EMEdward W MartinJr

Edward W MartinJr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Edward W MartinJr has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    IR Spectroscopy and Linear Support Vector Machine Analysis of Colorectal Liver Metastasis

    by James V. Coe, Heather C. Allen, Samantha A. Skarda, Trina D. Orr, Antrae L. Wilson Ii, Destiny G. Wilson, Susan Kalliantas, Steven V. Nystrom, Rebecca C. Bradley, Ran Li, et al.

    The Colorectal Liver Metastasis (CLM) library contains 756,096 full range Fourier transform infrared (FTIR) microscope imaging spectra of 14 frozen tissue sections from 7 different consenting patients with liver metastasis of colorectal origin. A subset of 30 windows was defined in predominant tumor or nontumor regions for the training or testing of linear support vector machine (SVM) models. Since the number of consenting patients was small, the primary purpose of this work was to establish a physical chemistry perspective on the infrared (IR) spectroscopy of metastatic liver cancer using the large number of available spectra. The linear SVM model was trained with a Leave-One-Case-Out strategy to avoid case leakage, minimize overtraining, and offer simple feature selection. The primary result is the derivation and measurement of a spectral form for the average contribution to the tumor/nontumor decision at each spectral step, i.e., the "Decision Contribution Spectrum". Finally, the results are used toward the design of a fast mid-IR cancer probe for the operating room giving quick tumor decisions despite a reduced range of wavenumbers and an increased interval between wavenumber steps as compared to the FTIR input spectral data.


  • Antigen-Directed Cancer Surgery for Primary Colorectal Cancer: 15-Year Survival Analysis: A Reply

    by Stephen P. Povoski, Ioannis S. Hatzaras, Cathy M. Mojzisik, Mark W. Arnold, Charles L. Hitchcock, Edward W. Martin

  • Open Access

    Feasibility of a multimodal 18F-FDG-directed lymph node surgical excisional biopsy approach for appropriate diagnostic tissue sampling in patients with suspected lymphoma

    by Stephen P Povoski, Nathan C Hall, Douglas A Murrey, Chadwick L Wright, Edward W Martin

    18F-FDG PET/CT imaging is widely utilized in the clinical evaluation of patients with suspected or documented lymphoma. The aim was to describe our cumulative experience with a multimodal 18F-FDG-directed lymph node surgical excisional biopsy approach in patients with suspected lymphoma. Thirteen patients (mean age 51 (±16;22–76) years), with suspected new or suspected recurrent lymphoma suggested by 18F-FDG-avid lesions seen on prior diagnostic whole-body PET/CT imaging, were injected IV with 18F-FDG prior to undergoing same-day diagnostic lymph node surgical excisional biopsy in the operating room. Various 18F-FDG detection strategies were used on the day of surgery, including, (1) same-day pre-resection patient PET/CT; (2) intraoperative gamma probe assessment; (3) clinical scanner specimen PET/CT imaging of whole surgically excised tissue specimens; (4) specimen gamma well counts; and/or (5) same-day post-resection patient PET/CT. Same-day 18F-FDG injection dose was 14.8 (±2.4;12.5-20.6) millicuries or 548 (±89;463–762) megabecquerels. Sites of 18F-FDG-avid lesions were 4 inguinal, 3 cervical, 3 abdominal/retroperitoneal, 2 axillary, and 1 gluteal region subcutaneous tissue. Same-day pre-resection patient PET/CT was performed on 6 patients. Intraoperative gamma probe assessment was performed on 13 patients. Clinical scanner PET/CT imaging of whole surgically excised tissue specimens was performed in 10 cases. Specimen gamma well counts were performed in 6 cases. Same-day post-resection patient PET/CT imaging was performed on 8 patients. Time from 18F-FDG injection to same-day pre-resection patient PET/CT, intraoperative gamma probe assessment, and same-day post-resection patient PET/CT were 76 (±8;64–84), 240 (±63;168–304), and 487 (±104;331–599) minutes, respectively. Time from 18F-FDG injection to clinical scanner PET/CT of whole surgically excised tissue specimens was 363 (±60;272–446) minutes. Time from 18F-FDG injection to specimen gamma well counts was 591 (±96;420–689) minutes. Intraoperative gamma probe assessment successfully identified 18F-FDG-avid lesions in 12/13 patients. Histopathologic evaluation confirmed lymphoma in 12/13 patients and benign disease in 1/13 patients. A multimodal approach to 18F-FDG-directed lymph node surgical excisional biopsy for suspected lymphoma is technically feasible for guiding appropriate diagnostic tissue sampling of lymph nodes seen as 18F-FDG-avid lesions on diagnostic 18F-FDG PET/CT imaging.


  • Open Access

    Comparison of two threshold detection criteria methodologies for determination of probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery

    by Gregg J Chapman, Stephen P Povoski, Nathan C Hall, Douglas A MurreyJr, Robert Lee, Edward W Martin Jr

    Intraoperative in situ identification of 18F-FDG-avid tissue sites during radioguided oncologic surgery remains a significant challenge for surgeons. The purpose of our study was to evaluate the 1.5-to-1 ratiometric threshold criteria method versus the three-sigma statistical threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites in a manner that was independent of the specific type of gamma detection probe used. From among 52 patients undergoing appropriate in situ evaluation of presumed abnormal 18F-FDG-avid tissue sites during 18F-FDG-directed surgery using 6 available gamma detection probe systems, a total of 401 intraoperative gamma detection probe measurement sets of in situ counts per second measurements were cumulatively taken. For the 401 intraoperative gamma detection probe measurement sets, probe positivity was successfully met by the 1.5-to-1 ratiometric threshold criteria method in 150/401 instances (37.4%) and by the three-sigma statistical threshold criteria method in 259/401 instances (64.6%) (P < 0.001). Likewise, the three-sigma statistical threshold criteria method detected true positive results at target-to-background ratios much lower than the 1.5-to-1 target-to-background ratio of the 1.5-to-1 ratiometric threshold criteria method. The three-sigma statistical threshold criteria method was significantly better than the 1.5-to-1 ratiometric threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ detection of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery. This finding may be extremely important for reshaping the ongoing and future research and development of gamma detection probe systems that are necessary for optimizing the in situ detection of radioisotopes of higher-energy gamma photon emissions used during radioguided oncologic surgery.


  • Open Access

    18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals derived from a single-institution 18F-FDG-directed surgery experience: feasibility and quantification of 18F-FDG accumulation within 18F-FDG-avid lesions and background tissues

    by Stephen P Povoski, Douglas A Murrey, Sabrina M Smith, Edward W Martin, Nathan C Hall

    18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is a well-established imaging modality for a wide variety of solid malignancies. Currently, only limited data exists regarding the utility of PET/CT imaging at very extended injection-to-scan acquisition times. The current retrospective data analysis assessed the feasibility and quantification of diagnostic 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals.


  • Open Access

    Intraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria

    by Stephen P Povoski, Gregg J Chapman, Douglas A Murrey, Robert Lee, Edward W Martin, Nathan C Hall

    Intraoperative detection of 18F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems.


  • Use of intraoperative nuclear medicine imaging technology: strategy for improved patient management

    by Nathan C Hall, Stephen P Povoski, Jun Zhang, Michael V Knopp, Edward W Martin


  • Open Access

    Retrospective review of pelvic malignancies undergoing total pelvic exenteration

    by Maureen P Kuhrt, Ravi J Chokshi, David Arrese, Edward W Martin Jr

    In patients with locally advanced or recurrent pelvic malignancies, total pelvic exenteration (TPE) may be necessary for curative treatment. Despite improvements in mortality rates since TPE was first described, morbidity rates remain high due to the extensive resection and the aggressiveness of these tumors. We have studied the outcomes of TPE surgery performed at our institution.


  • Open Access

    Cytopathologic evaluation of the in situ margin in patients undergoing hepatectomy

    by Natalie B. Jones, Paul E. Wakely, Dori L. Klemanski, Osama Al‐Saif, Gregory Young, Wendy L. Frankel, Edward W. Martin, Mark Bloomston

    BACKGROUND: Margin status is a predictor of outcome for patients with liver malignancies, although what constitutes a negative margin is controversial. Traditionally, the completeness of resection is estimated by surgical histopathology of the resected specimen margin, despite the in situ margin being potentially more important. The true margin is often altered by parenchymal transection techniques. The authors propose that cytologic assessment of the in situ margin is more specific for determining the true margin. METHODS: A total of 84 patients with primary or metastatic liver tumors who were undergoing surgical resection were enrolled in this prospective Institutional Review Board‐approved study. Specimen and in situ (patient) margins were assessed using a “scrape preparation” cytologic technique and compared with traditional surgical histopathology. Patients were followed for assessment of local disease recurrence. RESULTS: Follow‐up data were complete for 64 patients for a median of 37 months (range, 12 months‐56 months). Twenty patients were excluded because of perioperative death (6 patients; 7%) or a follow‐up of < 12 months. Seven patients (12.2%) had positive histopathologic specimen margins, but only 1 was found to be positive by cytology (1.8%). No in situ cytologically positive margins were identified along the cut edge of the liver remnant. The rate of intra‐ or extrahepatic recurrences was 56.7%, whereas the local recurrence rate was 1.8%. One patient with local recurrence demonstrated simultaneous intra‐ and extrahepatic disease recurrences and had negative margins by all methods of evaluation. CONCLUSIONS: To the authors' knowledge, the current study is the first to demonstrate that in situ margins can be assessed using cytopathology. This method is quick and can be universally applied. Given the difficulty of accurately assessing margins after hepatectomy, cytopathologic evaluation may be more reflective of the true margin. Cancer (Cancer Cytopathol) 2012. © 2012 American Cancer Society.


  • Open Access

    Multimodal imaging and detection approach to 18F-FDG-directed surgery for patients with known or suspected malignancies: a comprehensive description of the specific methodology utilized in a single-institution cumulative retrospective experience

    by Stephen P Povoski, Nathan C Hall, Douglas A Murrey, Andrew Z Chow, Jay R Gaglani, Eamonn E Bahnson, Cathy M Mojzisik, Maureen P Kuhrt, Charles L Hitchcock, Michael V Knopp, et al.

    18F-FDG PET/CT is widely utilized in the management of cancer patients. The aim of this paper was to comprehensively describe the specific methodology utilized in our single-institution cumulative retrospective experience with a multimodal imaging and detection approach to 18F-FDG-directed surgery for known/suspected malignancies.