Carsten Rickers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carsten Rickers has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Inga Voges
Department for Congenital Cardiology and Pediatric Cardiology, University Hospital Schleswig-Holstein, Campus Kiel, 24105 Kiel, Germany
9 shared publications Hans-Heiner Kramer
Department for Congenital Heart Disease and Paediatric Cardiology, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel, Germany
5 shared publicationsChristopher Hart
Department of Congenital Heart Disease and Pediatric Cardiology, University Hospital of Schleswig-Holstein, Kiel, Germany (I.V., P.W., C.H., D.G., A.A.B., G.F., A.C.A., H.M.P., I.K., H.H.K., C.R.).
4 shared publicationsJens Scheewe
Department of Cardiovascular Surgery, University Hospital of Schleswig-Holstein Campus Kiel, Kiel, Germany
4 shared publicationsEileen Pardun
Department of Congenital Heart Disease and Pediatric Cardiology , University Hospital of Schleswig-Holstein , Kiel , Germany
3 shared publicationsMichael Jerosch-Herold
Department of Radiology , Brigham and Women's Hospital & Harvard Medical School , Boston , MA, USA
3 shared publications
Latest Publications
- Open Access
- 26 May 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (6) , 1149-1154
Restrictive enlargement of the pulmonary annulus at repair of tetralogy of Fallot: a comparative 10-year follow-up study†
OBJECTIVES: Since 1996, our centre performs restrictive enlargement of the pulmonary annulus at surgical repair of tetralogy of Fallot. A transannular patch is only used if the z-score of the pulmonary annulus is smaller than −2. We sought to determine whether this strategy reduces pulmonary insufficiency (PI) and reoperation rate compared to a nationwide contemporary cohort that has not been operated using a uniform strategy. METHODS: Eighty-seven tetralogy of Fallot patients were included in the study (Group 1). One hundred sixty-seven tetralogy of Fallot patients from the Competence Network for Congenital Heart Disease served as controls (Group 2). Clinical, echocardiographic, electrocardiogram, cardiovascular magnetic resonance and outcome data were analysed. RESULTS: Follow-up time since repair was not different between groups [12.9 (7.8–18.8) vs 13.1 (5.2-16.9) years, P = 0.96] while transannular patch rate was significantly lower in Group 1 (32.2% vs 64.7%, P < 0.001). Ten-year freedom from reoperation for PI was significantly higher in our cohort (98% vs 92%, P = 0.01). Multivariable analysis identified restrictive enlargement as the only predictor for no need of reoperation [hazard ratio 0.4 (95% confidence interval 0.24–0.84), P < 0.01]. In Group 1, cardiovascular magnetic resonance-derived volumes were smaller (indexed end-diastolic volume: 103 ± 24 vs 123 ± 31 ml/m2, P < 0.001; indexed end-systolic volume: 53 ± 19 vs 59 ± 20 ml/m2, P = 0.04) and regurgitation fraction was lower (21 ± 14 vs 31 ± 17%, P < 0.001). CONCLUSIONS: Restrictive enlargement of the pulmonary annulus reduces PI and limits the amount of right ventricular dilatation at intermediate-term follow-up. The need for reoperation to alleviate PI is significantly lower compared to a contemporary cohort. Restrictive enlargement strategy has a stronger influence on freedom from reoperation than the use of a transannular patch. Clinical Trial Registration: WHO Main ID: DRKS00010087. URL: http://apps.who.int/trialsearch/Trial2.aspx?TrialID=DRKS00010087.
- 26 May 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (6) , 1149-1154
Open AccessRestrictive enlargement of the pulmonary annulus at repair of tetralogy of Fallot: a comparative 10-year follow-up study†
OBJECTIVES: Since 1996, our centre performs restrictive enlargement of the pulmonary annulus at surgical repair of tetralogy of Fallot. A transannular patch is only used if the z-score of the pulmonary annulus is smaller than −2. We sought to determine whether this strategy reduces pulmonary insufficiency (PI) and reoperation rate compared to a nationwide contemporary cohort that has not been operated using a uniform strategy. METHODS: Eighty-seven tetralogy of Fallot patients were included in the study (Group 1). One hundred sixty-seven tetralogy of Fallot patients from the Competence Network for Congenital Heart Disease served as controls (Group 2). Clinical, echocardiographic, electrocardiogram, cardiovascular magnetic resonance and outcome data were analysed. RESULTS: Follow-up time since repair was not different between groups [12.9 (7.8–18.8) vs 13.1 (5.2-16.9) years, P = 0.96] while transannular patch rate was significantly lower in Group 1 (32.2% vs 64.7%, P < 0.001). Ten-year freedom from reoperation for PI was significantly higher in our cohort (98% vs 92%, P = 0.01). Multivariable analysis identified restrictive enlargement as the only predictor for no need of reoperation [hazard ratio 0.4 (95% confidence interval 0.24–0.84), P < 0.01]. In Group 1, cardiovascular magnetic resonance-derived volumes were smaller (indexed end-diastolic volume: 103 ± 24 vs 123 ± 31 ml/m2, P < 0.001; indexed end-systolic volume: 53 ± 19 vs 59 ± 20 ml/m2, P = 0.04) and regurgitation fraction was lower (21 ± 14 vs 31 ± 17%, P < 0.001). CONCLUSIONS: Restrictive enlargement of the pulmonary annulus reduces PI and limits the amount of right ventricular dilatation at intermediate-term follow-up. The need for reoperation to alleviate PI is significantly lower compared to a contemporary cohort. Restrictive enlargement strategy has a stronger influence on freedom from reoperation than the use of a transannular patch. Clinical Trial Registration: WHO Main ID: DRKS00010087. URL: http://apps.who.int/trialsearch/Trial2.aspx?TrialID=DRKS00010087.
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 56-11
Aortic stiffening and its impact on left atrial volumes and function in patients after successful coarctation repair: a multiparametric cardiovascular magnetic resonance study
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 56-11
Open AccessAortic stiffening and its impact on left atrial volumes and function in patients after successful coarctation repair: a multiparametric cardiovascular magnetic resonance study
- Open Access
- 27 October 2015
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 4 (10) , e002107
Frequent Dilatation of the Descending Aorta in Children With Hypoplastic Left Heart Syndrome Relates to Decreased Aortic Arch Elasticity
Background: Patients with hypoplastic left heart syndrome after a Norwood operation show dilatation and reduced distensibility of the reconstructed proximal aorta. Cardiac magnetic resonance imaging ( CMR ) and angiographic examinations indicate that the native descending aorta ( DA o) is also dilated, but this has not been studied in detail. Methods and Results: Seventy‐nine children with hypoplastic left heart syndrome in Fontan circulation (aged 6.3±3.2 years) and 18 control participants (aged 6.8±2.4 years) underwent 3.0‐tesla CMR . Gradient‐echo cine and phase‐contrast imaging was applied to measure cross‐sectional areas ( CSA s), distensibility, pulse wave velocity, and the incremental elastic modulus of the thoracic aorta. CSA of the DA o in patients was also compared with published percentiles for aortic CSA . Patients had significantly larger CSA of the DA o at the level of pulmonary artery bifurcation (229.1±97.2 versus 175.7±24.3 mm/m 2 , P =0.04) and the diaphragm (196.2±66.0 versus 142.6±16.7 mm/m 2 , P 95th percentile level for control participants, and the incremental elastic modulus of the aortic arch and the DA o was higher than in patients with normal CSA s (arch: 90.1±64.3 versus 45.6±38.9 m/s; DA o: 86.3±53.7 versus 47.1±47.6 m/s; P r =0.5; DA o: r =0.49; P <0.01). Conclusions: Children with hypoplastic left heart syndrome frequently show dilatation of their DA o associated with increased stiffness of the aortic arch. Higher aortic impedance increases the afterload of the systemic circulation and likely contributes to the burden of the systemic right ventricle.
- 27 October 2015
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 4 (10) , e002107
Open AccessFrequent Dilatation of the Descending Aorta in Children With Hypoplastic Left Heart Syndrome Relates to Decreased Aortic Arch Elasticity
Background: Patients with hypoplastic left heart syndrome after a Norwood operation show dilatation and reduced distensibility of the reconstructed proximal aorta. Cardiac magnetic resonance imaging ( CMR ) and angiographic examinations indicate that the native descending aorta ( DA o) is also dilated, but this has not been studied in detail. Methods and Results: Seventy‐nine children with hypoplastic left heart syndrome in Fontan circulation (aged 6.3±3.2 years) and 18 control participants (aged 6.8±2.4 years) underwent 3.0‐tesla CMR . Gradient‐echo cine and phase‐contrast imaging was applied to measure cross‐sectional areas ( CSA s), distensibility, pulse wave velocity, and the incremental elastic modulus of the thoracic aorta. CSA of the DA o in patients was also compared with published percentiles for aortic CSA . Patients had significantly larger CSA of the DA o at the level of pulmonary artery bifurcation (229.1±97.2 versus 175.7±24.3 mm/m 2 , P =0.04) and the diaphragm (196.2±66.0 versus 142.6±16.7 mm/m 2 , P 95th percentile level for control participants, and the incremental elastic modulus of the aortic arch and the DA o was higher than in patients with normal CSA s (arch: 90.1±64.3 versus 45.6±38.9 m/s; DA o: 86.3±53.7 versus 47.1±47.6 m/s; P r =0.5; DA o: r =0.49; P <0.01). Conclusions: Children with hypoplastic left heart syndrome frequently show dilatation of their DA o associated with increased stiffness of the aortic arch. Higher aortic impedance increases the afterload of the systemic circulation and likely contributes to the burden of the systemic right ventricle.
- Open Access
- 30 June 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (4) , e272-e279
Adverse results of a decellularized tissue-engineered pulmonary valve in humans assessed with magnetic resonance imaging
Matrix P® and Matrix P plus® tissue-engineered pulmonary valves (TEPV) were offered as an improvement for pulmonary valve replacement (PVR) because of recellularization by host cells. The high frequency of graft failure gave reason to evaluate the underlying morphological substrate using magnetic resonance imaging (MRI) and histology. Between June 2006 and August 2008, 17 Matrix P® and 10 Matrix P plus® TEPVs were implanted in 26 patients with a median age of 12.4 (range: 0.8–38.7, interquartile range: 6.1–18.1) years. The grafts were studied by MRI, and underwent histological examination when explantation was required. Surgical (n = 13) or transcatheter (n = 1) TEPV replacement because of graft failure was needed in 14 cases (52%) 19 (0.5–53) months after implantation. MRI detected significant TEPV stenosis with mild insufficiency (Vmax = 3.7 ± (standard deviation) 0.5 m/s, regurgitant fraction (RGF) = 10 ± 3%) and stenosis with moderate-to-severe insufficiency (Vmax = 3.5 ± 0.8 m/s, RGF = 38 ± 10%) in 6 patients, respectively, and severe insufficiency (RGF = 40%) in 1 patient. In patients with graft failure, MRI showed hyperenhancement and TEPV wall thickening. Histology revealed severe inflammation, increased fibrous tissue and foreign-body reaction against valve leaflets and fascial tissue, while TEPV endothelialization was not detected in any case. The high frequency of Matrix P® and Matrix P plus® graft failure can be related to inflammation and fibrosis revealed by MRI and histology. Our results do not support the use of these valves for PVR and suggest careful follow-up examinations, including MRI for early detection of graft inflammation and fibrosis.
- 30 June 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (4) , e272-e279
Open AccessAdverse results of a decellularized tissue-engineered pulmonary valve in humans assessed with magnetic resonance imaging
Matrix P® and Matrix P plus® tissue-engineered pulmonary valves (TEPV) were offered as an improvement for pulmonary valve replacement (PVR) because of recellularization by host cells. The high frequency of graft failure gave reason to evaluate the underlying morphological substrate using magnetic resonance imaging (MRI) and histology. Between June 2006 and August 2008, 17 Matrix P® and 10 Matrix P plus® TEPVs were implanted in 26 patients with a median age of 12.4 (range: 0.8–38.7, interquartile range: 6.1–18.1) years. The grafts were studied by MRI, and underwent histological examination when explantation was required. Surgical (n = 13) or transcatheter (n = 1) TEPV replacement because of graft failure was needed in 14 cases (52%) 19 (0.5–53) months after implantation. MRI detected significant TEPV stenosis with mild insufficiency (Vmax = 3.7 ± (standard deviation) 0.5 m/s, regurgitant fraction (RGF) = 10 ± 3%) and stenosis with moderate-to-severe insufficiency (Vmax = 3.5 ± 0.8 m/s, RGF = 38 ± 10%) in 6 patients, respectively, and severe insufficiency (RGF = 40%) in 1 patient. In patients with graft failure, MRI showed hyperenhancement and TEPV wall thickening. Histology revealed severe inflammation, increased fibrous tissue and foreign-body reaction against valve leaflets and fascial tissue, while TEPV endothelialization was not detected in any case. The high frequency of Matrix P® and Matrix P plus® graft failure can be related to inflammation and fibrosis revealed by MRI and histology. Our results do not support the use of these valves for PVR and suggest careful follow-up examinations, including MRI for early detection of graft inflammation and fibrosis.
- Open Access
- 27 February 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (3) , 462-467
Anatomical and functional assessment of the intra-atrial lateral tunnel in the Fontan circulation†
In patients after completion of the total cavopulmonary connection (TCPC) with an intra-atrial lateral tunnel, deviations of the tunnel from an ideal straight tubular shape were observed. However, little is known about frequency and adverse effects of such shape deviations. We sought to analyse tunnel anatomy, dimensions and blood flow using cardiac magnetic resonance imaging (CMR). Fifty-four patients with hypoplastic left heart syndrome (HLHS; mean age 6.0 ± 2.4 years) underwent CMR with gradient-echo cine sequences, 2D- and 3D-phase-contrast imaging. We analysed anatomy, diameters, cross-sectional areas, volumes and blood flow of the tunnel. Twenty-five patients had a tubular tunnel. In 29 patients, bulging and/or narrowing of the tunnel were present. Cross-sectional areas and volumes of the tunnel were not significantly different between the two groups. There were also no differences for the mean blood flow and the mean and maximal flow velocity (P = 0.05–0.6). In all the patients, the normalized tunnel volume was related to age (r = 0.44; P = 0.002) and body surface area (BSA; r = 0.42; P = 0.005). The mean tunnel blood flow correlated with age (r = 0.73; P = 0.001) and BSA (r = 0.83; P < 0.0001). A considerable percentage of patients with an intra-atrial lateral tunnel develop mild deviations of the tunnel from ideal tubular shape. The correlation between tunnel volume and mean blood flow with age and BSA suggests that the capacity of the tunnel adjusts to body growth, independent of tunnel shapes that deviate from a fluid-dynamically favourable shape. Follow-up CMRs are needed to detect long-term effects of irregular tunnel shapes on flow dynamics.
- 27 February 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (3) , 462-467
Open AccessAnatomical and functional assessment of the intra-atrial lateral tunnel in the Fontan circulation†
In patients after completion of the total cavopulmonary connection (TCPC) with an intra-atrial lateral tunnel, deviations of the tunnel from an ideal straight tubular shape were observed. However, little is known about frequency and adverse effects of such shape deviations. We sought to analyse tunnel anatomy, dimensions and blood flow using cardiac magnetic resonance imaging (CMR). Fifty-four patients with hypoplastic left heart syndrome (HLHS; mean age 6.0 ± 2.4 years) underwent CMR with gradient-echo cine sequences, 2D- and 3D-phase-contrast imaging. We analysed anatomy, diameters, cross-sectional areas, volumes and blood flow of the tunnel. Twenty-five patients had a tubular tunnel. In 29 patients, bulging and/or narrowing of the tunnel were present. Cross-sectional areas and volumes of the tunnel were not significantly different between the two groups. There were also no differences for the mean blood flow and the mean and maximal flow velocity (P = 0.05–0.6). In all the patients, the normalized tunnel volume was related to age (r = 0.44; P = 0.002) and body surface area (BSA; r = 0.42; P = 0.005). The mean tunnel blood flow correlated with age (r = 0.73; P = 0.001) and BSA (r = 0.83; P < 0.0001). A considerable percentage of patients with an intra-atrial lateral tunnel develop mild deviations of the tunnel from ideal tubular shape. The correlation between tunnel volume and mean blood flow with age and BSA suggests that the capacity of the tunnel adjusts to body growth, independent of tunnel shapes that deviate from a fluid-dynamically favourable shape. Follow-up CMRs are needed to detect long-term effects of irregular tunnel shapes on flow dynamics.
- Open Access
- 4 February 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (6) , 1718-1727
Determination of volume–time curves for the right ventricle and its outflow tract for functional analyses
Purpose: The determination of right ventricular volumes and function is of increasing interest for the postoperative care of patients with congenital heart defects. The presentation of volumetry data in terms of volume‐time curves allows a comprehensive functional assessment. By using manual contour tracing, the generation of volume–time curves is exceedingly time‐consuming.Methods: This study describes a fast and precise method for determining volume–time curves for the right ventricle and for the right ventricular outflow tract. The method applies contour detection and includes a feature for identifying the right ventricular outflow tract volume. The segregation of the outflow tract is performed by four‐dimensional curved smooth boundary surfaces defined by prespecified anatomical landmarks.Results: The comparison with manual contour tracing demonstrates that the method is accurate and improves the precision of the measurement. Compared to manual contour tracing the bias is <0.1% ± 4.1% (right ventricle) and −2.6% ± 20.0% (right ventricular outflow tract). The standard deviations of inter‐ and intraobserver variabilities for determining the volume of the right ventricular outflow tract are reduced to less than half the values of manual contour tracing. The time consumption per patient is reduced from 341 ± 80 min (right ventricle) and 56 ± 11 min (right ventricular outflow tract) using manual contour tracing to 46 ± 9 min for a combined analysis of right ventricle and right ventricular outflow tract.Conclusion: The analysis of volume–time curves for the right ventricle and its outflow tract discloses new evaluation methods in clinical routine and science. Magn Reson Med 70:1718–1727, 2013.
- 4 February 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (6) , 1718-1727
Open AccessDetermination of volume–time curves for the right ventricle and its outflow tract for functional analyses
Purpose: The determination of right ventricular volumes and function is of increasing interest for the postoperative care of patients with congenital heart defects. The presentation of volumetry data in terms of volume‐time curves allows a comprehensive functional assessment. By using manual contour tracing, the generation of volume–time curves is exceedingly time‐consuming.Methods: This study describes a fast and precise method for determining volume–time curves for the right ventricle and for the right ventricular outflow tract. The method applies contour detection and includes a feature for identifying the right ventricular outflow tract volume. The segregation of the outflow tract is performed by four‐dimensional curved smooth boundary surfaces defined by prespecified anatomical landmarks.Results: The comparison with manual contour tracing demonstrates that the method is accurate and improves the precision of the measurement. Compared to manual contour tracing the bias is <0.1% ± 4.1% (right ventricle) and −2.6% ± 20.0% (right ventricular outflow tract). The standard deviations of inter‐ and intraobserver variabilities for determining the volume of the right ventricular outflow tract are reduced to less than half the values of manual contour tracing. The time consumption per patient is reduced from 341 ± 80 min (right ventricle) and 56 ± 11 min (right ventricular outflow tract) using manual contour tracing to 46 ± 9 min for a combined analysis of right ventricle and right ventricular outflow tract.Conclusion: The analysis of volume–time curves for the right ventricle and its outflow tract discloses new evaluation methods in clinical routine and science. Magn Reson Med 70:1718–1727, 2013.
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 41-77
Normal values of aortic dimensions, distensibility, and pulse wave velocity in children and young adults: a cross-sectional study
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 41-77
Open AccessNormal values of aortic dimensions, distensibility, and pulse wave velocity in children and young adults: a cross-sectional study
- 30 August 2011
- Published by Springer Nature in Pediatric Radiology
- Vol. 41 (11) , 1429-1432
Improved MRI of the neonatal heart: feasibility study using a knee coil
As a first step towards the development of a neonatal cardiac MRI (CMRI) coil, we investigated the utilization, handling and image quality of a knee coil for CMRI in infants at 3 Tesla. Scout imaging and cine imaging with optimized pulse sequence parameters were performed in two neonates and the resulting images were evaluated for diagnostic purposes. All images were of high diagnostic quality. Complete examinations took less than five minutes. The excellent signal-to-noise ratio provided by this coil allowed all cine studies to be acquired with only three averages. In conclusion, a knee coil can be successfully applied in neonates for CMRI, but the coil design could be improved further to facilitate routine clinical use.
- 30 August 2011
- Published by Springer Nature in Pediatric Radiology
- Vol. 41 (11) , 1429-1432
Improved MRI of the neonatal heart: feasibility study using a knee coil
As a first step towards the development of a neonatal cardiac MRI (CMRI) coil, we investigated the utilization, handling and image quality of a knee coil for CMRI in infants at 3 Tesla. Scout imaging and cine imaging with optimized pulse sequence parameters were performed in two neonates and the resulting images were evaluated for diagnostic purposes. All images were of high diagnostic quality. Complete examinations took less than five minutes. The excellent signal-to-noise ratio provided by this coil allowed all cine studies to be acquired with only three averages. In conclusion, a knee coil can be successfully applied in neonates for CMRI, but the coil design could be improved further to facilitate routine clinical use.
- 10 July 2010
- Published by Springer Nature in Der Radiologe
- Vol. 50 (9) , 799-808
3-Tesla-Magnetresonanztomographie zur Untersuchung von Kindern und Erwachsenen mit angeborenen Herzfehlern
- 10 July 2010
- Published by Springer Nature in Der Radiologe
- Vol. 50 (9) , 799-808
3-Tesla-Magnetresonanztomographie zur Untersuchung von Kindern und Erwachsenen mit angeborenen Herzfehlern