NJNoo Li Jeon

Noo Li Jeon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Noo Li Jeon has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Seog Woo Rhee

    Department of Biomedical Engineering, University of California, Irvine, 204 Rockwell Engineering, Irvine, 92697, California, USA

    5 shared publications
  • Francis Lin

    Department of Physics and Astronomy, University of Manitoba, Winnipeg, Canada

    4 shared publications
  • Wajeeh Saadi

    Department of Biomedical Engineering, 3120 Natural Sciences II, University of California at Irvine, Irvine, California 92697; telephone: 949-824-9032; fax: 949-824-1727

    4 shared publications
  • Anne Marion Taylor

    UNC/NC State Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill, Chapel Hill, NC, United States

    3 shared publications
  • Carl Cotman

    Institute for Brain Aging and Dementia, University of California, Irvine

    3 shared publications
  • David Cribbs

    Institute for Brain Aging and Dementia, University of California, Irvine

    3 shared publications

Latest Publications

  • Concentration Gradient Generation and Control

    by Jeong Won Park, Hwa Sung Shin, Hyung Joon Kim, Noo Li Jeon

  • Concentration Gradient Generation and Control

    by Jeong Won Park, Hwa Sung Shin, Hyung Joon Kim, Noo Li Jeon

  • Engineering microscale cellular niches for three-dimensional multicellular co-cultures

    by Carlos P. Huang, Jente Lu, Hyeryung Seon, Abraham P. Lee, Lisa A. Flanagan, Ho-Young Kim, Andrew J. Putnam, Noo Li Jeon

    Modeling the in vivo microenvironment typically involves placing cells in a three-dimensional (3D) extracellular matrix (ECM) in physiologically relevant context with respect to other cells. The mechanical and chemical features of 3D microenvironments play important roles in tissue engineering, tumor growth and metastasis, and in defining stem cell niches, and it is increasingly recognized that cells behave much differently when surrounded by a 3D ECM than when anchored to a 2D substrate. To create microenvironments that more closely mimic in vivo settings, here we describe a novel microfluidic device that allows multiple discrete constructs of 3D cell-laden hydrogels to be patterned in a sequence of simple steps. The microfluidic platform allows for real-time imaging of the interactions between multiple cell types exposed to both autocrine and paracrine signaling molecules, all within a 3D ECM environment. Detailed modeling determined that surface tension, hydrophobic interactions, and spatial geometry were important factors in containing the gels within distinct separate channels during the filling process. This allowed us to pattern multiple gel types side-by-side and pattern 3D gels spatially with tight dimensional control. Cells embedded in gels could be patterned by culturing MDA-MB-231 metastatic breast cancer cells and RAW 264.1 macrophage cells within distinct collagen type I and Matrigel ECM environments, respectively. Over a 7 day culture experiment, RAW cells invaded into neighboring gels containing MDA-MB-231 cells, but not into gels lacking cells. These studies demonstrate the versatility and potential of this new microfluidic platform to engineer 3D microscale architectures to investigate cell–cell and cell–matrix interactions.


  • Epidermal growth factor promotes breast cancer cell chemotaxis in CXCL12 gradients

    by Bobak Mosadegh, Wajeeh Saadi, Shur‐Jen Wang, Noo Li Jeon

    The chemokine receptor CXCR4 and its ligand CXCL12 play an important role in breast cancer invasion and metastasis, and induce the chemotaxis of various types of cancer cells. Previous studies of CXCL12‐induced chemotaxis have, for the most part, relied on endpoint assays (e.g., transwell assays) that provide poor control over the cell microenvironment. Specifically, these assays lacked the ability to dissect the role that autocrine and paracrine growth factors play in chemokine‐induced cancer cell chemotaxis. Here, we employ a microfluidic chemotaxis chamber that allows the effects of specific exogenous factors on cell migration to be directly characterized, without the interference of autocrine/paracrine signaling. Using this approach, we investigated the migration of MDA‐MB‐231 breast cancer cells in well‐defined CXCL12 gradients. We found that CXCL12 alone failed to stimulate chemotaxis of these cells; however, when the CXCL12 gradient was supplemented with a uniform stimulus of either EGF or conditioned media, a directional response was induced. This dependence on growth factor signaling points to the importance of autocrine and paracrine factors in determining the migratory response of the cells, and may play an important role in cancer metastasis. Biotechnol. Bioeng. 2008;100: 1205–1213.


  • Open Access

    Non-plasma Bonding of PDMS for Inexpensive Fabrication of Microfluidic Devices

    by Joseph Harris, Hyuna Lee, Behrad Vahidi, Cristina Tu, David Cribbs, Carl Cotman, Noo Li Jeon

    In this video we demonstrate how to use the neuron microfluidic device without plasma bonding.


  • Open Access

    Preparing E18 Cortical Rat Neurons for Compartmentalization in a Microfluidic Device

    by Joseph Harris, Hyuna Lee, Christina Tu Tu, David Cribbs, Carl Cotman, Noo Li Jeon

    In this video we demonstrate the preparation of E18 Cortical Rat Neurons.


  • Open Access

    A hybrid microfluidic-vacuum device for direct interfacing with conventional cell culture methods

    by Bong Geun Chung, Jeong Won Park, Jia Sheng Hu, Carlos Huang, Edwin S Monuki, Noo Li Jeon

    Background: Microfluidics is an enabling technology with a number of advantages over traditional tissue culture methods when precise control of cellular microenvironment is required. However, there are a number of practical and technical limitations that impede wider implementation in routine biomedical research. Specialized equipment and protocols required for fabrication and setting up microfluidic experiments present hurdles for routine use by most biology laboratories.Results: We have developed and validated a novel microfluidic device that can directly interface with conventional tissue culture methods to generate and maintain controlled soluble environments in a Petri dish. It incorporates separate sets of fluidic channels and vacuum networks on a single device that allows reversible application of microfluidic gradients onto wet cell culture surfaces. Stable, precise concentration gradients of soluble factors were generated using simple microfluidic channels that were attached to a perfusion system. We successfully demonstrated real-time optical live/dead cell imaging of neural stem cells exposed to a hydrogen peroxide gradient and chemotaxis of metastatic breast cancer cells in a growth factor gradient.Conclusion: This paper describes the design and application of a versatile microfluidic device that can directly interface with conventional cell culture methods. This platform provides a simple yet versatile tool for incorporating the advantages of a microfluidic approach to biological assays without changing established tissue culture protocols.


  • Open Access

    Fabrication of a Microfluidic Device for the Compartmentalization of Neuron Soma and Axons

    by Joseph Harris, Hyuna Lee, Behrad Vahidi, Christina Tu, David Cribbs, Noo Li Jeon, Carl Cotman

    In this video we demonstrate the technique of soft lithography with polydimethyl siloxane (PDMS) which we use to farbricate a...


  • A microfluidic multi-injector for gradient generation

    by Bong Geun Chung, Francis Lin, Noo Li Jeon

    This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.


  • Top Cited Papers

    A microfluidic culture platform for CNS axonal injury, regeneration and transport

    by Anne M Taylor, Mathew Blurton-Jones, Seog Woo Rhee, David H Cribbs, Carl W Cotman, Noo Li Jeon

    Investigation of axonal biology in the central nervous system (CNS) is hindered by a lack of an appropriate in vitro method to probe axons independently from cell bodies. Here we describe a microfluidic culture platform that polarizes the growth of CNS axons into a fluidically isolated environment without the use of targeting neurotrophins. In addition to its compatibility with live cell imaging, the platform can be used to (i) isolate CNS axons without somata or dendrites, facilitating biochemical analyses of pure axonal fractions and (ii) localize physical and chemical treatments to axons or somata. We report the first evidence that presynaptic (Syp) but not postsynaptic (Camk2a) mRNA is localized to developing rat cortical and hippocampal axons. The platform also serves as a straightforward, reproducible method to model CNS axonal injury and regeneration. The results presented here demonstrate several experimental paradigms using the microfluidic platform, which can greatly facilitate future studies in axonal biology.