Yong S. Chu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yong S. Chu has a total of 213 co-authors. Here are the top co-authors by number of shared publications:
- Hanfei Yan
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, USA
17 shared publications - Xiaojing Huang
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, USA
15 shared publications - Evgeny Nazaretski
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
13 shared publications - Ajith Pattammattel
Brookhaven National Laboratory
7 shared publications - Nathalie Bouet
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
7 shared publications - Weihe Xu
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
5 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (6) , 1794-1800
A user-friendly platform for deep-learning-based image enhancement in scanning X-ray microscopy
Images acquired by scanning X-ray microscopy are often limited in spatial resolution by the finite size and profile of the scanning probe. Here, we present a dedicated graphical user interface for physics-informed image enhancement that incorporates the experimentally characterized probe to decouple probe-induced blurring from the measured images. The software integrates experimentally reconstructed probe intensity into the model training and provides an end-to-end workflow for image super-resolution and deblurring. We demonstrate the approach using differential phase-contrast imaging, where the finite scanning probe limits the recovery of fine spatial features. The enhanced images recover spatial details beyond those directly resolved in the measured data. This platform provides a practical and reproducible tool for physics-informed image enhancement during synchrotron X-ray microscopy experiments.
- 29 October 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (6) , 1794-1800
Open AccessA user-friendly platform for deep-learning-based image enhancement in scanning X-ray microscopy
Images acquired by scanning X-ray microscopy are often limited in spatial resolution by the finite size and profile of the scanning probe. Here, we present a dedicated graphical user interface for physics-informed image enhancement that incorporates the experimentally characterized probe to decouple probe-induced blurring from the measured images. The software integrates experimentally reconstructed probe intensity into the model training and provides an end-to-end workflow for image super-resolution and deblurring. We demonstrate the approach using differential phase-contrast imaging, where the finite scanning probe limits the recovery of fine spatial features. The enhanced images recover spatial details beyond those directly resolved in the measured data. This platform provides a practical and reproducible tool for physics-informed image enhancement during synchrotron X-ray microscopy experiments.
- Open Access
- 13 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (15)
Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography
We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.
- 13 April 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (15)
Open AccessAdvanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography
We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.
- Open Access
- 2 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 585-595
Development of electron source feedback for enhanced X-ray beam stability at NSLS-II
Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.
- 2 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 585-595
Open AccessDevelopment of electron source feedback for enhanced X-ray beam stability at NSLS-II
Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.
- Open Access
Limited-angle x-ray nano-tomography with machine-learning enabled iterative reconstruction engine
A long-standing challenge in tomography is the 'missing wedge' problem, which arises when the acquisition of projection images within a certain angular range is restricted due to geometrical constraints. This incomplete dataset results in significant artifacts and poor resolution in the reconstructed image. To tackle this challenge, we propose an approach dubbed Perception Fused Iterative Tomography Reconstruction Engine, which integrates a convolutional neural network (CNN) with perceptional knowledge as a smart regularizer into an iterative solving engine. We employ the Alternating Direction Method of Multipliers to optimize the solution in both physics and image domains, thereby achieving a physically coherent and visually enhanced result. We demonstrate the effectiveness of the proposed approach using various experimental datasets obtained with different x-ray microscopy techniques. All show significantly improved reconstruction even with a missing wedge of over 100 degrees - a scenario where conventional methods fail. Notably, it also improves the reconstruction in case of sparse projections, despite the network not being specifically trained for that. This demonstrates the robustness and generality of our method of addressing commonly occurring challenges in 3D x-ray imaging applications for real-world problems.
Open AccessLimited-angle x-ray nano-tomography with machine-learning enabled iterative reconstruction engine
A long-standing challenge in tomography is the 'missing wedge' problem, which arises when the acquisition of projection images within a certain angular range is restricted due to geometrical constraints. This incomplete dataset results in significant artifacts and poor resolution in the reconstructed image. To tackle this challenge, we propose an approach dubbed Perception Fused Iterative Tomography Reconstruction Engine, which integrates a convolutional neural network (CNN) with perceptional knowledge as a smart regularizer into an iterative solving engine. We employ the Alternating Direction Method of Multipliers to optimize the solution in both physics and image domains, thereby achieving a physically coherent and visually enhanced result. We demonstrate the effectiveness of the proposed approach using various experimental datasets obtained with different x-ray microscopy techniques. All show significantly improved reconstruction even with a missing wedge of over 100 degrees - a scenario where conventional methods fail. Notably, it also improves the reconstruction in case of sparse projections, despite the network not being specifically trained for that. This demonstrates the robustness and generality of our method of addressing commonly occurring challenges in 3D x-ray imaging applications for real-world problems.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
A versatile high-speed x-ray microscope for sub-10 nm imaging
We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
A versatile high-speed x-ray microscope for sub-10 nm imaging
We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.
- Open Access
- 16 February 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 16 (11) , 5760-5767
Enhanced magnetic susceptibility in Ti3C2Tx MXene with Co and Ni incorporation
We incorporate dilute concentrations of Ni and Co into Ti3C2Tx MXene, resulting in a >50 fold increase in magnetic susceptibility.
- 16 February 2024
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 16 (11) , 5760-5767
Open AccessEnhanced magnetic susceptibility in Ti3C2Tx MXene with Co and Ni incorporation
We incorporate dilute concentrations of Ni and Co into Ti3C2Tx MXene, resulting in a >50 fold increase in magnetic susceptibility.
- Open Access
- 1 December 2023
- Published by AIP Publishing in APL Machine Learning
- Vol. 1 (4)
Manifold projection image segmentation for nano-XANES imaging
As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nanoscale x-ray absorption near edge structure (XANES) imaging, where XANES spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used principal component analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as x-ray fluorescence data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including scanning transmission x-ray microscopy, where the length scale of domains is larger than the resolution of the experiment.
- 1 December 2023
- Published by AIP Publishing in APL Machine Learning
- Vol. 1 (4)
Open AccessManifold projection image segmentation for nano-XANES imaging
As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nanoscale x-ray absorption near edge structure (XANES) imaging, where XANES spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used principal component analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as x-ray fluorescence data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including scanning transmission x-ray microscopy, where the length scale of domains is larger than the resolution of the experiment.
- Open Access
- 17 August 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Accelerating Nano-XANES Imaging via Feature Selection
We investigate feature selection algorithms to reduce experimental time of nanoscale imaging via X-ray Absorption Fine Structure spectroscopy (nano-XANES imaging). Our approach is to decrease the required number of measurements in energy while retaining enough information to, for example, identify spatial domains and the corresponding crystallographic or chemical phase of each domain. We find sufficient accuracy in inferences when comparing predictions using the full energy point spectra to the reduced energy point subspectra recommended by feature selection. As a representative test case in the hard X-ray regime, we find that the total experimental time of nano-XANES imaging can be reduced by ~80% for a study of Fe-bearing mineral phases. These improvements capitalize on using the most common analysis procedure – linear combination fitting onto a reference library – to train the feature selection algorithm and thus learn the optimal measurements within this analysis context. We compare various feature selection algorithms such as Recursive Feature Elimination (RFE), random forest, and decision tree, and find that RFE produces moderately better recommendations. We further explore practices to maintain reliable feature selection results, especially when there is large uncertainty in the system, thus requiring a more expansive reference library, resulting in high linear mutual dependence within the reference set. More generally, the class of spectroscopic imaging experiments that scan energy by energy (rather than collecting an entire spectrum at once) is well-addressed by feature selection, and our approach is equally applicable to the soft X-ray regime via Scanning Transmission X-ray Microscopy (STXM) experiments.
- 17 August 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAccelerating Nano-XANES Imaging via Feature Selection
We investigate feature selection algorithms to reduce experimental time of nanoscale imaging via X-ray Absorption Fine Structure spectroscopy (nano-XANES imaging). Our approach is to decrease the required number of measurements in energy while retaining enough information to, for example, identify spatial domains and the corresponding crystallographic or chemical phase of each domain. We find sufficient accuracy in inferences when comparing predictions using the full energy point spectra to the reduced energy point subspectra recommended by feature selection. As a representative test case in the hard X-ray regime, we find that the total experimental time of nano-XANES imaging can be reduced by ~80% for a study of Fe-bearing mineral phases. These improvements capitalize on using the most common analysis procedure – linear combination fitting onto a reference library – to train the feature selection algorithm and thus learn the optimal measurements within this analysis context. We compare various feature selection algorithms such as Recursive Feature Elimination (RFE), random forest, and decision tree, and find that RFE produces moderately better recommendations. We further explore practices to maintain reliable feature selection results, especially when there is large uncertainty in the system, thus requiring a more expansive reference library, resulting in high linear mutual dependence within the reference set. More generally, the class of spectroscopic imaging experiments that scan energy by energy (rather than collecting an entire spectrum at once) is well-addressed by feature selection, and our approach is equally applicable to the soft X-ray regime via Scanning Transmission X-ray Microscopy (STXM) experiments.
- Open Access
- 18 July 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Manifold Projection Image Segmentation for Nano-XANES Imaging
As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nano-XANES imaging, where X-ray Absorption Near Edge Structure (XANES) spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used Principal Component Analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as X-ray Fluorescence (XRF) data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including Scanning Transmission X-ray Microscopy (STXM), where the length scale of domains is larger than the resolution of the experiment.
- 18 July 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessManifold Projection Image Segmentation for Nano-XANES Imaging
As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nano-XANES imaging, where X-ray Absorption Near Edge Structure (XANES) spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used Principal Component Analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as X-ray Fluorescence (XRF) data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including Scanning Transmission X-ray Microscopy (STXM), where the length scale of domains is larger than the resolution of the experiment.
- Open Access
- 4 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-8
Self-absorption correction on 2D X-ray fluorescence maps
X-ray fluorescence mapping (XRF) is a highly efficient and non-invasive technique for quantifying material composition with micro and nanoscale spatial resolutions. Quantitative XRF analysis, however, confronts challenges from the long-lasting problem called self-absorption. Moreover, correcting two-dimensional XRF mapping datasets is particularly difficult because it is an ill-posed inverse problem. Here we report a semi-empirical method that can effectively correct 2D XRF mapping data. The correction error is generally less than 10% from a comprehensive evaluation of the accuracy in various configurations. The proposed method was applied to quantify the composition distribution around the grain boundaries in an electrochemically corroded stainless steel sample. Highly localized Cr enrichment was found around the crack sites, which was invisible before the absorption correction.
- 4 May 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-8
Open AccessSelf-absorption correction on 2D X-ray fluorescence maps
X-ray fluorescence mapping (XRF) is a highly efficient and non-invasive technique for quantifying material composition with micro and nanoscale spatial resolutions. Quantitative XRF analysis, however, confronts challenges from the long-lasting problem called self-absorption. Moreover, correcting two-dimensional XRF mapping datasets is particularly difficult because it is an ill-posed inverse problem. Here we report a semi-empirical method that can effectively correct 2D XRF mapping data. The correction error is generally less than 10% from a comprehensive evaluation of the accuracy in various configurations. The proposed method was applied to quantify the composition distribution around the grain boundaries in an electrochemically corroded stainless steel sample. Highly localized Cr enrichment was found around the crack sites, which was invisible before the absorption correction.