Bernd Jung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bernd Jung has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Michael Markl
Department of Radiology Northwestern University Chicago Illinois USA
11 shared publicationsJürgen Hennig
Department of Diagnostic Radiology, Medical Physics, University Hospital, Freiburg, Germany
7 shared publicationsDaniela Föll
Department of Radiology University Medical Center Freiburg Germany
3 shared publicationsMatthias Honal
Department of Diagnostic Radiology, Medical Physics, University Hospital, Freiburg, Germany
3 shared publications- Michael Markl
Department of Radiology, Medical Physics, University Hospital Freiburg, Breisacher Str. 60a, 79106 Freiburg, Germany
3 shared publications Simon Bauer
Siemens Medical Solutions, Erlangen, Germany
3 shared publications
Latest Publications
- 1 September 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (9) , 1388-1397
Phase-contrast magnet resonance imaging reveals regional, transmural, and base-to-apex dispersion of mechanical dysfunction in patients with long QT syndrome
- 1 September 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (9) , 1388-1397
Phase-contrast magnet resonance imaging reveals regional, transmural, and base-to-apex dispersion of mechanical dysfunction in patients with long QT syndrome
- 22 March 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (4) , 805-817
Spin echo magnetic resonance imaging
The spin echo sequence is a fundamental pulse sequence in MRI. Many of today's applications in routine clinical use are based on this elementary sequence. In this review article, the principles of the spin echo formation are demonstrated on which the generation of the fundamental image contrasts T1, T2, and proton density is based. The basic imaging parameters repetition time (TR) and echo time (TE) and their influence on the image contrast are explained. Important properties such as the behavior in multi‐slice imaging or in the presence of flow are depicted and the basic differences with gradient echo imaging are illustrated. The characteristics of the spin echo sequence for different magnetic field strengths with respect to clinical applications are discussed. J. Magn. Reson. Imaging 2013;37:805–817.
- 22 March 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (4) , 805-817
Spin echo magnetic resonance imaging
The spin echo sequence is a fundamental pulse sequence in MRI. Many of today's applications in routine clinical use are based on this elementary sequence. In this review article, the principles of the spin echo formation are demonstrated on which the generation of the fundamental image contrasts T1, T2, and proton density is based. The basic imaging parameters repetition time (TR) and echo time (TE) and their influence on the image contrast are explained. Important properties such as the behavior in multi‐slice imaging or in the presence of flow are depicted and the basic differences with gradient echo imaging are illustrated. The characteristics of the spin echo sequence for different magnetic field strengths with respect to clinical applications are discussed. J. Magn. Reson. Imaging 2013;37:805–817.
- 21 March 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (5) , 1054-1062
K‐t GRAPPA accelerated phase contrast MRI: Improved assessment of blood flow and 3‐directional myocardial motion during breath‐hold
Purpose: To evaluate spatiotemporal parallel imaging with R = 5 in comparison to conventional parallel imaging with R = 2 applied to phase contrast (PC) magnetic resonance imaging (MRI). This was motivated by the fact that scan times for PC imaging often exceed breath‐hold capabilities of patients even with standard parallel imaging using typical reduction factors of R = 2.Materials and Methods: K‐t generalized autocalibrating partially parallel acquisition (GRAPPA) acquisition was validated in phantom measurements and then applied in 10 volunteer and three patient examinations. Due to the higher reduction factor compared to conventional GRAPPA, k‐t GRAPPA measurements could be performed during breath‐hold with high spatial and temporal resolution. K‐t GRAPPA scans were compared to GRAPPA acquired during free‐breathing with navigator respiration control. In addition, spatiotemporally accelerated PC imaging was acquired during free‐breathing for comparison of k‐t‐accelerated breath‐held scans.Results: Substantial improvements in image quality for the breath‐hold measurements were observed. Significantly reduced peak velocities were found for the GRAPPA protocol compared to the k‐t‐accelerated breath‐hold scans for both flow (8%) and myocardial motion (up to 30%) measurements.Conclusion: Spatiotemporal acceleration allows the performance of high temporal or spatial resolution PC imaging during breath‐hold while providing high image quality and robust acquisition of functional information that cannot be achieved during breath‐hold with standard techniques. J. Magn. Reson. Imaging 2013;38:1054–1062.
- 21 March 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (5) , 1054-1062
K‐t GRAPPA accelerated phase contrast MRI: Improved assessment of blood flow and 3‐directional myocardial motion during breath‐hold
Purpose: To evaluate spatiotemporal parallel imaging with R = 5 in comparison to conventional parallel imaging with R = 2 applied to phase contrast (PC) magnetic resonance imaging (MRI). This was motivated by the fact that scan times for PC imaging often exceed breath‐hold capabilities of patients even with standard parallel imaging using typical reduction factors of R = 2.Materials and Methods: K‐t generalized autocalibrating partially parallel acquisition (GRAPPA) acquisition was validated in phantom measurements and then applied in 10 volunteer and three patient examinations. Due to the higher reduction factor compared to conventional GRAPPA, k‐t GRAPPA measurements could be performed during breath‐hold with high spatial and temporal resolution. K‐t GRAPPA scans were compared to GRAPPA acquired during free‐breathing with navigator respiration control. In addition, spatiotemporally accelerated PC imaging was acquired during free‐breathing for comparison of k‐t‐accelerated breath‐held scans.Results: Substantial improvements in image quality for the breath‐hold measurements were observed. Significantly reduced peak velocities were found for the GRAPPA protocol compared to the k‐t‐accelerated breath‐hold scans for both flow (8%) and myocardial motion (up to 30%) measurements.Conclusion: Spatiotemporal acceleration allows the performance of high temporal or spatial resolution PC imaging during breath‐hold while providing high image quality and robust acquisition of functional information that cannot be achieved during breath‐hold with standard techniques. J. Magn. Reson. Imaging 2013;38:1054–1062.
- 8 March 2013
- Published by Springer Nature in Experiments in Fluids
- Vol. 54 (3) , 1-15
Phase-locked 3D3C-MRV measurements in a bi-stable fluidic oscillator
- 8 March 2013
- Published by Springer Nature in Experiments in Fluids
- Vol. 54 (3) , 1-15
Phase-locked 3D3C-MRV measurements in a bi-stable fluidic oscillator
- Open Access
- 28 February 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (3) , 551-558
Effect of cannula position in the thoracic aorta with continuous left ventricular support: four-dimensional flow-sensitive magnetic resonance imaging in an in vitro model
Left ventricular assist devices (LVADs) have become an important treatment option for heart failure patients. However, altered blood flow patterns are suspected to affect perfusion in the aorta or cause structural changes to the aortic root, leading to regurgitation and valve dysfunction or thrombus formation. The purpose of this study was to evaluate flow patterns in a realistic in vitro model system using four-dimensional flow-sensitive magnetic resonance imaging. A magnetic resonance compatible model system was developed consisting of an aorta connected to a VAD simulating the pulsatile flow of the native heart. An LVAD was connected to the aorta model via three different cannula positions. Flow patterns in the entire system as well as flow rates in predefined positions for reduced and zero cardiac output were evaluated. Cannula position influences flow patterns and flow rates in the entire thoracic aorta. For a residual cardiac output, a larger anastomosis and a decreased flow rate of the LAVD result in a higher flow rate and smaller retrograde flow in the ascending aorta when compared with a smaller anastomosis or a cannula position in the descending aorta. Pronounced flow turbulences in the aorta were observed for the cannula position in the descending aorta. In the setting of reduced cardiac output, as commonly observed in patients on LVAD therapy, a large anastomosis to the ascending aorta for the outflow cannula induces the least-adverse flow patterns in the aortic root. Our approach may aid in a better understanding of LVAD-induced flow-pattern changes. Optimization of the cannula position and anastomosis may help to prevent the progression of aortic valve-regurgitation and thrombus formation.
- 28 February 2013
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 44 (3) , 551-558
Open AccessEffect of cannula position in the thoracic aorta with continuous left ventricular support: four-dimensional flow-sensitive magnetic resonance imaging in an in vitro model
Left ventricular assist devices (LVADs) have become an important treatment option for heart failure patients. However, altered blood flow patterns are suspected to affect perfusion in the aorta or cause structural changes to the aortic root, leading to regurgitation and valve dysfunction or thrombus formation. The purpose of this study was to evaluate flow patterns in a realistic in vitro model system using four-dimensional flow-sensitive magnetic resonance imaging. A magnetic resonance compatible model system was developed consisting of an aorta connected to a VAD simulating the pulsatile flow of the native heart. An LVAD was connected to the aorta model via three different cannula positions. Flow patterns in the entire system as well as flow rates in predefined positions for reduced and zero cardiac output were evaluated. Cannula position influences flow patterns and flow rates in the entire thoracic aorta. For a residual cardiac output, a larger anastomosis and a decreased flow rate of the LAVD result in a higher flow rate and smaller retrograde flow in the ascending aorta when compared with a smaller anastomosis or a cannula position in the descending aorta. Pronounced flow turbulences in the aorta were observed for the cannula position in the descending aorta. In the setting of reduced cardiac output, as commonly observed in patients on LVAD therapy, a large anastomosis to the ascending aorta for the outflow cannula induces the least-adverse flow patterns in the aortic root. Our approach may aid in a better understanding of LVAD-induced flow-pattern changes. Optimization of the cannula position and anastomosis may help to prevent the progression of aortic valve-regurgitation and thrombus formation.
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 90-87
A quantitative comparison of regional myocardial motion in mice, rabbits and humans using in-vivo phase contrast CMR
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 90-87
Open AccessA quantitative comparison of regional myocardial motion in mice, rabbits and humans using in-vivo phase contrast CMR
- Open Access
- 16 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (1) , 50-61
Analysis of complex cardiovascular flow with three‐component acceleration‐encoded MRI
Functional information regarding cardiac performance, pressure gradients, and local flow derangement are available from blood acceleration fields. Thus, this study examines a 2D and 3D phase contrast sequence optimized to efficiently encode three‐directional, time‐resolved acceleration in vitro and in vivo. Stenosis phantom acceleration measurements were compared to acceleration derived from standard velocity encoded phase contrast‐magnetic resonance imaging (i.e., “velocity‐derived acceleration”). For in vivo analysis, three‐directional 2D acceleration maps were compared to velocity‐derived acceleration using regions proximal and distal to the aortic valve in six healthy volunteers at 1.5 and 3.0 T (voxel size = 1.4 × 2.1 × 8 mm, temporal resolution = 16–20 ms). In addition, a 4D acceleration sequence was evaluated for feasibility in a healthy volunteer and postrepair biscuspid aortic valve patient with an ascending aortic aneurysm. The phantom magnetic resonance acceleration measurements were more accurate (nonturbulent root mean square error = 2.2 vs. 5.1 m/s2 for phase contrast‐magnetic resonance imaging) and 10 times less noisy (nonturbulent σ = 0.9 vs. 13.6 m/s2 for phase contrast‐magnetic resonance imaging) than velocity‐derived acceleration. Acceleration mapping of the left ventricular outflow tract and aortic arch exhibited signal voids colocated with complex flow events such as vortex formation and high order motion. 4D acceleration data, visualized in combination with the velocity data, may provide new insight into complex flow phenomena. Magn Reson Med 67:50–61, 2012.
- 16 May 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (1) , 50-61
Open AccessAnalysis of complex cardiovascular flow with three‐component acceleration‐encoded MRI
Functional information regarding cardiac performance, pressure gradients, and local flow derangement are available from blood acceleration fields. Thus, this study examines a 2D and 3D phase contrast sequence optimized to efficiently encode three‐directional, time‐resolved acceleration in vitro and in vivo. Stenosis phantom acceleration measurements were compared to acceleration derived from standard velocity encoded phase contrast‐magnetic resonance imaging (i.e., “velocity‐derived acceleration”). For in vivo analysis, three‐directional 2D acceleration maps were compared to velocity‐derived acceleration using regions proximal and distal to the aortic valve in six healthy volunteers at 1.5 and 3.0 T (voxel size = 1.4 × 2.1 × 8 mm, temporal resolution = 16–20 ms). In addition, a 4D acceleration sequence was evaluated for feasibility in a healthy volunteer and postrepair biscuspid aortic valve patient with an ascending aortic aneurysm. The phantom magnetic resonance acceleration measurements were more accurate (nonturbulent root mean square error = 2.2 vs. 5.1 m/s2 for phase contrast‐magnetic resonance imaging) and 10 times less noisy (nonturbulent σ = 0.9 vs. 13.6 m/s2 for phase contrast‐magnetic resonance imaging) than velocity‐derived acceleration. Acceleration mapping of the left ventricular outflow tract and aortic arch exhibited signal voids colocated with complex flow events such as vortex formation and high order motion. 4D acceleration data, visualized in combination with the velocity data, may provide new insight into complex flow phenomena. Magn Reson Med 67:50–61, 2012.
- Open Access
- 24 March 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (4) , 966-975
On the undersampling strategies to accelerate time‐resolved 3D imaging using k‐t‐GRAPPA
The purpose of this study was to explore how to optimally undersample and reconstruct time‐resolved 3D data using a k‐t‐space‐based GRAPPA technique. The performance of different reconstruction strategies was evaluated using data sets with different ratios of phase (Ny) and partition (Nz) encoding lines (Ny × Nz = 64–128 × 40–64) acquired in a moving phantom. Image reconstruction was performed for different kernel configurations and different reduction factors (R = 5, 6, 8, and 10) and was evaluated using regional error quantification and SNR analysis. To analyze the temporal fidelity of the different kernel configurations in vivo, time‐resolved 3D phase contrast data were acquired in the thoracic aorta of two healthy volunteers. Results demonstrated that kernel configurations with a small kernel extension yielded superior results especially for more asymmetric data matrices as typically used in clinical applications. The application of k‐t‐GRAPPA to in vivo data demonstrated the feasibility of undersampling of time‐resolved 3D phase contrast data set with a nominal reduction factors of up to Rnet = 8, while maintaining the temporal fidelity of the measured velocity field. Extended GRAPPA‐based parallel imaging with optimized multidimensional reconstruction kernels has the potential to substantially accelerate data acquisitions in time‐resolved 3D MRI. Magn Reson Med, 2011.
- 24 March 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (4) , 966-975
Open AccessOn the undersampling strategies to accelerate time‐resolved 3D imaging using k‐t‐GRAPPA
The purpose of this study was to explore how to optimally undersample and reconstruct time‐resolved 3D data using a k‐t‐space‐based GRAPPA technique. The performance of different reconstruction strategies was evaluated using data sets with different ratios of phase (Ny) and partition (Nz) encoding lines (Ny × Nz = 64–128 × 40–64) acquired in a moving phantom. Image reconstruction was performed for different kernel configurations and different reduction factors (R = 5, 6, 8, and 10) and was evaluated using regional error quantification and SNR analysis. To analyze the temporal fidelity of the different kernel configurations in vivo, time‐resolved 3D phase contrast data were acquired in the thoracic aorta of two healthy volunteers. Results demonstrated that kernel configurations with a small kernel extension yielded superior results especially for more asymmetric data matrices as typically used in clinical applications. The application of k‐t‐GRAPPA to in vivo data demonstrated the feasibility of undersampling of time‐resolved 3D phase contrast data set with a nominal reduction factors of up to Rnet = 8, while maintaining the temporal fidelity of the measured velocity field. Extended GRAPPA‐based parallel imaging with optimized multidimensional reconstruction kernels has the potential to substantially accelerate data acquisitions in time‐resolved 3D MRI. Magn Reson Med, 2011.