty (conversion rate). The secondary outcome was the cumulative incidence of all reoperations (reoperation rate). Both were calculated in a competing risk analysis during the first 5 years. Results: We included 19,604 individuals (70% women), with a median age of 85 years (range, 60 to 107 years). The 31-A2 fracture was most prevalent (52%), followed by the 31-A1 fracture (28%). No significant differences were seen in the 1-year conversion rate after IMN or SHS use (1.0% compared with 0.9% in the 31-A1 fractures, 1.7% compared with 1.3% in the 31-A2 fractures, and 1.3% compared with 1.5% in the 31-A3 fractures) or in the 1-year reoperation rate (1.9% compared with 1.9% in the type-A1 fractures, 3.4% compared with 2.5% in the type-A2 fractures, and 4.0% compared with 5.2% in the type-A3 fractures). Only in 31-A2 fractures were more reoperations seen after IMN use at 2 and 5 years (p < 0.05). The crude 1-year-mortality was 26.4% (5,178 of 19,604), without significant differences between implants. Conclusions: Considering conversion arthroplasty, IMNs and SHSs performed equally well in general. IMN use was associated with more reoperations than SHS use in 31-A2 fractures at 2 years. However, from a clinical perspective, the differences between the implants were small, in particular when considering the competing risk of dying. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 25 July 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (19) , 1703-1711
No Difference in Conversion Rate to Hip Arthroplasty After Intramedullary Nail or Sliding Hip Screw for Extracapsular Hip Fractures
Background: The widespread use of intramedullary nails (IMNs) compared with sliding hip screws (SHSs) in extracapsular hip fractures (AO/OTA 31-A1, 31-A2, 31-A3) has been questioned because of a higher complication rate, although the outcome might have improved through more recent implant designs and the learning curve. This study aimed to investigate if there is a difference with regard to the cumulative incidence of conversion to arthroplasty or any reoperation during the first 5 years after IMN or SHS fixation of extracapsular hip fractures. Methods: In this nationwide, observational cohort study, individuals who were ≥60 years of age and were registered in the Swedish Fracture Register (SFR) from 2012 to 2018 due to extracapsular fracture and were primarily treated with an IMN or SHS were followed in the SFR and the Swedish Arthroplasty Register (SAR) for a minimum of 1 year. The primary outcome was the cumulative incidence of conversion to arthroplasty (conversion rate). The secondary outcome was the cumulative incidence of all reoperations (reoperation rate). Both were calculated in a competing risk analysis during the first 5 years. Results: We included 19,604 individuals (70% women), with a median age of 85 years (range, 60 to 107 years). The 31-A2 fracture was most prevalent (52%), followed by the 31-A1 fracture (28%). No significant differences were seen in the 1-year conversion rate after IMN or SHS use (1.0% compared with 0.9% in the 31-A1 fractures, 1.7% compared with 1.3% in the 31-A2 fractures, and 1.3% compared with 1.5% in the 31-A3 fractures) or in the 1-year reoperation rate (1.9% compared with 1.9% in the type-A1 fractures, 3.4% compared with 2.5% in the type-A2 fractures, and 4.0% compared with 5.2% in the type-A3 fractures). Only in 31-A2 fractures were more reoperations seen after IMN use at 2 and 5 years (p < 0.05). The crude 1-year-mortality was 26.4% (5,178 of 19,604), without significant differences between implants. Conclusions: Considering conversion arthroplasty, IMNs and SHSs performed equally well in general. IMN use was associated with more reoperations than SHS use in 31-A2 fractures at 2 years. However, from a clinical perspective, the differences between the implants were small, in particular when considering the competing risk of dying. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 21 March 2020
- Published by MDPI AG in Chemengineering
- Vol. 4 (1) , 19
Factors That Determine the Adhesive Strength in a Bioinspired Bone Tissue Adhesive
Phosphoserine-modified cements (PMCs) are a family of wet-field tissue adhesives that bond strongly to bone and biomaterials. The present study evaluated variations in the adhesive strength using a scatter plot, failure mode, and a regression analysis of eleven factors. All single-factor, continuous-variable correlations were poor (R2 < 0.25). The linear regression model explained 31.6% of variation in adhesive strength (R2 = 0.316 p < 0.001), with bond thickness predicting an 8.5% reduction in strength per 100 μm increase. Interestingly, PMC adhesive strength was insensitive to surface roughness (Sa 1.27–2.17 μm) and the unevenness (skew) of the adhesive bond (p > 0.167, 0.171, ANOVA). Bone glued in conditions mimicking the operating theatre (e.g., the rapid fixation and minimal fixation force in fluids) produced comparable adhesive strength in laboratory conditions (2.44 vs. 1.96 MPa, p > 0.986). The failure mode correlated strongly with the adhesive strength; low strength PMCs (2 MPa) PMCs failed adhesively. Failure occurred at the interface between the amorphous surface layer and the PMC bulk. PMC bonding is sufficient for clinical application, allowing for a wide tolerance in performance conditions while maintaining a minimal bond strength of 1.5–2 MPa to cortical bone and metal surfaces.
- 21 March 2020
- Published by MDPI AG in Chemengineering
- Vol. 4 (1) , 19
Open AccessFactors That Determine the Adhesive Strength in a Bioinspired Bone Tissue Adhesive
Phosphoserine-modified cements (PMCs) are a family of wet-field tissue adhesives that bond strongly to bone and biomaterials. The present study evaluated variations in the adhesive strength using a scatter plot, failure mode, and a regression analysis of eleven factors. All single-factor, continuous-variable correlations were poor (R2 < 0.25). The linear regression model explained 31.6% of variation in adhesive strength (R2 = 0.316 p < 0.001), with bond thickness predicting an 8.5% reduction in strength per 100 μm increase. Interestingly, PMC adhesive strength was insensitive to surface roughness (Sa 1.27–2.17 μm) and the unevenness (skew) of the adhesive bond (p > 0.167, 0.171, ANOVA). Bone glued in conditions mimicking the operating theatre (e.g., the rapid fixation and minimal fixation force in fluids) produced comparable adhesive strength in laboratory conditions (2.44 vs. 1.96 MPa, p > 0.986). The failure mode correlated strongly with the adhesive strength; low strength PMCs (2 MPa) PMCs failed adhesively. Failure occurred at the interface between the amorphous surface layer and the PMC bulk. PMC bonding is sufficient for clinical application, allowing for a wide tolerance in performance conditions while maintaining a minimal bond strength of 1.5–2 MPa to cortical bone and metal surfaces.
- Top Cited PapersOpen Access
- 8 February 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Epidemiology, classification, treatment and mortality of distal radius fractures in adults: an observational study of 23,394 fractures from the national Swedish fracture register
Background: Distal radius fractures are the most common of all fractures. Optimal treatment is still debated. Previous studies report substantial changes in treatment trends in recent decades. Few nation-wide studies on distal radius fracture epidemiology and treatment exist, none of which provide detailed data on patient and injury characteristics, fracture pattern and mortality. The aim of this study was to describe the epidemiology, fracture classification, current treatment regimens and mortality of distal radius fractures in adults within the context of a large national register study. Methods: We performed a descriptive study using prospectively registered data from the Swedish fracture register. Included were all non-pathological distal radius fractures registered between January 1st 2015 and December 31st 2017 in patients aged 18 years and above. Nominal variables were presented as proportions of all registered fractures. Results: A total of 23,394 distal radius fractures in 22,962 patients were identified. The mean age was 62.7 ± 17.6 years for all, 65.4 ± 16.0 for women and 53.6 ± 20.0 for men. A simple fall was the most common cause of injury (75%, n = 17,643/23,394). One third (33%, n = 7783/21,723) of all fractures occurred at the patients’ residence. 65% (n = 15,178/23,394) of all fractures were classified as extra-articular AO-23-A, 12% (n = 2770/23,394) as partially intra-articular AO-23-B and 23% (n = 5446/23,394) as intra-articular AO-23-C. The primary treatment was non-surgical for 74% (n = 17,358/23,369) and surgical for 26% (n = 6011/23,369) of all fractures. Only 18% of the AO-23-A fractures were treated surgically, compared to 48% of the AO-23-C fractures. The most frequently used surgical method was plate fixation (82%, n = 4954/5972), followed by pin/wire fixation (8.2%, n = 490/5972), external fixation (4.8%, n = 289/5972) and other methods (4.0%, n = 239/5972). The overall 30-day mortality was 0.4% (n = 98/23,394) and the 1-year mortality 2.9% (n = 679/23,394). Conclusion: This nation-wide observational study provides comprehensive data on the epidemiology, fracture classification and current treatment regimens of distal radius fractures in a western European setting. The most common patient was an eldery woman who sustained a distal radius fracture through a simple fall in her own residence, and whose fracture was extra-articluar and treated non-surgically.
- 8 February 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-9
Top Cited PapersOpen AccessEpidemiology, classification, treatment and mortality of distal radius fractures in adults: an observational study of 23,394 fractures from the national Swedish fracture register
Background: Distal radius fractures are the most common of all fractures. Optimal treatment is still debated. Previous studies report substantial changes in treatment trends in recent decades. Few nation-wide studies on distal radius fracture epidemiology and treatment exist, none of which provide detailed data on patient and injury characteristics, fracture pattern and mortality. The aim of this study was to describe the epidemiology, fracture classification, current treatment regimens and mortality of distal radius fractures in adults within the context of a large national register study. Methods: We performed a descriptive study using prospectively registered data from the Swedish fracture register. Included were all non-pathological distal radius fractures registered between January 1st 2015 and December 31st 2017 in patients aged 18 years and above. Nominal variables were presented as proportions of all registered fractures. Results: A total of 23,394 distal radius fractures in 22,962 patients were identified. The mean age was 62.7 ± 17.6 years for all, 65.4 ± 16.0 for women and 53.6 ± 20.0 for men. A simple fall was the most common cause of injury (75%, n = 17,643/23,394). One third (33%, n = 7783/21,723) of all fractures occurred at the patients’ residence. 65% (n = 15,178/23,394) of all fractures were classified as extra-articular AO-23-A, 12% (n = 2770/23,394) as partially intra-articular AO-23-B and 23% (n = 5446/23,394) as intra-articular AO-23-C. The primary treatment was non-surgical for 74% (n = 17,358/23,369) and surgical for 26% (n = 6011/23,369) of all fractures. Only 18% of the AO-23-A fractures were treated surgically, compared to 48% of the AO-23-C fractures. The most frequently used surgical method was plate fixation (82%, n = 4954/5972), followed by pin/wire fixation (8.2%, n = 490/5972), external fixation (4.8%, n = 289/5972) and other methods (4.0%, n = 239/5972). The overall 30-day mortality was 0.4% (n = 98/23,394) and the 1-year mortality 2.9% (n = 679/23,394). Conclusion: This nation-wide observational study provides comprehensive data on the epidemiology, fracture classification and current treatment regimens of distal radius fractures in a western European setting. The most common patient was an eldery woman who sustained a distal radius fracture through a simple fall in her own residence, and whose fracture was extra-articluar and treated non-surgically.
- Open Access
- 8 May 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 197
Femoral fracture classification in the Swedish Fracture Register – a validity study
A total of more than 270,000 fractures are registered in the Swedish Fracture Register (SFR), a national quality register. Fractures are classified following the AO/OTA classification, commonly by a junior doctor. As a step in the process of validating the data in the SFR, several studies of the accuracy of the fracture classification have already been published. The aim of this study was to evaluate the accuracy of femoral fracture classification in the SFR. One hundred and eighteen femur fractures were randomly selected from the SFR. Three experienced orthopaedic surgeons individually classified these fractures on two separate occasions and a gold standard classification was established. This classification was compared with the original classification in the SFR. Inter- and intraobserver agreement was calculated. The agreement between the classification in the SFR and the gold standard classification was kappa = 0.65 for the AO/OTA group and kappa = 0.83 for the AO/OTA type. This corresponds to substantial and almost perfect agreement, according to Landis and Koch. The kappa values for interobserver agreement ranged from 0.64–0.76 for the AO/OTA group and 0.76–0.85 for the AO/OTA type. The kappa values for intraobserver agreement ranged from 0.79–0.81 for the AO/OTA group and 0.91–0.93 for the AO/OTA type. The classification of femoral fractures in the Swedish Fracture Register is substantial (AO/OTA group) to almost perfect (AO/OTA type) and as accurate as in previous studies. The present study also shows that the agreement between the SFR classification and a gold standard classification is in the same range of agreement as between experienced raters. In contrast to previous studies, the classifications in the SFR are made by an unselected group of mostly inexperienced classifiers. The results indicate that the fracture classification in a national quality register can be accurate enough to permit the evaluation of fracture treatment in specific groups of fractures.
- 8 May 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 197
Open AccessFemoral fracture classification in the Swedish Fracture Register – a validity study
A total of more than 270,000 fractures are registered in the Swedish Fracture Register (SFR), a national quality register. Fractures are classified following the AO/OTA classification, commonly by a junior doctor. As a step in the process of validating the data in the SFR, several studies of the accuracy of the fracture classification have already been published. The aim of this study was to evaluate the accuracy of femoral fracture classification in the SFR. One hundred and eighteen femur fractures were randomly selected from the SFR. Three experienced orthopaedic surgeons individually classified these fractures on two separate occasions and a gold standard classification was established. This classification was compared with the original classification in the SFR. Inter- and intraobserver agreement was calculated. The agreement between the classification in the SFR and the gold standard classification was kappa = 0.65 for the AO/OTA group and kappa = 0.83 for the AO/OTA type. This corresponds to substantial and almost perfect agreement, according to Landis and Koch. The kappa values for interobserver agreement ranged from 0.64–0.76 for the AO/OTA group and 0.76–0.85 for the AO/OTA type. The kappa values for intraobserver agreement ranged from 0.79–0.81 for the AO/OTA group and 0.91–0.93 for the AO/OTA type. The classification of femoral fractures in the Swedish Fracture Register is substantial (AO/OTA group) to almost perfect (AO/OTA type) and as accurate as in previous studies. The present study also shows that the agreement between the SFR classification and a gold standard classification is in the same range of agreement as between experienced raters. In contrast to previous studies, the classifications in the SFR are made by an unselected group of mostly inexperienced classifiers. The results indicate that the fracture classification in a national quality register can be accurate enough to permit the evaluation of fracture treatment in specific groups of fractures.
- Top Cited PapersOpen Access
- 12 October 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 1-8
Epidemiology, treatment and mortality of trochanteric and subtrochanteric hip fractures: data from the Swedish fracture register
Hip fractures are a major worldwide public health problem and includes two main types of fractures: the intracapsular (cervical) and the extracapsular (trochanteric and subtrochanteric) fractures. The aim of this study on patients with trochanteric and subtrochanteric hip fractures was to describe the epidemiology, treatment and outcome in terms of mortality within the context of a large register study. A descriptive epidemiological register study including patients registered in the national Swedish Fracture Register from January 2014 to December 2016. Inclusion criteria were all primary surgically treated traumatic non-pathological trochanteric and subtrochanteric femoral fractures in patients aged 18 years and above. Individual patient data (age, gender, injury location, injury cause, fracture type, treatment and timing of surgery) were retrieved from the register database. Mortality data was obtained via linkage to the Swedish Death Register. A total of 10,548 consecutive patients were identified and included in the study. The mean (±SD) age for all patients was 82 ± 11 years and the majority of the patients were females (69%). Most of the fractures were caused by a fall at the same level (83%) at the patients’ accommodation (75%). Fractures were classified using the AO/OTA classification as 31-A1 in 29%, as 31-A2 in 49% and as 31-A3 in 22% of the cases. The most commonly used implant was a short antegrade intramedullary nail (42%), followed by a plate with sliding hip screw (37%). With increasing fracture complexity, the proportion of intramedullary nails was increasing, and also the use of long versus short nails. The majority of the patients were operated within 36 h (90%). There was a higher mortality at 30 days and 1 year for males, and for all those who were delayed to surgery > 36 h. Safety measures to prevent fall at elderly patient’s accommodation might be a way to reduce the number of trochanteric and subtrochanteric hip fractures. Surgery as soon as possible without delay should be considered to reduce the mortality rate. The selection of surgical methods depends on the fracture complexity.
- 12 October 2018
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 19 (1) , 1-8
Top Cited PapersOpen AccessEpidemiology, treatment and mortality of trochanteric and subtrochanteric hip fractures: data from the Swedish fracture register
Hip fractures are a major worldwide public health problem and includes two main types of fractures: the intracapsular (cervical) and the extracapsular (trochanteric and subtrochanteric) fractures. The aim of this study on patients with trochanteric and subtrochanteric hip fractures was to describe the epidemiology, treatment and outcome in terms of mortality within the context of a large register study. A descriptive epidemiological register study including patients registered in the national Swedish Fracture Register from January 2014 to December 2016. Inclusion criteria were all primary surgically treated traumatic non-pathological trochanteric and subtrochanteric femoral fractures in patients aged 18 years and above. Individual patient data (age, gender, injury location, injury cause, fracture type, treatment and timing of surgery) were retrieved from the register database. Mortality data was obtained via linkage to the Swedish Death Register. A total of 10,548 consecutive patients were identified and included in the study. The mean (±SD) age for all patients was 82 ± 11 years and the majority of the patients were females (69%). Most of the fractures were caused by a fall at the same level (83%) at the patients’ accommodation (75%). Fractures were classified using the AO/OTA classification as 31-A1 in 29%, as 31-A2 in 49% and as 31-A3 in 22% of the cases. The most commonly used implant was a short antegrade intramedullary nail (42%), followed by a plate with sliding hip screw (37%). With increasing fracture complexity, the proportion of intramedullary nails was increasing, and also the use of long versus short nails. The majority of the patients were operated within 36 h (90%). There was a higher mortality at 30 days and 1 year for males, and for all those who were delayed to surgery > 36 h. Safety measures to prevent fall at elderly patient’s accommodation might be a way to reduce the number of trochanteric and subtrochanteric hip fractures. Surgery as soon as possible without delay should be considered to reduce the mortality rate. The selection of surgical methods depends on the fracture complexity.
- 24 February 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (5) , 705-711
Three‐dimensional bone‐implant movements in trochanteric hip fractures: Precision and accuracy of radiostereometric analysis in a phantom model
The accuracy and precision of RSA were evaluated in the experimental study of screw cut‐out complication after fixation of trochanteric fractures. A plastic bone model of a two‐part trochanteric fracture was constructed with a Gamma nail implant incorporating RSA markers. The femoral head fragment was attached to a separate rotational table and the femoral shaft was mounted on the micrometer. Three main motions were simulated: Femoral head translation and rotation along the axis of the lag screw and fracture fragment translation along anatomical axes. Accuracy and precision were determined according to ISO 16,087 and ASTM standard F2385‐04. Translations along the lag screw axis were measured with a precision within ±0.14 mm and an accuracy within ±0.03 mm. With simultaneous translations along all three anatomical axes, lowest precision was measured for the x‐axis (±0.29, 0.07 mm, respectively), but improved when analyzed as a vector (±0.08, 0.03 mm). The precision and accuracy of femoral head rotations were within 0.5° and 0.18°, respectively. The resolution of the RSA method tested in this model was high, though it varied depending on the type of analyzed motion. This information is valuable when selecting and interpreting outcome parameters evaluating implant migration and osteosynthesis stability in future clinical RSA studies. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:705–711, 2015.
- 24 February 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (5) , 705-711
Three‐dimensional bone‐implant movements in trochanteric hip fractures: Precision and accuracy of radiostereometric analysis in a phantom model
The accuracy and precision of RSA were evaluated in the experimental study of screw cut‐out complication after fixation of trochanteric fractures. A plastic bone model of a two‐part trochanteric fracture was constructed with a Gamma nail implant incorporating RSA markers. The femoral head fragment was attached to a separate rotational table and the femoral shaft was mounted on the micrometer. Three main motions were simulated: Femoral head translation and rotation along the axis of the lag screw and fracture fragment translation along anatomical axes. Accuracy and precision were determined according to ISO 16,087 and ASTM standard F2385‐04. Translations along the lag screw axis were measured with a precision within ±0.14 mm and an accuracy within ±0.03 mm. With simultaneous translations along all three anatomical axes, lowest precision was measured for the x‐axis (±0.29, 0.07 mm, respectively), but improved when analyzed as a vector (±0.08, 0.03 mm). The precision and accuracy of femoral head rotations were within 0.5° and 0.18°, respectively. The resolution of the RSA method tested in this model was high, though it varied depending on the type of analyzed motion. This information is valuable when selecting and interpreting outcome parameters evaluating implant migration and osteosynthesis stability in future clinical RSA studies. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:705–711, 2015.