Steen Fjord Pedersen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steen Fjord Pedersen has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Won Yong Kim
Department of Cardiology, Aarhus University Hospital , Palle Juul-Jensens Boulevard 99, 8200 Aarhus N
6 shared publications - Samuel A. Thrysøe
MR-center, Aarhus University Hospital Skejby, Brendstrupsgaardsvej 100, Aarhus N DK-8200, Denmark
3 shared publications - Steffen Ringgaard
The MR Research Center, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
3 shared publications - William P. Paaske
Department Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark
3 shared publications - Erling Falk
From the Department of Clinical Medicine (J.F.B., E.F.), Aarhus University, and Department of Cardiology (J.F.B., E.F.), Aarhus University Hospital, Aarhus, Denmark; and CVPath Institute Inc, Gaithersburg, MD (F.O., R.V.).
2 shared publications - Esben Søvsø Szocska Hansen
The MR Research Centre, Department of Clinical Medicine Aarhus University Aarhus Denmark
2 shared publications
Latest Publications
- Open Access
- 1 September 2019
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 5 (3) , 298-301
Perigraft seroma penetrating the aortic sac and rupturing into the intraperitoneal cavity
- 1 September 2019
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 5 (3) , 298-301
Open AccessPerigraft seroma penetrating the aortic sac and rupturing into the intraperitoneal cavity
- Open Access
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 22
Imaging of carotid artery vessel wall edema using T2-weighted cardiovascular magnetic resonance
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 22
Open AccessImaging of carotid artery vessel wall edema using T2-weighted cardiovascular magnetic resonance
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 64-59
Assessment of intramyocardial hemorrhage by T1-weighted cardiovascular magnetic resonance in reperfused acute myocardial infarction
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 64-59
Open AccessAssessment of intramyocardial hemorrhage by T1-weighted cardiovascular magnetic resonance in reperfused acute myocardial infarction
- 27 December 2011
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28 (7) , 1717-1724
Determination of acute vascular injury and edema in porcine carotid arteries by T2 weighted cardiovascular magnetic resonance
Inflammation plays an essential role for destabilization and rupture of carotid atherosclerotic plaques causing embolic ischemic stroke. Inflammation of the vessel wall may result in the formation of edema. This study investigated whether edema in the carotid artery wall induced by acute balloon injury could be detected by cardiovascular magnetic resonance (CMR) using a T2-weighted short-tau inversion recovery sequence (T2-STIR). Edema was induced unilaterally by balloon injury in the carotid artery of six pigs. Four to nine days (average six) post injury, the carotid arteries were assessed by T2-STIR and multi-contrast weighted sequences. CMR images were matched to histopathology, validated against Evans blue, and correlated with the amount of fibrinogen in the arterial wall used as an edema marker. T2-STIR images showed that the carotid signal intensity (SI) divided by the sternocleid muscle SI of the injured carotid artery was on average 223% (P = 0.03) higher than that of the uninjured carotid artery. Using a threshold value of 4SD, T2-STIR detected edema in the vessel wall (i.e., hyperintense signal intensity) with a sensitivity of 100% and a specificity of 75%. Agreement was observed between carotid artery wall hyperintense signal intensity and Evans blue uptake (X 2 = 17.1, P < 0.001). The relative signal intensity correlated in a linear fashion with the amount of fibrinogen detected by histopathology (ρ = 0.9, P < 0.001). None of the multi-contrast weighted sequences detected edema in the carotid artery with reasonable sensitivity or specificity. T2-STIR CMR allowed carotid artery wall edema detection and may therefore be a useful non-invasive diagnostic tool for determination of inflammatory activity in the carotid artery wall.
- 27 December 2011
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 28 (7) , 1717-1724
Determination of acute vascular injury and edema in porcine carotid arteries by T2 weighted cardiovascular magnetic resonance
Inflammation plays an essential role for destabilization and rupture of carotid atherosclerotic plaques causing embolic ischemic stroke. Inflammation of the vessel wall may result in the formation of edema. This study investigated whether edema in the carotid artery wall induced by acute balloon injury could be detected by cardiovascular magnetic resonance (CMR) using a T2-weighted short-tau inversion recovery sequence (T2-STIR). Edema was induced unilaterally by balloon injury in the carotid artery of six pigs. Four to nine days (average six) post injury, the carotid arteries were assessed by T2-STIR and multi-contrast weighted sequences. CMR images were matched to histopathology, validated against Evans blue, and correlated with the amount of fibrinogen in the arterial wall used as an edema marker. T2-STIR images showed that the carotid signal intensity (SI) divided by the sternocleid muscle SI of the injured carotid artery was on average 223% (P = 0.03) higher than that of the uninjured carotid artery. Using a threshold value of 4SD, T2-STIR detected edema in the vessel wall (i.e., hyperintense signal intensity) with a sensitivity of 100% and a specificity of 75%. Agreement was observed between carotid artery wall hyperintense signal intensity and Evans blue uptake (X 2 = 17.1, P < 0.001). The relative signal intensity correlated in a linear fashion with the amount of fibrinogen detected by histopathology (ρ = 0.9, P < 0.001). None of the multi-contrast weighted sequences detected edema in the carotid artery with reasonable sensitivity or specificity. T2-STIR CMR allowed carotid artery wall edema detection and may therefore be a useful non-invasive diagnostic tool for determination of inflammatory activity in the carotid artery wall.
- Open Access
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 52
Determination of Edema in Porcine Coronary Arteries by T2 Weighted Cardiovascular Magnetic Resonance
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 52
Open AccessDetermination of Edema in Porcine Coronary Arteries by T2 Weighted Cardiovascular Magnetic Resonance
- Open Access
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 10
CMR Assessment of endothelial damage and angiogenesis in porcine coronary arteries using gadofosveset
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 10
Open AccessCMR Assessment of endothelial damage and angiogenesis in porcine coronary arteries using gadofosveset
- Open Access
- 12 March 2010
- Published by Springer Nature in BMC Physiology
- Vol. 10 (1) , 3
High-resolution ex vivo magnetic resonance angiography: a feasibility study on biological and medical tissues
Background: In biomedical sciences, ex vivo angiography is a practical mean to elucidate vascular structures three-dimensionally with simultaneous estimation of intravascular volume. The objectives of this study were to develop a magnetic resonance (MR) method for ex vivo angiography and to compare the findings with computed tomography (CT). To demonstrate the usefulness of this method, examples are provided from four different tissues and species: the human placenta, a rice field eel, a porcine heart and a turtle. Results: The optimal solution for ex vivo MR angiography (MRA) was a compound containing gelatine (0.05 g/mL), the CT contrast agent barium sulphate (0.43 mol/L) and the MR contrast agent gadoteric acid (2.5 mmol/L). It was possible to perform angiography on all specimens. We found that ex vivo MRA could only be performed on fresh tissue because formalin fixation makes the blood vessels permeable to the MR contrast agent. Conclusions: Ex vivo MRA provides high-resolution images of fresh tissue and delineates fine structures that we were unable to visualise by CT. We found that MRA provided detailed information similar to or better than conventional CTA in its ability to visualize vessel configuration while avoiding interfering signals from adjacent bones. Interestingly, we found that vascular tissue becomes leaky when formalin-fixed, leading to increased permeability and extravascular leakage of MR contrast agent.
- 12 March 2010
- Published by Springer Nature in BMC Physiology
- Vol. 10 (1) , 3
Open AccessHigh-resolution ex vivo magnetic resonance angiography: a feasibility study on biological and medical tissues
Background: In biomedical sciences, ex vivo angiography is a practical mean to elucidate vascular structures three-dimensionally with simultaneous estimation of intravascular volume. The objectives of this study were to develop a magnetic resonance (MR) method for ex vivo angiography and to compare the findings with computed tomography (CT). To demonstrate the usefulness of this method, examples are provided from four different tissues and species: the human placenta, a rice field eel, a porcine heart and a turtle. Results: The optimal solution for ex vivo MR angiography (MRA) was a compound containing gelatine (0.05 g/mL), the CT contrast agent barium sulphate (0.43 mol/L) and the MR contrast agent gadoteric acid (2.5 mmol/L). It was possible to perform angiography on all specimens. We found that ex vivo MRA could only be performed on fresh tissue because formalin fixation makes the blood vessels permeable to the MR contrast agent. Conclusions: Ex vivo MRA provides high-resolution images of fresh tissue and delineates fine structures that we were unable to visualise by CT. We found that MRA provided detailed information similar to or better than conventional CTA in its ability to visualize vessel configuration while avoiding interfering signals from adjacent bones. Interestingly, we found that vascular tissue becomes leaky when formalin-fixed, leading to increased permeability and extravascular leakage of MR contrast agent.
- 19 January 2004
- Vol. 166 (4) , 261-4
[MR imaging in the assessment of the extent of myocardial infarction].
- 19 January 2004
- Vol. 166 (4) , 261-4
[MR imaging in the assessment of the extent of myocardial infarction].