C. Raman Suri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
C. Raman Suri has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Priyanka Sharma
CSIR-Institute of Microbial Technology, Sector 39-A, Chandigarh 160036, India
8 shared publicationsVijayender Bhalla
CSIR-Institute of Microbial Technology, Chandigarh-160036, India
7 shared publications- Gajendra S. Shekhawat
Northwestern University
4 shared publications Manil Kukkar
Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030, India; Academy of Scientific and Innovative Research, CSIR-CSIO, Sector 30-C, Chandigarh, 160030, India
4 shared publicationsSatish K. Tuteja
Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030, India; Academy of Scientific and Innovative Research, CSIR-CSIO, Sector 30-C, Chandigarh, 160030, India; CSIR-Institute of Microbial Technology (CSIR-IMTECH), Sector 39, Chandigarh, 160038, India
4 shared publicationsAdity Chopra
Institute of Microbial Technology (CSIR) Sector-39A, Chandigarh-160036, India
3 shared publications
Latest Publications
- 6 March 2017
- Published by Springer Nature in Microchimica Acta
- Vol. 184 (5) , 1499-1508
Selective identification of specific aptamers for the detection of non-typhoidal salmonellosis in an apta-impedimetric sensing format
- 6 March 2017
- Published by Springer Nature in Microchimica Acta
- Vol. 184 (5) , 1499-1508
Selective identification of specific aptamers for the detection of non-typhoidal salmonellosis in an apta-impedimetric sensing format
- 1 December 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 86, 548-556
A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs)
- 1 December 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 86, 548-556
A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs)
- 1 November 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 85, 707-713
Novel surface antigen based impedimetric immunosensor for detection of Salmonella typhimurium in water and juice samples
- 1 November 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 85, 707-713
Novel surface antigen based impedimetric immunosensor for detection of Salmonella typhimurium in water and juice samples
- 5 August 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (79) , 75862-75869
Label-free electrochemical detection of malaria-infected red blood cells
The precise and rapid diagnosis of malaria is key to prevent indiscriminate use of antimalarial drugs and help in timely treatment and management of the disease. This paper reports a label-free detection of P. falciparum infected red blood cells using a gold nanoparticle (GNP) enhanced platform. The GNPs were electrodeposited on screen-printed electrodes to form a well-controlled matrix that served the dual role of antibody immobilization and signal enhancement. The detection of infected red blood cells was carried out by measuring changes in electrical parameters as a result of its binding to cell reactive antibodies immobilized on the electrode. The assay showed good sensitivity and a linear response between the electron transfer resistance and the logarithm of the number of infected red blood cells which was observed over a concentration range of 102 cells per mL to 108 cells per mL. This is the first report where an antibody-functionalized electrochemical biosensing platform has been employed for the quantitative detection of P. falciparum infected whole red blood cells.
- 5 August 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (79) , 75862-75869
Label-free electrochemical detection of malaria-infected red blood cells
The precise and rapid diagnosis of malaria is key to prevent indiscriminate use of antimalarial drugs and help in timely treatment and management of the disease. This paper reports a label-free detection of P. falciparum infected red blood cells using a gold nanoparticle (GNP) enhanced platform. The GNPs were electrodeposited on screen-printed electrodes to form a well-controlled matrix that served the dual role of antibody immobilization and signal enhancement. The detection of infected red blood cells was carried out by measuring changes in electrical parameters as a result of its binding to cell reactive antibodies immobilized on the electrode. The assay showed good sensitivity and a linear response between the electron transfer resistance and the logarithm of the number of infected red blood cells which was observed over a concentration range of 102 cells per mL to 108 cells per mL. This is the first report where an antibody-functionalized electrochemical biosensing platform has been employed for the quantitative detection of P. falciparum infected whole red blood cells.
- 9 October 2015
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (107) , 88234-88240
Anodic stripping voltammetry of anti-Vi antibody functionalized CdTe quantum dots for the specific monitoring of Salmonella enterica serovar Typhi
CdTe QD based stripping voltammetry for Vi capsular polysaccharide detection. The technique has provided an insight into the competence of CdTe QD and GNP immuno-conjugates. This is a novel approach to characterize the efficiency of immuno-conjugates of QDs and GNPs.
- 9 October 2015
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (107) , 88234-88240
Anodic stripping voltammetry of anti-Vi antibody functionalized CdTe quantum dots for the specific monitoring of Salmonella enterica serovar Typhi
CdTe QD based stripping voltammetry for Vi capsular polysaccharide detection. The technique has provided an insight into the competence of CdTe QD and GNP immuno-conjugates. This is a novel approach to characterize the efficiency of immuno-conjugates of QDs and GNPs.
- 1 April 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 66, 129-135
One step in-situ synthesis of amine functionalized graphene for immunosensing of cardiac marker cTnI
- 1 April 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 66, 129-135
One step in-situ synthesis of amine functionalized graphene for immunosensing of cardiac marker cTnI
- 1 September 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 841, 51-57
Immuno-fluorescence based Vi capsular polysaccharide detection for specific recognition of Salmonella enterica serovar Typhi in clinical samples
- 1 September 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 841, 51-57
Immuno-fluorescence based Vi capsular polysaccharide detection for specific recognition of Salmonella enterica serovar Typhi in clinical samples
- 19 February 2014
- Published by Wiley in Electroanalysis
- Vol. 26 (3) , 469-472
Point‐of‐Care Amperometric Testing of Diabetic Marker (HbA1c) Using Specific Electroactive Antibodies
Specific immune detection of glycated hemoglobin is still a great challenge owing to the small epitopic difference between Hemoglobin (Hb) and HbA1c. We report a new electrochemical immunoassay format for point of care testing of HbA1c. A conducting self‐assembled monolayer of mercaptophenyl boronic acid (MPBA) was used as a capture layer for binding of glycated proteins and ferrocene tagged anti‐HbA1c antibody (FcAb) as a tracer molecule on a gold screen printed electrode. Validation of the new HbA1c assay was carried out using 6 clinical samples with known HPLC values and a correlation coefficient of 98 % was observed.
- 19 February 2014
- Published by Wiley in Electroanalysis
- Vol. 26 (3) , 469-472
Point‐of‐Care Amperometric Testing of Diabetic Marker (HbA1c) Using Specific Electroactive Antibodies
Specific immune detection of glycated hemoglobin is still a great challenge owing to the small epitopic difference between Hemoglobin (Hb) and HbA1c. We report a new electrochemical immunoassay format for point of care testing of HbA1c. A conducting self‐assembled monolayer of mercaptophenyl boronic acid (MPBA) was used as a capture layer for binding of glycated proteins and ferrocene tagged anti‐HbA1c antibody (FcAb) as a tracer molecule on a gold screen printed electrode. Validation of the new HbA1c assay was carried out using 6 clinical samples with known HPLC values and a correlation coefficient of 98 % was observed.
- 1 January 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 809, 148-154
Graphene-gated biochip for the detection of cardiac marker Troponin I
- 1 January 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 809, 148-154
Graphene-gated biochip for the detection of cardiac marker Troponin I
- 19 November 2013
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 50 (9) , 1080-1082
Nanobioprobe mediated DNA aptamers for explosive detection
Specific nucleic acid aptamers using the microtiter plate based modified SELEX method against explosive trinitrotoluene are reported. Efficient partitioning of dsDNA was carried out using streptavidin labeled gold nanoprobes for the selection of specific aptamers. The selected binders having an affinity of ∼10−7 M were used in the newly developed electrochemical aptasensor, exhibiting a detection limit of around 1 ppb for trinitrotoluene.
- 19 November 2013
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 50 (9) , 1080-1082
Nanobioprobe mediated DNA aptamers for explosive detection
Specific nucleic acid aptamers using the microtiter plate based modified SELEX method against explosive trinitrotoluene are reported. Efficient partitioning of dsDNA was carried out using streptavidin labeled gold nanoprobes for the selection of specific aptamers. The selected binders having an affinity of ∼10−7 M were used in the newly developed electrochemical aptasensor, exhibiting a detection limit of around 1 ppb for trinitrotoluene.