Mark A Tanner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mark A Tanner has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Dudley John Pennell
National Heart and Lung Institute, Imperial College London
3 shared publications - John Malcolm Walker
Hatter Cardiovascular Institute, University College London, London, United Kingdom
2 shared publications - Mark A. Westwood
Barts Heart Centre, St. Bartholomew's Hospital, West Smithfield, London, United Kingdom
2 shared publications - Renzo Galanello
Ospedale Regionale per le Microcitemie, Cagliari, Italy
2 shared publications - Sunil V Nair
University College Hospital, London, UK
2 shared publications Annalisa Agus
Ospedale Regionale per le Microcitemie, Cagliari, Italy
1 shared publication
Latest Publications
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 8
Effects of combined deferiprone with deferoxamine on right ventricular function in thalassaemia major
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 8
Open AccessEffects of combined deferiprone with deferoxamine on right ventricular function in thalassaemia major
- Open Access
- 1 January 2008
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 10 (1) , 12
Combined chelation therapy in thalassemia major for the treatment of severe myocardial siderosis with left ventricular dysfunction
- 1 January 2008
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 10 (1) , 12
Open AccessCombined chelation therapy in thalassemia major for the treatment of severe myocardial siderosis with left ventricular dysfunction
- 1 October 2006
- Vol. 91 (10) , 1388-91
Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron.
The transferability of the T2* technique for measurement of tissue iron between magnetic resonance (MR) scanners is unknown. Heart and liver multi-breath-hold T2* sequences were installed on MR scanners at six different sites. T2* was assessed locally in five or more patients with thalassemia major (n=39), and subjects were re-scanned at the standardization center in London. Inter-center reproducibility of T2* in heart and liver was 5.0% and 7.1%, with mean absolute differences in T2* of 1.3 ms and 0.45 ms, respectively. The MR multi-breath-hold T2* technique for tissue iron quantification is transferable between scanners with good reproducibility.
- 1 October 2006
- Vol. 91 (10) , 1388-91
Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron.
The transferability of the T2* technique for measurement of tissue iron between magnetic resonance (MR) scanners is unknown. Heart and liver multi-breath-hold T2* sequences were installed on MR scanners at six different sites. T2* was assessed locally in five or more patients with thalassemia major (n=39), and subjects were re-scanned at the standardization center in London. Inter-center reproducibility of T2* in heart and liver was 5.0% and 7.1%, with mean absolute differences in T2* of 1.3 ms and 0.45 ms, respectively. The MR multi-breath-hold T2* technique for tissue iron quantification is transferable between scanners with good reproducibility.