Robin Simpson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robin Simpson has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- David Nigel Firmin
Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, United Kingdom
4 shared publications Jennifer Keegan
NIHR Royal Brompton Cardiovascular Biomedical Research Unit, London, UK
2 shared publications- Jennifer Keegan
Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Trust, London, UK
2 shared publications - Alun David Hughes
Institute of Cardiovascular Science, University College London, London, UK
1 shared publication - Carlo Di Mario
Structural Interventional Cardiology, Department of Clinical and Experimental Medicine, Careggi University Hospital, Florence, Italy
1 shared publication - Claire E. Raphael
NIHR Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 93-12
Feasibility of cardiovascular magnetic resonance derived coronary wave intensity analysis
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 93-12
Open AccessFeasibility of cardiovascular magnetic resonance derived coronary wave intensity analysis
- Open Access
- 7 October 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (3) , 659-668
Spiral tissue phase velocity mapping in a breath‐hold with non‐cartesian SENSE
Purpose Tissue phase velocity mapping (TPVM) is capable of reproducibly measuring regional myocardial velocities. However acquisition durations of navigator gated techniques are long and unpredictable while current breath‐hold techniques have low temporal resolution. This study presents a spiral TPVM technique which acquires high resolution data within a clinically acceptable breath‐hold duration. Methods Ten healthy volunteers are scanned using a spiral sequence with temporal resolution of 24 ms and spatial resolution of 1.7 × 1.7 mm. Retrospective cardiac gating is used to acquire data over the entire cardiac cycle. The acquisition is accelerated by factors of 2 and 3 by use of non‐Cartesian SENSE implemented on the Gadgetron GPU system resulting in breath‐holds of 17 and 13 heartbeats, respectively. Systolic, early diastolic, and atrial systolic global and regional longitudinal, circumferential, and radial velocities are determined. Results Global and regional velocities agree well with those previously reported. The two acceleration factors show no significant differences for any quantitative parameter and the results also closely match previously acquired higher spatial resolution navigator‐gated data in the same subjects. Conclusion By using spiral trajectories and non‐Cartesian SENSE high resolution, TPVM data can be acquired within a clinically acceptable breath‐hold. Magn Reson Med 72:659–668, 2014.
- 7 October 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (3) , 659-668
Open AccessSpiral tissue phase velocity mapping in a breath‐hold with non‐cartesian SENSE
Purpose Tissue phase velocity mapping (TPVM) is capable of reproducibly measuring regional myocardial velocities. However acquisition durations of navigator gated techniques are long and unpredictable while current breath‐hold techniques have low temporal resolution. This study presents a spiral TPVM technique which acquires high resolution data within a clinically acceptable breath‐hold duration. Methods Ten healthy volunteers are scanned using a spiral sequence with temporal resolution of 24 ms and spatial resolution of 1.7 × 1.7 mm. Retrospective cardiac gating is used to acquire data over the entire cardiac cycle. The acquisition is accelerated by factors of 2 and 3 by use of non‐Cartesian SENSE implemented on the Gadgetron GPU system resulting in breath‐holds of 17 and 13 heartbeats, respectively. Systolic, early diastolic, and atrial systolic global and regional longitudinal, circumferential, and radial velocities are determined. Results Global and regional velocities agree well with those previously reported. The two acceleration factors show no significant differences for any quantitative parameter and the results also closely match previously acquired higher spatial resolution navigator‐gated data in the same subjects. Conclusion By using spiral trajectories and non‐Cartesian SENSE high resolution, TPVM data can be acquired within a clinically acceptable breath‐hold. Magn Reson Med 72:659–668, 2014.
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 34
Efficient and reproducible high resolution spiral myocardial phase velocity mapping of the entire cardiac cycle
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 34
Open AccessEfficient and reproducible high resolution spiral myocardial phase velocity mapping of the entire cardiac cycle
- 23 July 2012
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (3) , 576-599
MR assessment of regional myocardial mechanics
Regional myocardial function can be measured by several MR techniques including tissue tagging, phase velocity mapping, and more recently, displacement encoding with stimulated echoes (DENSE) and strain encoding (SENC). Each of these techniques was developed separately and has undergone significant change since its original implementation. As a result, in the current literature, the common features and the differences between the techniques and what they measure are often unclear and confusing. This review article delivers an extensively referenced introductory text which clarifies the current methodology from the starting point of the Bloch equations. By doing this in a consistent way for each method, the similarities and differences between them are highlighted. In addition, their capabilities and limitations are discussed, together with their relative advantages and disadvantages. While the focus is on sequence design and development, the principal parameters measured by each technique are also summarized, together with brief results, with the reader being directed to the extensive literature on data processing and clinical applications for more detail. J. Magn. Reson. Imaging 2013;37:576–599.
- 23 July 2012
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (3) , 576-599
MR assessment of regional myocardial mechanics
Regional myocardial function can be measured by several MR techniques including tissue tagging, phase velocity mapping, and more recently, displacement encoding with stimulated echoes (DENSE) and strain encoding (SENC). Each of these techniques was developed separately and has undergone significant change since its original implementation. As a result, in the current literature, the common features and the differences between the techniques and what they measure are often unclear and confusing. This review article delivers an extensively referenced introductory text which clarifies the current methodology from the starting point of the Bloch equations. By doing this in a consistent way for each method, the similarities and differences between them are highlighted. In addition, their capabilities and limitations are discussed, together with their relative advantages and disadvantages. While the focus is on sequence design and development, the principal parameters measured by each technique are also summarized, together with brief results, with the reader being directed to the extensive literature on data processing and clinical applications for more detail. J. Magn. Reson. Imaging 2013;37:576–599.