PIPeter Irwin

Peter Irwin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter Irwin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Yiping He

    United States Department of Agriculture

    5 shared publications
  • Andrew G. Gehring

    United States Department of Agriculture, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, PA 19038, USA

    4 shared publications
  • Chin-Yi Chen

    United States Department of Agriculture

    4 shared publications
  • Chin-Yi Chen

    Characterization and Interventions for Foodborne Pathogens Research Unit, Eastern Regional Research Center, Agricultural Research Service, United States Department of Agriculture, 600 East Mermaid Lane, Wyndmoor, PA 19038, USA

    3 shared publications
  • George C. Paoli

    Molecular Characterization of Foodborne Pathogens Research Unit, USDA, Agriculture Research Service, Eastern Regional Research Center, Wyndmoor, Pennsylvania, USA

    3 shared publications
  • Ly-Huong Nguyen

    Molecular Characterization of Foodborne Pathogens Research Unit, Eastern Regional Research Center, Agricultural Research Service, U. S. Department of Agriculture, 600 East Mermaid Lane, Wyndmoor, PA 19038 USA

    3 shared publications

Latest Publications

  • Open Access

    Study on the mechanism of antibacterial action of magnesium oxide nanoparticles against foodborne pathogens

    by Yiping He, Shakuntala Ingudam, Sue Reed, Andrew Gehring, Terence P. Strobaugh, Peter Irwin

    Magnesium oxide nanoparticles (MgO nanoparticles, with average size of 20 nm) have considerable potential as antimicrobial agents in food safety applications due to their structure, surface properties, and stability. The aim of this work was to investigate the antibacterial effects and mechanism of action of MgO nanoparticles against several important foodborne pathogens. Resazurin (a redox sensitive dye) microplate assay was used for measuring growth inhibition of bacteria treated with MgO nanoparticles. The minimal inhibitory concentrations of MgO nanoparticles to 104 colony-forming unit/ml (CFU/ml) of Campylobacter jejuni, Escherichia coli O157:H7, and Salmonella Enteritidis were determined to be 0.5, 1 and 1 mg/ml, respectively. To completely inactivate 108−9 CFU/ml bacterial cells in 4 h, a minimal concentration of 2 mg/ml MgO nanoparticles was required for C. jejuni whereas E. coli O157:H7 and Salmonella Enteritidis required at least 8 mg/ml nanoparticles. Scanning electron microscopy examination revealed clear morphological changes and membrane structural damage in the cells treated with MgO nanoparticles. A quantitative real-time PCR combined with ethidium monoazide pretreatment confirmed cell membrane permeability was increased after exposure to the nanoparticles. In a cell free assay, a low level (1.1 μM) of H2O2 was detected in the nanoparticle suspensions. Consistently, MgO nanoparticles greatly induced the gene expression of KatA, a sole catalase in C. jejuni for breaking down H2O2 to H2O and O2. MgO nanoparticles have strong antibacterial activity against three important foodborne pathogens. The interaction of nanoparticles with bacterial cells causes cell membrane leakage, induces oxidative stress, and ultimately leads to cell death.


  • Open Access

    Antibody Microarray for E. coli O157:H7 and Shiga Toxin in Microtiter Plates

    by Andrew G. Gehring, Jeffrey D. Brewster, Yiping He, Peter L. Irwin, George C. Paoli, Tawana Simons, Shu-I Tu, Joseph Uknalis

    Antibody microarray is a powerful analytical technique because of its inherent ability to simultaneously discriminate and measure numerous analytes, therefore making the technique conducive to both the multiplexed detection and identification of bacterial analytes (i.e., whole cells, as well as associated metabolites and/or toxins). We developed a sandwich fluorescent immunoassay combined with a high-throughput, multiwell plate microarray detection format. Inexpensive polystyrene plates were employed containing passively adsorbed, array-printed capture antibodies. During sample reaction, centrifugation was the only strategy found to significantly improve capture, and hence detection, of bacteria (pathogenic Escherichia coli O157:H7) to planar capture surfaces containing printed antibodies. Whereas several other sample incubation techniques (e.g., static vs. agitation) had minimal effect. Immobilized bacteria were labeled with a red-orange-fluorescent dye (Alexa Fluor 555) conjugated antibody to allow for quantitative detection of the captured bacteria with a laser scanner. Shiga toxin 1 (Stx1) could be simultaneously detected along with the cells, but none of the agitation techniques employed during incubation improved detection of the relatively small biomolecule. Under optimal conditions, the assay had demonstrated limits of detection of ~5.8 × 105 cells/mL and 110 ng/mL for E. coli O157:H7 and Stx1, respectively, in a ~75 min total assay time.


  • Open Access

    The near-quantitative sampling of genomic DNA from various food-borne Eubacteria

    by Peter Irwin, Ly Nguyen, Yiping He, George Paoli, Andrew Gehring, Chin-Yi Chen

    The disruption of the bacterial cell wall plays an important part in achieving quantitative extraction of DNA from Eubacteria essential for accurate analyses of genetic material recovered from environmental samples. In this work we have tested a dozen commercial bacterial genomic DNA extraction methodologies on an average of 7.70 × 106 (±9.05%), 4.77 × 108 (±31.0%), and 5.93 × 108 (±4.69%) colony forming units (CFU) associated with 3 cultures (n = 3) each of Brochothrix thermosphacta (Bt; Gram-positive), Shigella sonnei (Ss; Gram-negative), and Escherichia coli O79 (Ec; Gram-negative). We have utilized real-time PCR (q PCR) quantification with two specific sets of primers associated with the 16S r RNA “gene” to determine the number of copies CFU-1 by comparing the unknown target DNA q PCR results with standards for each primer set. Based upon statistical analyses of our results, we determined that the Agencourt Genfind v2, High Pure PCR Template Prep Kit, and Omnilyse methods consistently provided the best yield of genomic DNA ranging from 141 to 934, 8 to 21, and 16 to 27 16S r DNA copies CFU-1 for Bt, Ss, and Ec. If one assumes 6–7 copies of the 16S r RNA gene per genome, between 1 and 3 genomes per actively dividing cell and ≥ 100 cells CFU-1 for Bt (found to be a reasonable assumption using an optical method expounded upon herein) or between 1 and 2 cells CFU-1 for either Ss or Ec, then the Omnilyse procedure provided nearly quantitative extraction of genomic DNA from these isolates (934 ± 19.9 copies CFU-1 for Bt; 20.8 ± 2.68 copies CFU-1 for Ss; 26.9 ± 3.39 copies CFU-1 for Ec). The Agencourt, High Pure, and Omnilyse technologies were subsequently assessed using 5 additional Gram-positive and 10 Gram-negative foodborne isolates (n = 3) using a set of “universal” 16S r DNA primers. Overall, the most notable DNA extraction method was found to be the Omnilyse procedure which is a “bead blender” technology involving high frequency agitation in the presence of zirconium silicate beads.


  • A method for correcting standard-based real-time PCR DNA quantitation when the standard’s polymerase reaction efficiency is significantly different from that of the unknown’s

    by Peter L. Irwin, Ly-Huong T. Nguyen, Chin-Yi Chen, Gaylen A. Uhlich, George C. Paoli

    Standard-based real-time or quantitative polymerase chain reaction quantitation of an unknown sample’s DNA concentration (i.e., [DNA]unk) assumes that the concentration dependence of the standard and unknown reactions (related to reaction efficiency, E) are equivalent. In our work with background food-borne organisms which can interfere with pathogen detection, we have found that it is generally possible to achieve an acceptable E (1 ± 0.05) for standard solutions by optimizing the PCR conditions, template purity, primer sequence, and amplicon lengths. However, this is frequently not true for the solutions containing unknown amounts of target DNA inasmuch as cell extracts are more chemically complex than the standards which have been amplified (230-fold) as well as undergone a purification process. When significant differences in E occur, it is not possible to accurately estimate unknown target DNA concentration from the standard solution’s slope and intercept (from threshold cycle number, or C T , versus Log[DNA] data). What is needed is a standard-mediated intercept which can be specifically coupled with an unknown solution’s PCR concentration dependence. In this work, we develop a simple mathematical procedure to generate a new standard curve with a slope (∂C T /∂Log[Dilution]unk) derived from at least three dilutions of the unknown target DNA solution ([DNA]unk) and an intercept calculated from the unknown’s C T s, DNA concentrations interpolated from the standard curve (i.e., the traditional estimate of [DNA]unk), and ∂C T /∂Log[Dilution]unk. We were able to achieve this due to our discovery of the predictable way in which the observed and ideal C T versus Log[DNA] slopes and intercepts deviate from one another. This “correction” in the standard-based [DNA]unk determination is typically 20–60% when the difference in the standard and unknown E is >0.1.


  • Open Access

    Evidence for a bimodal distribution of Escherichia coli doubling times below a threshold initial cell concentration

    by Peter L Irwin, Ly-Huong T Nguyen, George C Paoli, Chin-Yi Chen

    In the process of developing a microplate-based growth assay, we discovered that our test organism, a native E. coli isolate, displayed very uniform doubling times (tau) only up to a certain threshold cell density. Below this cell concentration (100 CFU mL-1), the tau values were distributed unimodally (mutau = 18 +/- 0.71 min; n = 174). Inclusion of a small amount of ethyl acetate to the LB caused a collapse of the bimodal to a unimodal form. Comparable bimodal tau distribution results were also observed using E. coli cells diluted from mid-log phase cultures. Similar results were also obtained when using either an E. coli O157:H7 or a Citrobacter strain. When sterile-filtered LB supernatants, which formerly contained relatively low concentrations of bacteria(1,000-10,000 CFU mL-1), were employed as a diluent, there was an evident shift of the two populations towards each other but the bimodal effect was still apparent using either stationary or log phase cells. These data argue that there is a dependence of growth rate on starting cell density.


  • The relationship between purely stochastic sampling error and the number of technical replicates used to estimate concentration at an extreme dilution

    by Peter L. Irwin, Ly-Huong T. Nguyen, Chin-Yi Chen

    For any analytical system the population mean (μ) number of entities (e.g., cells or molecules) per tested volume, surface area, or mass also defines the population standard deviation \( (\sigma = \sqrt {\mu } ) \). For a preponderance of analytical methods, σ is very small relative to μ due to their large limit of detection (>102 per volume). However, in theory at least, DNA-based detection methods (real-time, quantitative or qPCR) can detect ≈ 1 DNA molecule per tested volume (i.e., μ ≈ 1) whereupon errors of random sampling can cause sample means (\( \overline x \)) to substantially deviate from μ if the number of samplings (n), or “technical replicates”, per observation is too small. In this work the behaviors of two measures of sampling error (each replicated fivefold) are examined under the influence of n. For all data (μ = 1.25, 2.5, 5, 7.5, 10, and 20) a large sample of individual analytical counts (x) were created and randomly assigned into N integral-valued sub-samples each containing between 2 and 50 repeats (n) whereupon N × n = 322 to 361. From these data the average μ-normalized deviation of σ from each sub-sample’s standard deviation estimate \(\left( {s_j ;\;j = 1\;{\hbox{to}}\;N;\;N = 7\;\left[ {n = 50} \right]\;{\hbox{to}}\;180\;\left[ {n = 2} \right]} \right)\) was calculated (Δ). Alternatively, the average μ-normalized deviation of μ from each sub-sample’s mean estimate (\( {\overline x_{\rm{j}}} \)) was also evaluated (Δ′). It was found that both of these empirical measures of sampling error were proportional to \( \sqrt[{ - 2}]{{n \cdot \mu }} \). Derivative (∂/∂n · Δ or Δ′) analyses of our results indicate that a large number of samplings \( (n \approx {33}\pm {3}.{1}) \) are requisite to achieve a nominal sampling error for samples with a μ ≈ 1. This result argues that pathogen detection is most economically performed, even using highly sensitive techniques such as qPCR, when some form of organism cultural enrichment is utilized and which results in a binomial response. Thus, using a specific gene PCR-based (+ or −) most probable number (MPN) assay one could detect anywhere from 0.2 to 105 CFU mL−1 using 6 to 48 reactions (i.e., 8 dilutions × 6 replicates per dilution) depending on the initial concentration of the pathogen and volume sampled.


  • Open Access

    Antimicrobial activity of spherical silver nanoparticles prepared using a biocompatible macromolecular capping agent: evidence for induction of a greatly prolonged bacterial lag phase

    by Peter Irwin, Justin Martin, Ly-Huong Nguyen, Yiping He, Andrew Gehring, Chin-Yi Chen

    We have evaluated the antimicrobial properties of Ag-based nanoparticles (Nps) using two solid phase bioassays and found that 10-20 μL of 0.3-3 μM keratin-stabilized Nps (depending on the starting bacterial concentration = C I) completely inhibited the growth of an equivalent volume of ca. 103 to 104 colony forming units per mL (CFU mL-1) Staphylococcus aureus, Salmonella Typhimurium, or Escherichia coli O157:H7 on solid surfaces. Even after one week at 37°C on solid media, no growth was observed. At lower Np concentrations (= [Np]s), visible colonies were observed but they eventually ceased growing.


  • Binding of nontarget microorganisms from food washes to anti-Salmonella and anti-E. coli O157 immunomagnetic beads: most probable composition of background Eubacteria

    by Peter Irwin, Ly-Huong Nguyen, Chin-Yi Chen, George Paoli

    We present herein the composition of bacterial communities occurring in ground chicken and the changes which arise in these populations based upon nonselective partitioning by commercially-available Dynal anti-Salmonella and anti-E. coli O157 immunomagnetic beads (IMB). Our enumeration and colony selection protocol was based upon a 6 × 6 drop plate method (n = 18 for each 25-g sub-sampling) using a dilution which resulted in ca. 4–8 colonies per drop. An average of 82 ± 13 colonies were selected from three 25-g ground chicken subsamplings per batch, each of which was repeated seasonally for one year. DNA was extracted from each colony and the composition of Eubacteria in each of these harvests was determined by sequence-based identification of 16S rDNA amplicons. The Gram-positive bacteria Brochothrix thermosphacta and Carnobacterium maltaromticum were the most commonly found organisms in both the total chicken wash (PBS) and in the IMB-bound (PBS-washed) fractions. The remaining background organisms which also adhered to varying degrees to commercial IMBs were: Pseudomonas oleovorans, Acinetobacter lwoffi, Serratia spp., and one Rahnella spp. A large number of the organisms were also cladistically evaluated based on rDNA basepair disparities: all Brochothrices were monophyletic; twelve different Pseudomonads were found along with eight Carnobacteria, seven Acinetobacteres, four Serratiae, and two Rahnellae. Carnobacterium alone showed an IMB-based concentration enhancement (ca. two to sixfold).