Hajime Kurosawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hajime Kurosawa has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Etsuhiro Nikkuni
Department of Occupational Health, Tohoku University Graduate School of Medicine, Japan
2 shared publicationsHiromasa Ogawa
Department of Occupational Health, Tohoku University Graduate School of Medicine, Japan; Center for Environmental Conservation and Research Safety, Tohoku University, Japan
2 shared publications- Hiromasa Ogawa
Department of Occupational Health, Tohoku University Graduate School of Medicine, Japan
2 shared publications Ritsuko Arakawa
Department of Occupational Health, Tohoku University Graduate School of Medicine, Japan
2 shared publications- Shinya Ohkouchi
Department of Occupational Health, Tohoku University Graduate School of Medicine, Japan
2 shared publications Toshiya Irokawa
Department of Occupational Health, Tohoku University Graduate School of Medicine, Japan; Center for Environmental Conservation and Research Safety, Tohoku University, Japan
2 shared publications
Latest Publications
- Open Access
- 21 May 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (10) , 6275
Association between Fathers’ Use of Heated Tobacco Products and Urinary Cotinine Concentrations in Their Spouses and Children
Heated tobacco products (HTPs) have become increasingly popular among smokers, especially among young adults in Japan in recent years. Assessments of secondhand tobacco smoke (SHS) exposure due to HTPs are scarce. The present study aimed to assess the urinary levels of total nicotine metabolites (TNMs) of non-smoking spouses and their children following SHS exposure due to their fathers’ use of HTPs. A total of 41 families including 129 participants were recruited between 2018 and 2021. The number of non-smoking spouses and children of the fathers who smoke combustion cigarettes, the fathers who use HTPs, and the fathers who are non-users or have never smoked was 27, 66, and 36, respectively. The urinary levels of TNMs, including cotinine (Cot) and 3′-hydroxycotinine (3-OHCot), were measured using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The spouses and children of fathers who use HTPs had significantly higher levels of TNMs in their urine compared to those with fathers who were non-smokers or non-users. The current study is the first to assess SHS exposure due to HTP use, and to suggest the importance of strategies to prevent exposure to SHS from HTP use in public places and educational strategies to protect non-smokers from secondhand HTP aerosol exposure in households and other private places.
- 21 May 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (10) , 6275
Open AccessAssociation between Fathers’ Use of Heated Tobacco Products and Urinary Cotinine Concentrations in Their Spouses and Children
Heated tobacco products (HTPs) have become increasingly popular among smokers, especially among young adults in Japan in recent years. Assessments of secondhand tobacco smoke (SHS) exposure due to HTPs are scarce. The present study aimed to assess the urinary levels of total nicotine metabolites (TNMs) of non-smoking spouses and their children following SHS exposure due to their fathers’ use of HTPs. A total of 41 families including 129 participants were recruited between 2018 and 2021. The number of non-smoking spouses and children of the fathers who smoke combustion cigarettes, the fathers who use HTPs, and the fathers who are non-users or have never smoked was 27, 66, and 36, respectively. The urinary levels of TNMs, including cotinine (Cot) and 3′-hydroxycotinine (3-OHCot), were measured using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The spouses and children of fathers who use HTPs had significantly higher levels of TNMs in their urine compared to those with fathers who were non-smokers or non-users. The current study is the first to assess SHS exposure due to HTP use, and to suggest the importance of strategies to prevent exposure to SHS from HTP use in public places and educational strategies to protect non-smokers from secondhand HTP aerosol exposure in households and other private places.
- 13 February 2019
- Published by Elsevier in Respiratory Investigation
- Vol. 57 (3) , 274-281
Respiratory resistance among adults in a population-based cohort study in Northern Japan
- 13 February 2019
- Published by Elsevier in Respiratory Investigation
- Vol. 57 (3) , 274-281
Respiratory resistance among adults in a population-based cohort study in Northern Japan
- Open Access
- 1 May 2015
- Published by Elsevier in Molecular Therapy
- Vol. 23, S15
35. Mesenchymal Stem Cells Reduce Endoplasmic Reticulum (ER) Stress and Correct Inappropriate Epithelial Mesenchyme Relation in Pulmonary Fibrosis Using Stanniocalcin-1
- 1 May 2015
- Published by Elsevier in Molecular Therapy
- Vol. 23, S15
Open Access35. Mesenchymal Stem Cells Reduce Endoplasmic Reticulum (ER) Stress and Correct Inappropriate Epithelial Mesenchyme Relation in Pulmonary Fibrosis Using Stanniocalcin-1
- 1 January 2015
- Published by Japan Society for Occupational Health in SANGYO EISEIGAKU ZASSHI
- Vol. 57 (2) , 37-39
The workplace patrol reported in the disaster waste treatment plants at the Great East Japan Earthquake disaster area
- 1 January 2015
- Published by Japan Society for Occupational Health in SANGYO EISEIGAKU ZASSHI
- Vol. 57 (2) , 37-39
The workplace patrol reported in the disaster waste treatment plants at the Great East Japan Earthquake disaster area
- 1 January 2014
- Published by Elsevier in Respiratory Investigation
- Vol. 52 (1) , 57-64
Evaluation of airway responsiveness using colored three-dimensional analyses of a new forced oscillation technique in controlled asthmatic and nonasthmatic children
- 1 January 2014
- Published by Elsevier in Respiratory Investigation
- Vol. 52 (1) , 57-64
Evaluation of airway responsiveness using colored three-dimensional analyses of a new forced oscillation technique in controlled asthmatic and nonasthmatic children
- Open Access
Application of impulse oscillometry for within-breath analysis in patients with chronic obstructive pulmonary disease: pilot study
Background The impulse oscillometry is increasingly used for assessing the oscillatory mechanics of the respiratory system. The within-breath behaviour of the oscillatory mechanics in chronic obstructive pulmonary disease (COPD) is a well-known physiological feature. The purpose of this study was to develop a new approach for assessing this feature using impulse oscillometry. Methods The oscillatory mechanics were assessed by a commercially available impulse oscillometry device. The respiratory system resistance (Rrs) and reactance (Xrs) were measured during tidal breathing in patients with COPD (n=39) and healthy subjects (n=5). Selected data, the Rrs at 5 Hz (R5), Rrs at 20 Hz (R20), Xrs at 5 Hz (X5), and resonant frequency of Xrs (Fres) every 0.2 s, were extracted from the device. These data were divided into eight time fractions during the respiratory cycle to form averaged respiratory phases. Results The time courses of the R5 and X5 were notably dependent on the respiratory cycles in patients with COPD, while there was little such dependency in healthy subjects. Irrespective of respiratory phase, R5 and Fres increased, and X5 fell to a more negative level in patients with COPD in a severity-dependent fashion. The increase in the R5 and negative level in the X5 were more prominent in the middle of the expiratory phase. The severity dependence in the R20 was relatively small compared with that in the R5. Conclusions The results of this study suggest that impulse oscillometry can assess the within-breath behaviour of the oscillatory mechanics with high temporal resolution, which may be helpful for evaluating the severity of COPD. Further studies are needed to reveal which biomarkers obtained with this approach would be suitable for evaluating the airway obstruction.
Open AccessApplication of impulse oscillometry for within-breath analysis in patients with chronic obstructive pulmonary disease: pilot study
Background The impulse oscillometry is increasingly used for assessing the oscillatory mechanics of the respiratory system. The within-breath behaviour of the oscillatory mechanics in chronic obstructive pulmonary disease (COPD) is a well-known physiological feature. The purpose of this study was to develop a new approach for assessing this feature using impulse oscillometry. Methods The oscillatory mechanics were assessed by a commercially available impulse oscillometry device. The respiratory system resistance (Rrs) and reactance (Xrs) were measured during tidal breathing in patients with COPD (n=39) and healthy subjects (n=5). Selected data, the Rrs at 5 Hz (R5), Rrs at 20 Hz (R20), Xrs at 5 Hz (X5), and resonant frequency of Xrs (Fres) every 0.2 s, were extracted from the device. These data were divided into eight time fractions during the respiratory cycle to form averaged respiratory phases. Results The time courses of the R5 and X5 were notably dependent on the respiratory cycles in patients with COPD, while there was little such dependency in healthy subjects. Irrespective of respiratory phase, R5 and Fres increased, and X5 fell to a more negative level in patients with COPD in a severity-dependent fashion. The increase in the R5 and negative level in the X5 were more prominent in the middle of the expiratory phase. The severity dependence in the R20 was relatively small compared with that in the R5. Conclusions The results of this study suggest that impulse oscillometry can assess the within-breath behaviour of the oscillatory mechanics with high temporal resolution, which may be helpful for evaluating the severity of COPD. Further studies are needed to reveal which biomarkers obtained with this approach would be suitable for evaluating the airway obstruction.
- Open Access
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 65
Time lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus.
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 65
Open AccessTime lag between oscillatory pressure and flow affecting accuracy of forced oscillation technique
The forced oscillation technique (FOT) is a simple method for assessing the oscillatory mechanics of the respiratory system. The oscillatory properties, respiratory system resistance (Rrs) and reactance (Xrs), are calculated from the oscillatory pressure/flow relationship. Although the FOT has been a well-established technique, some detailed experimental conditions would be different among institutions. We evaluated whether time lags produced by the experimental conditions such as different positions of the sensors can affect the accuracy of the FOT. If the position of the pressure sensor is different from the flow sensor, a time lag may occur in the measurements. The effect of the time lag was studied by numerical analysis. Rrs was estimated to be increased and Xrs decreased with an increase in the time lag, especially at a high oscillatory frequency of the medium-frequency range (5-35 Hz). At the high-frequency range (10-500 Hz), Rrs and Xrs were strikingly different in the values of the time lag. A time lag between the oscillatory pressure and flow may be involved in the accuracy of the FOT, suggesting that it needs to be minimized or compensated for with signal processing. Researchers should pay attention to such detailed experimental conditions of the FOT apparatus.
- 1 November 2010
- Vol. 58 (11) , 1073-7
[Effect of age on electrocardiogram entropy value of parameters by sleep respiratory disturbance].
Spectral entropy of electrocardiogram (ECG), which was calculated using the MemCalc method with a portable bio-signal measurement instrument (PBSM), might be a possible parameter for evaluating the quality of sleep. This study assessed the effects of ECG spectral entropy on obstructive sleep apnea/hypopnea syndrome (OSAHS) depending on age. ECG was recorded using a PBSM, and the maximum entropy of ECG every 9 RR intervals was calculated. These entropies were compared with the age and sleeping indices obtained with a conventional polysomnography (PSG) system. Seventy-six patients suspected of OSAHS were recorded from 20:00 to 06:00 using a conventional PSG system (Alice III) and a PBSM (MemCalc-Makin2) simultaneously. ECG entropy showed correlations to high frequency (HF, 0.15-0.40 Hz) heart rate variability in the cardiac parasympathetic activity index, as did the ECG entropy value, and a negative correlation was found with the age (r = 0.538, p < 0.0001), and positive correlation with the HF value (r = 0.810, p < 0.0001). The ECG entropy value in subjects aged > or = 40 with no different sleep respiratory disturbance index by PSG data (AHI, Arousal Index, DSI, and sleep efficiency, etc.) to 60 years old was compared with those aged > or = 60. The ECG entropy value and HF value decreased at > or = 60 years old with statistically significant. The value of ECG entropy corresponds to cardiac parasympathetic function, and it decreases according to age (increase by the absolute value).
- 1 November 2010
- Vol. 58 (11) , 1073-7
[Effect of age on electrocardiogram entropy value of parameters by sleep respiratory disturbance].
Spectral entropy of electrocardiogram (ECG), which was calculated using the MemCalc method with a portable bio-signal measurement instrument (PBSM), might be a possible parameter for evaluating the quality of sleep. This study assessed the effects of ECG spectral entropy on obstructive sleep apnea/hypopnea syndrome (OSAHS) depending on age. ECG was recorded using a PBSM, and the maximum entropy of ECG every 9 RR intervals was calculated. These entropies were compared with the age and sleeping indices obtained with a conventional polysomnography (PSG) system. Seventy-six patients suspected of OSAHS were recorded from 20:00 to 06:00 using a conventional PSG system (Alice III) and a PBSM (MemCalc-Makin2) simultaneously. ECG entropy showed correlations to high frequency (HF, 0.15-0.40 Hz) heart rate variability in the cardiac parasympathetic activity index, as did the ECG entropy value, and a negative correlation was found with the age (r = 0.538, p < 0.0001), and positive correlation with the HF value (r = 0.810, p < 0.0001). The ECG entropy value in subjects aged > or = 40 with no different sleep respiratory disturbance index by PSG data (AHI, Arousal Index, DSI, and sleep efficiency, etc.) to 60 years old was compared with those aged > or = 60. The ECG entropy value and HF value decreased at > or = 60 years old with statistically significant. The value of ECG entropy corresponds to cardiac parasympathetic function, and it decreases according to age (increase by the absolute value).