Huan Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Huan Tan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Christopher B. Glielmi
MR Research and Development
1 shared publication Craig A. Hamilton
School of Biomedical Engineering and Sciences, Virginia‐Tech and Wake Forest University, Winston‐Salem, North Carolina, USA
1 shared publicationIoannis Koktzoglou
Department of Radiology Northshore University HealthSystem Evanston Illinois USA
1 shared publication- Ioannis Koktzoglou
Department of Radiology Endeavor Health Evanston Illinois USA
1 shared publication Jon Thacker
Department of Biomedical Engineering Northwestern University Evanston Illinois USA
1 shared publicationMatthias Günther
Mediri GmbH, Heidelberg, Germany
1 shared publication
Latest Publications
- Open Access
- 6 May 2014
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (4) , 1124-1128
Sensitivity of arterial spin labeling perfusion MRI to pharmacologically induced perfusion changes in rat kidneys
Purpose: To investigate whether arterial spin labeling (ASL) MRI is sensitive to changes by pharmacologically induced vasodilation and vasoconstriction in rat kidneys.Materials and Methods: Changes in renal cortical blood flow in seven rats were induced by adenosine infusion (vasodilation) and L‐NAME injection (vasoconstriction). All imaging studies were performed on a 3 Tesla scanner using a FAIR‐TrueFISP sequence for the ASL implementation. The acquisition time for each ASL scan was 6 min. Cortical perfusion rates were calculated using regions of interest analysis, and the differences in perfusion rates during baseline, vasodilation, and vasoconstriction were compared and assessed for statistical significance.Results: Compared with the baseline, an average of 94 mL/100 g/min increase and 157 mL/100 g/min decrease in cortical perfusion was observed following adenosine infusion and L‐NAME administration, respectively. The changes in cortical perfusion were significant between baseline and vasodilation (P < 0.05), baseline and vasoconstriction (P < 0.01), and vasodilation and vasoconstriction (P < 0.01).Conclusion: ASL is sensitive to pharmacologically induced perfusion changes in rat kidneys at doses comparable to current use. The preliminary results suggest the feasibility of ASL for investigating renal blood flow in a variety of rodent models.J. Magn. Reson. Imaging 2015;41:1124–1128. ©2014 Wiley Periodicals, Inc.
- 6 May 2014
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (4) , 1124-1128
Open AccessSensitivity of arterial spin labeling perfusion MRI to pharmacologically induced perfusion changes in rat kidneys
Purpose: To investigate whether arterial spin labeling (ASL) MRI is sensitive to changes by pharmacologically induced vasodilation and vasoconstriction in rat kidneys.Materials and Methods: Changes in renal cortical blood flow in seven rats were induced by adenosine infusion (vasodilation) and L‐NAME injection (vasoconstriction). All imaging studies were performed on a 3 Tesla scanner using a FAIR‐TrueFISP sequence for the ASL implementation. The acquisition time for each ASL scan was 6 min. Cortical perfusion rates were calculated using regions of interest analysis, and the differences in perfusion rates during baseline, vasodilation, and vasoconstriction were compared and assessed for statistical significance.Results: Compared with the baseline, an average of 94 mL/100 g/min increase and 157 mL/100 g/min decrease in cortical perfusion was observed following adenosine infusion and L‐NAME administration, respectively. The changes in cortical perfusion were significant between baseline and vasodilation (P < 0.05), baseline and vasoconstriction (P < 0.01), and vasodilation and vasoconstriction (P < 0.01).Conclusion: ASL is sensitive to pharmacologically induced perfusion changes in rat kidneys at doses comparable to current use. The preliminary results suggest the feasibility of ASL for investigating renal blood flow in a variety of rodent models.J. Magn. Reson. Imaging 2015;41:1124–1128. ©2014 Wiley Periodicals, Inc.
- Open Access
- 27 February 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (2) , 570-579
Renal perfusion imaging with two‐dimensional navigator gated arterial spin labeling
Purpose: To develop a navigator technique enabling free‐breathing acquisition to afford sufficient signal averaging for quantitative renal perfusion measurement using arterial spin labeling MRI.Methods: A novel two‐dimensional (2D) navigator technique was implemented in concert with flow‐sensitive alternating inversion recovery (FAIR) preparation and true fast imaging with steady precession (True‐FISP) readout. The navigator images were obtained with a low‐resolution fast low angle shot readout at end of each arterial spin labeling acquisition. A retrospective algorithm was developed to automatically detect respiratory motion for selective signal averaging. The 2D navigator‐gated FAIR True‐FISP sequence was performed in ten healthy volunteers and five patients with chronic kidney disease.Results: Excellent image quality and comparable cortical perfusion rates (healthy: 276 ± 28 mL/100 g/min, patients: 155 ± 25 mL/100 g/min) to literature values were obtained. An average of 3‐fold signal‐to‐noise ratio improvement was obtained in the 2D navigator‐gated approach compared with the breath‐hold acquisition in healthy volunteers. Good image quality was achieved in patients while the results from breath‐hold acquisition were unusable. The quantitative perfusion rates were significantly lower in chronic kidney disease patients compared with the healthy volunteers.Conclusion: 2D navigator‐gated free breathing arterial spin labeling is feasible and is a noninvasive method to evaluate renal perfusion both in healthy subjects and those with chronic kidney disease. Magn Reson Med 71:570–579, 2014.
- 27 February 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (2) , 570-579
Open AccessRenal perfusion imaging with two‐dimensional navigator gated arterial spin labeling
Purpose: To develop a navigator technique enabling free‐breathing acquisition to afford sufficient signal averaging for quantitative renal perfusion measurement using arterial spin labeling MRI.Methods: A novel two‐dimensional (2D) navigator technique was implemented in concert with flow‐sensitive alternating inversion recovery (FAIR) preparation and true fast imaging with steady precession (True‐FISP) readout. The navigator images were obtained with a low‐resolution fast low angle shot readout at end of each arterial spin labeling acquisition. A retrospective algorithm was developed to automatically detect respiratory motion for selective signal averaging. The 2D navigator‐gated FAIR True‐FISP sequence was performed in ten healthy volunteers and five patients with chronic kidney disease.Results: Excellent image quality and comparable cortical perfusion rates (healthy: 276 ± 28 mL/100 g/min, patients: 155 ± 25 mL/100 g/min) to literature values were obtained. An average of 3‐fold signal‐to‐noise ratio improvement was obtained in the 2D navigator‐gated approach compared with the breath‐hold acquisition in healthy volunteers. Good image quality was achieved in patients while the results from breath‐hold acquisition were unusable. The quantitative perfusion rates were significantly lower in chronic kidney disease patients compared with the healthy volunteers.Conclusion: 2D navigator‐gated free breathing arterial spin labeling is feasible and is a noninvasive method to evaluate renal perfusion both in healthy subjects and those with chronic kidney disease. Magn Reson Med 71:570–579, 2014.
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 47-30
Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 47-30
Open AccessOptimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries
- Open Access
- 19 January 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (1) , 168-173
3D GRASE PROPELLER: Improved image acquisition technique for arterial spin labeling perfusion imaging
Arterial spin labeling is a noninvasive technique that can quantitatively measure cerebral blood flow. While traditionally arterial spin labeling employs 2D echo planar imaging or spiral acquisition trajectories, single‐shot 3D gradient echo and spin echo (GRASE) is gaining popularity in arterial spin labeling due to inherent signal‐to‐noise ratio advantage and spatial coverage. However, a major limitation of 3D GRASE is through‐plane blurring caused by T2 decay. A novel technique combining 3D GRASE and a periodically rotated overlapping parallel lines with enhanced reconstruction trajectory (PROPELLER) is presented to minimize through‐plane blurring without sacrificing perfusion sensitivity or increasing total scan time. Full brain perfusion images were acquired at a 3 × 3 × 5 mm3 nominal voxel size with pulsed arterial spin labeling preparation sequence. Data from five healthy subjects was acquired on a GE 1.5T scanner in less than 4 minutes per subject. While showing good agreement in cerebral blood flow quantification with 3D gradient echo and spin echo, 3D GRASE PROPELLER demonstrated reduced through‐plane blurring, improved anatomical details, high repeatability and robustness against motion, making it suitable for routine clinical use. Magn Reson Med, 2011.
- 19 January 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (1) , 168-173
Open Access3D GRASE PROPELLER: Improved image acquisition technique for arterial spin labeling perfusion imaging
Arterial spin labeling is a noninvasive technique that can quantitatively measure cerebral blood flow. While traditionally arterial spin labeling employs 2D echo planar imaging or spiral acquisition trajectories, single‐shot 3D gradient echo and spin echo (GRASE) is gaining popularity in arterial spin labeling due to inherent signal‐to‐noise ratio advantage and spatial coverage. However, a major limitation of 3D GRASE is through‐plane blurring caused by T2 decay. A novel technique combining 3D GRASE and a periodically rotated overlapping parallel lines with enhanced reconstruction trajectory (PROPELLER) is presented to minimize through‐plane blurring without sacrificing perfusion sensitivity or increasing total scan time. Full brain perfusion images were acquired at a 3 × 3 × 5 mm3 nominal voxel size with pulsed arterial spin labeling preparation sequence. Data from five healthy subjects was acquired on a GE 1.5T scanner in less than 4 minutes per subject. While showing good agreement in cerebral blood flow quantification with 3D gradient echo and spin echo, 3D GRASE PROPELLER demonstrated reduced through‐plane blurring, improved anatomical details, high repeatability and robustness against motion, making it suitable for routine clinical use. Magn Reson Med, 2011.