Marie Moonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marie Moonen has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Patrizio Lancellotti
GIGA Cardiovascular Sciences, Heart Valve Clinic, University of Liège Hospital , Liège
5 shared publications - Bernard Cosyns
Cardiology Department, Centrum voor hart en vaatziekten, Universitair Ziekenhuis Brussel, Free University of Brussels , Brussels 1090
2 shared publications - Luc. A. Pierard
University of Liège
2 shared publications - Bernard Lambermont
GIGA Cardiovascular Science, University of Liege, Liege, Belgium
1 shared publication - Cécile Oury
GIGA Metabolism & Cardiovascular Biology – Laboratory of Cardiology University of Liège Avenue de l'Hôpital 11, Quartier Hôpital, Building B34 Liège 4000 Belgium
1 shared publication - David Haberman
CHU Tivoli, Cardiology department, Free University of Brussels, Belgium
1 shared publication
Latest Publications
- Open Access
- 8 August 2017
- Published by Springer Nature in Current Oncology Reports
- Vol. 19 (10) , 63
Cardiac Imaging: Multimodality Advances and Surveillance Strategies in Detection of Cardiotoxicity
- 8 August 2017
- Published by Springer Nature in Current Oncology Reports
- Vol. 19 (10) , 63
Open AccessCardiac Imaging: Multimodality Advances and Surveillance Strategies in Detection of Cardiotoxicity
- Open Access
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 86
Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency
Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves.
- 1 January 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 86
Open AccessMathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency
Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves.
- Open Access
- 16 June 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 27
Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function
In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 ± 65 mL and was underestimated by triplane contrast RT3DE (128 ± 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 ± 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 ± 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 ± 15%) and full-volume contrast RT3DE (45 ± 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease.
- 16 June 2009
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 7 (1) , 27
Open AccessComparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function
In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 ± 65 mL and was underestimated by triplane contrast RT3DE (128 ± 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 ± 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 ± 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 ± 15%) and full-volume contrast RT3DE (45 ± 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease.
- Open Access
- 31 December 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 65
Impact of contractile reserve on acute response to cardiac resynchronization therapy
Background: Cardiac resynchronization therapy (CRT) provides benefit for congestive heart failure, but still 30% of patients failed to respond to such therapy. This lack of response may be due to the presence of significant amount of scar or fibrotic tissue at myocardial level. This study sought to investigate the potential impact of myocardial contractile reserve as assessed during exercise echocardiography on acute response following CRT implantation. Methods: Fifty-one consecutive patients with heart failure (LV ejection fraction 27% ± 5%, 67% ischemic cardiomyopathy) underwent exercise Doppler echocardiography before CRT implantation to assess global contractile reserve (improvement in LV ejection fraction) and local contractile reserve in the region of the LV pacing lead (assessed by radial strain using speckle tracking analysis). Responders were defined by an increase in stroke volume ≥ 15% after CRT. Results: Compared with nonresponders, responders (25 patients) showed a greater exercise-induced increase in LV ejection fraction, a higher degree of mitral regurgitation and a significant extent of LV dyssynchrony. The presence of contractile reserve was directly related to the acute increase in stroke volume (r = 0.48, p < 0.001). Baseline myocardial deformation as well as contractile reserve in the LV pacing lead region was greater in responders during exercise than in nonresponders (p < 0.0001). Conclusion: The present study showed that response to CRT largely depends not only on the extent of LV dyssynchrony and the severity of mitral regurgitation but also on the presence of contractile reserve.
- 31 December 2008
- Published by Springer Nature in Cardiovascular Ultrasound
- Vol. 6 (1) , 65
Open AccessImpact of contractile reserve on acute response to cardiac resynchronization therapy
Background: Cardiac resynchronization therapy (CRT) provides benefit for congestive heart failure, but still 30% of patients failed to respond to such therapy. This lack of response may be due to the presence of significant amount of scar or fibrotic tissue at myocardial level. This study sought to investigate the potential impact of myocardial contractile reserve as assessed during exercise echocardiography on acute response following CRT implantation. Methods: Fifty-one consecutive patients with heart failure (LV ejection fraction 27% ± 5%, 67% ischemic cardiomyopathy) underwent exercise Doppler echocardiography before CRT implantation to assess global contractile reserve (improvement in LV ejection fraction) and local contractile reserve in the region of the LV pacing lead (assessed by radial strain using speckle tracking analysis). Responders were defined by an increase in stroke volume ≥ 15% after CRT. Results: Compared with nonresponders, responders (25 patients) showed a greater exercise-induced increase in LV ejection fraction, a higher degree of mitral regurgitation and a significant extent of LV dyssynchrony. The presence of contractile reserve was directly related to the acute increase in stroke volume (r = 0.48, p < 0.001). Baseline myocardial deformation as well as contractile reserve in the LV pacing lead region was greater in responders during exercise than in nonresponders (p < 0.0001). Conclusion: The present study showed that response to CRT largely depends not only on the extent of LV dyssynchrony and the severity of mitral regurgitation but also on the presence of contractile reserve.
- Open Access
- 1 December 2008
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 34 (6) , 1265-1267
The blue man: an unusual happy end of a spontaneous rupture of a coronary artery
We report the case of spontaneous rupture of a coronary artery. It was that of a 56-year-old man admitted for dyspnoea and anterior thoracic pain. The most striking feature on physical examination was the marked cyanosis of his face, upper part of the thorax and the upper limb. The patient was haemodynamically unstable with tachycardia and hypotension. Cardiac tamponade was confirmed by echocardiography and computed tomography of the thorax. The patient was transferred for surgery. Emergency sternotomy revealed pericardial bloody effusion and a continuous bleeding around the posterior interventricular artery. No other perioperative findings could explain the haemopericardium. Haemostasis was obtained by a suture of the bleeding coronary artery.
- 1 December 2008
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 34 (6) , 1265-1267
Open AccessThe blue man: an unusual happy end of a spontaneous rupture of a coronary artery
We report the case of spontaneous rupture of a coronary artery. It was that of a 56-year-old man admitted for dyspnoea and anterior thoracic pain. The most striking feature on physical examination was the marked cyanosis of his face, upper part of the thorax and the upper limb. The patient was haemodynamically unstable with tachycardia and hypotension. Cardiac tamponade was confirmed by echocardiography and computed tomography of the thorax. The patient was transferred for surgery. Emergency sternotomy revealed pericardial bloody effusion and a continuous bleeding around the posterior interventricular artery. No other perioperative findings could explain the haemopericardium. Haemostasis was obtained by a suture of the bleeding coronary artery.