Pierre-André Doriot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pierre-André Doriot has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
P.-A. Dorsaz
Cardiology Division, University Hospital, Geneva, Switzerland
4 shared publicationsL. Dorsaz
3 shared publicationsLidia Dorsaz
2 shared publicationsP.‐A. Dorsaz
2 shared publicationsPascal Chatelain
2 shared publicationsPierre-André Dorsaz
2 shared publications
Latest Publications
- Open Access
- 5 May 2008
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 3 (1) , 24
Why can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
Radiofrequency catheter ablation of excitation foci inside pulmonary veins (PV) generates stenoses that can become quite severe during or after the follow-up period. Since severe PV stenoses have most often disastrous consequences, it would be important to know the underlying mechanism of this temporal evolution. The present study proposes a potential explanation based on mechanical considerations.
- 5 May 2008
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 3 (1) , 24
Open AccessWhy can pulmonary vein stenoses created by radiofrequency catheter ablation worsen during and after follow-up ? A potential explanation
Radiofrequency catheter ablation of excitation foci inside pulmonary veins (PV) generates stenoses that can become quite severe during or after the follow-up period. Since severe PV stenoses have most often disastrous consequences, it would be important to know the underlying mechanism of this temporal evolution. The present study proposes a potential explanation based on mechanical considerations.
- 31 December 2007
- Published by Elsevier in Medical Hypotheses
- Vol. 68 (4) , 781-798
Are intramural suction-squeezing effects generated by the variations in radial wall stress during each heart beat the motor of atherosclerosis? A new concept
- 31 December 2007
- Published by Elsevier in Medical Hypotheses
- Vol. 68 (4) , 781-798
Are intramural suction-squeezing effects generated by the variations in radial wall stress during each heart beat the motor of atherosclerosis? A new concept
- Open Access
- 9 August 2007
- Published by Springer Nature in Theoretical Biology and Medical Modelling
- Vol. 4 (1) , 29
Could increased axial wall stress be responsible for the development of atheroma in the proximal segment of myocardial bridges?
A recent model describing the mechanical interaction between a stenosis and the vessel wall has shown that axial wall stress can considerably increase in the region immediately proximal to the stenosis during the (forward) flow phases, so that abnormal biological processes and wall damages are likely to be induced in that region. Our objective was to examine what this model predicts when applied to myocardial bridges.
- 9 August 2007
- Published by Springer Nature in Theoretical Biology and Medical Modelling
- Vol. 4 (1) , 29
Open AccessCould increased axial wall stress be responsible for the development of atheroma in the proximal segment of myocardial bridges?
A recent model describing the mechanical interaction between a stenosis and the vessel wall has shown that axial wall stress can considerably increase in the region immediately proximal to the stenosis during the (forward) flow phases, so that abnormal biological processes and wall damages are likely to be induced in that region. Our objective was to examine what this model predicts when applied to myocardial bridges.
- 1 May 2006
- Published by SAGE Publications in Technology and Health Care
- Vol. 14 (2) , 59-68
An analytical model for the investigation of axial wall forces generated by an arterial stenosis
The causes of arteriosclerosis are intensively investigated since many decades. While circumferential wall stress has received a lot of attention, axial stress (also called “longitudinal” stress) has been largely neglected, and practically never incr
- 1 May 2006
- Published by SAGE Publications in Technology and Health Care
- Vol. 14 (2) , 59-68
An analytical model for the investigation of axial wall forces generated by an arterial stenosis
The causes of arteriosclerosis are intensively investigated since many decades. While circumferential wall stress has received a lot of attention, axial stress (also called “longitudinal” stress) has been largely neglected, and practically never incr
- 1 June 2004
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 11 (3) , 310-318
Residual Stenosis Poststenting and Subsequent Decrease in the Proximal Reference Diameter Are Correlated:Excessive Axial Wall Stress Is a Plausible Explanation
Purpose: To test the hypothesis that edge restenosis in stented lesions might be due to an increase in axial wall stress in the adjacent proximal vessel segment by examining whether the proximal reference diameters of conventionally stented lesions are reduced at follow-up and whether this reduction depends on the degree of residual stenosis poststenting. Methods: The literature published in the past 5 years dealing with restenosis following implantation of standard stents was screened for the availability of (1) reference vessel diameters poststenting, (2) mean residual stenosis poststenting, and (3) mean reference vessel diameters at follow-up in the same patients or groups of patients. Data collected from 11 publications were pooled and used to compute the change in reference segment diameter over time. These differences were compared to the residual stenosis poststenting by nonlinear regression. Results: The reduction in the mean reference diameters over time and the mean residual stenosis poststenting appear to be strongly correlated (r 2=0.838), which supports the idea that the evolution of a stenosis adjacent to a stent margin depends on the severity of the residual stenosis. Conclusions: This finding indicates that edge restenosis might be due to excessive axial wall stress. It may also explain, at least partly, why edge restenosis is observed with catheter-based brachytherapy and radioactive or drug-eluting stents.
- 1 June 2004
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 11 (3) , 310-318
Residual Stenosis Poststenting and Subsequent Decrease in the Proximal Reference Diameter Are Correlated:Excessive Axial Wall Stress Is a Plausible Explanation
Purpose: To test the hypothesis that edge restenosis in stented lesions might be due to an increase in axial wall stress in the adjacent proximal vessel segment by examining whether the proximal reference diameters of conventionally stented lesions are reduced at follow-up and whether this reduction depends on the degree of residual stenosis poststenting. Methods: The literature published in the past 5 years dealing with restenosis following implantation of standard stents was screened for the availability of (1) reference vessel diameters poststenting, (2) mean residual stenosis poststenting, and (3) mean reference vessel diameters at follow-up in the same patients or groups of patients. Data collected from 11 publications were pooled and used to compute the change in reference segment diameter over time. These differences were compared to the residual stenosis poststenting by nonlinear regression. Results: The reduction in the mean reference diameters over time and the mean residual stenosis poststenting appear to be strongly correlated (r 2=0.838), which supports the idea that the evolution of a stenosis adjacent to a stent margin depends on the severity of the residual stenosis. Conclusions: This finding indicates that edge restenosis might be due to excessive axial wall stress. It may also explain, at least partly, why edge restenosis is observed with catheter-based brachytherapy and radioactive or drug-eluting stents.
- 1 April 2003
- Published by Elsevier in Cardiovascular Radiation Medicine
- Vol. 4 (2) , 108-115
A morphological-mechanical explanation of edge restenosis in lesions treated with vascular brachytherapy.
- 1 April 2003
- Published by Elsevier in Cardiovascular Radiation Medicine
- Vol. 4 (2) , 108-115
A morphological-mechanical explanation of edge restenosis in lesions treated with vascular brachytherapy.
- 1 March 2003
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 221 (1) , 133-141
Some Unusual Considerations about Vessel Walls and Wall Stresses
- 1 March 2003
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 221 (1) , 133-141
Some Unusual Considerations about Vessel Walls and Wall Stresses
- 21 February 2003
- Published by Wiley in Medical Physics
- Vol. 30 (3) , 424-432
Is axial wall stress compressive in certain arteries?
In mathematical-physical models of blood vessels, the "zero-stress state" of the vessel wall is usually defined with reference to the atmospheric pressure (pa approximately 750 mmHg = 100 kPa). Due to this conventional choice, axial and circumferential stresses generated by the (positive) transmural pressure over the radial wall depth can only be positive (in absence of residual stresses) and thus, by definition, only tensile. If the zero-stress state were defined "unconventionally" with reference to vacuum pressure (= 0 mm Hg), the isotropic compressive stress--pa generated by the atmospheric pressure everywhere in the wall would, however, be included in the stress values, and negative (= compressive) stresses would become formally possible. Since materials submitted only to compressions do not need to have the same resistive properties as materials which may also experience tractions, the question whether axial stress (and perhaps also circumferential stress) might be permanently compressive in vessels under physiologic conditions may therefore be important for investigations of the relationship between wall stresses on one side and wall structures, vessel growth, vessel damages, or vessel adaptation processes on the other side. In the present study, radial, circumferential, and axial wall stresses were calculated conventionally and "unconventionally" for three representative "vessel examples." The results clearly suggest that axial wall stress might well be compressive in many vessels. Furthermore, relative differences between conventional and unconventional stress values are quite considerable, and ratios between stresses calculated in the same manner appear to be strongly dependent on the chosen zero-stress state definition.
- 21 February 2003
- Published by Wiley in Medical Physics
- Vol. 30 (3) , 424-432
Is axial wall stress compressive in certain arteries?
In mathematical-physical models of blood vessels, the "zero-stress state" of the vessel wall is usually defined with reference to the atmospheric pressure (pa approximately 750 mmHg = 100 kPa). Due to this conventional choice, axial and circumferential stresses generated by the (positive) transmural pressure over the radial wall depth can only be positive (in absence of residual stresses) and thus, by definition, only tensile. If the zero-stress state were defined "unconventionally" with reference to vacuum pressure (= 0 mm Hg), the isotropic compressive stress--pa generated by the atmospheric pressure everywhere in the wall would, however, be included in the stress values, and negative (= compressive) stresses would become formally possible. Since materials submitted only to compressions do not need to have the same resistive properties as materials which may also experience tractions, the question whether axial stress (and perhaps also circumferential stress) might be permanently compressive in vessels under physiologic conditions may therefore be important for investigations of the relationship between wall stresses on one side and wall structures, vessel growth, vessel damages, or vessel adaptation processes on the other side. In the present study, radial, circumferential, and axial wall stresses were calculated conventionally and "unconventionally" for three representative "vessel examples." The results clearly suggest that axial wall stress might well be compressive in many vessels. Furthermore, relative differences between conventional and unconventional stress values are quite considerable, and ratios between stresses calculated in the same manner appear to be strongly dependent on the chosen zero-stress state definition.
- 2 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Contrast medium concentration threshold for angiographic measurements of absolute coronary blood flow
In this method for measurement of mean coronary flow from biplane angiograms, one has to threshold curves obtained by computing the intra-arterial contrast medium concentration along the arterial branches. To find the appropriate threshold value, the spreading of contrast medium injected continuously in a straight and rigid coronary artery was computer simulated. The theoretical investigation reveals the utmost importance of injecting the contrast medium at a rate roughly equal to or greater than peak coronary flow. The ratio of injection rate to peak coronary flow has a major impact. If this ratio is about 1 or greater, a concentration threshold of 50% seems to be a good choice.
- 2 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Contrast medium concentration threshold for angiographic measurements of absolute coronary blood flow
In this method for measurement of mean coronary flow from biplane angiograms, one has to threshold curves obtained by computing the intra-arterial contrast medium concentration along the arterial branches. To find the appropriate threshold value, the spreading of contrast medium injected continuously in a straight and rigid coronary artery was computer simulated. The theoretical investigation reveals the utmost importance of injecting the contrast medium at a rate roughly equal to or greater than peak coronary flow. The ratio of injection rate to peak coronary flow has a major impact. If this ratio is about 1 or greater, a concentration threshold of 50% seems to be a good choice.
- 1 September 2000
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 11 (6) , 495-502
In-vivo measurements of wall shear stress in human coronary arteries
Wall shear stress (WSS) is closely associated with arteriosclerosis. WSS values for various vessels and species are available, but fully in-vivo measurements in human coronary arteries have not yet been reported. To measure WSS in undiseased coronary arteries of adult patients at rest. We recorded the temporal average value (APV) of the instantaneous maximal blood velocity in the three vessel segments of angiographically normal coronary artery bifurcations in 21 patients undergoing cardiac catheterization to treat various diseases by means of a 0.036 cm Doppler wire (FloWire). In total, 36 bifurcations were examined. The 36 × 3 cross-sectional areas (CSA) were determined by means of a three-dimensional angiographic technique. The three flows, Q 1 (inflow), Q 2, and Q 3 of each bifurcation were calculated according to Q = 0.5 × APV × CSA. For each segment, WSS was calculated as WSS = 32 ηQ/(πD 3) (where blood viscosity η = 3.5 mPa s and D is vessel diameter). Only the 54 WSS values obtained from the 18 flow triplets which satisfied the equation Q 1/(Q 2 + Q 3) = 1 better than did the 18 other ones were retained. The 54 WSS values ranged from 0.33 to 1.24 Pa (mean 0.68 Pa, SEM, 0.027 Pa). They did not depend significantly on Q (r = 0.07;P = 0.60) and the CSA (r = 0.24, P = 0.08) but the second relationship approached significance. The obtained mean WSS value (0.68 Pa) is half the value predicted for coronary arteries from optimality principles. It is also smaller than many values reported for human carotid, renal, and femoral arteries.
- 1 September 2000
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 11 (6) , 495-502
In-vivo measurements of wall shear stress in human coronary arteries
Wall shear stress (WSS) is closely associated with arteriosclerosis. WSS values for various vessels and species are available, but fully in-vivo measurements in human coronary arteries have not yet been reported. To measure WSS in undiseased coronary arteries of adult patients at rest. We recorded the temporal average value (APV) of the instantaneous maximal blood velocity in the three vessel segments of angiographically normal coronary artery bifurcations in 21 patients undergoing cardiac catheterization to treat various diseases by means of a 0.036 cm Doppler wire (FloWire). In total, 36 bifurcations were examined. The 36 × 3 cross-sectional areas (CSA) were determined by means of a three-dimensional angiographic technique. The three flows, Q 1 (inflow), Q 2, and Q 3 of each bifurcation were calculated according to Q = 0.5 × APV × CSA. For each segment, WSS was calculated as WSS = 32 ηQ/(πD 3) (where blood viscosity η = 3.5 mPa s and D is vessel diameter). Only the 54 WSS values obtained from the 18 flow triplets which satisfied the equation Q 1/(Q 2 + Q 3) = 1 better than did the 18 other ones were retained. The 54 WSS values ranged from 0.33 to 1.24 Pa (mean 0.68 Pa, SEM, 0.027 Pa). They did not depend significantly on Q (r = 0.07;P = 0.60) and the CSA (r = 0.24, P = 0.08) but the second relationship approached significance. The obtained mean WSS value (0.68 Pa) is half the value predicted for coronary arteries from optimality principles. It is also smaller than many values reported for human carotid, renal, and femoral arteries.