Lilian Chrystiane Giannasi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lilian Chrystiane Giannasi has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Claudia Santos Oliveira
Graduate Program in Human Movement and Rehabilitation, Evangelical University of Goiás (UniEvangélica), Anápolis 75083-515, GO, Brazil
13 shared publications Luis Vicente Franco de Oliveira
Master's Program in Rehabilitation Sciences, Nove de Julho University - UNINOVE, São Paulo, Brazil
7 shared publications- Luciana Maria Malosá Sampaio
Universidade Nove de Julho, São Paulo, Brazil
5 shared publications - Luis Vicente Franco De Oliveira
Universidade Nove de Julho, Brasil
5 shared publications - Paulo de Tarso Camillo de Carvalho
Postgraduate Program in Rehabilitation Sciences, Nove de Julho University, São Paulo, SP, Brazil
5 shared publications - Fernando Sérgio Studart Leitão Filho
Medicine School, Universidade de Fortaleza, Fortaleza, CE, Brazil
4 shared publications
Latest Publications
- Open Access
- 1 September 2020
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 25 (5) , 44-50
A singular oral appliance to treat obstructive sleep apnea in CPAP non-adherent patients
Introduction: The most prescribed treatment option for Obstructive Sleep Apnea (OSA) is CPAP; however, its adherence is limited. Oral Appliance therapy (OAT) is frequently an option or even an adjuvant, being the mandibular advancement Oral Appliance (OAm) the most used prescription. It modifies the upper airway, improving the airway patency. OAm construction is based on the occlusal plane to disocclusion. In this study, the DIORS® appliance was used, a singular OAm, based on Neuro-Occlusal Rehabilitation concepts, that uses Camper’s plane as a disocclusion reference, in order to achieve neuromuscular balance and functional stability. Objective: This study primarily aimed to assess the DIORS® effectiveness in relation to clinical and polysomnographic outcomes. It was also evaluated if the use of DIORS® is as effective as titrated CPAP to treat CPAP non-adherent patients. Methods: Twenty patients were included in this study. Objective and subjective clinical data were assessed at a sleep laboratory using all-night polysomnography, and Epworth Sleepiness Scale (ESS), taken at three moments: Baseline, CPAP titration, and using DIORS®. Analysis of respiratory parameters as apnea/hypopnea index (AHI), oxyhemoglobin saturation levels, the arousal index and daytime sleepiness were taken as criteria for a successful OAT. Results: Respiratory and arousal parameters improved in both therapies, while DIORS® promoted a better ESS. Conclusion: Results from the present work support that DIORS® is a viable and effective adjuvant therapy for patients with moderate to severe OSA non-adherent to CPAP.
- 1 September 2020
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 25 (5) , 44-50
Open AccessA singular oral appliance to treat obstructive sleep apnea in CPAP non-adherent patients
Introduction: The most prescribed treatment option for Obstructive Sleep Apnea (OSA) is CPAP; however, its adherence is limited. Oral Appliance therapy (OAT) is frequently an option or even an adjuvant, being the mandibular advancement Oral Appliance (OAm) the most used prescription. It modifies the upper airway, improving the airway patency. OAm construction is based on the occlusal plane to disocclusion. In this study, the DIORS® appliance was used, a singular OAm, based on Neuro-Occlusal Rehabilitation concepts, that uses Camper’s plane as a disocclusion reference, in order to achieve neuromuscular balance and functional stability. Objective: This study primarily aimed to assess the DIORS® effectiveness in relation to clinical and polysomnographic outcomes. It was also evaluated if the use of DIORS® is as effective as titrated CPAP to treat CPAP non-adherent patients. Methods: Twenty patients were included in this study. Objective and subjective clinical data were assessed at a sleep laboratory using all-night polysomnography, and Epworth Sleepiness Scale (ESS), taken at three moments: Baseline, CPAP titration, and using DIORS®. Analysis of respiratory parameters as apnea/hypopnea index (AHI), oxyhemoglobin saturation levels, the arousal index and daytime sleepiness were taken as criteria for a successful OAT. Results: Respiratory and arousal parameters improved in both therapies, while DIORS® promoted a better ESS. Conclusion: Results from the present work support that DIORS® is a viable and effective adjuvant therapy for patients with moderate to severe OSA non-adherent to CPAP.
- Open Access
- 4 May 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
Intra-Day and Inter-Day Reliability of Measurements of the electromyographic signal on masseter and temporal muscles in patients with Down syndrome
The aim of the present study was to evaluate intra-day (test) and inter-day (re-test) reliability of surface electromyography (sEMG) signals of the masseter and temporal muscles in patients with Down syndrome (DS). We determined the reliability of sEMG variables in 33 patients with DS. EMG signals were recorded at rest as well as during maximum voluntary clenching and maximum habitual intercuspation (MHI). The signals were analyzed considering the amplitude in the root mean square (RMS), mean frequency (MNF), median frequency (MDF) and approximate entropy (ApEn). The intraclass correlation (ICC2,1) for the three trials recorded during MHI in the two sessions (test and retest) revealed excellent intra-session and inter-session reliability (ICC2,1 = 0.76 to 0.97) for all sEMG variables and muscles. In the rest position, excellent reliability was found for RMS and ApEn (ICC2,1 = 0.75 to 1.00) and good to excellent reliability was found for MDF and MNF (ICC2,1 = 0.64 to 0.93). The intra-session (test) and inter-session (re-test) analyses demonstrated the reliability of nonlinear sEMG variables of the masticatory muscles in adults with Down Syndrome.
- 4 May 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
Open AccessIntra-Day and Inter-Day Reliability of Measurements of the electromyographic signal on masseter and temporal muscles in patients with Down syndrome
The aim of the present study was to evaluate intra-day (test) and inter-day (re-test) reliability of surface electromyography (sEMG) signals of the masseter and temporal muscles in patients with Down syndrome (DS). We determined the reliability of sEMG variables in 33 patients with DS. EMG signals were recorded at rest as well as during maximum voluntary clenching and maximum habitual intercuspation (MHI). The signals were analyzed considering the amplitude in the root mean square (RMS), mean frequency (MNF), median frequency (MDF) and approximate entropy (ApEn). The intraclass correlation (ICC2,1) for the three trials recorded during MHI in the two sessions (test and retest) revealed excellent intra-session and inter-session reliability (ICC2,1 = 0.76 to 0.97) for all sEMG variables and muscles. In the rest position, excellent reliability was found for RMS and ApEn (ICC2,1 = 0.75 to 1.00) and good to excellent reliability was found for MDF and MNF (ICC2,1 = 0.64 to 0.93). The intra-session (test) and inter-session (re-test) analyses demonstrated the reliability of nonlinear sEMG variables of the masticatory muscles in adults with Down Syndrome.
- Open Access
- 11 April 2019
- Published by Springer Nature in Trials
- Vol. 20 (1) , 215
Evaluation of the masticatory muscle function, physiological sleep variables, and salivary parameters after electromechanical therapeutic approaches in adult patients with Down syndrome: a randomized controlled clinical trial
There are many comorbidities associated with Down syndrome (DS), including obstructive sleep apnea (OSA) and masticatory muscle alteration. Muscular hypotonia, in particular, of the masticatory and oropharyngeal muscles is one of the main characteristics of individuals with DS, resulting in impairments of speech, swallowing, and mastication in these individuals. In addition, total or partial obstruction of the airways during sleep can occur due to pharyngeal hypotonia, leading to snoring and to OSA. This progressive respiratory disorder is associated with a high risk of morbidity and mortality in individuals with DS. The aim of this research is to assess the therapeutic effects of surface neuromuscular electrical stimulation (NMES), the mastication apparatus (MA), and a mandibular advancement oral appliance (OAm) with an embedded thermosensitive microchip on the functions of masticatory muscles (bilateral masseter and temporal muscles), physiological sleep variables, and salivary parameters in adult patients with DS. The patients with DS will be randomly selected and divided into three groups (DS-NMES, DS-MA, and DS-OAm) with a minimum of 10 patients in each group. A thermosensitive microchip will be embedded in the OAm to record its compliance. The therapeutic effects on masticatory muscle function will be investigated through electromyography, a caliper, and a force-transducer device; the sleep variables, in turn, will be evaluated by means of polysomnography. The physicochemical and microbiological properties of the saliva will also be analyzed, including the salivary flow, viscosity, buffer capacity, cortisol levels (susceptibility to psychological and/or physical stress), and Pseudomonas aeruginosa levels (risk of aspiration pneumonia) in these patients. The methods determined for this study will be carried out prior to and after 2 months of the recommended therapies. The primary outcomes would be the improvement and/or reestablishment of the function of masticatory muscles and the physiological sleep variables in this target public since individuals with DS commonly present generalized muscular hypotonia and dysfunction of the oropharyngeal musculature. As a secondary outcome indicator, the impact of the applied therapies (NMES, MA, and OAm) on the salivary microbiological and physicochemical properties in DS individuals will also be assessed. Furthermore, the compliance of OAm usage will be measured through a thermosensitive microchip. Registro Brasileiro de Ensaios Clínicos, RBR-3qp5np . Registered on 20 February 2018.
- 11 April 2019
- Published by Springer Nature in Trials
- Vol. 20 (1) , 215
Open AccessEvaluation of the masticatory muscle function, physiological sleep variables, and salivary parameters after electromechanical therapeutic approaches in adult patients with Down syndrome: a randomized controlled clinical trial
There are many comorbidities associated with Down syndrome (DS), including obstructive sleep apnea (OSA) and masticatory muscle alteration. Muscular hypotonia, in particular, of the masticatory and oropharyngeal muscles is one of the main characteristics of individuals with DS, resulting in impairments of speech, swallowing, and mastication in these individuals. In addition, total or partial obstruction of the airways during sleep can occur due to pharyngeal hypotonia, leading to snoring and to OSA. This progressive respiratory disorder is associated with a high risk of morbidity and mortality in individuals with DS. The aim of this research is to assess the therapeutic effects of surface neuromuscular electrical stimulation (NMES), the mastication apparatus (MA), and a mandibular advancement oral appliance (OAm) with an embedded thermosensitive microchip on the functions of masticatory muscles (bilateral masseter and temporal muscles), physiological sleep variables, and salivary parameters in adult patients with DS. The patients with DS will be randomly selected and divided into three groups (DS-NMES, DS-MA, and DS-OAm) with a minimum of 10 patients in each group. A thermosensitive microchip will be embedded in the OAm to record its compliance. The therapeutic effects on masticatory muscle function will be investigated through electromyography, a caliper, and a force-transducer device; the sleep variables, in turn, will be evaluated by means of polysomnography. The physicochemical and microbiological properties of the saliva will also be analyzed, including the salivary flow, viscosity, buffer capacity, cortisol levels (susceptibility to psychological and/or physical stress), and Pseudomonas aeruginosa levels (risk of aspiration pneumonia) in these patients. The methods determined for this study will be carried out prior to and after 2 months of the recommended therapies. The primary outcomes would be the improvement and/or reestablishment of the function of masticatory muscles and the physiological sleep variables in this target public since individuals with DS commonly present generalized muscular hypotonia and dysfunction of the oropharyngeal musculature. As a secondary outcome indicator, the impact of the applied therapies (NMES, MA, and OAm) on the salivary microbiological and physicochemical properties in DS individuals will also be assessed. Furthermore, the compliance of OAm usage will be measured through a thermosensitive microchip. Registro Brasileiro de Ensaios Clínicos, RBR-3qp5np . Registered on 20 February 2018.
- Open Access
- 6 August 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (8) , e0128959
Effects of Neuromuscular Electrical Stimulation on the Masticatory Muscles and Physiologic Sleep Variables in Adults with Cerebral Palsy: A Novel Therapeutic Approach
Cerebral palsy (CP) is a term employed to define a group of non-progressive neuromotor disorders caused by damage to the immature or developing brain, with consequent limitations regarding movement and posture. CP may impair orapharygeal muscle tone, leading to a compromised chewing function and to sleep disorders (such as obstructive sleep apnea). Thirteen adults with CP underwent bilateral masseter and temporalis neuromuscular electrical stimulation (NMES) therapy. The effects on the masticatory muscles and sleep variables were evaluated using electromyography (EMG) and polysomnography (PSG), respectively, prior and after 2 months of NMES. EMG consisted of 3 tests in different positions: rest, mouth opening and maximum clenching effort (MCE). EMG values in the rest position were 100% higher than values recorded prior to therapy for all muscles analyzed (p < 0.05); mean mouth opening increased from 38.0 ± 8.0 to 44.0 ± 10.0 cm (p = 0.03). A significant difference in MCE was found only for the right masseter. PSG revealed an improved in the AHI from 7.2±7.0/h to 2.3±1.5/h (p < 0.05); total sleep time improved from 185 min to 250 min (p = 0.04) and minimun SaO2 improved from 83.6 ± 3.0 to 86.4 ± 4.0 (p = 0.04). NMES performed over a two-month period led to improvements in the electrical activity of the masticatory muscles at rest, mouth opening, isometric contraction and sleep variables, including the elimination of obstructive sleep apnea events in patients with CP. ReBEC RBR994XFS http://www.ensaiosclinicos.gov.br
- 6 August 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (8) , e0128959
Open AccessEffects of Neuromuscular Electrical Stimulation on the Masticatory Muscles and Physiologic Sleep Variables in Adults with Cerebral Palsy: A Novel Therapeutic Approach
Cerebral palsy (CP) is a term employed to define a group of non-progressive neuromotor disorders caused by damage to the immature or developing brain, with consequent limitations regarding movement and posture. CP may impair orapharygeal muscle tone, leading to a compromised chewing function and to sleep disorders (such as obstructive sleep apnea). Thirteen adults with CP underwent bilateral masseter and temporalis neuromuscular electrical stimulation (NMES) therapy. The effects on the masticatory muscles and sleep variables were evaluated using electromyography (EMG) and polysomnography (PSG), respectively, prior and after 2 months of NMES. EMG consisted of 3 tests in different positions: rest, mouth opening and maximum clenching effort (MCE). EMG values in the rest position were 100% higher than values recorded prior to therapy for all muscles analyzed (p < 0.05); mean mouth opening increased from 38.0 ± 8.0 to 44.0 ± 10.0 cm (p = 0.03). A significant difference in MCE was found only for the right masseter. PSG revealed an improved in the AHI from 7.2±7.0/h to 2.3±1.5/h (p < 0.05); total sleep time improved from 185 min to 250 min (p = 0.04) and minimun SaO2 improved from 83.6 ± 3.0 to 86.4 ± 4.0 (p = 0.04). NMES performed over a two-month period led to improvements in the electrical activity of the masticatory muscles at rest, mouth opening, isometric contraction and sleep variables, including the elimination of obstructive sleep apnea events in patients with CP. ReBEC RBR994XFS http://www.ensaiosclinicos.gov.br
- 1 December 2014
- Published by Elsevier in Archives of Oral Biology
- Vol. 59 (12) , 1352-1358
Test–retest reliability of electromyographic variables of masseter and temporal muscles in patients with cerebral palsy
- 1 December 2014
- Published by Elsevier in Archives of Oral Biology
- Vol. 59 (12) , 1352-1358
Test–retest reliability of electromyographic variables of masseter and temporal muscles in patients with cerebral palsy
- 16 October 2014
- Published by Taylor & Francis in Cranio®
- Vol. 33 (3) , 169-173
Effect of a rapid maxillary expansion on snoring and sleep in children: a pilot study
The aim of this study was to assess the efficacy of the McNamara rapid palatal expansion device for the treatment of sleep disorders in children.
- 16 October 2014
- Published by Taylor & Francis in Cranio®
- Vol. 33 (3) , 169-173
Effect of a rapid maxillary expansion on snoring and sleep in children: a pilot study
The aim of this study was to assess the efficacy of the McNamara rapid palatal expansion device for the treatment of sleep disorders in children.
- 1 January 2014
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 18 (1) , 62-67
Effect of a hyperbolide mastication apparatus for the treatment of severe sleep bruxism in a child with cerebral palsy: Long-term follow-up
- 1 January 2014
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 18 (1) , 62-67
Effect of a hyperbolide mastication apparatus for the treatment of severe sleep bruxism in a child with cerebral palsy: Long-term follow-up
- Open Access
- 8 October 2013
- Published by Springer Nature in BMC Nephrology
- Vol. 14 (1) , 1-10
Cardiovascular risk and mortality in end-stage renal disease patients undergoing dialysis: sleep study, pulmonary function, respiratory mechanics, upper airway collapsibility, autonomic nervous activity, depression, anxiety, stress and quality of life: a prospective, double blind, randomized controlled clinical trial
Chronic kidney disease (CKD) is one of the most serious public health problems. The increasing prevalence of CKD in developed and developing countries has led to a global epidemic. The hypothesis proposed is that patients undergoing dialysis would experience a marked negative influence on physiological variables of sleep and autonomic nervous system activity, compromising quality of life. A prospective, consecutive, double blind, randomized controlled clinical trial is proposed to address the effect of dialysis on sleep, pulmonary function, respiratory mechanics, upper airway collapsibility, autonomic nervous activity, depression, anxiety, stress and quality of life in patients with CKD. The measurement protocol will include body weight (kg); height (cm); body mass index calculated as weight/height2; circumferences (cm) of the neck, waist, and hip; heart and respiratory rates; blood pressures; Mallampati index; tonsil index; heart rate variability; maximum ventilatory pressures; negative expiratory pressure test, and polysomnography (sleep study), as well as the administration of specific questionnaires addressing sleep apnea, excessive daytime sleepiness, depression, anxiety, stress, and quality of life. CKD is a major public health problem worldwide, and its incidence has increased in part by the increased life expectancy and increasing number of cases of diabetes mellitus and hypertension. Sleep disorders are common in patients with renal insufficiency. Our hypothesis is that the weather weight gain due to volume overload observed during interdialytic period will influence the degree of collapsibility of the upper airway due to narrowing and predispose to upper airway occlusion during sleep, and to investigate the negative influences of haemodialysis in the physiological variables of sleep, and autonomic nervous system, and respiratory mechanics and thereby compromise the quality of life of patients. The protocol for this study is registered with the Brazilian Registry of Clinical Trials (ReBEC RBR-7yhr4w and World Health Organization under Universal Trial Number UTN: U1111-1127-9390 [ http://www.ensaiosclinicos.gov.br/rg/RBR-7yhr4w/ ]).
- 8 October 2013
- Published by Springer Nature in BMC Nephrology
- Vol. 14 (1) , 1-10
Open AccessCardiovascular risk and mortality in end-stage renal disease patients undergoing dialysis: sleep study, pulmonary function, respiratory mechanics, upper airway collapsibility, autonomic nervous activity, depression, anxiety, stress and quality of life: a prospective, double blind, randomized controlled clinical trial
Chronic kidney disease (CKD) is one of the most serious public health problems. The increasing prevalence of CKD in developed and developing countries has led to a global epidemic. The hypothesis proposed is that patients undergoing dialysis would experience a marked negative influence on physiological variables of sleep and autonomic nervous system activity, compromising quality of life. A prospective, consecutive, double blind, randomized controlled clinical trial is proposed to address the effect of dialysis on sleep, pulmonary function, respiratory mechanics, upper airway collapsibility, autonomic nervous activity, depression, anxiety, stress and quality of life in patients with CKD. The measurement protocol will include body weight (kg); height (cm); body mass index calculated as weight/height2; circumferences (cm) of the neck, waist, and hip; heart and respiratory rates; blood pressures; Mallampati index; tonsil index; heart rate variability; maximum ventilatory pressures; negative expiratory pressure test, and polysomnography (sleep study), as well as the administration of specific questionnaires addressing sleep apnea, excessive daytime sleepiness, depression, anxiety, stress, and quality of life. CKD is a major public health problem worldwide, and its incidence has increased in part by the increased life expectancy and increasing number of cases of diabetes mellitus and hypertension. Sleep disorders are common in patients with renal insufficiency. Our hypothesis is that the weather weight gain due to volume overload observed during interdialytic period will influence the degree of collapsibility of the upper airway due to narrowing and predispose to upper airway occlusion during sleep, and to investigate the negative influences of haemodialysis in the physiological variables of sleep, and autonomic nervous system, and respiratory mechanics and thereby compromise the quality of life of patients. The protocol for this study is registered with the Brazilian Registry of Clinical Trials (ReBEC RBR-7yhr4w and World Health Organization under Universal Trial Number UTN: U1111-1127-9390 [ http://www.ensaiosclinicos.gov.br/rg/RBR-7yhr4w/ ]).
- 1 October 2013
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 17 (4) , 418-422
Effect of an occlusal splint on sleep bruxism in children in a pilot study with a short-term follow up
- 1 October 2013
- Published by Elsevier in Journal of Bodywork and Movement Therapies
- Vol. 17 (4) , 418-422
Effect of an occlusal splint on sleep bruxism in children in a pilot study with a short-term follow up
- 1 July 2013
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 26 (4) , 334-339
Efficacy of an Oral Appliance for the Treatment of Obstructive Sleep Apnea
Lilian Chrystiane Giannasi, PhD/Fernanda Ribeiro Almeida, PhD/Sergio Roberto Nacif, PhD/Luis Vicente Franco de Oliveira, PhD: Purpose: The aim of this study was to validate the use of a mandibular repositioner appliance (MRA) to treat obstructive sleep apnea (OSA) and primary snoring, comparing polysomnographic and Epworth Sleepiness Scale (ESS) data obtained prior to and during MRA treatment. Materials and Methods: Sixty-three patients who presented with different degrees of OSA severity or primary snoring were fitted to a PM positioner between 2009 and 2011. The diagnosis was established by a polysomnogram (PSG) prior to treatment and after 6 months to verify the efficacy of MRA therapy. Subjective daytime sleepiness was evaluated by ESS questionnaire prior to treatment and at the follow-up. Results: Patients were divided into primary snoring and OSA groups. For the primary snoring group, PSG variables did not show significant results, except for a decrease in snoring. For the OSA group, the mean apnea-hypopnea index (AHI) was reduced from 23.0 ? 11 to 5.3 ? 4.0 and median ESS reduced significantly from 13.0 to 8.5. Complete response (AHI < 5) was found in 25 (40%) patients and partial response (AHI ≤ 10) in 27 (43%) patients. Conclusion: The findings validate the efficacy of the adjustable PM positioner for the safe treatment of OSA. Int J Prosthodont 2013;26:334?339. doi: 10.11607/ijp.3284
- 1 July 2013
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 26 (4) , 334-339
Efficacy of an Oral Appliance for the Treatment of Obstructive Sleep Apnea
Lilian Chrystiane Giannasi, PhD/Fernanda Ribeiro Almeida, PhD/Sergio Roberto Nacif, PhD/Luis Vicente Franco de Oliveira, PhD: Purpose: The aim of this study was to validate the use of a mandibular repositioner appliance (MRA) to treat obstructive sleep apnea (OSA) and primary snoring, comparing polysomnographic and Epworth Sleepiness Scale (ESS) data obtained prior to and during MRA treatment. Materials and Methods: Sixty-three patients who presented with different degrees of OSA severity or primary snoring were fitted to a PM positioner between 2009 and 2011. The diagnosis was established by a polysomnogram (PSG) prior to treatment and after 6 months to verify the efficacy of MRA therapy. Subjective daytime sleepiness was evaluated by ESS questionnaire prior to treatment and at the follow-up. Results: Patients were divided into primary snoring and OSA groups. For the primary snoring group, PSG variables did not show significant results, except for a decrease in snoring. For the OSA group, the mean apnea-hypopnea index (AHI) was reduced from 23.0 ? 11 to 5.3 ? 4.0 and median ESS reduced significantly from 13.0 to 8.5. Complete response (AHI < 5) was found in 25 (40%) patients and partial response (AHI ≤ 10) in 27 (43%) patients. Conclusion: The findings validate the efficacy of the adjustable PM positioner for the safe treatment of OSA. Int J Prosthodont 2013;26:334?339. doi: 10.11607/ijp.3284