NENina Elmstedt

Nina Elmstedt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nina Elmstedt has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • M. Westgren

    Centre for Fetal Medicine; Karolinska University Hospital; Stockholm Sweden

    3 shared publications
  • B. Lind

    Department of Medical Engineering, School of Technology and Health, Royal Institute of Technology, Stockholm, Sweden

    2 shared publications
  • Britta Bl Lind

    Department of Medical Engineering, School of Technology and Health, KTH Royal Institute of Technology, Alfred Nobels Allé 10, Huddinge 141 52, Sweden

    2 shared publications
  • J. Johnson

    Department of Medical Engineering; School of Technology and Health; KTH Stockholm Sweden

    2 shared publications
  • K. Ferm‐Widlund

    Department of Obstetrics and Gynecology, Center of Fetal Medicine, Karolinska University Hospital, Stockholm, Sweden

    2 shared publications
  • Kjerstin Ferm-Widlund

    Centre for Fetal Medicine, Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm, Sweden.

    2 shared publications

Latest Publications

  • Open Access

    OP02.08: New automatic analysis of tissue Doppler traces for a simplified assessment of fetal cardiac function

    by L. Herling, J. Johnson, K. Ferm-Widlund, N. Elmstedt, P. Lindgren, G. Acharya, M. Westgren

  • Open Access

    Reference values for fetal tissue velocity imaging and a new approach to evaluate fetal myocardial function

    by Nina Ne Elmstedt, Jonas Jj Johnson, Britta Bl Lind, Kjerstin Kfw Ferm-Widlund, Lotta Lh Herling, Magnus Mw Westgren, Lars-Åke Lab Brodin

    Myocardial function can be evaluated using color-coded tissue velocity imaging (TVI) to analyze the longitudinal myocardial velocity profile, and by expressing the motion of the atrioventricular plane during a cardiac cycle as coordinated events in the cardiac state diagram (CSD). The objective of this study was to establish gestational age specific reference values for fetal TVI measurements and to introduce the CSD as a potential aid in fetal myocardial evaluation. TVI recordings from 125 healthy fetuses, at 18 to 42 weeks of gestation, were performed with the transducer perpendicular to the apex to provide a four-chamber view. The myocardial velocity data was extracted from the basal segment of septum as well as the left and right ventricular free wall for subsequent offline analysis. During a cardiac cycle the longitudinal peak velocities of septum increased with gestational age, as did the peak velocities of the left and right ventricular free wall, except for the peak velocity of post ejection. The duration of rapid filling and atrial contraction increased during pregnancy while the duration of post ejection decreased. The duration of pre ejection and ventricular ejection did not change significantly with gestational age. Evaluating fetal systolic and diastolic performance using TVI together with CSD could contribute to increase the knowledge and understanding of fetal myocardial function and dysfunction. The pre and post ejection phases are the variables most likely to indicate fetuses with abnormal myocardial function.


  • Open Access

    Reproducibility and variability in the assessment of color-coded tissue velocity imaging of the fetal myocardium¬

    by Nina Elmstedt, Britta Lind, Kjerstin Ferm-Widlund, Magnus Westgren, Lars-Åke Brodin

    Objective: The introduction of color-coded tissue velocity imaging (TVI) in fetal medicine is quite recent, and as this method is presently evaluated and developed in regard to diagnostic precision it is of outmost importance to evaluate the reproducibility for adequate clinical use. In this study, reproducibility and intra- and inter-observer variability was assessed for offline analysis as well as echocardiography investigations. Also, we evaluated the importance of exact placement of the region of interest (ROI). Methods: TVI recordings from 21 fetuses, at a gestational age of 27 to 41 weeks, were acquired at 208-239 frames/s for subsequent offline analysis. All recordings were performed with the transducer positioned to provide an apical four-chamber view and the myocardial velocity data was obtained from basal inferoseptum. The data set was analyzed according to Bland-Altman and reproducibility was expressed as the standard error of a single determination, estimated from duplicate determinations in percentage of the total. Results: The variation of reproducibility for the echocardiography investigation ranged from 2.0% to 9.8%. The duration of left ventricular ejection, and the peak velocities of early diastolic filling and atrial contraction being the most robust events measured. The variation of inter-observer variability for the echocardiography investigation ranged from 1.5% to 8.4%, and the variation of intra- and inter-observer variability for the offline analysis ranged from 1.2% to 10.4%. Least robust were the events of shortest duration, including isovolumetric contraction and relaxation. Conclusion: We believe that TVI measurements of the fetal myocardium could be performed in the clinical routine with acceptable reproducibility.


  • Open Access

    OC18.02: The cardiac state diagram as a novel approach for evaluation of re‐ and post ejection phases of the cardiac cycle in asphyxiated fetal lambs

    by E. Wågström, J. Johnson, K. Ferm‐Widlund, N. Elmstedt, K. Liuba, B. Lind, L. Brodin, M. Westgren

  • Open Access

    Fetal cardiac muscle contractility decreases with gestational age: a color-coded tissue velocity imaging study

    by Nina Elmstedt, Kjerstin Ferm-Widlund, Britta Lind, Lars-Åke Brodin, Magnus Westgren

    Present data regarding how the fetal heart works and develops throughout gestation is limited. However, the possibility to analyze the myocardial velocity profile provides new possibilities to gain further knowledge in this area. Thus, the objective of this study was to evaluate human fetal myocardial characteristics and deformation properties using color-coded tissue velocity imaging (TVI).


  • Open Access

    Temporal frequency requirements for tissue velocity imaging of the fetal heart

    by N. Elmstedt, B. Lind, K. Ferm‐Widlund, M. Westgren, L. Å. Brodin

    Objectives: The high velocity and short duration of myocardial motion requires a high sampling rate to obtain adequate temporal resolution; this issue becomes even more important when taking into consideration the high fetal heart rate. In this study we have established optimal sampling requirements for assessing the duration of various cardiac cycle events and myocardial velocities of the fetal heart using color‐coded tissue velocity imaging (TVI).Methods: Recordings from 30 fetuses were acquired at an initial frame rate of 180–273 frames/s. All TVI recordings were performed from an apical four‐chamber view and stored as cineloops of five to 10 consecutive cardiac cycles for subsequent offline analysis using software enabling a reduction in frame rate. Different components of the myocardial velocity curve, obtained from the basal part of the ventricular septum, were measured at the initial frame rate and compared with their equivalents at gradually decreased frame rates.Results: As acquisition frame rate was reduced, there was a marked increase in deviation from the initial values, resulting in an underestimation of all systolic and diastolic velocities. For the measured durations, there was a clear tendency to underestimate isovolumetric contraction and relaxation, and a clear tendency to overestimate ventricular ejection and diastolic E‐wave and A‐wave. An acceptable ⩽ 5% deviation from the value obtained at the highest frame rate corresponded to measurements obtained at above 150–200 frames/s.Conclusions: A high sampling rate of at least 200 frames/s is necessary for adequate reconstruction of TVI data for the fetal heart. Frame rates that are too low result in considerable loss of temporal and velocity information. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.